diff --git a/docs/Smart-Meter-Interface.md b/docs/Smart-Meter-Interface.md index 189bdf1dee..df1920fda2 100644 --- a/docs/Smart-Meter-Interface.md +++ b/docs/Smart-Meter-Interface.md @@ -1267,8 +1267,43 @@ The current power and counter in high resolution are available after PIN entry w 1,77070100010800ff@1000,Zaehlerstand,kWh,Counter,6 1,77070100100700ff@1,Verbrauch,W,Power,1 # + ``` +### EasyMeter M60 V14.02 (SML) + +Communication with the EasyM electricity meter occurs serially via two infrared data interfaces (DSS). The baud rate is 9600 Baud (8N1). +All telegrams are encoded using the SML transport protocol (V1.04). + +The electricity meter is a 3-Phase AC meter that can handle two tarifs as well as counters from the grid and what was delivered to the grid. +When the PIN is entered more information is available on via the INFO-DSS like Voltage and Power per Phase. + + +There are two communication interfaces: + + * INFO-DSS: Unidirectional infrared interface. Permanently outputs (every second) billing-relevant measured values and other information. (used for the script) + * MSB-DSS: Bidirectional infrared interface. Permanently outputs (every second) billing-relevant measured values and other information. Additionally, the MSB interface is used for setting meter parameters and controlling tariffs. (Not tested/ used for the script) + +For the counter value precision 1 is used for the rest i only took the numbers without any decimal points + +??? summary "View script" ``` + >D + >B + =>sensor53 r + >M 1 + +1,3,s,16,9600,ESY + 1,77070100010800ff@1000,Zaehlerstand,kWh,Bezug_Summe,1 + 1,77070100020800ff@1000,Einspeisung,kWh,Einspeisung_Summe,1 + 1,77070100100700ff@1,Verbrauch,W,Leistung_Total,0 + 1,77070100240700ff@1,L1,W,Leistung_L1,0 + 1,77070100380700ff@1,L2,W,Leistung_L2,0 + 1,770701004c0700ff@1,L3,W,Leistung_L3,0 + 1,77070100200700ff@1,U1,V,Spannung_L1,0 + 1,77070100340700ff@1,U2,V,Spannung_L2,0 + 1,77070100480700ff@1,U3,V,Spannung_L3,0 + # + ... + ### EasyMeter Q1D (ASCII OBIS) This script is for the EasyMeter Q1DB1004 variant of the Q1D series. This variant is a one-phase one-way electricity counter with a backstop mechanism.