Smart Meter / Switch KWS-303L ( Modbus / Modbus - RTU / RS-485 )

Review

My review of this device is here

General setup

Property Value
Baud rate 9600
Parity none
Stop bits 1
A red wire from RS 485 connector
B black wire from RS 485 connector

Holding registers - Modbus commands

Register Description R/W Bytes Example Gain
0 Connection Command R
1 Rated voltage (V)(220V) R 220V(Fixed) => 22000 100
2 Rated current (A) (40A) R 40A(Fixed) => 4000 100
5 Hardware version lower bits (display board) R 2 V0.8
14 Active Voltage (V) R 2 229.6V => 22960 100
18 Active Amperage (A) R 0.012A => 12 1000
26 Active Power (W) R 3.12W=> 312 100
34 ?? R
42 ?? R
48 Power Factor R 0.99 =>990 1000
51 Active Frequency (Hz) R 50Hz => 5000 100
55 Consumed Energy (kWh) R 5.5kWh => 5500 1000
60 Active Temperature (Co) R 25 1
61 Timing (minutes) R 100 => 100 1
63 Switch on / off relay R On/Off => 1 / 0
64 Over Voltage Limit (V) R 250V => 2500 10
65 Under Voltage Limit (V) R 85V => 850 10
66 Over Amperage Limit (A) R 26A => 260 10
67 Over Power Limit (W) R 11W => 110 10
71 Back Light time (minutes) R 6 1
72 Over Temperature Limit (Co) R 50 1
74 Over Energy Limit (kWh) R 12kWh=>1200 100
81 Screen Rotation R Normal/Rotated => 1/0
82 Black Light % R 80 1