You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
M1 is an inductive load hooked up to transistor Q1 without any reverse voltage protection. It's possible that the motor is small enough that any voltage spikes it would create are small enough to not harm Q1, but this is neither documented or handled. Would you please either add a protection diode to the motor in the plans or document the lack of a need for a protective diode?
The text was updated successfully, but these errors were encountered:
M1 is an inductive load hooked up to transistor Q1 without any reverse voltage protection. It's possible that the motor is small enough that any voltage spikes it would create are small enough to not harm Q1, but this is neither documented or handled. Would you please either add a protection diode to the motor in the plans or document the lack of a need for a protective diode?