diff --git a/src/modality-specific-files/microelectrode-electrophysiology.md b/src/modality-specific-files/microelectrode-electrophysiology.md index 8ee92fac73..ab94b03be1 100644 --- a/src/modality-specific-files/microelectrode-electrophysiology.md +++ b/src/modality-specific-files/microelectrode-electrophysiology.md @@ -308,6 +308,8 @@ This file contains the following information: - The electrode coordinates in 3 columns (`xyz`) (use `n/a` for values if a dimension is absent). - The ID of the probe the electrode is located on +The electrode `name` MUST be unique within the `*_electrodes.tsv` file. When a dataset contains multiple probes, electrode names can be constructed by combining the contact identifier (as provided by the probe manufacturer or principal investigator) with the `probe_name` to ensure uniqueness. For example, if two probes each have a contact labeled "1", the electrode names could be "probe01_e1" and "probe02_e1" to distinguish them. + {{ MACROS___make_columns_table("microephys.microephysElectrodes") }} ### Electrode Position Coordinates