Skip to content

Commit cc9ebc6

Browse files
Warning added to grounding screw.
Commonly reported issue with grounding screw head shearing off. Added note with advice to pre-tap hole for 8-32. Working on permenant fix.
1 parent db9664b commit cc9ebc6

File tree

1 file changed

+2
-0
lines changed

1 file changed

+2
-0
lines changed

docs/wire-tool-v1.0/user-manual/index.md

+2
Original file line numberDiff line numberDiff line change
@@ -408,6 +408,8 @@ Requires:
408408

409409
The grounding wire is secured with a self tapping screw. This screw cuts into the endoskeleton and grounds it. This is done for safety and EMI reduction.
410410

411+
**ALERT.** Users have reported shearing of the screw head during installation. It is highly recommended to thread this hole manually with an 8-32 tap prior to installation. If unable to tap this hole, it is recommended to use a fastener with a clearly visible cutting tip with recess for chips. Rack Robotics is working on a fix.
412+
411413
Requires:
412414
- Self Tapping Screw
413415
- Ground Wire

0 commit comments

Comments
 (0)