Skip to content

Latest commit

 

History

History
362 lines (273 loc) · 37.8 KB

CHANGELOG.md

File metadata and controls

362 lines (273 loc) · 37.8 KB

Changelog

All notable changes to the Wiser Home Assistant integration, newest release first.

For releases before v3.3.5, see the Full Change Log on our wiki.

v4.1.0

Upgrade notes

  • Light configuration selectors now report translation keys such as auto, manual, last_brightness and specified_brightness. Update automations that compare their states; service calls using the previous API option values remain accepted - issue #790.
  • Smart-plug Mode selectors now report auto and manual states. Update automations that compare their states; service calls using Auto and Manual remain accepted - issue #795.
  • Existing native Passive Mode enablement, temperature increment, lower schedules and active lower overrides migrate automatically. Set up legacy experimental External Passive Mode again after upgrading. Obsolete external control switches are removed automatically. PR #766
  • This diagnostic beta does not modify the entity registry. It adds read-only information needed to investigate duplicate and unavailable entities after upgrading to v4.

Added

  • Added Heating active (one per heating channel) and Hot water active binary sensors with the running device class, so circuit state shows as an on/off timeline in history. They share their logic with the existing Heating and Hot water text sensors, which are retained for compatibility - issue #822.
  • Downloaded diagnostics now include entity naming inputs and device names to help investigate entity ID regeneration - PR #817.
  • Added per-channel dimmable-light output-mode and power-on brightness controls where supported, and exposed target, manual and scheduled brightness attributes on all lights with API support - issue #790.
  • Added translated smart-plug LED indicator controls on compatible hubs and APIs, plus next scheduled start and end dates on plug switches where available - issue #795.
  • Added a translated output-type selector for compatible heating actuators, supporting Relay and Pilot wire where the hub and API provide control - issue #797.
  • Added optional Wiser climate controls under UI options on Home Assistant 2026.7 and later. Native Thermostat cards and More Info show Wiser room demand, Passive Mode colours, and boost countdowns.
  • Added Bottom and responsive Inline control layouts to the native Thermostat card editor for Wiser rooms.
  • OpenTherm hot water reports localized heating activity and the next scheduled temperature in Home Assistant’s display units.
  • Enabling OpenTherm hot water control saves editable 15-, 30- and 45-minute presets when no timed presets are configured. Existing enabled setups without timed presets receive the defaults automatically.
  • The OpenTherm preset selector shows the remaining time during an active timed boost.
  • Stored hot water switches report when a boost is active and when it ends.
  • Administrators can export Wiser panel settings to one JSON file and selectively restore individual panels, tab order, and titles. Import and export are available from the desktop panel menu.
  • Added a Notifications tab for native Wiser power, device, and automation notifications. With compatible hub and API support, administrators can manage notification settings and view, enable, disable, or delete Wiser automations.
  • Optional Equipment sensors now include standalone equipment reported by the hub, such as EV chargers, and expose additional control, schedule, and rated power data where available.
  • Added External Room Control for compatible Home Assistant heating climates, with one Wiser room per climate across all hubs. PR #766
  • Added optional temperature sensor feedback for rooms with a Wiser TRV and no native Wiser temperature sensor. A fresh reading below the scheduled target can trigger a configurable fixed or proportional timed boost in Auto. #619
  • Added per-room Modulating and Temperature limiter strategies, plus per-period Passive Mode settings and paired schedule limits. PR #766

Fixed

  • Advance Schedule applies the next period's Passive Mode enablement, strategy and paired limits across refreshes, until the next schedule transition or Cancel Overrides.
  • Normalize legacy smart-plug, light and heating-actuator select service values before Home Assistant validates the translated options, retaining existing automation calls.
  • Allow existing OpenTherm preset lists expanded by automatic timed defaults through options-form validation while retaining the normal ten-preset limit.
  • Preserve remembered OpenTherm connection and hot-water capabilities when the optional boiler endpoint returns no data; clear them only when the hub explicitly reports OpenTherm disabled.
  • On OpenTherm hubs, the Heating text sensor and Heating active binary sensor now follow the boiler's central-heating-active status instead of relay/demand output. Missing status stays unknown, and disconnected OpenTherm circuits become unavailable. Relay hubs retain their channel output logic - issue #822.
  • Circuit text and binary sensors handle missing heating channels and hot water without reading stale states or raising missing-object errors - issue #822.
  • Added disabled-by-default diagnostic Signal strength (dBm) and Link quality sensors for every Zigbee device, sourced from the hub's controller reception RSSI and LQI, Wi-Fi signal strength sensor (dBm) for the HeatHub, supporting long-term statistics alongside the existing text Signal sensor - issue #820.
  • Failed hub refreshes now mark entities unavailable and propagate cancellation correctly.
  • Room climate entities preserve unknown heating readings instead of reporting idle or an off control output when the API cannot determine OpenTherm heating activity.
  • Restored compatibility with Home Assistant 2025.5 for custom selector schemas and hub device naming while preserving newer Home Assistant APIs.
  • Entity ID regeneration now uses the updated hub name after renaming a Wiser hub - PR #817.
  • Fixed Passive Mode Temperature limiter control overwriting temperature changes made on the Wiser hub or app. These changes now update the lower-limit override until the next scheduled period.
  • Preserved channel labels in translated light configuration controls so multi-gang devices remain distinguishable - issue #790.
  • Preserved Temperature limiter hysteresis across reloads and restarts, and removed cooling-mode restrictions on target updates and restoration for assigned heating-capable TRVs.
  • The OpenTherm preset editor blocks saving temperatures outside the boiler's reported minimum and maximum while keeping numeric input.
  • If the hub is unreachable when an OpenTherm boost expires, the integration retries the return to Manual after the hub recovers. A delayed boiler rejection also triggers one more attempt without restoring the expired preset.
  • Stored hot water boost actions refresh the selected hub and reject a hub that is no longer loaded.

Changed

  • Passive Mode demand now shows Modulation or Limiter. OpenTherm and relay-controlled rooms continue to show a demand percentage.
  • The Thermostat card editor preview uses dashboard card sizing so the controls wrap as they do on the dashboard.
  • Updated hot water More Info controls and added a heating glow when hot water is active.
  • Schedule copies carry Passive Mode metadata, and panel and service calls share limiter assignment validation. Advance Schedule applies both limiter thresholds from the next slot, and scheduled mode changes preserve manual boosts. PR #766
  • Local builds produce an unpacked integration alongside the ZIP. A build replaces an existing unpacked directory only when it matches the previous ZIP. PR #766
  • Updated the aioWiserHeatAPI dependency from v1.7.8 to v1.7.9.
  • Light mode, power-on behaviour, LED indicator and output-mode selectors show translated option descriptions instead of raw API values - issue #790.
  • Smart-plug Mode options now use translated descriptions while preserving their API command values - issue #795.
  • Expanded downloaded Wiser diagnostics with entity-registry metadata, including entity IDs, unique IDs, associated device records and creation times - issue #792.

v4.0.2

Upgrade notes

  • The room climate preset_modes list now uses translation keys such as boost_1h and advance_schedule. Update templates and custom cards that compare entries in this list to the old English labels. Existing preset service calls using the old labels still work.

Added

  • Added battery sensors for Wiser wireless button panels when the hub reports usable battery information, including combined dimmer/button-panel devices - issue #691, PR #743.
  • Added missing entity names across supported languages.

Changed

  • Updated the aioWiserHeatAPI dependency from v1.7.3 to v1.7.7, using its native room heat-demand and button-panel battery support. Dev builds prefer a published API prerelease and fall back to the released API pin; local builds can explicitly use a manually installed API, while final integration releases always use the released pin - PR #754.

Fixed

  • Fixed room climate and target-temperature entities displaying Wiser's internal -20 °C off sentinel when Away Mode is configured to turn heating off - issue #783.
  • Fixed logical room devices being inconsistently identified as Controller and retaining the HeatHub firmware version after upgrading. Room entities now report consistent Room metadata, and existing device-registry records are repaired during setup - issue #782.
  • Fixed shared Wiser services and Lovelace resources remaining registered after the final hub was removed, and ensured multi-hub service handlers are rebound to a loaded hub after another hub unloads.
  • Removed use of the deprecated config-flow connection-class constant ahead of its removal in Home Assistant 2027.5; the integration's local-polling classification remains declared in its manifest - issue #772.
  • Updated climate and water-heater temperature properties for Home Assistant 2026.11 while retaining compatibility with older supported Home Assistant releases - issue #770.
  • Fixed numeric discovery suffixes causing an already-configured Wiser hub to be offered as a new integration - Issue #692.
  • Fixed preset-mode icons not appearing for Wiser room climate entities in Home Assistant thermostat cards - issue #767.
  • Fixed rooms without heating capability incorrectly creating climate entities - issue #762.
  • Fixed the integration failing to load when Home Assistant temporarily has mixed aiofiles package files during dependency installation, and removed the schedule export service's reliance on the API importing aiofiles.os - issue #763.
  • Fixed Advance Schedule failing when the next heating period is off - issue #657.
  • Fixed 3.x upgrades hashing room entity unique IDs before they could be matched to their stable room IDs. Existing room temperature, target-temperature, heating-demand, window-detection, Include in Summer Comfort and passive-mode entities are now retained, and affected 4.0.x registries are repaired on setup. Inactive NothingAssigned rooms left behind by retired devices are now excluded consistently so they cannot recreate duplicate room entities after migration - issue #759.
  • Fixed battery sensors raising an error during hub refresh when a battery-powered device temporarily disappears.
  • Fixed the Zigbee network failing to load when multi-function or multi-gang devices expose several logical endpoints with the same physical Zigbee node ID - PR #750.

v4.0.1

Fixed

  • Fixed device switches, such as Identify, breaking the hub refresh when the hub briefly stops reporting their device. The switch now shows as unavailable until the device returns - PR #752.

v4.0.0

Breaking changes

  • The device registry is restructured. The separate virtual controller device is merged into the physical hub device, and Wiser room devices move to stable identifiers. In both cases the old device is removed and its entities are reassigned to the surviving device. Entity IDs and history are preserved, but anything that targets a Wiser device rather than an entity - device-based automations and scripts, or dashboard cards pointing at a device - needs repointing - PR #693, issue #733, PR #734.
  • Entity unique IDs migrate to deterministic UUIDv5. The migration runs automatically on upgrade and renames registry entries in place, including light capability entities, so entity IDs, history, and customisations are preserved. Every target is checked before any change is applied, so it cannot partially apply, but it aborts if it finds a unique ID collision - take a backup before upgrading - PR #693, PR #723.
  • Downgrading is not supported. Because unique IDs and device identifiers change, returning to a 3.x release means restoring the backup taken before upgrading, not just reinstalling the older version.
  • The detailed Equipment diagnostic sensor is now optional and off by default for compatible Gen 2 devices, including existing installations. Normal power, energy, current and voltage entities remain enabled. To restore the additional entity and its telemetry attributes, enable Equipment sensors in the integration options; the option appears only when the hub reports compatible equipment - issue #758, PR #726.
  • Room climate entities only report the demand_type attribute when OpenTherm is enabled. On systems without OpenTherm it is no longer present, so update any templates or automations that use it. percentage_demand is still reported on all systems - PR #724.
  • The Heating, Heating channel and Hot Water circuit state sensors now report the standard Home Assistant states on and off instead of On and Off, and show as unknown when the hub reports neither. The displayed state is unchanged, but templates and automations that compare against On or Off must use the lowercase values - issue #711, PR #721.

Added

  • Added Schneider Mureva EV Link charger entities - issue #689, PR #749.
  • Added smoke alarm operating states and a report count sensor - PR #744.
  • Added scheduled setpoint sensors, showing the current schedule temperature for Wiser rooms without climate control. Rooms are chosen under Additional sensors in the automation options - issue #738, PR #746.
  • Added optional Wiser-only OpenTherm domestic-hot-water control with a Home Assistant water-heater entity, configurable temperature and presets, an optional external current-temperature sensor, icon mode controls, and an integration-owned weekly schedule managed from the Wiser Schedules panel. Non-timed presets can be used in schedule periods; temporary boost presets remain manual actions - PR #745.
  • Added configurable OpenTherm monitoring and controls, including relative modulation, a Delta-T sensor, daily flame runtime statistics counted from local midnight, boiler capacity and estimated boiler output sensors, expanded telemetry, and categorized diagnostics. OpenTherm options and entities only appear on systems with an OpenTherm boiler - PR #697, PR #701, PR #715, issue #735, PR #729.
  • Added an is_calling_for_heat attribute to room climate entities on OpenTherm systems - PR #724.
  • Added PowerTag Control equipment sensors - PR #726.
  • Added a single Wiser sidebar panel with a custom sidebar icon and tabs for Schedules, Zigbee, Controls and Hub. It is shown by default and can be hidden with Show Wiser in sidebar in the integration's UI options - PR #708, PR #719.
  • Added the Wiser Controls card, a dashboard card for heating, stored and OpenTherm hot water, shutters, lights, dimmers and smart plugs, with room controls, schedule information and bulk actions. It is also available as the Controls tab of the Wiser panel - PR #719.
  • Added the Wiser Hub panel, a Wiser panel tab giving an overview, live controls, diagnostics and recent history charts for each hub - PR #719.
  • Added an integration-managed frontend registry (cards.json), so the Schedule, Zigbee and Controls cards and the Wiser panel tabs install and update independently through Home Assistant update entities, with offline caching and a shared panel-settings API - PR #709, PR #719.
  • Added a Hot Water on/off switch entity, attached to the hub device - issue #626, PR #682, PR #704.
  • Added a UFH controller measured-temperature sensor - issue #628.
  • Added optimistic light state for instant UI feedback on toggles, kept stable across rapid repeated toggles - PR #684.
  • Added British English translations and corrected the German, French, and English integration translations - PR #708.
  • Added Danish, Spanish, Finnish, Hungarian, Norwegian, Dutch, Portuguese, and Swedish translations - PR #747.

Changed

  • Entity naming now follows Home Assistant conventions, using has_entity_name so Home Assistant composes each displayed name from the device name plus the entity name. Existing entity IDs are not renamed. A new Legacy naming option controls whether Wiser room names are included in device names; it is switched on automatically for existing installations, so your device names stay as they are unless you turn it off. New installations on Home Assistant 2026.8 and later default it to off. Light and dual-relay channels are named from the physical device, and single-channel lights do not repeat a channel name - PR #693, PR #700, issue #666.
  • Wiser devices are now placed in Home Assistant areas matching their Wiser room, creating the area if it does not exist. This applies only to devices that have no area yet, so any area you assigned manually is left untouched - PR #693, PR #700.
  • Card and panel bundles are no longer stored in the source repository. Release packages include them, and each card or panel updates from its own repository through a Home Assistant update entity - PR #716.
  • Card versions are now detected from the installed card bundles instead of being pinned in the integration, so card updates no longer need an integration release - PR #708.
  • OpenTherm hot-water temperature changes made in Auto mode now act as temporary overrides and are replaced by the next scheduled period - PR #745.

Fixed

  • Fixed Wiser room renames and removals creating duplicate or orphaned devices and entities. Physical devices and logical rooms now use stable identifiers, existing registry records are migrated while retaining entity IDs and history, integration-managed area assignments follow room renames, user-selected areas remain unchanged, and deleted rooms are removed after confirmation - issue #732.
  • Fixed passive mode for underfloor heating rooms - issue #641, PR #742.
  • Improved light and smart plug responsiveness: commands are no longer blocked by a hub refresh, stale confirmations are retried, obsolete ones are cancelled, and smart plug state updates immediately after a command - issue #666, PR #725.
  • Fixed Hub V1 installations creating unsupported Hub V2 system sensors - PR #731.
  • Fixed system binary sensors not updating - issue #736, PR #737.
  • Reintroduced the previous Power and Energy entities, corrected equipment data naming on v2 hubs, and added an active state for the window/door sensor - issue #677, PR #690.
  • Fixed multi-gang dimmer lights breaking select, binary_sensor, switch, and sensor entities - issue #681, PR #683.
  • Preserved light entities across the multi-gang unique_id migration - issue #681, PR #683.
  • Fixed the device signal sensor to emit once per physical device instead of once per light channel on multi-gang dimmers - issue #681, PR #683.
  • Fixed the room Window Detection Active binary sensor being presented as a physical window sensor. It carried a window device class, so Home Assistant displayed it as Open/Closed as though it reported a real window, when it actually reports whether the room's window-detection feature is switched on. It now shows a plain on/off state. The underlying state values are unchanged, so automations that test for on/off keep working - only the displayed wording and icon change - PR #703.
  • Fixed away mode and frost protection reporting distinct target temperatures, and the frost protection target now honours the configured value - PR #693.
  • Fixed room stat and iTRV battery values not always being reported correctly - issue #662, PR #680.

v3.4.20

  • Added equipment data to smart plugs, heating actuators, and PowerTag E devices.
  • Added LED-indicator support for on/off and dimmable lights.
  • Added seasonal-comfort controls, including the target lift for shutters.
  • Added an option to hide the hot-water schedule in the Wiser Schedule Card.
  • Fixed the controller signal sensor to use the HeatHub name - issue #639.
  • Fixed schedule deletion and schedule-name inputs on current Home Assistant releases - issue #461.

v3.4.19

  • Fixed: Breaking change in HA 2026.2 causes integration not to load - issue #643
  • Fixed: V2 hubs with firmware lower than 4.42.23 cannot connect on https

v3.4.18

  • Fixed no long term stats for temp/humidity sensors issue #598
  • Fixed deprecated ZeroconfServiceInfo - issue #612
  • Fixed error 500 when selecting integration config - issue #613
  • Fixed unable to create new schedule card - issue #616
  • Fixed schedule card badges are misaligned - issue #615
  • Changed: Communication to v2 hub now uses https over internal network
  • Bumped schedule card to v1.5.0
  • Bumped api to v1.7.0

v3.4.17

  • Fixed hot water climate does not respect away mode - issue #579
  • Fixed deprecation error sets option flow config_entry explicitly - issue #595
  • Fixed schedule card unable to edit - issue #607

v3.4.16

  • Fix incorrect identifer on hub device
  • Fix deprecation warning for access to lovelace resource parameters
  • Fix error on unloading services for hubs without hot water control
  • Fix deprecation warning for ZeroconfServiceInfo
  • Bump api to v1.6.6 to support SSL for future firmware

v3.4.15

  • Added experimental hw climate mode to operate differently. See wiki for details
  • Changed min/max hw climate temp range from 40-80C to 10-80C - issue #545
  • Fixed issue whereby hw climate errors if temp sensor not available after HA start - issue #541
  • Fixed issue whereby hw climate config requires some entry in the temp sensor select option, even if not enabled - issue #544
  • Fixed issue whereby hw min does not change when setting both via service call if temps are 1C or less different - issue #547

v3.4.14

  • Fixed issue causing integration not to load in some circumstances due to failed config entry migration - issue #539
  • Added binary sensor active state sensor

v3.4.13

  • Added support for PowerTag C - issue #528
  • BREAKING CHANGE - refactored HW climate automation - issues #481, #490. See wiki for updated instructions
  • Added illuminance, humidity and temp sensors to devices with threshold sensors - issue #531
  • Added support for 2 gang light switch - issue #529
  • Added interacts with room climate switch to supported devices
  • Fixed support for Binary sensors with threshold sensors - issue #530
  • Fixed incompatibility with Python3.13 and HA2024.12 - issue #535
  • Fixed events not correctly firing for climate changes - issue #526
  • Fixed error when saving schedule with an off slot - issue #536
  • Changed all hot water related sensors to now belong to a hot water device
  • Bumped aiowiserheatapi to v1.6.3

v3.4.12

  • Fixed issue assigning schedules with non ascii characters in name - issue #509
  • Fixed error when using HotWater climate automation - issue #517
  • Fixed wiser http path not registering - issue #521
  • Fixed issue causing integration to fail loading with BoilerInterface - issue #523
  • Added support for ButtonPanel (Wiser Odace) - issue #524
  • Bump api to v1.5.19 to resolve issues #509, #523, #524

v3.4.11

  • Bump api to v1.5.18 to reduce Payload not completed errors
  • Fix typo in dimable light color mode - issue #518

v3.4.10

  • Fixed error loading sensors - issue #513

v3.4.9 (Pulled)

  • Fixed smoke alarm naming issue - issue #496
  • Set humidity to Unavailable if no value - issue #503
  • Add support for BoilerInterface - issue #499
  • Add support for WindowDoorSensor for v2 hub
  • Add support for CFMT device for v2 hub - issue #507

v3.4.8

  • Fix deprecation warning no waiting on setups - #485
  • Fix color mode issue - #479
  • Added smoke alarm sensors - #457
  • Fixed missing save layout button in zigbee card - #488

v3.4.7

  • Bump api to v1.5.14 to improve handling of hub connection errors
  • Fix - improve handling of hub update failures - #434
  • Fix - set entity values to unknown if not provided in the hub update - #471
  • Fix - removed use of async_add_job - #463
  • Fix - add color modes to lights - #458
  • Fix - use default boost temp with presets - #467
  • Add ability to unassign a schedule via the assign schedule service - #470

v3.4.6

  • Bump api to v1.5.13 to improve retry handling to include hub conneciton error
  • Prevent entities going unavailable if hub update failed
  • Fix issue with floor temp offset slider not loading
  • Fix hass.components.websocket_api deprecation warning in HA 2024.3 (issue #455)
  • Fix unique ids not unique error when changing configuration options
  • Add new automation to control hot water with a climate entity and an external temperature sensor on your water tank by @markchalloner. See wiki for more info.

v3.4.5

  • Bump api to v1.5.12 to improve performance of improved retry handling
  • Fixed issue caused by v3.4.4 that heating actuators and power tags error on load (issue #449, #450)
  • Fixed error setting up integration in config flow caused by session parameter being passed when no longer required (issue #446)
  • Fixed issue on 3 channel hubs with Heating sensor names
  • Fixed issue with signal sensor showing unknown on startup until first refresh
  • Changed preset icon to HA standard

v3.4.4

  • Bump api to v1.5.11
  • Improved api retry handling for inconsitant errors coming from the hub causing errors in the log and entities to go unavailable (issues #434, #436, #439)
  • Fixed Validation of translation placeholders error for German language (issue #434
  • Fixed diagnostic download failure (issue #444)
  • Fixed error with wall plugs not providing power data (issue #446)
  • Set state of target temp sensors to Unavailable when the climate HVAC mode is off (issue #447, #378)
  • Added ability to set a different IP port for hub - PR#430 - thanks @simick
  • Enabled statistics on batteries - PR#445 - thanks @msalway
  • Added number_of_trvs, number_of_trvs_locked and is_roomstat_locked attributes to climate entities (issue #374)

v3.4.3

  • Fixed Warning error in logs caused by new HA2024.2 requirement to explicity support Turn On/Off for climate entities (issue #435)
  • Bump api to v1.5.7 to fix issue setting lower target temp when in passive mode

v3.4.2

  • Reverted to using aiohttp for communication and resolved issues caused by HA2023.12
  • Bumped api to v1.5.5
  • Fixed issue where hub communication would error due to command characters in payload (issue #418)
  • Updated schedule card to allow hiding of hot water schedule (issue #415)
  • Included version in card resources to improve updating of new versions
  • Added more v2 hub features and attributes
  • Improved error handling/logging when hub offline and command is issued

v3.4.1

  • Corrected error deleting schedule
  • Handle space at end of secret key and prevent error (issue #409)
  • Updated schedule card to v1.3.2 - fixed some UI bugs, added ability to hide info and assignments via config (issue #404)

v3.4.0beta

  • Fixed issue in HA 2023.12 with errors reading hub
  • Add PowerTagE support (v2 hub)
  • Add tilt functions for shutters (v2 hub)
  • Fixed issue whereby non ASCII chars are removed in device/room names - issues #396

v3.3.11

  • Add check for overrides to prevent turning off away modewhen selecting cancel overrides when none exist (Wiser hub bug)
  • Correct sensor device class and native values to fix history not displaying issue in HA 2023.11

v3.3.10

  • bump api to v1.3.8 to fix passive mode error if room trv/roomstat goes offline
  • make battery sensor unavailable if no battery info provided by hub (previously showed 0%)
  • add uptime and last reset reason to Hub signal sensor
  • make LTS sensors normal sensors instead of diagnostic sensors so they show in Area card - issue #381
  • save schedule service will now create directory for file if it doesn't exist
  • correct relative modulation level magnitude

v3.3.9

  • bump api to v1.3.5 to fix warning regarding async not awaited on extra config

v3.3.8

  • Fix extra key issue preventing loading on HA 2023.8.0 and above

v3.3.7

  • Fix issue with zigbee card unable to save layout in stack card
  • Updated libraries for schedule card to fix security vulnerabilities
  • Fix colours missing on on/off schedule in schedule card
  • Minor UI improvements in schedule card

v3.3.6

  • Improved Zigbee network card

v3.3.5

  • Fix for eroneous current temp if lost signal with TRV - issue #369
  • Reduced log error level for failed update form hub to warning