File tree Expand file tree Collapse file tree
Expand file tree Collapse file tree Original file line number Diff line number Diff line change @@ -383,9 +383,9 @@ add_simulation_test(IDF_FILE HeatPumpWaterToAirEquationFit_WaterHeatingDesuperhe
383383add_simulation_test (IDF_FILE HeatPumpWaterToAirEquationFit.idf EPW_FILE USA_IL_Chicago-OHare.Intl.AP.725300_TMY3.epw )
384384add_simulation_test (IDF_FILE HeatPumpWaterToAirWithAntifreezeAndLatentModel.idf EPW_FILE USA_IL_Chicago-OHare.Intl.AP.725300_TMY3.epw )
385385add_simulation_test (IDF_FILE HeatPumpWaterToAirWithAntifreezeAndLatentModel2.idf EPW_FILE USA_IL_Chicago-OHare.Intl.AP.725300_TMY3.epw )
386- add_simulation_test (IDF_FILE HeatPumpWaterToAirWithRHControl.idf EPW_FILE USA_IL_Chicago-OHare .Intl.AP.725300_TMY3 .epw )
387- add_simulation_test (IDF_FILE HeatPumpWaterToAirWithRHControlDewPoint .idf EPW_FILE USA_FL_Miami.Intl.AP.722020_TMY3.epw )
388- add_simulation_test (IDF_FILE HeatPumpwithBiquadraticCurves.idf EPW_FILE USA_FL_Miami .Intl.AP.722020_TMY3 .epw )
386+ add_simulation_test (IDF_FILE HeatPumpWaterToAirWithRHControl.idf EPW_FILE USA_FL_Miami .Intl.AP.722020_TMY3 .epw )
387+ add_simulation_test (IDF_FILE HeatPumpWaterToAirWithHumControlDewPoint .idf EPW_FILE USA_FL_Miami.Intl.AP.722020_TMY3.epw )
388+ add_simulation_test (IDF_FILE HeatPumpwithBiquadraticCurves.idf EPW_FILE USA_IL_Chicago-OHare .Intl.AP.725300_TMY3 .epw )
389389add_simulation_test (IDF_FILE HeatRecoveryElectricChiller.idf EPW_FILE USA_IL_Chicago-OHare.Intl.AP.725300_TMY3.epw )
390390add_simulation_test (IDF_FILE HeatRecoveryPlantLoop.idf EPW_FILE USA_IL_Chicago-OHare.Intl.AP.725300_TMY3.epw )
391391add_simulation_test (IDF_FILE HeatRecoveryPlantLoopAuto.idf EPW_FILE USA_IL_Chicago-OHare.Intl.AP.725300_TMY3.epw )
Original file line number Diff line number Diff line change 1- ! HeatPumpWaterToAirWithRHControl .idf
1+ ! HeatPumpWaterToAirWithHumControlDewPoint .idf
22! Basic file description: 1 story building divided into 4 exterior and one interior conditioned zones and return plenum.
33!
44! Highlights: High humidity Control using Water To Air Heat Pumps with pond heat exchanger. Five water source
1515! Design Days: Miami Intl Ap Ann Htg Wind 99% Condns WS=>MCDB
1616! Miami Intl Ap Ann Clg 1% Condns DB=>MWB
1717!
18- ! Run Period (Weather File): full annual, CHICAGO_IL_USA TMY2-94846
18+ ! Run Period (Weather File): full annual, USA_FL_Miami.Intl.AP.722020_TMY3
1919!
2020! Run Control: Zone sizing with weather file run control
2121!