diff --git a/doc/Paderborn.md b/doc/Paderborn.md index ba2cc72..bea48ed 100644 --- a/doc/Paderborn.md +++ b/doc/Paderborn.md @@ -99,6 +99,16 @@ experiments. | 2 | 1500 | 0.1 | 1000 | N15_M01_F10 | | 3 | 1500 | 0.7 | 400 | N15_M07_F04 | +### Table 7. Operating parameter of healthy (undamaged) bearings during run-in period. + +| Bearing Code | Run-in Period [h] | Radial Load [N] | Speed [min^-1] | +| :---: | :---: | :---: | :---: | +| K001 | >50 | 1000-3000 | 1500-2000 | +| K002 | 19 | 3000 | 2900 | +| K003 | 1 | 3000 | 3000 | +| K004 | 5 | 3000 | 3000 | +| K005 | 10 | 3000 | 3000 | +| K006 | 16 | 3000 | 2900 | ## 3.使用情况 * Bin Hasan M. Current based condition monitoring of electromechanical systems. Model-free drive system current monitoring: faults detection and diagnosis through statistical features extraction and support vector machines classification.[D]. University of Bradford, 2013.