Notifications
You must be signed in to change notification settings - Fork 52
Dedicated us inputs scenarios #181
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Merged
euronion
merged 47 commits into
PyPSA:master
from
open-energy-transition:dedicated_us_inputs_scenarios
Mar 14, 2025
Merged
Changes from 36 commits
Commits
Show all changes
47 commits
Select commit
Hold shift + click to select a range
82ac5da
code: introduce dedicated inputs and folders for the US
finozzifa df1761e
code: add manual input usa
finozzifa 6ff2f6c
code: latest changes to compile_cost_assumptions_usa.py
finozzifa fa53daa
code: latest changes to compile_cost_assumptions_usa.py - 2
finozzifa 7bc1619
code: relocate adjust_for_inflation to _helpers.py
finozzifa 6de5d2a
code: update costs in manual_input.csv
finozzifa c92def7
code: next step on compile_cost_assumptions_usa.py
finozzifa d1c4791
code: updates
finozzifa 5d214e4
code: add docstring
finozzifa 55990ec
code: pre-commit
finozzifa e02eec0
code: new updates to docstring
finozzifa f109fed
code: docstring
finozzifa 9b5a5aa
code: docstring in _helpers.py
finozzifa edf5f70
docu: update the release notes
finozzifa 41baba6
code: add unit tests
finozzifa 5cbe314
code: add pre-commit
finozzifa 082d710
Merge branch 'master' of https://github.com/PyPSA/technology-data int…
finozzifa ea373e7
code: sort outputs
finozzifa 0e77e31
code: add pre-commit
finozzifa cafe5fb
merge from master
finozzifa f492d7b
doc: add docstring
finozzifa 874102e
code: merge from master
finozzifa 3cbc206
code: re-import numpy and pandas in _helpers.py
finozzifa a445edf
add scenarios for H2 and DAC (US only) + apply inflation rate to EUR …
danielelerede-oet 27acc62
doc: update release notes
danielelerede-oet 1c2d04e
code: fix unit tests
finozzifa 2dfbab9
code-data: merge from master
finozzifa 7cb77e0
data: modify manual_input_usa.csv specifying financial_case R&D for r…
finozzifa fbc64ce
code: merge from master
finozzifa dc01499
Merge branch 'master' of https://github.com/PyPSA/technology-data int…
finozzifa 48d15ad
code: merge from master
finozzifa da782e1
add missing scenarios for electrolyzers
danielelerede-oet 5a602a8
code: merge from master
finozzifa ca7c084
Merge branch 'master' into dedicated_us_inputs_scenarios
finozzifa 78367f6
Merge branch 'master' into dedicated_us_inputs_scenarios
finozzifa 157ae02
pre-commit changes
finozzifa 927fcef
merge from master
finozzifa 0a05018
reorder manual_input_usa.csv
danielelerede-oet 9efff5a
add new files
finozzifa 0312582
Merge branch 'dedicated_us_inputs_scenarios' of https://github.com/op…
finozzifa e5c4065
Merge branch 'master' into dedicated_us_inputs_scenarios
finozzifa 853b641
fix financial case for ICCT technologies
danielelerede-oet 923e23e
ensure that financial case is correctly reported in output files
danielelerede-oet e278bf4
update unit test
danielelerede-oet 3b5a549
modify representative NREL technologies
danielelerede-oet 4419e62
include description of scenario and financial case
danielelerede-oet 7ae749a
code: resolve FutureWarning from set_specify_assumptions
finozzifa File filter
Filter by extension
Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
There are no files selected for viewing
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Large diffs are not rendered by default.
Oops, something went wrong.
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -1,7 +1,17 @@ | ||
| technology,parameter,value,unit,source,further description,currency_year,financial_case,scenario | ||
| Alkaline electrolyzer,FOM,0.04,%/year,ICCT IRA e-fuels assumptions ,,2022.0,, | ||
| Alkaline electrolyzer,FOM,0.04,%/year,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Moderate | ||
| Alkaline electrolyzer,FOM,0.04,%/year,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
|
||
| Market",Conservative | ||
| Alkaline electrolyzer,FOM,0.04,%/year,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Advanced | ||
| Alkaline electrolyzer,efficiency,0.65,p.u.,ICCT IRA e-fuels assumptions ,,,, | ||
| Alkaline electrolyzer,investment,1019.8742,USD/kW,ICCT IRA e-fuels assumptions ,,2022.0,, | ||
| Alkaline electrolyzer,investment,1146.0,USD/kW,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Moderate | ||
| Alkaline electrolyzer,investment,1471.0,USD/kW,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Conservative | ||
| Alkaline electrolyzer,investment,662.0,USD/kW,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Advanced | ||
| Alkaline electrolyzer,lifetime,30.0,years,ICCT IRA e-fuels assumptions ,,,, | ||
| Ammonia cracker,FOM,4.3,%/year,"Ishimoto et al. (2020): 10.1016/j.ijhydene.2020.09.017 , table 7.","Estimated based on Labour cost rate, Maintenance cost rate, Insurance rate, Admin. cost rate and Chemical & other consumables cost rate.",2015.0,, | ||
| Ammonia cracker,ammonia-input,1.46,MWh_NH3/MWh_H2,"ENGIE et al (2020): Ammonia to Green Hydrogen Feasibility Study (https://assets.publishing.service.gov.uk/government/uploads/system/uploads/attachment_data/file/880826/HS420_-_Ecuity_-_Ammonia_to_Green_Hydrogen.pdf), Fig. 10.",Assuming a integrated 200t/d cracking and purification facility. Electricity demand (316 MWh per 2186 MWh_LHV H2 output) is assumed to also be ammonia LHV input which seems a fair assumption as the facility has options for a higher degree of integration according to the report).,,, | ||
|
|
@@ -823,7 +833,7 @@ Fischer-Tropsch,carbondioxide-input,0.32,t_CO2/MWh_FT,ICCT IRA e-fuels assumptio | |
| Fischer-Tropsch,efficiency,0.7,per unit,ICCT IRA e-fuels assumptions ,,,, | ||
| Fischer-Tropsch,electricity-input,0.04,MWh_el/MWh_FT,ICCT IRA e-fuels assumptions ,"0.005 MWh_el input per FT output, output increasing from 2020 to 2050 (0.65, 0.7, 0.73, 0.75 MWh liquid FT output).",,, | ||
| Fischer-Tropsch,hydrogen-input,1.43,MWh_H2/MWh_FT,ICCT IRA e-fuels assumptions ,"0.995 MWh_H2 per output, output increasing from 2020 to 2050 (0.65, 0.7, 0.73, 0.75 MWh liquid FT output).",,, | ||
| Fischer-Tropsch,investment,1509724.4026,USD/MW_FT,ICCT IRA e-fuels assumptions ,"Well developed technology, no significant learning expected.",2022.0,, | ||
| Fischer-Tropsch,investment,1696429.0,USD/MW_FT,ICCT IRA e-fuels assumptions ,,2022.0,, | ||
| Fischer-Tropsch,lifetime,20.0,years,ICCT IRA e-fuels assumptions ,,,, | ||
| Gasnetz,FOM,2.5,%,"WEGE ZU EINEM KLIMANEUTRALEN ENERGIESYSEM, Anhang zur Studie, Fraunhofer-Institut für Solare Energiesysteme ISE, Freiburg",Gasnetz,2020.0,, | ||
| Gasnetz,investment,28.0,EUR/kWGas,"WEGE ZU EINEM KLIMANEUTRALEN ENERGIESYSEM, Anhang zur Studie, Fraunhofer-Institut für Solare Energiesysteme ISE, Freiburg",Gasnetz,2020.0,, | ||
|
|
@@ -2213,9 +2223,19 @@ Offshore Wind - Class 9,investment,4985.097885601565,USD/kW,NREL/ATB-https://dat | |
| Offshore Wind - Class 9,investment,4751.853123408093,USD/kW,NREL/ATB-https://data.openei.org/s3_viewer?bucket=oedi-data-lake&prefix=ATB%2Felectricity%2Fcsv%2F2022%2F,,2020.0,R&D,Advanced | ||
| Offshore Wind - Class 9,investment,5399.213615724163,USD/kW,NREL/ATB-https://data.openei.org/s3_viewer?bucket=oedi-data-lake&prefix=ATB%2Felectricity%2Fcsv%2F2022%2F,,2020.0,R&D,Conservative | ||
| Offshore Wind - Class 9,investment,4985.097885601565,USD/kW,NREL/ATB-https://data.openei.org/s3_viewer?bucket=oedi-data-lake&prefix=ATB%2Felectricity%2Fcsv%2F2022%2F,,2020.0,R&D,Moderate | ||
| PEM electrolyzer,FOM,0.04,%/year,ICCT IRA e-fuels assumptions ,,2022.0,, | ||
| PEM electrolyzer,FOM,0.04,%/year,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Moderate | ||
| PEM electrolyzer,FOM,0.04,%/year,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Conservative | ||
| PEM electrolyzer,FOM,0.04,%/year,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Advanced | ||
| PEM electrolyzer,efficiency,0.63,p.u.,ICCT IRA e-fuels assumptions ,,,, | ||
| PEM electrolyzer,investment,1220.1113,USD/kW,ICCT IRA e-fuels assumptions ,,2022.0,, | ||
| PEM electrolyzer,investment,1371.0,USD/kW,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Moderate | ||
| PEM electrolyzer,investment,2399.0,USD/kW,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Conservative | ||
| PEM electrolyzer,investment,447.0,USD/kW,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Advanced | ||
| PEM electrolyzer,lifetime,30.0,years,ICCT IRA e-fuels assumptions ,,,, | ||
| PHS,FOM,0.89,%/year,NREL/ATB-https://data.openei.org/s3_viewer?bucket=oedi-data-lake&prefix=ATB%2Felectricity%2Fcsv%2F2022%2F,,2020.0,Market,Advanced | ||
| PHS,FOM,0.89,%/year,NREL/ATB-https://data.openei.org/s3_viewer?bucket=oedi-data-lake&prefix=ATB%2Felectricity%2Fcsv%2F2022%2F,,2020.0,Market,Conservative | ||
|
|
@@ -3098,9 +3118,19 @@ SMR CC,capture_rate,0.9,per unit,"IEA Global average levelised cost of hydrogen | |
| SMR CC,efficiency,0.69,per unit (in LHV),"IEA Global average levelised cost of hydrogen production by energy source and technology, 2019 and 2050 (2020), https://www.iea.org/data-and-statistics/charts/global-average-levelised-cost-of-hydrogen-production-by-energy-source-and-technology-2019-and-2050",,,, | ||
| SMR CC,investment,605753.2171,EUR/MW_CH4,Danish Energy Agency,"Technology data for renewable fuels, in pdf on table 3 p.311",2015.0,, | ||
| SMR CC,lifetime,30.0,years,"IEA Global average levelised cost of hydrogen production by energy source and technology, 2019 and 2050 (2020), https://www.iea.org/data-and-statistics/charts/global-average-levelised-cost-of-hydrogen-production-by-energy-source-and-technology-2019-and-2050",,,, | ||
| SOEC,FOM,0.04,%/year,ICCT IRA e-fuels assumptions ,,2022.0,, | ||
| SOEC,FOM,0.04,%/year,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Moderate | ||
| SOEC,FOM,0.04,%/year,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Conservative | ||
| SOEC,FOM,0.04,%/year,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Advanced | ||
| SOEC,efficiency,0.82,p.u.,ICCT IRA e-fuels assumptions ,,,, | ||
| SOEC,investment,1389.2004,USD/kW,ICCT IRA e-fuels assumptions ,,2022.0,, | ||
| SOEC,investment,1561.0,USD/kW,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Moderate | ||
| SOEC,investment,2651.0,USD/kW,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Conservative | ||
| SOEC,investment,785.0,USD/kW,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Advanced | ||
| SOEC,lifetime,30.0,years,ICCT IRA e-fuels assumptions ,,,, | ||
| Sand-charger,FOM,1.075,%/year,"Viswanathan_2022, NULL","{'carrier': ['elec', 'sand'], 'technology_type': ['charger'], 'type': ['thermal'], 'note': ['Guesstimate, 50% on charger']}",2020.0,, | ||
| Sand-charger,efficiency,0.99,per unit,"Viswanathan_2022, p.107 (p.129)","{'carrier': ['elec', 'sand'], 'technology_type': ['charger'], 'type': ['thermal'], 'note': ['RTE assume 99% for charge and other for discharge']}",2020.0,, | ||
|
|
@@ -3760,13 +3790,23 @@ digestible biomass to hydrogen,FOM,4.25,%/year,"Zech et.al. DBFZ Report Nr. 19. | |
| digestible biomass to hydrogen,capture rate,0.9,per unit,Assumption based on doi:10.1016/j.biombioe.2015.01.006,,,, | ||
| digestible biomass to hydrogen,efficiency,0.39,per unit,"Zech et.al. DBFZ Report Nr. 19. Hy-NOW - Evaluierung der Verfahren und Technologien für die Bereitstellung von Wasserstoff auf Basis von Biomasse, DBFZ, 2014",,,, | ||
| digestible biomass to hydrogen,investment,4237.1194,EUR/kW_th,"Zech et.al. DBFZ Report Nr. 19. Hy-NOW - Evaluierung der Verfahren und Technologien für die Bereitstellung von Wasserstoff auf Basis von Biomasse, DBFZ, 2014",,2014.0,, | ||
| direct air capture,FOM,1.3,%/year,ICCT IRA e-fuels assumptions ,,2022.0,, | ||
| direct air capture,FOM,1.3,%/year,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Moderate | ||
| direct air capture,FOM,1.3,%/year,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Conservative | ||
| direct air capture,FOM,1.3,%/year,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Advanced | ||
| direct air capture,compression-electricity-input,0.15,MWh/tCO2,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",403.a Direct air capture,2020.0,, | ||
| direct air capture,compression-heat-output,0.2,MWh/tCO2,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",403.a Direct air capture,2020.0,, | ||
| direct air capture,electricity-input,0.24,MWh_el/t_CO2,ICCT IRA e-fuels assumptions ,,,, | ||
| direct air capture,heat-input,1.17,MWh_th/t_CO2,ICCT IRA e-fuels assumptions ,,,, | ||
| direct air capture,heat-output,1.25,MWh/tCO2,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",403.a Direct air capture,2020.0,, | ||
| direct air capture,investment,11034260.0394,USD/t_CO2/h,ICCT IRA e-fuels assumptions ,,2022.0,, | ||
| direct air capture,investment,12398844.91,USD/t_CO2/h,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Moderate | ||
| direct air capture,investment,19180739.93,USD/t_CO2/h,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Conservative | ||
| direct air capture,investment,7103597.31,USD/t_CO2/h,ICCT IRA e-fuels assumptions ,,2022.0,"R&D; and | ||
| Market",Advanced | ||
| direct air capture,lifetime,20.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",403.a Direct air capture,2020.0,, | ||
| direct air capture,years,30.0,years,ICCT IRA e-fuels assumptions ,,,, | ||
| direct firing gas,FOM,1.2121,%/year,"Danish Energy Agency, technology_data_for_industrial_process_heat.xlsx",312.a Direct firing Natural Gas: Fixed O&M,2019.0,, | ||
|
|
@@ -3829,7 +3869,7 @@ electrobiofuels,capture rate,0.9,per unit,Assumption based on doi:10.1016/j.biom | |
| electrobiofuels,efficiency-biomass,1.3183,per unit,Stoichiometric calculation,,,, | ||
| electrobiofuels,efficiency-hydrogen,1.0309,per unit,Stoichiometric calculation,,,, | ||
| electrobiofuels,efficiency-tot,0.6217,per unit,Stoichiometric calculation,,,, | ||
| electrobiofuels,investment,1028678.3556,EUR/kW_th,combination of BtL and electrofuels,,2022.0,, | ||
| electrobiofuels,investment,1155460.1124,EUR/kW_th,combination of BtL and electrofuels,,2022.0,, | ||
| electrolysis,FOM,4.0,%/year,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Fixed O&M ,2020.0,, | ||
| electrolysis,efficiency,0.5773,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Hydrogen Output,2020.0,, | ||
| electrolysis,efficiency-heat,0.2762,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: - hereof recoverable for district heating,2020.0,, | ||
|
|
@@ -3922,14 +3962,14 @@ hydro,investment,2574.060290445133,USD/kW,NREL/ATB-https://data.openei.org/s3_vi | |
| hydro,investment,2574.060290445133,USD/kW,NREL/ATB-https://data.openei.org/s3_viewer?bucket=oedi-data-lake&prefix=ATB%2Felectricity%2Fcsv%2F2022%2F,,2020.0,R&D,Conservative | ||
| hydro,investment,2574.060290445133,USD/kW,NREL/ATB-https://data.openei.org/s3_viewer?bucket=oedi-data-lake&prefix=ATB%2Felectricity%2Fcsv%2F2022%2F,,2020.0,R&D,Moderate | ||
| hydro,lifetime,80.0,years,IEA2010, from old pypsa cost assumptions,2015.0,, | ||
| hydrogen storage compressor,FOM,4.0,%/year,ICCT IRA e-fuels assumptions ,-,2022.0,, | ||
| hydrogen storage compressor,FOM,4.0,%/year,ICCT IRA e-fuels assumptions ,,2022.0,, | ||
| hydrogen storage compressor,compression-electricity-input,0.05,MWh_el/MWh_H2,"Based on Stöckl et al (2021): https://doi.org/10.48550/arXiv.2005.03464, table SI.4.",1.707 kWh/kg.,,, | ||
| hydrogen storage compressor,investment,2.0291,USD/kWh_H2,ICCT IRA e-fuels assumptions ,,2022.0,, | ||
| hydrogen storage compressor,lifetime,30.0,years,ICCT IRA e-fuels assumptions ,-,,, | ||
| hydrogen storage tank type 1,FOM,4.0,%/year,ICCT IRA e-fuels assumptions ,-,2022.0,, | ||
| hydrogen storage tank type 1,investment,15.0133,USD/kWh_H2,ICCT IRA e-fuels assumptions ,,2022.0,, | ||
| hydrogen storage tank type 1,lifetime,30.0,years,ICCT IRA e-fuels assumptions ,-,,, | ||
| hydrogen storage tank type 1,min_fill_level,6.0,%,"Based on Stöckl et al (2021): https://doi.org/10.48550/arXiv.2005.03464, table SI.9.",-,,, | ||
| hydrogen storage compressor,investment,2.28,USD/kWh_H2,ICCT IRA e-fuels assumptions ,,2022.0,, | ||
| hydrogen storage compressor,lifetime,30.0,years,ICCT IRA e-fuels assumptions ,,,, | ||
| hydrogen storage tank type 1,FOM,4.0,%/year,ICCT IRA e-fuels assumptions ,,2022.0,, | ||
| hydrogen storage tank type 1,investment,16.87,USD/kWh_H2,ICCT IRA e-fuels assumptions ,,2022.0,, | ||
| hydrogen storage tank type 1,lifetime,30.0,years,ICCT IRA e-fuels assumptions ,,,, | ||
| hydrogen storage tank type 1,min_fill_level,6.0,%,"Based on Stöckl et al (2021): https://doi.org/10.48550/arXiv.2005.03464, table SI.9.",,,, | ||
| hydrogen storage tank type 1 including compressor,FOM,1.0526,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",151a Hydrogen Storage - Tanks: Fixed O&M,2015.0,, | ||
| hydrogen storage tank type 1 including compressor,investment,60.3186,EUR/kWh,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",151a Hydrogen Storage - Tanks: Specific investment,2015.0,, | ||
| hydrogen storage tank type 1 including compressor,lifetime,25.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",151a Hydrogen Storage - Tanks: Technical lifetime,2015.0,, | ||
|
|
||
Oops, something went wrong.
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Uh oh!
There was an error while loading. Please reload this page.