Skip to content

What are the units for pep_patch_electrostatic patch areas? #44

@DavidBJaffe

Description

@DavidBJaffe

Thank you for creating this wonderful program!

I've been running pep_patch_electrostatic on Fv parts of antibodies using -o patches.csv. The area column in patches.csv typically maxes out at 4 or 5. But what are the units?

From reading the paper, I thought it was in Å^2. And in the code I see

        '-s','--size_cutoff',
        type=float,
        default=0.,
        help='Restrict output to patches with an area of over s A^2.

which makes me think the area is indeed in Å^2. However, the reported area values seem about 100 times too small for that to make sense.

Elsewhere in the code I see

    def as_plydata(self, text=True, units_per_angstrom=0.1):
        """Convert to a plyfile.PlyData object, while scaling coordinates

        the default scaling units_per_angstrom=0.1 matches the PyMol CGO
        scaling factor of 1:100 and the nm -> A conversion.

which might explain the factor of 100.

So are the units for the reported area values actually (10^-7m)^2, rather than Å^2?