Skip to content

Latest commit

 

History

History
67 lines (45 loc) · 2.5 KB

04_EPFL_RRL_VALIDATION.md

File metadata and controls

67 lines (45 loc) · 2.5 KB

Modular / Origami / Soft Robotics Validation Pathway

1. Purpose

MorphoSNN needs embodied validation because body-near control can only be evaluated through physical or physics-aware interaction. Local rhythm generation, reflex-like correction, prediction error, modulation, and morphology-aware behavior should be tested in settings where body structure and contact dynamics matter.

This document describes a general validation pathway for morphology-aware physical AI. It is not a partner-specific plan and does not claim any committed validation work.

2. Why Modular, Origami, and Soft Robotics

Modular, origami, and soft robotics are useful validation contexts because they expose control systems to morphology-dependent behavior:

  • reconfigurable morphology;
  • compliance;
  • distributed actuation;
  • surface-based interaction;
  • physical deformation;
  • contact-rich adaptation.

These properties make them useful for testing whether a body-near control layer can remain interpretable and measurable under changing physical conditions.

3. Validation Questions

  • Can local rhythm generation remain stable under morphology changes?
  • Can reflex-like correction reduce perturbation error?
  • Can a forward model identify mismatch between predicted and observed sensory outcomes?
  • Can neuromodulation shift behavior without rewriting the local controller?
  • Can morphology reduce control burden?

4. Candidate Validation Scenarios

Candidate public validation scenarios include:

  • terrain perturbation;
  • contact-rich surface adaptation;
  • reconfigurable module coordination;
  • compliant object interaction;
  • morphology transfer.

These scenarios should be treated as proposed benchmark directions until implementations, baselines, and measured results exist.

5. Measurement Targets

Potential measurement targets include:

  • response latency;
  • perturbation recovery;
  • trajectory deviation;
  • contact/force envelope violation;
  • rhythm stability;
  • morphology transfer success;
  • event/spike activity proxy.

No numeric targets are defined at this stage. Targets should be set only after baseline measurement.

6. Current Status

This is a proposed validation pathway for the seed repo, not a completed validation result. The current public repository defines concepts, documentation, and initial benchmark scaffolding.

7. Non-goals

This document does not include:

  • partner-specific confidential data;
  • unpublished hardware details;
  • a claim of validated real-world performance;
  • a guarantee of deployment readiness.