Skip to content

Commit

Permalink
remove necb model_add_swh_end_uses_by_spaceonly method from hvac_systems
Browse files Browse the repository at this point in the history
This is overloaded in necb methods and doesn't belong in hvac_systems
  • Loading branch information
mdahlhausen committed Sep 23, 2021
1 parent 5481bc6 commit 06cba03
Showing 1 changed file with 0 additions and 45 deletions.
Original file line number Diff line number Diff line change
Expand Up @@ -6476,51 +6476,6 @@ def model_add_hvac_system(model,
rename_plant_loop_nodes(model)
end

# This method will add an swh water fixture to the model for the space.
# if the it will return a water fixture object, or NIL if there is no water load at all.
def model_add_swh_end_uses_by_spaceonly(model, space, swh_loop)
# Water use connection
swh_connection = OpenStudio::Model::WaterUseConnections.new(model)

# Water fixture definition
water_fixture_def = OpenStudio::Model::WaterUseEquipmentDefinition.new(model)

# water_use_sensible_frac_sch = OpenStudio::Model::ScheduleConstant.new(self)
# water_use_sensible_frac_sch.setValue(0.2)
# water_use_latent_frac_sch = OpenStudio::Model::ScheduleConstant.new(self)
# water_use_latent_frac_sch.setValue(0.05)
# Note that when water use equipment is assigned to spaces then the water used by the equipment is multiplied by the
# space (ultimately thermal zone) multiplier. Note that there is a separate water use equipment multiplier as well
# which is different than the space (ultimately thermal zone) multiplier.
rated_flow_rate_gal_per_min = OpenStudio.convert(space['shw_peakflow_ind_SI'], 'm^3/s', 'gal/min').get
water_use_sensible_frac_sch = OpenStudio::Model::ScheduleRuleset.new(model)
water_use_sensible_frac_sch.defaultDaySchedule.addValue(OpenStudio::Time.new(0, 24, 0, 0), 0.2)
water_use_latent_frac_sch = OpenStudio::Model::ScheduleRuleset.new(model)
water_use_latent_frac_sch.defaultDaySchedule.addValue(OpenStudio::Time.new(0, 24, 0, 0), 0.05)
water_fixture_def.setSensibleFractionSchedule(water_use_sensible_frac_sch)
water_fixture_def.setLatentFractionSchedule(water_use_latent_frac_sch)
water_fixture_def.setPeakFlowRate(space['shw_peakflow_ind_SI'])
water_fixture_def.setName("#{space['shw_spaces'].name.to_s.capitalize} Service Water Use Def #{rated_flow_rate_gal_per_min.round(2)}gal/min")
# Target mixed water temperature
mixed_water_temp_c = space['shw_temp_SI']
mixed_water_temp_sch = OpenStudio::Model::ScheduleRuleset.new(model)
mixed_water_temp_sch.defaultDaySchedule.addValue(OpenStudio::Time.new(0, 24, 0, 0), mixed_water_temp_c)
water_fixture_def.setTargetTemperatureSchedule(mixed_water_temp_sch)

# Water use equipment
water_fixture = OpenStudio::Model::WaterUseEquipment.new(water_fixture_def)
schedule = model_add_schedule(model, space['shw_sched'])
water_fixture.setFlowRateFractionSchedule(schedule)
water_fixture.setName("#{space['shw_spaces'].name.to_s.capitalize} Service Water Use #{rated_flow_rate_gal_per_min.round(2)}gal/min")
swh_connection.addWaterUseEquipment(water_fixture)
# Assign water fixture to a space
water_fixture.setSpace(space['shw_spaces']) if model_attach_water_fixtures_to_spaces?(model)

# Connect the water use connection to the SWH loop
swh_loop.addDemandBranchForComponent(swh_connection)
return water_fixture
end

# Add a residential ERV: standalone ERV that operates to provide OA,
# use in conjuction witha system that having mechanical cooling and
# a heating coil
Expand Down

0 comments on commit 06cba03