Skip to content

open-ortho/edu.case.BFD9010

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

17 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

BFD9010

BFD9010: An HL7 FHIR API for Scanners

This software controls the Vidar professional scanners leveraging the proprietary 32-bit Windows DLL and exposes a local FHIR API for web-based scanning.

Development and deployment require Windows due to the 32-bit DLL dependency for scanner hardware access. Non-Windows platforms can build and run unit tests only.

Quick Start

Requires windows. Refer to the Deployment Checklist for installing on a fresh workstation.

  1. Download the latest release from GitHub.
  2. Run bfd9010.exe (GUI application).
    • The scanner will initialize automatically.
    • A small window will appear showing status.
    • The FHIR API server starts on http://localhost:5000.
  3. Navigate to https://wingate.case.edu/bfd9000/ to scan.

Option 1: GUI Application (Recommended for Web Integration)

C:\Users\afm\Downloads\bfd9010>bfd9000.exe
  • Launches the Windows Forms GUI
  • Automatically starts FHIR API server on http://localhost:5000
  • Displays scanner status in a small always-on-top window
  • Shows a clickable link to the web application (configured via WebAppUrl in INI file)
  • Best for production use with web-based scanner control

Screenshot of BFD9010

Option 2: CLI Application

C:\Users\afm\Downloads\bfd9010>bfd9000_cli.exe
  • Launches the interactive command-line interface
  • Provides manual control options via keyboard menu:
  • Best for testing and manual scanner control
Looking for Scanner...
Loading scan configuration from: C:\Users\afm\Downloads\bfd9010\scan_config.ini
Output configuration: Format=PNG, Path=C:\Users\afm\Desktop\VidarScans, Prefix=${DPI}DPI_${BIT}BIT
Reading Digitizer Capabilities...
Digitizer Info Retrieved


-------------------------------------------------------------
Digitizer model: DosimetryPRO Advantage
Serial Number: 341870
Firmware version number: 49.7
Hardware version number: 112
Current resolution = 44
Optical resolution = 570
Maximum width in inches = 14
Current Bit Depth = 16
Maximum number of films = 25
Dark Enhance not available
Line Filter not available
Film backup available
Single unloadMedium() command to eject film
Unlimited scans device
Line time range start = 4
Line time range end = 10
Line time current = 8

Feeder type is C (14 inches wide).
Lamp type is a red LED full width roller cartridge.
Translation table selection available.
Translation table location 0 set to Linear, location 1 set to LOG.
-------------------------------------------------------------



Welcome to BFD9010 Scanner Console!  (version: 1.0.1.5)
-------------------------------------------------------------
Available commands (press the key):
  [C]alibrate  - Calibrate the digitizer
  [E]ject      - Eject the film from the digitizer
  [S]can       - Initiate a scan using parameters from scan_config.ini
  [F]HIR API   - Start FHIR REST API server on http://localhost:5000
  [R]estart    - Re-detect scanner and reload configuration
  [Q]uit       - Exit the application
-------------------------------------------------------------
Enter a command: _

FHIR Server:

Enter a command: f

=================================================================
Starting FHIR API Server...
=================================================================
Loading scan configuration from: C:\Users\afm\Downloads\bfd9010\scan_config.ini
Output configuration: Format=PNG, Path=C:\Users\afm\Desktop\VidarScans, Prefix=${DPI}DPI_${BIT}BIT

Initializing scanner for FHIR API...
Loading scan configuration from: C:\Users\afm\Downloads\bfd9010\scan_config.ini
Output configuration: Format=PNG, Path=C:\Users\afm\Desktop\VidarScans, Prefix=${DPI}DPI_${BIT}BIT
Loading scan configuration from: C:\Users\afm\Downloads\bfd9010\scan_config.ini
Output configuration: Format=PNG, Path=C:\Users\afm\Desktop\VidarScans, Prefix=${DPI}DPI_${BIT}BIT
info: Microsoft.Hosting.Lifetime[14]
      Now listening on: http://localhost:5000
info: Microsoft.Hosting.Lifetime[0]
      Application started. Press Ctrl+C to shut down.
info: Microsoft.Hosting.Lifetime[0]
      Hosting environment: Production
info: Microsoft.Hosting.Lifetime[0]
      Content root path: C:\Users\afm\Downloads\bfd9010
info: BFD9010.FhirApi.Services.ScannerService[0]
      Initializing scanner...
Reading Digitizer Capabilities...
Digitizer Info Retrieved


-------------------------------------------------------------
Digitizer model: DosimetryPRO Advantage
Serial Number: 341870
Firmware version number: 49.7
Hardware version number: 112
Current resolution = 44
Optical resolution = 570
Maximum width in inches = 14
Current Bit Depth = 16
Maximum number of films = 25
Dark Enhance not available
Line Filter not available
Film backup available
Single unloadMedium() command to eject film
Unlimited scans device
Line time range start = 4
Line time range end = 10
Line time current = 8

Feeder type is C (14 inches wide).
Lamp type is a red LED full width roller cartridge.
Translation table selection available.
Translation table location 0 set to Linear, location 1 set to LOG.
-------------------------------------------------------------


info: BFD9010.FhirApi.Services.ScannerService[0]
      Scanner initialized successfully: DosimetryPRO Advantage

√ Scanner initialized successfully!

CORS configured for: https://wingate.case.edu

=================================================================
FHIR API Server is running on http://localhost:5000
=================================================================

Available endpoints:
  GET  /Device/{id}         - Get scanner information
  POST /Device/{id}/$scan   - Perform scan
  POST /Device/{id}/$calibrate - Calibrate scanner
  POST /Device/{id}/$eject  - Eject film

Web application: https://wingate.case.edu/bfd9000/

Press Ctrl+C to stop the server and return to menu...
=================================================================

When to use CLI:

  • Debugging scanner connectivity or status
  • Manual calibration/eject operations
  • Verifying scan output without the web UI

Command-line options (both CLI and GUI):

bfd9010_cli.exe --config path\to\config.ini
bfd9010.exe --config path\to\config.ini

CLI Usage

Run bfd9010_cli.exe for the interactive command-line interface.

Documentation

  • Build, run, packaging, configuration: documentation/BUILD_AND_RUN.md
  • FHIR API endpoints: documentation/API.md
  • Deployment checklist: documentation/DEPLOYMENT.md
  • Multi-scanner architecture: documentation/MULTI_SCANNER_ARCHITECTURE.md
  • Reverse engineering notes: documentation/vidar/RE_Writeup.md

Configuration File Structure

Example scan_config.ini:

[ScanParameters]

# Bit depth (8 or 16)
BitDepth = 16

# DPI resolution (tested DPIs: 75, 150, 300)
DPI = 300

# Output options
# OutputPath: directory where image files will be written
OutputPath = ~\Desktop\VidarScans

# OutputPrefix: filename prefix template. Tokens: ${DPI}, ${BIT}
OutputPrefix = ${DPI}DPI_${BIT}BIT

# Web API settings
# WebAppUrl: URL of the web application users should navigate to for scanning
WebAppUrl = https://wingate.case.edu/bfd9000/

# CorsOrigin: CORS origin(s) to allow API access from (comma-separated for multiple)
CorsOrigin = https://wingate.case.edu

Configuration Options

Option Type Default Description
BitDepth integer 16 Scan bit depth (8 or 16)
DPI integer 300 Scan resolution in dots per inch (tested: 75, 150, 300)
OutputPath string ~\Desktop\VidarScans Directory for saving scanned images (supports ~ for home directory)
OutputPrefix string ${DPI}DPI_${BIT}BIT Filename prefix template (tokens: ${DPI}, ${BIT})
WebAppUrl string https://wingate.case.edu/bfd9000/ URL displayed in GUI for users to access web interface
CorsOrigin string https://wingate.case.edu Allowed CORS origin(s), comma-separated for multiple origins

About

Python Module to Control Vidar Radiographic Film Scanners

Resources

Stars

Watchers

Forks

Packages

 
 
 