Skip to content

Releases: ecristal/daphne_gui

DAPHNE GUI TOOL V2_04_04

09 Apr 12:39
Compare
Choose a tag to compare

Bugfix

  • Config file creation erases last component in vectors
  • Config file created when save checkbox is not checked

DAPHNE GUI TOOL V2_04_02

01 Apr 09:28
Compare
Choose a tag to compare

Minor corrections:

  • Added missing bias voltage to config.txt file.
  • Replaced fixed retry value 100 to spinBox value in align window.
  • Increased bias offset ranges to include negative values

DAPHNE GUI TOOL V2_04_00

14 Mar 17:09
Compare
Choose a tag to compare

New functionalities:

  • Configurations are save in a txt file.
  • Added memory to configurations in the main window.

Solved issues:

  • Aligment in DAPHNE V1

DAPHNE GUI TOOL V1_06_00

14 Mar 18:08
Compare
Choose a tag to compare
Added print config to .txt file

DAPHNE GUI TOOL V2_03_06

02 Nov 16:44
Compare
Choose a tag to compare

New functionalities:

  • Breakdown Voltage estimation from IV curve acquired data.
  • exception handler for bias and trim voltages.
  • Bias voltages are now set in units of Volts (previous in DAC).
  • Bias Menu allows to set bias correction offsets and Bias voltage limit (Vbias Control)

DAPHNE GUI TOOL V2_02_16 WIN64

04 May 12:36
Compare
Choose a tag to compare

patch: win64

  • Patched: AFE crashes in afe align process

DAPHNE GUI TOOL V2_02_14

31 Mar 17:33
Compare
Choose a tag to compare
  • Stable Release.
  • Improved general behaviour and stability.
  • Improved speed.
  • Known issues: GUI will freeze if sudden ethernet connection to DAPHNE is lost.

DAPHNE GUI TOOL V2_02_07

30 Mar 12:11
Compare
Choose a tag to compare
Pre-release
  • Unstable release.
  • Improved acquisition speed.
  • Solved: UDP binding message showing as internal GUI error.
  • Solved: GUI crashes when clicking OK in the Ethernet menu if the ethernet checkbox is selected.
  • Know issue: GUI may crash if autoset is pressed when RD FPGA is used with Multiwaveform unchecked.

DAPHNE GUI TOOL V2_02_01

27 Mar 09:55
Compare
Choose a tag to compare

DAPHNE GUI TOOL V2_02_01

-Adds support for FPGA selftrigger (work in progress).
-This version has known bugs that may crash program. Working on fixes
-Application will crash if a channel is selected in the mainwindow that was not checked in the acquisition menu. This happens if the mutiple
waveform is enabled.
- Application will crash if user hits ok in the ethernet menu while the ethernet checkbox is enabled.

  • Other known issue is that ethernet binding is displayed as an error. Ignore this message for now.

DAPHNE GUI TOOL V2_00_09

27 Nov 12:02
Compare
Choose a tag to compare

DAPHNE GUI TOOL

-This version includes support for DAPHNE V2A and DAPHNE V1 aligment and data acquisition.
-Minor changes to improve data acquisition such as signals to pause triggering while acquiring data, FPGA filtering options, etc.
-Visual improvements, added missing plugins.
-Directory selection is improved.