fuse filesystem interface to the Arexx BS-500 data logger. Copyright © 2013 John Hedges <[email protected]> Depends on libusb (>=1.0) and libfuse (>=2.9) To run $ arexxfs <mountpoint> A file is created in the mountpoint for each of the tempereature/humidity sensors. These files contain the raw 4-digit hex reading from the sensors. To convert the hex values to useful values see: http://www.algorithm-forge.com/techblog/2010/01/linux-usb-driver-for-the-arexx-tl-500-%E2%80%93-part-ii/ "Further investigation shows us that we can calculate the measurements from RH sensors by (0.6 + Rawdata * 0.03328) RH%, from temperature sensors TSN-TH70E by (-39.58 + Rawdata * 0.01) °C and from temperature sensors TL-3TSN by (Rawdata * 0.0078) °C. These coefficients are based on the the following linear regressions. With more data they will slightly change, but given the accuracy and that you need to calibrate your sensors either way, it’s a sufficient translation of uncalibrated sensor data." With thanks to Kornelius Rohmeyer for his work in decoding the tlx00 USB protocol: http://www.algorithm-forge.com/techblog/2009/12/using-libusb-to-write-a-linux-usb-driver-for-the-arexx-tl-500-part-i/ See License for licensing. See INSTALL for installation instructions. Bug reports to John Hedges <[email protected]>