- Status of this document: alpha
- Editor: Yael Balbastre <y.balbastre at ucl.ac.uk>
- Version: 1.0a
A scalable format for large displacement or coordinates fields ("warps").
- Zarr is a format for the storage of chunked, compressed, N-dimensional arrays inspired by HDF5, h5py and bcolz.
- OME-NGFF (Next Generation File Format) is a format based on zarr for the storage of biomedical imaging data. It's version 0.6 specifies chains of geometric transformations, including coordinates and displacement fields.
- ITK is a C++ library for biomedical imaging processing, which implements its own set of transformation formats and algorithms. It is used by popular biomedical software, such as ANTs or 3DSlicer, making its transformation formats ubiquitous in the field.
- FSL is a package for the processing and analysis of neuroimaging data. It defines its own set of affine and nonlinear transformation formats. It is heavily used by the CMC project within CONNECTS.
The NIH-funded BRAIN CONNECTS consortium generates and analyses peta-bytes-scale images of the human brain. Some of the analysis steps involve estimating and applying geometric transformations to these images. Many transformation formats exist in the neuroimaging world, and none seems to have been accepted as a standard by the community. Furthermore, no format seems to scale to TB- or PB-scale datasets.
The Big Brain Imaging Analysis and Standardization Working Group (BBIAS), within the CONNECTS consortium is tasked with drafting and implementing a scalable format for large non linear transformations ("warps"), to be adopted by the consortium and the wider community.
Because it also targets large images and does specify a transformation format, this draft aligns as best as possible with the OME-NGFF v0.6 specification. However, it does highlight limitations and propose extensions to this format.
The NIfTI-1 format does list two intent codes related to coordinates and displacements fields:
#define NIFTI_INTENT_DISPVECT 1006 /* specifically for displacements */
#define NIFTI_INTENT_VECTOR 1007 /* for any other type of vector */ITK uses these intent codes when storing either displacements (1006) or coordinates (1007) fields,
as do all software built in top of ITK (Slicer, ANTs, etc).
ITK stores the coordinates or displacements in the LPS model space (x=right-to-left, y=anterior-to-posterior, z=inferior-to-superior),
with the NIfTI's affine used to encode a mapping from the vector field voxel grid to the LPS model space.
A RAS coordinate is transformed by an ITK transform via:
# coordinates field
[ x' ] [ -1 0 0 ] ( [ Axx Axy Axz ] [ x ] [ Tx ] )
[ y' ] = [ 0 -1 0 ] x LPSCoordinatesField( [ Ayx Ayy Ayz ] x [ y ] + [ Ty ] )
[ z' ] [ 0 0 +1 ] ( [ Azx Azy Azz ] [ z ] [ Tz ] )
v v v v v
RAS LPS2RAS RAS2VOX(Lin) RAS RAS2VOX(Tr)
# displacement field
[ x' ] [ x ] [ -1 0 0 ] ( [ Axx Axy Axz ] [ x ] [ Tx ] )
[ y' ] = [ y ] + [ 0 -1 0 ] x LPSDisplacementField( [ Ayx Ayy Ayz ] x [ y ] + [ Ty ] )
[ z' ] [ z ] [ 0 0 +1 ] ( [ Azx Azy Azz ] [ z ] [ Tz ] )
v v v v v v
RAS RAS LPS2RAS RAS2VOX(Lin) RAS RAS2VOX(Tr)
SPM also uses NIfTI files to store its warps, although it does not set the corresponding vector codes, and in contrast with ITK, it saves its coordinates in terms of the RAS model space (x=left-to-right, y=posterior-to-anterior, z=inferior-to-superior).
A RAS coordinate is transformed by an SPM transform via:
[ x' ] ( [ Axx Axy Axz ] [ x ] [ Tx ] )
[ y' ] = RASCoordinatesField( [ Ayx Ayy Ayz ] x [ y ] + [ Ty ] )
[ z' ] ( [ Azx Azy Azz ] [ z ] [ Tz ] )
v v v v
RAS RAS2VOX(Lin) RAS RAS2VOX(Tr)
FSL possesses its own NIfTI intent codes:
#define NIFTI_INTENT_FSL_FNIRT_DISPLACEMENT_FIELD 2006
#define NIFTI_INTENT_FSL_CUBIC_SPLINE_COEFFICIENTS 2007
#define NIFTI_INTENT_FSL_DCT_COEFFICIENTS 2008
#define NIFTI_INTENT_FSL_QUADRATIC_SPLINE_COEFFICIENTS 2009FSL always stores displacements (not absolute coordinates), and these displacements are in terms of "scaled voxels", not in terms of an abstract model space.
A RAS coordinate is transformed by an FSL transform via:
[ x' ] [ x ] [ Axx Axy Axz ] [ Sx 0 0 ] ^(-1) ( [ Axx Axy Axz ] [ x ] [ Tx ] ) [ Tx ]
[ y' ] = [ y ] + [ Ayx Ayy Ayz ] x [ 0 Sy 0 ] x ScaledDisplacementField( [ Ayx Ayy Ayz ] x [ y ] + [ Ty ] ) + [ Ty ]
[ z' ] [ z ] [ Azx Azy Azz ] [ 0 0 Sz ] ( [ Azx Azy Azz ] [ z ] [ Tz ] ) [ Tz ]
v v v v v v v v
RAS RAS VOX2RAS(Lin) Inverse Scale RAS2VOX(Lin) RAS RAS2VOX(Tr) VOX2RAS(Tr)
The v0.6 (currently v0.6rc0) of OME-NGFF introduces coordinates spaces and coordinates transformations. It defines a large range of transformation types, two of them being qualified as "warps": coordinates fields and displacement fields.
Because OME-NGFF does not commit to a specific organ, it stays clear of any mandatory model space (e.g. RAS vs LPS vs voxels). It is therefore the user's (or data creator) job to ensure the consistency of its spaces. In general, the common space of two transformations that compose are always exactly identical. This is slightly more complicated for displacement and coordinates field, because the input space is a voxel grid and, especially in the case of displacement fields, can lead to inconsistencies. Cleaning up these inconsistencies has been one of the main working points during the later stages of the 0.6 development.
When applied in a chain of transformations, i.e., within the "coordinatesTransformations" of an OME multiscales dataset, it has the form:
# coordinates
{
"type": "coordinates",
"path": "s3://bucket/path/to/coords.ome.zarr",
"interpolation": "bspline-cubic"
},
# displacements
{
"type": "displacements",
"path": "s3://bucket/path/to/disp.ome.zarr",
"interpolation": "bspline-cubic"
}The only interpolation methods currently supported by the specification are
"nearest", "linear", "bspline-cubic", and "windowed sinc".
The coordinates or displacements pointed to by "path" are full-fledged multiscales datasets, with metadata:
{
"ome": {
"version": "0.6rc0",
"name": "displacements",
"multiscales": [
{
"coordinateSystems": [
{
"name": "physical",
"axes": [
{"name": "c", "type": "displacement", "discrete": true},
{"name":"z", "type": "space", "unit": "micrometer"},
{"name":"y", "type": "space", "unit": "micrometer"},
{"name":"x", "type": "space", "unit": "micrometer"}
]
},
{
"name": "ras+",
"axes": [
{"name": "c", "type": "displacement", "discrete": true},
{"name":"z", "type": "space", "unit": "micrometer"},
{"name":"y", "type": "space", "unit": "micrometer"},
{"name":"x", "type": "space", "unit": "micrometer"}
]
}
],
"coordinateTransformations": [
{
"name": "phys2ras",
"input": "physical",
"output": "ras+",
"type": "affine",
"matrix": [ ... ]
}
],
"datasets": [
{
"path": "s0",
"coordinateTransformations": [
{
"type": "scale",
"scale": [1.0, sz, sy, sx],
"input" : {"path": "s0"},
"output" : {"name": "physical"}
}
]
}
]
}
]
}
}Multiple (and a least one) coordinateSystems can be defined in the same dataset.
The first system in the list is the "intrinsic" system, which is advised to be a scaled voxel space
(eventually translated -- but only to account for shifts across resolution levels). The last system in the list
is the default model space (e.g. used for visualisation by neuroglancer). Together with all coordinateTransformations
(at the within-dataset level, and the across-datasets level), they define a transformation from the
field's voxel space to the model space. This transformation must be invertible.
Note the the fact that the model space is named (and interpreted as) "ras+" is a choice we've made here, not a requirement from the specification. Assuming that the the model space is indeed RAS, and that the implied "voxel2tas" transformation is affine, an input RAS coordinate is transformed by an OME transform via:
# displacement
[ z' ] [ z ] ( [ Azz Azy Azx ] [ z ] [ Tz ] )
[ y' ] = [ y ] + DisplacementField( [ Ayz Ayy Ayx ] x [ y ] + [ Ty ] )
[ x' ] [ x ] ( [ Axz Axy Axx ] [ x ] [ Tx ] )
v v v v v
RAS RAS RAS2VOX(Lin) RAS RAS2VOX(Tr)
# coordinates
[ z' ] ( [ Azz Azy Azx ] [ z ] [ Tz ] )
[ y' ] = CoordinatesField( [ Ayz Ayy Ayx ] x [ y ] + [ Ty ] )
[ x' ] ( [ Axz Axy Axx ] [ x ] [ Tx ] )
v v v v
RAS RAS2VOX(Lin) RAS RAS2VOX(Tr)
Warning
Array dimensions in an OME-NGFF dataset must be ordered ([t], [c], [z], y, x). Axes within a coordinates system must also have this order. In other words, dimensions are transposed compared to conventions used in NIfTI and other neuroimaging tools. This means that the components of the field are also ordered as {z, y, x} (the first channel of the displacement field contains the displacement along the z axis).
We could either decide that (R, A, S) == (z, y, x) so that the input and output coordinates in the equation above remain "RAS", or keep (R, A, S) == (x, y, z) and learn to reverse our RAS vectors when computing the transformations. I lean towards the second solution.
Note
Although we have supposed here that the "voxel to model" transformation is affine, nothing mandates it in the OME-NGFF spec. The list of coordinates transformation in the displacement field's metadata could very well contain a (invertible) displacement field as well. The more general transformation equation becomes
output_model_coord = CoordinatesField( inv(voxel_to_model)(input_model_coord) )
This document proposes to leverage OME-NGFF displacements and coordinates fields for the CONNECTS common warp format, with the additional requirement that the output model space is (R, A, S) == (x, y, z). It recommends that the OME-NGFF RFC 4 be used to explictely encode this convention. It does not recommend that a specific unit be used (e.g. "mmRAS"), meaning that downstream users must check and adapt units when composing transformations that act on RAS coordinates spaces with different units.
Consequently, CONNECTS displacement and coordinates fields will be multiscales OME-NGFF datasets with metadata of the form:
{
"ome": {
"version": "0.6rc0",
"name": "displacements",
"multiscales": [
{
"coordinateSystems": [
{
"name": "physical",
"axes": [
{"name": "c", "type": "displacement", "discrete": true},
{"name":"z", "type": "space", "unit": "micrometer"},
{"name":"y", "type": "space", "unit": "micrometer"},
{"name":"x", "type": "space", "unit": "micrometer"}
]
},
{
"name": "ras+",
"axes": [
{"name": "c", "type": "displacement", "discrete": true},
{
"name": "z", "type": "space", "unit": "micrometer",
"orientation": {"type": "anatomical", "value": "inferior-to-superior"}
},
{
"name": "y", "type": "space", "unit": "micrometer",
"orientation": {"type": "anatomical", "value": "posterior-to-anterior"}
},
{
"name": "x", "type": "space", "unit": "micrometer",
"orientation": {"type": "anatomical", "value": "left-to-right"}
}
]
}
],
"coordinateTransformations": [
{
"name": "phys2ras",
"input": "physical",
"output": "ras+",
"type": "byDimension",
"transformations": [
{
"inputAxes": [1, 2, 3],
"outputAxes": [1, 2, 3],
"type": "affine",
"matrix": [
[Azz, Azy, Azx, Tz],
[Ayz, Ayy, Ayx, Ty],
[Axz, Axy, Axx, Tx]
]
}
]
}
],
"datasets": [
{
"path": "s0",
"coordinateTransformations": [
{
"type": "scale",
"scale": [1.0, sz, sy, sx],
"input" : {"path": "s0"},
"output" : {"name": "physical"}
}
]
}
]
}
]
}
}This is fully compatible with the OME-NGFF v0.6 specification, with the constraint that the model space is RAS+, and the voxel-to-RAS transformation is (at most) an affine transformation.
Displacement and coordinates transformations as defined in the v0.6 specification assume that the fields themselves are rather coarse, since a single resolution level is mandated and used. However, because they are full-fledged multiscales datasets, they easily lend themselves to multi-resolution extensions. Multi-resolution displacement fields may be needed when the algorithm that estimates them refines them at increasingly higher resolution. In such cases, the resoluting displacement fields can reach a resolution on par with that of the images that have been collected. Applying such large fields is computationnaly demanding; however, during visualization, only contant-size chunks of the deformed image ever need to be calculated, albeit at different resolution levels. The availability of different resolution levels of the same displacement field allows the visualization software to pick the transformation scale most suited to its current viewport, thereby greatly minimizing its memory footprint.
Such a multi-resolution displacement fields would have OME metadata of the form
{
"ome": {
"version": "0.6rc0",
"name": "displacements",
"multiscales": [
{
"coordinateSystems": [
{
"name": "physical",
"axes": [
{"name": "c", "type": "displacement", "discrete": true},
{"name":"z", "type": "space", "unit": "micrometer"},
{"name":"y", "type": "space", "unit": "micrometer"},
{"name":"x", "type": "space", "unit": "micrometer"}
]
},
{
"name": "ras+",
"axes": [
{"name": "c", "type": "displacement", "discrete": true},
{
"name": "z", "type": "space", "unit": "micrometer",
"orientation": {"type": "anatomical", "value": "inferior-to-superior"}
},
{
"name": "y", "type": "space", "unit": "micrometer",
"orientation": {"type": "anatomical", "value": "posterior-to-anterior"}
},
{
"name": "x", "type": "space", "unit": "micrometer",
"orientation": {"type": "anatomical", "value": "left-to-right"}
}
]
}
],
"coordinateTransformations": [
{
"name": "phys2ras",
"input": "physical",
"output": "ras+",
"type": "byDimension",
"transformations": [
{
"inputAxes": [1, 2, 3],
"outputAxes": [1, 2, 3],
"type": "affine",
"matrix": [
[Azz, Azy, Azx, Tz],
[Ayz, Ayy, Ayx, Ty],
[Axz, Axy, Axx, Tx]
]
}
]
}
],
"datasets": [
{
"path": "s0",
"coordinateTransformations": [
{
"input" : {"path": "s0"},
"output" : {"name": "physical"}
"type": "scale",
"scale": [1.0, sz, sy, sx],
}
]
},
{
"path": "s1",
"coordinateTransformations": [
{
"input" : {"path": "s1"},
"output" : {"name": "physical"}
"type": "sequence",
"transformations": [
{
"type": "scale",
"scale": [1.0, sz*2, sy*2, sx*2],
},
{
"type": "translation",
"scale": [0.0, sz/2, sy/2, sx/2],
},
]
}
]
},
...
]
}
]
}
}Note that because displacements and coordinates are defined in terms of model space (RAS) coordinates, downsampled levels can be computed using simple moving-average or gaussian-pyramid downsampling. The downsampled displacements do not need to be re-scaled.
- Boundary conditions when interpolating a warp are not specified in the specification. This matters particularly for cubic splines.
- Some of the interpolation orders used by FSL are not available in OME-NGFF (quadratic spline, DCT), which means that fields that use these orders cannot be converted losslessly to OME-NGFF.
- Furthermore, displacement [coordinates] fields must be saved in terms of "model space" displacements [coordinates], which again differs from FSL's "voxel space" displacements [coordinates]. This will also lead to numerical differences when interpolating the field.