Notifications
You must be signed in to change notification settings - Fork 5
/
Copy pathpooldb.py
137 lines (106 loc) · 5.09 KB
/
pooldb.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
#!/usr/bin/python
# Set systemwide loglevel here:
# INFO
# WARN
# DEBUG
loglevel = "INFO"
__author__ = 'Richard J. Sears'
VERSION = "V3.5.0 (2019-02-16)"
""" Config file for Pool_Fill_Control"""
check_url = 'www.google.com'
# Set DB here to read pump watts (only) from DB via emoncms or
# set NODEJS to use Russ Goldin's nodeJS Pump control software
# https://github.com/tagyoureit/nodejs-poolController
PUMP_DATA = "NODEJS"
PUMP_DATA_URL = "http://localhost:3000/pump"
PUMP_DATA_TEST_URL = "localhost:3000"
PUMP_START_URL = "http://localhost:3000/pumpCommand/run/pump/1"
PUMP_STOP_URL = "http://localhost:3000/pumpCommand/off/pump/1"
PUMP_PROGRAM1_URL = "http://localhost:3000/pumpCommand/run/pump/1/program/1"
PUMP_PROGRAM2_URL = "http://localhost:3000/pumpCommand/run/pump/1/program/2"
PUMP_PROGRAM3_URL = "http://localhost:3000/pumpCommand/run/pump/1/program/3"
PUMP_PROGRAM4_URL = "http://localhost:3000/pumpCommand/run/pump/1/program/4"
## Pool temperature Sensor Settings
pool_temp_table = "feed_53"
pool_temp_sensor_temp_table = "feed_54"
pool_temp_sensor_battery_table = "feed_52"
pool_temp_sensor_humidity_table = "feed_55"
pool_temp_sensor_low_voltage = 2.9
max_pool_temp_sensor_time_delta = 3000
## What is the table name for our pool_level feed and other settings for our pool_level_sensor?
pool_level_table = "feed_81"
pool_level_sensor_battery_table = "feed_80"
pool_level_sensor_humidity_table = "feed_83"
pool_level_sensor_temp_table = "feed_82"
# Settings for Power & Solar if using Solar Module to manage pump
power_total_use = "feed_49"
power_importing = "feed_42"
power_solar = "feed_46"
# Other temp sensors if you are using them....
garage_temp_sensor_humidity_table = "feed_69"
garage_temp_sensor_battery_table = "feed_70"
garage_temperature_table = "feed_68"
attic_temp_sensor_battery_table = "feed_74"
attic_temperature_table = "feed_75"
# At what voltage do we consider the pool_level_sensor to have low batteries?
pool_level_sensor_low_voltage = 2.9
# After how many seconds of no database activity from our pool_level_sensor do we consider it offline?
max_pool_level_sensor_time_delta = 2000
# How many Pool Level Sensor Timeouts before we do something?
max_pool_level_sensor_timeouts = 10
# How long to allow the pool to fill before sending an error? (in minutes)
max_pool_fill_time = 130
# How long to fill the pool each time we ask Alexa to fill it...
alexa_max_pool_fill_time = 60
# What is the table name for our pool resistance?
pool_resistance_table = "feed_56"
## What is the table name for our pool_running_watts feed?
pump_running_watts_table = "feed_24"
## What is the table name for our pool_filter_psi?
pool_filter_psi_table = "feed_67"
pool_filter_max_psi = 20
pool_filter_max_psi_reset = 15
#pool acid realert time: How many minutes between low acid alerts do we want?
pool_acid_alert_max_minutes = 2880
# How many gallons have we used to fill the pool?
pool_gallons_total = "feed_65"
## Do we have a pool water sensor and are we tracking the pool water temp? (Generally user for accurate pH readings).
temp_probe = "Yes"
temp_probe_table = "feed_53"
## This is for our pH and ORP probes. This is the information needed to store our pH and ORP reading to our
## two emoncms servers
##
## Do we want to use or do we have the pH and ORP probes installed?
ph_probe = "Yes" # Yes or No
ph_node = int(40)
#ph_node = "pool_ph" # This will be the Node_ID that shows up in your inputs if logging to emoncms
ph_probe_baud = 38400
orp_probe = "Yes" # Yes or No
orp_node = int(41)
#orp_node = "pool_orp" # This will be the Node_ID that shows up in your inputs if logging to emoncms
orp_probe_baud = 9600
## Do we have multiple emoncms servers and do we want them turned on...?
# Server 1 Information
emoncms_server1 = "No"
server1 = "emonpi" # This could be an IP address, localhost, or an FQDN
emoncmspath1 = "emoncms" # This is the path, for example if you want http://www.yourdomain.com/emoncms/
# you would put "emoncms" here.
apikey1 = "api_key_here"
# Server 2 Information
emoncms_server2 = "No"
server2 = "phx-emoncms"
emoncmspath2 = ""
apikey2 = "api_key_here"
# Used for Sprinkler Bypass
sprinkler_bypass = "Yes" # Set this to "No" to disable all sprinkler checks
sprinkler_type = "Rachio" # Timer or Rachio - sprinkler_bypass must be set to "Yes" for this to make any difference
# If you have a Rachio Sprinkler System, this is the curl request to get the sprinkler status.
# You must have your own system, you must get your Auth:Bearer ID as well as you device ID
# from Rachio in order to use this subprocess.
rachio_url = 'curl -s -X GET -H "Content-Type: application/json" -H "Authorization: Bearer jjsjdjjds-skksdkkdk-yyey" https://api.rach.io/1/public/device/device_id/current_schedule'
## Set the MAXIMUM idle wattage of your pool pump/equipment. If the reading is over this wattage, the pool will not fill since the
## pump would be running. If you do not care if your pump is running while you are filling your pool, set this super high, like 5000.
max_wattage = 100
## Do we have a MightyHat installed with an LCD screen and if so, do we want to output mesages to the LCD screen?
MightyHat = "True"