-
Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathsubsection_EIT_applications_Four_main__.tex
More file actions
8 lines (5 loc) · 2.66 KB
/
subsection_EIT_applications_Four_main__.tex
File metadata and controls
8 lines (5 loc) · 2.66 KB
1
2
3
4
5
6
7
8
\subsection{EIT applications}
Four main data collection strategies were identified for EIT experiments fig \ref{Modes}. The most common method of data collection in EIT is time difference, where multiple data sets are obtained at different points in time, \emph{i.e.} before and after the introduction of some perturbation, and the change in impedance over time is reconstructed. Such is the prevalence of this method, it can be considered the 'standard' mode of operation, being used in the vast majority of successful experiments in the field \cite{bayford2012bioimpedance}.
The second method is time difference imaging, using an external triggered stimulus to allow for coherent averaging. Data collection is synchronised to an external stimulus (e.g. whisker stimulator in rats, or visual EPs in humans) which is also recorded. This method, first developed by \citet{Oh2011} is used when impedance signals have low signal to noise ratio (SNR) and millisecond duration. Current is continuously injected, while the stimulus is repeated, generating multiple evoked potentials at different time points. Through coherent averaging, an impedance signal is obtained at each sample interval, yielding millisecond resolution.
In certain applications such as stroke \cite{Romsauerova2006} or breast imaging \cite{Halter}, where it is not possible to obtain a reference frame, the change in tissue impedance over frequency is instead reconstructed. To collect Multi frequency EIT data a complete injections protocol is repeated for a number of frequencies, commonly 10 or 20, sufficient to capture the differences in tissue spectra. The ordering of frequencies can be fixed, or randomised and the injection period of each particular frequency can be specified. Composite waveforms, consisting of multiple frequencies such as those implemented in the existing KHU \cite{Hun_Wi_2014} and UCL \cite{McEwan_2006} systems, can also be generated. These methods are substantially less robust to modelling and instrumentation errors than standard EIT methods, and thus place more stringent requirements on the algorithms and hardware \cite{Ahn2011} \cite{Malone2014}.
The final data collection method is a frequency sweep. While not directly used for EIT imaging, this method has previously been used to assist EIT experiments, allowing for impedance characterisation in-situ taking the place of a stand-alone impedance analyser \cite{Gabriel_2009}, and selecting an optimal measurement frequency \cite{VongerichtenASantosGAristovichK2013}. The injection frequency is incremented over a given range and step size, with measurements taken at each point. Both increasing and decreasing sweeps are possible, as is randomised ordering.