@dmitrymmm

LMS7002M_SDRDevice::LMS7002TestSignalConfigure writes INSEL_RXTSP and then, if the Rx test signal is enabled, returns from the Rx branch:

if (ch.rx.testSignal.enabled)
{
    ...
    return chip.LoadDC_REG_IQ(TRXDir::Rx, ...);
}
chip.Modify_SPI_Reg_bits(INSEL_TXTSP, ch.tx.testSignal.enabled ? 1 : 0);

so the whole Tx half - including the INSEL_TXTSP write that would clear a previously enabled Tx test signal - is only reached when the Rx test signal is off. It runs for both channels on every board Configure.

Activity

  1. dmitrymmm commented on Aug 3, 2026

    @dmitrymmm
    ContributorAuthor

    Fix submitted in #376