113 changes: 113 additions & 0 deletions ecm_definitions/(C) 90.1 Lighting.json
Original file line number Diff line number Diff line change
@@ -0,0 +1,113 @@
{
"name": "(C) 90.1 Lighting",
"_description": "Incremental lighting energy savings and added costs from switching between BAU commercial code in 2021 (assume 90.1:2013) and current code (90.1:2019)",
"measure_type": "add-on",
"market_entry_year": 2025,
"market_exit_year": null,
"min_eff_elec_flag": null,
"ref_case_flag": null,
"climate_zone": "all",
"bldg_type": [
"assembly",
"education",
"food sales",
"food service",
"health care",
"lodging",
"large office",
"small office",
"mercantile/service",
"warehouse"
],
"structure_type": "all",
"end_use": "lighting",
"fuel_type": "electricity",
"fuel_switch_to": null,
"backup_fuel_fraction": null,
"technology": "all",
"htcl_tech_link": null,
"tech_switch_to": null,
"energy_efficiency": {
"assembly": 0.3,
"education": 0.2,
"food sales": 0.0,
"food service": 0.2,
"health care": 0.1,
"lodging": 0.2,
"large office": 0.2,
"small office": 0.2,
"mercantile/service": 0.2,
"warehouse": 0.3,
"other": 0.2,
"unspecified": 0.0
},
"energy_efficiency_units": "relative savings (constant)",
"energy_efficiency_source": {
"notes": [
"Based on comparison of lighting power densities in Table 9.5.1.",
"see full calculations at https://docs.google.com/spreadsheets/d/1tZHWcn0I0UGFjCTFRHccs_OGH5:WXufgDz5tN_TbHTc/edit?usp=sharing"
],
"source_data": {
"title": "Standard 90.1:2013 \u2013 Energy Standard for Buildings Except Low:Rise Residential Buildings",
"author": "ASHRAE",
"year": 2016,
"pages": null,
"url": "https://www.ashrae.org/technical:resources/bookstore/standard:90:1"
}
},
"installed_cost": {
"assembly": 2.0,
"education": 2.0,
"food sales": 0.0,
"food service": 1.2,
"health care": 2.0,
"lodging": 0.7,
"large office": 1.8,
"small office": 1.8,
"mercantile/service": 1.2,
"warehouse": 2.0,
"other": 1.8,
"unspecified": 1.8
},
"cost_units": "2020$/ft^2 floor",
"installed_cost_source": {
"notes": [
"Assumes incremental cost between 90.1:2013 and 90.1:2019 would be similar to that of 90.1:2016 and 90.1:2019",
"see full calculations at https://docs.google.com/spreadsheets/d/1tZHWcn0I0UGFjCTFRHccs_OGH5:WXufgDz5tN_TbHTc/edit?usp=sharing"
],
"source_data": {
"title": "National Cost:Effectiveness of ANSI/ASHRAE/IES Standard 90.1:2019",
"author": "Pacific Northwest National Laboratory",
"year": 2018,
"pages": [
64,
75
],
"url": "https://www.pnnl.gov/main/publications/external/technical_reports/PNNL:29940.pdf"
}
},
"add_elec_infr_cost": null,
"product_lifetime": 10.0,
"product_lifetime_units": "years",
"product_lifetime_source": {
"notes": "Typical commercial lighting technology lifetime, based on EIA NEMS buildings module raw data represented in Scout baselines",
"source_data": {
"title": "Scout technology cost, performance, and lifetime data",
"author": "U.S. Department of Energy",
"year": 2021,
"pages": null,
"url": "https://github.com/trynthink/scout/blob/master/supporting_data/stock_energy_tech_data/cpl_res_com_cz.json"
}
},
"market_scaling_fractions": null,
"market_scaling_fractions_source": {
"notes": null,
"source_data": null
},
"_updated_by": {
"name": "Aven Satre:Meloy",
"organization": "LBNL",
"email": "[email protected]",
"timestamp": "2025-09-24 13:39:06"
}
}
81 changes: 81 additions & 0 deletions ecm_definitions/(C) 90.1 Plug Loads.json
Original file line number Diff line number Diff line change
@@ -0,0 +1,81 @@
{
"name": "(C) 90.1 Plug Loads",
"_description": "Tier 1 advanced power strips applied to commercial workstations",
"measure_type": "add-on",
"market_entry_year": 2025,
"market_exit_year": null,
"min_eff_elec_flag": null,
"ref_case_flag": null,
"climate_zone": "all",
"bldg_type": [
"assembly",
"education",
"food sales",
"food service",
"health care",
"lodging",
"large office",
"small office",
"mercantile/service",
"warehouse"
],
"structure_type": "all",
"end_use": [
"PCs",
"non-PC office equipment"
],
"fuel_type": "electricity",
"fuel_switch_to": null,
"backup_fuel_fraction": null,
"technology": "all",
"htcl_tech_link": null,
"tech_switch_to": null,
"energy_efficiency": 0.11,
"energy_efficiency_units": "relative savings (constant)",
"energy_efficiency_source": {
"notes": "Tier 1 APS energy savings % for scheduling timer with load sensing",
"source_data": {
"title": "Grid-Interactive Efficient Building Technology Cost, Performance, and Lifetime Characteristics",
"author": "Nubbe et al.",
"year": 2020,
"pages": 88,
"url": "https://eta-publications.lbl.gov/sites/default/files/geb_technologies_data_report_final_v5_clean_ag_0.pdf"
}
},
"installed_cost": 0.1175,
"cost_units": "2020$/ft^2 floor",
"installed_cost_source": {
"notes": "Average of 'Total Cost (2020)' values for 'Tier 1 APS' ($23.5/unit), converted from $/unit to $/ft^2 floor assuming 1:1 ratio of APS:Occupant and 200 ft^2 floor/occupant, using large office reference case (498K sf, 2490 occupants, $58515 total cost per building)",
"source_data": {
"title": "Grid-Interactive Efficient Building Technology Cost, Performance, and Lifetime Characteristics",
"author": "Nubbe et al.",
"year": 2020,
"pages": 88,
"url": "https://eta-publications.lbl.gov/sites/default/files/geb_technologies_data_report_final_v5_clean_ag_0.pdf"
}
},
"add_elec_infr_cost": null,
"product_lifetime": 9.0,
"product_lifetime_units": "years",
"product_lifetime_source": {
"notes": "Average of low/high 'Average Life (yrs.)'",
"source_data": {
"title": "Grid-Interactive Efficient Building Technology Cost, Performance, and Lifetime Characteristics",
"author": "Nubbe et al.",
"year": 2020,
"pages": 88,
"url": "https://eta-publications.lbl.gov/sites/default/files/geb_technologies_data_report_final_v5_clean_ag_0.pdf"
}
},
"market_scaling_fractions": null,
"market_scaling_fractions_source": {
"notes": null,
"source_data": null
},
"_updated_by": {
"name": "Aven Satre:Meloy",
"organization": "LBNL",
"email": "[email protected]",
"timestamp": "2025-09-24 13:39:06"
}
}
144 changes: 144 additions & 0 deletions ecm_definitions/(C) 90.1-2022 Walls & Air Sealing.json
Original file line number Diff line number Diff line change
@@ -0,0 +1,144 @@
{
"name": "(C) 90.1-2022 Walls & Air Sealing",
"_description": "Commercial wall insulation and air sealing consistent with ASHRAE 90.1-2022 energy code levels.",
"measure_type": "full service",
"market_entry_year": 2025,
"market_exit_year": null,
"min_eff_elec_flag": null,
"ref_case_flag": null,
"climate_zone": "all",
"bldg_type": [
"assembly",
"education",
"food sales",
"food service",
"health care",
"lodging",
"large office",
"small office",
"mercantile/service",
"warehouse"
],
"structure_type": "all",
"end_use": [
"heating",
"cooling"
],
"fuel_type": "all",
"fuel_switch_to": null,
"backup_fuel_fraction": null,
"technology": [
"wall",
"infiltration"
],
"htcl_tech_link": null,
"tech_switch_to": null,
"energy_efficiency": {
"IECC_CZ1": {
"wall": 13.0,
"infiltration": 0.35
},
"IECC_CZ2": {
"wall": 16.8,
"infiltration": 0.35
},
"IECC_CZ3": {
"wall": 18.0,
"infiltration": 0.35
},
"IECC_CZ4": {
"wall": 20.5,
"infiltration": 0.35
},
"IECC_CZ5": {
"wall": 23.0,
"infiltration": 0.35
},
"IECC_CZ6": {
"wall": 25.5,
"infiltration": 0.35
},
"IECC_CZ7": {
"wall": 25.5,
"infiltration": 0.35
},
"IECC_CZ8": {
"wall": 31.8,
"infiltration": 0.35
}
},
"energy_efficiency_units": {
"wall": "R value",
"infiltration": "CFM/ft^2 @ 0.3 in. w.c."
},
"energy_efficiency_source": {
"notes": "Values for steel framed walls, insulation min. R value.",
"source_data": [
{
"title": "ASHRAE Standard 90.1-2022, Section 5.4.3.1.1: Whole:Building Air Leakage",
"author": "ASHRAE",
"year": 2022,
"pages": 55,
"url": null
},
{
"title": "ANSI/ASHRAE/IES Standard 90.1-2022: Table 5.5:1 through Table 5.5:8 for Steel:framed walls",
"author": "ASHRAE",
"year": 2022,
"pages": [
49,
50,
51,
52,
53,
54,
55,
56
],
"url": null
}
]
},
"installed_cost": {
"wall": 1.14,
"infiltration": {
"new": 0.0,
"existing": 0.876
}
},
"cost_units": {
"wall": "2022$/ft^2 wall",
"infiltration": "2022$/ft^2 wall"
},
"installed_cost_source": {
"notes": [
"Walls: Assume baseline wall cost from Scout data. Infiltration: Cost based on cost premium:per:% performance improvement implied by residential 'IECC : existing' air sealing measure. Using AIA CZ1 as a benchmark, the residential measure shows a cost premium of $0.42/ft^2 wall per 35% performance improvement in existing buildings in 2017",
"thus the cost premium to add to the baseline commercial infiltration cost of $0/ft^2 wall is $2.2/ft^2 wall in existing buildings ($0.42/ft^2 wall premium / 35% improvement)*(73% improvement for commercial infiltration in existing buildings in AIA CZ1 in 2017 (1 : 0.4/1.5)). New measure shows zero cost premium."
],
"source_data": {
"title": "Scout Baseline Envelope Characteristics Database",
"author": "U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Office",
"year": 2023,
"pages": null,
"url": "https://github.com/trynthink/scout/blob/master/scout/supporting_data/convert_data/cpl_envelope_mels.json"
}
},
"add_elec_infr_cost": null,
"product_lifetime": 100.0,
"product_lifetime_units": "years",
"product_lifetime_source": {
"notes": "Assumed equal to the lifetime of the building",
"source_data": null
},
"market_scaling_fractions": null,
"market_scaling_fractions_source": {
"notes": null,
"source_data": null
},
"_updated_by": {
"name": "Jared Langevin",
"organization": "LBNL",
"email": "[email protected]",
"timestamp": "2025-09-24 13:39:06"
}
}
Loading