Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathgeneral-reactor.lua
More file actions
157 lines (133 loc) · 5.7 KB
/
general-reactor.lua
File metadata and controls
157 lines (133 loc) · 5.7 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
on_tick = function (event)
-- read in variables
coreTemp = rednet["signal-reactor-core-temp"]
if coreTemp == nil then
coreTemp = 0
end
powerOutput = rednet["signal-reactor-power-output"]
if powerOutput == nil then
powerOutput = 0
end
CoolantReserve = rednet["water"]
if CoolantReserve == nil then
CoolantReserve = 0
end
Starting = rednet["signal-state-starting"]
if Starting == nil then
Starting = 0
end
Stopping = rednet["signal-state-scramed"]
if Stopping == nil then
Stopping = 0
end
Running = rednet["signal-state-running"]
if Running == nil then
Running = 0
end
Stopped = rednet["signal-state-stopped"]
if Stopped == nil then
Stopped = 0
end
Steam = rednet["steam"]
if Steam == nil then
Steam = 0
end
--'Constants' *** SET THESE FOR THE SPECIFIC HARDWARE DESIGN ***
PumpPowerMatrix = {60, 80, 100, 120, 130} -- Thermal power draw at each stage of pump activation.
PumpSignalMatrix = {"signal-A", "signal-B", "signal-C", "signal-D", "signal-E"} -- Signals to output to activate each level of pumps
MaxPeakLoadTemp = 980 -- Temp to switch on all pumps, regardless of other considerations.
CoolingTemp = 985 -- Temp to start ECS
ScramTemp = 990 -- Temp to shutdown the core
CoolantCutoff = 14000 --Coolant level below which to scram the core regardless
TargetPowerOutput = 125 -- Target thermal output from the reactor, in MW
SteamShutdownLevel = 400000 -- 255 seconds rounded up to 400k (1380 * 255 sec. Gives a buffer for shutdown, and startup, plus room for surplus steam during shutdown)
SteamStartupLevel = 82800 -- 60 seconds (1380 steam for 60 sec = 54000)
ECSPumpSignal = "signal-exmark"
LightSignal = "signal-L"
--Wipe the outputs to reset them all
output = {}
--Set delay. High precision when risk is high otherwise use less UPS
if coreTemp >= MaxPeakLoadTemp then
delay = 1
else
delay = 12
end
-- Setup Complete
-- auto startup & shutdown code
if Running > 0 then
--if steam level is nearly full then shutdown
if Steam > SteamShutdownLevel then
output["signal-control-scram"] = 1
end
elseif Stopped > 0 then
--if steam level is low, startup again
if Steam < SteamStartupLevel and CoolantReserve > CoolantCutoff then
output["signal-control-start"] = 1
end
end
-- Always do these thermal control measures:
--Turn on all heat exchanger pumps when the Maximum nominal temperature is reached, or we're at the max power draw level
if coreTemp > MaxPeakLoadTemp then
for i = 1, #PumpSignalMatrix do
output[PumpSignalMatrix[i]] = 1
end
end
--Activate emergency cooling when appropriate
if coreTemp > CoolingTemp then
output[ECSPumpSignal] = 1
end
--Scram the core when appropriate
if coreTemp > ScramTemp then
output["signal-control-scram"] = 1
end
--Scram the core if coolant reserve is getting too low
if CoolantReserve < CoolantCutoff then
output["signal-control-scram"] = 1
end
--[[
The compicated bit. The aim here is to be able to support a wide range of power outputs, but turning pumps on progressively.
At each stage, the pumps to only cool the reactor by a bit less than it's thermal output, in order to allow the reactor to keep heating up.
Once the reactor reaches it's design power output level, then the last pump kicks on and off to keep the reactor at that point.
This loop assumes that TargetPowerOutput is a value between the last two values in the PumpPowerMatrix table.
--]]
for i = 1, #PumpPowerMatrix do
if powerOutput >= PumpPowerMatrix[i] then
-- the power exceed this level of pumps. The pumps should be turned on if either, we're halfway to the next pump level, or we're over the targetpower output
if i < #PumpPowerMatrix then -- this is here to avoid an out of index error in the next if statement. But if it's false then current power exceeds pump capacity!
if powerOutput >= (PumpPowerMatrix[i] + PumpPowerMatrix[i + 1]) / 2 then
-- then turn on this pump and all lower pumps
for j = 1, i do
output[PumpSignalMatrix[j]] = 1
end
end
if i == (#PumpPowerMatrix - 1) then -- if there's only one pump left, we can't afford to exceed it's cooling capacity.
if powerOutput > (PumpPowerMatrix[i] + PumpPowerMatrix[i + 1]) / 2 then -- check to see if we're over halfway to to reaching the final pump
output[PumpSignalMatrix[i+1]] = 1 -- if we are, turn on the next pump
end
end
else
-- if we get here, and powerOutput >= PumpPowerMatrix[i], then the pumps can't cool enough. Turn on all pumps and the Emergency Cooling System.
-- pumps first.
for j = 1, #PumpSignalMatrix do
output[PumpSignalMatrix[j]] = 1
end
-- then the ECS
output[ECSPumpSignal] = 1
end
else
-- if power output is less than this pump level, then we can stop checking.
break
end
end
--Control the lights
if Starting + Stopping + Running > 0 then
output[LightSignal] = 1
end
if Starting > 0 then
output["signal-yellow"] = 1
elseif Stopping > 0 then
output["signal-red"] = 1
elseif Running == 1 then
output["signal-green"] = 1
end
end