When Assembly name has spaces shortcuts wont work #713

@jordyvaneijk

Description

@jordyvaneijk

If I have a space in my Assembly name (I.E.: Hello World) then my applications executable will be Hello World.exe When the startmenu shortcuts are created the Taget at that time will be something like:
C:\PathToApplication\Update.exe --processStart Hello World.exe
This will give the following exception while trying to start the application from the startmenu

2016-05-26 09:24:57> Program: File C:\PathToApplication\app-1.0.0.3\Hello doesn't exist in current release
2016-05-26 09:24:57> Unhandled exception: System.ArgumentException: Value does not fall within the expected range.
at Squirrel.Update.Program.ProcessStart(String exeName, String arguments, Boolean shouldWait)
at Squirrel.Update.Program.executeCommandLine(String[] args)
at Squirrel.Update.Program.main(String[] args)

This can be fixed by putting puting qoutes around the executables name in the Target of the shortcut C:\PathToApplication\Update.exe --processStart "Hello World.exe". Maybe this can be fixed?