Filt_N is a local constant, so the odd flag is unconditionally 0 regardless of the count parameter, which is only used in an assert. Configure relies on this call for the register - // WriteRegister(ODD_FIR, fir.coefficientsCount % 2); // set in SetFIRCoefficients - so nothing ever programs it correctly. Configure also writes the FIR tap parity into ODD_CFR, the CFR order register that UpdateHannCoeff already programs from cfr.order.
Activity
dmitrymmm commentedon Aug 3, 2026
Fix submitted in #376