URI | Type |
---|---|
/redfish/v1/ |
ServiceRoot |
/redfish/v1/AccountService |
AccountService |
/redfish/v1/AccountService/Accounts |
Collection of ManagerAccount |
/redfish/v1/AccountService/Accounts/{item} |
ManagerAccount |
/redfish/v1/AccountService/DirectoryTest |
HpeDirectoryTest |
/redfish/v1/AccountService/ExternalAccountProviders/LDAP/Certificates |
Collection of Certificate |
/redfish/v1/AccountService/ExternalAccountProviders/LDAP/Certificates/{item} |
Certificate |
/redfish/v1/AccountService/Roles |
Collection of Role |
/redfish/v1/AccountService/Roles/{item} |
Role |
/redfish/v1/AccountService/UserCertificateMapping |
Collection of HpeiLOAccountCertificateMap |
/redfish/v1/AccountService/UserCertificateMapping/{item} |
HpeiLOAccountCertificateMap |
/redfish/v1/Chassis |
Collection of Chassis |
/redfish/v1/Chassis/{item} |
Chassis |
/redfish/v1/Chassis/{item}/AccHddService |
HpeServerAccHddService |
/redfish/v1/Chassis/{item}/AccHddService/Zone |
HpeServerAccHddZone |
/redfish/v1/Chassis/{item}/Devices |
Collection of HpeServerDevice |
/redfish/v1/Chassis/{item}/Devices/{item} |
HpeServerDevice |
/redfish/v1/Chassis/{item}/Drives/{interface}/{item} |
Drive |
/redfish/v1/Chassis/{item}/NetworkAdapters |
Collection of NetworkAdapter |
/redfish/v1/Chassis/{item}/NetworkAdapters/{item} |
NetworkAdapter |
/redfish/v1/Chassis/{item}/NetworkAdapters/{item}/NetworkDeviceFunctions |
Collection of NetworkDeviceFunction |
/redfish/v1/Chassis/{item}/NetworkAdapters/{item}/NetworkDeviceFunctions/{item} |
NetworkDeviceFunction |
/redfish/v1/Chassis/{item}/NetworkAdapters/{item}/NetworkDeviceFunctions/{item}/Settings |
NetworkDeviceFunction |
/redfish/v1/Chassis/{item}/NetworkAdapters/{item}/NetworkPorts |
Collection of NetworkPort |
/redfish/v1/Chassis/{item}/NetworkAdapters/{item}/NetworkPorts/{item} |
NetworkPort |
/redfish/v1/Chassis/{item}/NetworkAdapters/{item}/NetworkPorts/{item}/HpeEVB |
HpeNetworkPortEVB |
/redfish/v1/Chassis/{item}/NetworkAdapters/{item}/NetworkPorts/{item}/HpeLLDP |
HpeNetworkPortLLDP |
/redfish/v1/Chassis/{item}/NetworkAdapters/{item}/NetworkPorts/{item}/Settings |
NetworkPort |
/redfish/v1/Chassis/{item}/NetworkAdapters/{item}/Settings |
NetworkAdapter |
/redfish/v1/Chassis/{item}/Power |
Power |
/redfish/v1/Chassis/{item}/Power/AccPowerService |
HpeServerAccPowerService |
/redfish/v1/Chassis/{item}/Power/AccPowerService/Calibration |
HpeServerAccPowerCalibration |
/redfish/v1/Chassis/{item}/Power/AccPowerService/NodesInfo |
HpeServerAccPowerNodesInfo |
/redfish/v1/Chassis/{item}/Power/AccPowerService/PowerLimit |
HpeServerAccPowerLimit |
/redfish/v1/Chassis/{item}/Power/AccPowerService/Zone |
HpeServerAccPowerZone |
/redfish/v1/Chassis/{item}/Power/FastPowerMeter |
HpePowerMeter |
/redfish/v1/Chassis/{item}/Power/FederatedGroupCapping |
HpeiLOFederatedGroupCapping |
/redfish/v1/Chassis/{item}/Power/PowerMeter |
HpePowerMeter |
/redfish/v1/Chassis/{item}/Thermal |
Thermal |
/redfish/v1/EventService |
EventService |
/redfish/v1/EventService/CACertificates |
Collection of HpeCertificate |
/redfish/v1/EventService/CACertificates/{item} |
HpeCertificate |
/redfish/v1/EventService/Subscriptions |
Collection of EventDestination |
/redfish/v1/EventService/Subscriptions/{item} |
EventDestination |
/redfish/v1/JsonSchemas |
Collection of JsonSchemaFile |
/redfish/v1/JsonSchemas/{item} |
JsonSchemaFile |
/redfish/v1/Managers |
Collection of Manager |
/redfish/v1/Managers/{item} |
Manager |
/redfish/v1/Managers/{item}/ActiveHealthSystem |
HpeiLOActiveHealthSystem |
/redfish/v1/Managers/{item}/BackupRestoreService |
HpeiLOBackupRestoreService |
/redfish/v1/Managers/{item}/BackupRestoreService/BackupFiles |
Collection of HpeiLOBackupFile |
/redfish/v1/Managers/{item}/BackupRestoreService/BackupFiles/{item} |
HpeiLOBackupFile |
/redfish/v1/Managers/{item}/DateTime |
HpeiLODateTime |
/redfish/v1/Managers/{item}/EmbeddedMedia |
HpeiLOEmbeddedMedia |
/redfish/v1/Managers/{item}/EthernetInterfaces |
Collection of EthernetInterface |
/redfish/v1/Managers/{item}/EthernetInterfaces/{item} |
EthernetInterface |
/redfish/v1/Managers/{item}/FederationGroups |
Collection of HpeiLOFederationGroup |
/redfish/v1/Managers/{item}/FederationGroups/{item} |
HpeiLOFederationGroup |
/redfish/v1/Managers/{item}/FederationPeers |
Collection of HpeiLOFederationPeers |
/redfish/v1/Managers/{item}/FederationPeers/{item} |
HpeiLOFederationPeers |
/redfish/v1/Managers/{item}/HostInterfaces |
Collection of HostInterface |
/redfish/v1/Managers/{item}/HostInterfaces/{item} |
HostInterface |
/redfish/v1/Managers/{item}/LicenseService |
Collection of HpeiLOLicense |
/redfish/v1/Managers/{item}/LicenseService/{item} |
HpeiLOLicense |
/redfish/v1/Managers/{item}/LogServices |
Collection of LogService |
/redfish/v1/Managers/{item}/LogServices/IEL |
LogService |
/redfish/v1/Managers/{item}/LogServices/IEL/Entries |
Collection of LogEntry |
/redfish/v1/Managers/{item}/LogServices/IEL/Entries/{item} |
LogEntry |
/redfish/v1/Managers/{item}/NetworkProtocol |
ManagerNetworkProtocol |
/redfish/v1/Managers/{item}/RemoteSupportService |
HpeRemoteSupport |
/redfish/v1/Managers/{item}/RemoteSupportService/ServiceEventLogs |
Collection of LogEntry |
/redfish/v1/Managers/{item}/RemoteSupportService/ServiceEventLogs/{item} |
LogEntry |
/redfish/v1/Managers/{item}/SecurityService |
HpeSecurityService |
/redfish/v1/Managers/{item}/SecurityService/CertificateAuthentication |
HpeCertAuth |
/redfish/v1/Managers/{item}/SecurityService/CertificateAuthentication/CACertificates |
Collection of HpeCertificate |
/redfish/v1/Managers/{item}/SecurityService/CertificateAuthentication/CACertificates/{item} |
HpeCertificate |
/redfish/v1/Managers/{item}/SecurityService/ESKM |
HpeESKM |
/redfish/v1/Managers/{item}/SecurityService/HttpsCert |
HpeHttpsCert |
/redfish/v1/Managers/{item}/SecurityService/SSO |
HpeiLOSSO |
/redfish/v1/Managers/{item}/SecurityService/SecurityDashboard |
HpeiLOSecurityDashboard |
/redfish/v1/Managers/{item}/SecurityService/SecurityDashboard/SecurityParams |
Collection of HpeiLOSecurityParam |
/redfish/v1/Managers/{item}/SecurityService/SecurityDashboard/SecurityParams/{item} |
HpeiLOSecurityParam |
/redfish/v1/Managers/{item}/SnmpService |
HpeiLOSnmpService |
/redfish/v1/Managers/{item}/SnmpService/SNMPAlertDestinations |
Collection of HpeSNMPAlertDestination |
/redfish/v1/Managers/{item}/SnmpService/SNMPAlertDestinations/{item} |
HpeSNMPAlertDestination |
/redfish/v1/Managers/{item}/SnmpService/SNMPUsers |
Collection of HpeSNMPUser |
/redfish/v1/Managers/{item}/SnmpService/SNMPUsers/{item} |
HpeSNMPUser |
/redfish/v1/Managers/{item}/VirtualMedia |
Collection of VirtualMedia |
/redfish/v1/Managers/{item}/VirtualMedia/{item} |
VirtualMedia |
/redfish/v1/Registries |
Collection of MessageRegistryFile |
/redfish/v1/Registries/{item} |
MessageRegistryFile |
/redfish/v1/ResourceDirectory |
HpeiLOResourceDirectory |
/redfish/v1/SessionService |
SessionService |
/redfish/v1/SessionService/Sessions |
Collection of Session |
/redfish/v1/SessionService/Sessions/{item} |
Session |
/redfish/v1/Systems |
Collection of ComputerSystem |
/redfish/v1/Systems/{item} |
ComputerSystem |
/redfish/v1/Systems/{item}/BaseNetworkAdapters |
Collection of HpeBaseNetworkAdapter |
/redfish/v1/Systems/{item}/BaseNetworkAdapters/{item} |
HpeBaseNetworkAdapter |
/redfish/v1/Systems/{item}/Bios |
Bios |
/redfish/v1/Systems/{item}/Bios/Settings |
Bios |
/redfish/v1/Systems/{item}/Bios/baseconfigs |
HpeBaseConfigs |
/redfish/v1/Systems/{item}/Bios/boot |
HpeServerBootSettings |
/redfish/v1/Systems/{item}/Bios/boot/Settings |
HpeServerBootSettings |
/redfish/v1/Systems/{item}/Bios/boot/baseconfigs |
HpeBaseConfigs |
/redfish/v1/Systems/{item}/Bios/hpescalablepmem |
HpeScalablePmem |
/redfish/v1/Systems/{item}/Bios/hpescalablepmem/Settings |
HpeScalablePmem |
/redfish/v1/Systems/{item}/Bios/iscsi |
HpeiSCSISoftwareInitiator |
/redfish/v1/Systems/{item}/Bios/iscsi/Settings |
HpeiSCSISoftwareInitiator |
/redfish/v1/Systems/{item}/Bios/iscsi/baseconfigs |
HpeBaseConfigs |
/redfish/v1/Systems/{item}/Bios/mappings |
HpeBiosMapping |
/redfish/v1/Systems/{item}/Bios/tlsconfig |
HpeTlsConfig |
/redfish/v1/Systems/{item}/Bios/tlsconfig/Settings |
HpeTlsConfig |
/redfish/v1/Systems/{item}/Bios/tlsconfig/baseconfigs |
HpeBaseConfigs |
/redfish/v1/Systems/{item}/BootOptions |
Collection of BootOption |
/redfish/v1/Systems/{item}/BootOptions/{item} |
BootOption |
/redfish/v1/Systems/{item}/EthernetInterfaces |
Collection of EthernetInterface |
/redfish/v1/Systems/{item}/EthernetInterfaces/{item} |
EthernetInterface |
/redfish/v1/Systems/{item}/LogServices |
Collection of LogService |
/redfish/v1/Systems/{item}/LogServices/IML |
LogService |
/redfish/v1/Systems/{item}/LogServices/IML/Entries |
Collection of LogEntry |
/redfish/v1/Systems/{item}/LogServices/IML/Entries/{item} |
LogEntry |
/redfish/v1/Systems/{item}/Memory |
Collection of Memory |
/redfish/v1/Systems/{item}/Memory/{item} |
Memory |
/redfish/v1/Systems/{item}/MemoryDomains |
Collection of MemoryDomain |
/redfish/v1/Systems/{item}/MemoryDomains/{item} |
MemoryDomain |
/redfish/v1/Systems/{item}/MemoryDomains/{item}/MemoryChunks |
Collection of MemoryChunks |
/redfish/v1/Systems/{item}/MemoryDomains/{item}/MemoryChunks/{item} |
MemoryChunks |
/redfish/v1/Systems/{item}/NetworkInterfaces |
Collection of NetworkInterface |
/redfish/v1/Systems/{item}/NetworkInterfaces/{item} |
NetworkInterface |
/redfish/v1/Systems/{item}/NetworkInterfaces/{item}/NetworkDeviceFunctions |
Collection of NetworkDeviceFunction |
/redfish/v1/Systems/{item}/NetworkInterfaces/{item}/NetworkDeviceFunctions/{item} |
NetworkDeviceFunction |
/redfish/v1/Systems/{item}/NetworkInterfaces/{item}/NetworkPorts |
Collection of NetworkPort |
/redfish/v1/Systems/{item}/NetworkInterfaces/{item}/NetworkPorts/{item} |
NetworkPort |
/redfish/v1/Systems/{item}/NetworkInterfaces/{item}/NetworkPorts/{item}/HpeEVB |
HpeNetworkPortEVB |
/redfish/v1/Systems/{item}/NetworkInterfaces/{item}/NetworkPorts/{item}/HpeLLDP |
HpeNetworkPortLLDP |
/redfish/v1/Systems/{item}/NetworkInterfaces/{item}/NetworkPorts/{item}/Settings |
NetworkPort |
/redfish/v1/Systems/{item}/PCIDevices |
Collection of HpeServerPciDevice |
/redfish/v1/Systems/{item}/PCIDevices/{item} |
HpeServerPciDevice |
/redfish/v1/Systems/{item}/PCISlots |
Collection of HpeServerPCISlot |
/redfish/v1/Systems/{item}/PCISlots/{item} |
HpeServerPCISlot |
/redfish/v1/Systems/{item}/Processors |
Collection of Processor |
/redfish/v1/Systems/{item}/Processors/{item} |
Processor |
/redfish/v1/Systems/{item}/SecureBoot |
SecureBoot |
/redfish/v1/Systems/{item}/SmartStorage |
HpeSmartStorage |
/redfish/v1/Systems/{item}/SmartStorage/ArrayControllers |
Collection of HpeSmartStorageArrayController |
/redfish/v1/Systems/{item}/SmartStorage/ArrayControllers/{item} |
HpeSmartStorageArrayController |
/redfish/v1/Systems/{item}/SmartStorage/ArrayControllers/{item}/DiskDrives |
Collection of HpeSmartStorageDiskDrive |
/redfish/v1/Systems/{item}/SmartStorage/ArrayControllers/{item}/DiskDrives/{item} |
HpeSmartStorageDiskDrive |
/redfish/v1/Systems/{item}/SmartStorage/ArrayControllers/{item}/LogicalDrives |
Collection of HpeSmartStorageLogicalDrive |
/redfish/v1/Systems/{item}/SmartStorage/ArrayControllers/{item}/LogicalDrives/{item} |
HpeSmartStorageLogicalDrive |
/redfish/v1/Systems/{item}/SmartStorage/ArrayControllers/{item}/LogicalDrives/{item}/DataDrives |
Collection of HpeSmartStorageDiskDrive |
/redfish/v1/Systems/{item}/SmartStorage/ArrayControllers/{item}/StorageEnclosures |
Collection of HpeSmartStorageStorageEnclosure |
/redfish/v1/Systems/{item}/SmartStorage/ArrayControllers/{item}/StorageEnclosures/{item} |
HpeSmartStorageStorageEnclosure |
/redfish/v1/Systems/{item}/SmartStorage/ArrayControllers/{item}/UnconfiguredDrives |
Collection of HpeSmartStorageDiskDrive |
/redfish/v1/Systems/{item}/SmartStorage/ArrayControllers/{item}/UnconfiguredDrives/{item} |
HpeSmartStorageDiskDrive |
/redfish/v1/Systems/{item}/SmartStorage/HostBusAdapters |
Collection of HpeSmartStorageHostBusAdapter |
/redfish/v1/Systems/{item}/SmartStorage/HostBusAdapters/{item} |
HpeSmartStorageHostBusAdapter |
/redfish/v1/Systems/{item}/SmartStorage/HostBusAdapters/{item}/DiskDrives |
Collection of HpeSmartStorageDiskDrive |
/redfish/v1/Systems/{item}/SmartStorage/HostBusAdapters/{item}/DiskDrives/{item} |
HpeSmartStorageDiskDrive |
/redfish/v1/Systems/{item}/SmartStorageConfig |
SmartStorageConfig |
/redfish/v1/Systems/{item}/SmartStorageConfig/Settings |
SmartStorageConfig |
/redfish/v1/Systems/{item}/Storage |
Collection of Storage |
/redfish/v1/Systems/{item}/Storage/{interface}/{item} |
Storage |
/redfish/v1/Systems/{item}/Storage/{interface}/{item}/Volumes |
Collection of Volume |
/redfish/v1/Systems/{item}/Storage/{interface}/{item}/Volumes/{item} |
Volume |
/redfish/v1/Systems/{item}/USBDevices |
Collection of HpeUSBDevice |
/redfish/v1/Systems/{item}/USBDevices/{item} |
HpeUSBDevice |
/redfish/v1/Systems/{item}/USBPorts |
Collection of HpeUSBPort |
/redfish/v1/Systems/{item}/USBPorts/{item} |
HpeUSBPort |
/redfish/v1/Systems/{item}/WorkloadPerformanceAdvisor |
Collection of v1_0_0 |
/redfish/v1/Systems/{item}/WorkloadPerformanceAdvisor/{item} |
HpeWorkloadPerformanceAdvisor |
/redfish/v1/TaskService |
TaskService |
/redfish/v1/TaskService/Tasks |
Collection of Task |
/redfish/v1/TaskService/Tasks/{item} |
Task |
/redfish/v1/TelemetryService |
TelemetryService |
/redfish/v1/TelemetryService/MetricDefinitions |
Collection of MetricDefinition |
/redfish/v1/TelemetryService/MetricDefinitions/{item} |
MetricDefinition |
/redfish/v1/TelemetryService/MetricReportDefinitions |
Collection of MetricReportDefinition |
/redfish/v1/TelemetryService/MetricReportDefinitions/{item} |
MetricReportDefinition |
/redfish/v1/TelemetryService/MetricReports/{item} |
MetricReport |
/redfish/v1/TelemetryService/MetricsReport |
Collection of MetricReport |
/redfish/v1/TelemetryService/Triggers |
Collection of Trigger |
/redfish/v1/TelemetryService/Triggers/{item} |
Triggers |
/redfish/v1/UpdateService |
UpdateService |
/redfish/v1/UpdateService/ComponentRepository |
Collection of HpeComponent |
/redfish/v1/UpdateService/ComponentRepository/{item} |
HpeComponent |
/redfish/v1/UpdateService/FirmwareInventory |
Collection of SoftwareInventory |
/redfish/v1/UpdateService/FirmwareInventory/{item} |
SoftwareInventory |
/redfish/v1/UpdateService/InstallSets |
Collection of HpeComponentInstallSet |
/redfish/v1/UpdateService/InstallSets/{item} |
HpeComponentInstallSet |
/redfish/v1/UpdateService/InvalidImageRepository |
Collection of HpeInvalidImage |
/redfish/v1/UpdateService/InvalidImageRepository/{item} |
HpeInvalidImage |
/redfish/v1/UpdateService/MaintenanceWindows |
Collection of HpeMaintenanceWindow |
/redfish/v1/UpdateService/MaintenanceWindows/{item} |
HpeMaintenanceWindow |
/redfish/v1/UpdateService/SoftwareInventory |
Collection of SoftwareInventory |
/redfish/v1/UpdateService/SoftwareInventory/{item} |
SoftwareInventory |
/redfish/v1/UpdateService/UpdateTaskQueue |
Collection of HpeComponentUpdateTask |
/redfish/v1/UpdateService/UpdateTaskQueue/{item} |
HpeComponentUpdateTask |
@odata.type: "#AccountService.v1_3_0.AccountService"
The AccountService resource describes the BMC user account management service. It represents the properties for this service and has links to the list of accounts.
JSONPath: /Accounts/@odata.id
The destination of this link is a collection of user accounts (see ManagerAccount).
- You may create a new user account by POSTing a new account description the the Accounts collection. See ManagerAccount for details.
e.g.
POST https://{iLO}/redfish/v1/accountservice/accounts/ with new account description
- You may modify an existing user by PATCHing properties to the user account resource. See ManagerAccount for details.
e.g.
PATCH https://{iLO}/redfish/v1/accountservice/accounts/{item} with different properties
- You may remove a user account by DELETEing the resources representing the user
e.g.
DELETE https://{iLO}/redfish/v1/accountservice/accounts/{item}
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice |
GET PATCH |
Link Name | Destination type |
---|---|
Accounts |
Collection of ManagerAccount |
Member of AccountService.v1_3_0.AccountService
Description | The interval of time in seconds between the last failed login attempt and reset of the lockout threshold counter. This value must be less than or equal to AccountLockoutDuration. Reset sets the counter to zero. |
Type | number |
Read Only | True |
Added | iLO 5 1.40 |
Member of AccountService.v1_3_0.AccountService
Description | The time in seconds an account is locked out. The value must be greater than or equal to the value of the AccountLockoutCounterResetAfter property. If set to 0, no lockout occurs. |
Type | number or null |
Read Only | False |
Added | iLO 5 1.40 |
Member of AccountService.v1_3_0.AccountService
Description | The number of failed login attempts allowed before a user account is locked for a specified duration. A value of 0 means it is never locked. |
Type | number or null |
Read Only | False |
Added | iLO 5 1.40 |
This property references a resource of type Collection with a MemberType of ManagerAccount.
Accounts is a link ("@odata.id": URI
) to another resource.
ActiveDirectory.AccountProviderType Member of AccountService.v1_3_0.AccountService
Description | This property contains the type of external account provider this resource references. |
Type | string |
Read Only | False |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
ActiveDirectoryService |
An external Active Directory Service. |
ActiveDirectory.Authentication ActiveDirectory.Authentication.AuthenticationType Member of AccountService.v1_3_0.AccountService
Description | This property contains the type of authentication used to connect to the external account provider. |
Type | string |
Read Only | False |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
UsernameAndPassword |
Username and password combination. |
ActiveDirectory.Authentication.Password Member of AccountService.v1_3_0.AccountService
Description | This property is used with a PATCH or PUT to write the password for the account service. This property is null on a GET. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.40 |
ActiveDirectory.Authentication.Username Member of AccountService.v1_3_0.AccountService
Description | This property contains the distinguished name for the account service. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.40 |
ActiveDirectory.RemoteRoleMapping (array)
Member of AccountService.v1_3_0.AccountService
RemoteRoleMapping
is an array containing elements of:
RemoteRoleMapping[{item}].LocalRole Member of AccountService.v1_3_0.AccountService
Description | The name of the local role in which to map the remote user or group. |
Type | string or null |
Read Only | False |
RemoteRoleMapping[{item}].RemoteGroup Member of AccountService.v1_3_0.AccountService
Description | This property is the name of the remote group (or in the case of a Redfish Service, remote role) that will be mapped to the local role referenced by this entity. |
Type | string or null |
Read Only | False |
ActiveDirectory.ServiceAddresses (array)
Member of AccountService.v1_3_0.AccountService
ServiceAddresses
is an array containing elements of:
Type | string or null |
Read Only | True |
ActiveDirectory.ServiceEnabled Member of AccountService.v1_3_0.AccountService
Description | This indicates whether this service is enabled. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.40 |
Member of AccountService.v1_3_0.AccountService
Description | The number of authorization failures allowed before the failure attempt is logged to the manager log. |
Type | number |
Read Only | False |
LDAP.AccountProviderType Member of AccountService.v1_3_0.AccountService
Description | This property contains the type of external account provider this resource references. |
Type | string |
Read Only | False |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
ActiveDirectoryService |
An external Active Directory Service. |
LDAPService |
A generic external LDAP Service. |
LDAP.Authentication LDAP.Authentication.AuthenticationType Member of AccountService.v1_3_0.AccountService
Description | This property contains the type of authentication used to connect to the external account provider. |
Type | string |
Read Only | False |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
UsernameAndPassword |
Username and password combination. |
LDAP.Authentication.Password Member of AccountService.v1_3_0.AccountService
Description | This property is used with a PATCH or PUT to write the password for the account service. This property is null on a GET. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.40 |
LDAP.Authentication.Username Member of AccountService.v1_3_0.AccountService
Description | This property contains the distinguished name for the account service. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.40 |
LDAP.LDAPService
LDAP.LDAPService.SearchSettings
LDAP.LDAPService.SearchSettings.BaseDistinguishedNames (array)
Member of AccountService.v1_3_0.AccountService
BaseDistinguishedNames
is an array containing elements of:
Type | string or null |
Read Only | True |
LDAP.RemoteRoleMapping (array)
Member of AccountService.v1_3_0.AccountService
RemoteRoleMapping
is an array containing elements of:
RemoteRoleMapping[{item}].LocalRole Member of AccountService.v1_3_0.AccountService
Description | The name of the local role in which to map the remote user or group. |
Type | string or null |
Read Only | False |
RemoteRoleMapping[{item}].RemoteGroup Member of AccountService.v1_3_0.AccountService
Description | This property is the name of the remote group (or in the case of a Redfish Service, remote role) that will be mapped to the local role referenced by this entity. |
Type | string or null |
Read Only | False |
LDAP.ServiceAddresses (array)
Member of AccountService.v1_3_0.AccountService
ServiceAddresses
is an array containing elements of:
Type | string or null |
Read Only | True |
LDAP.ServiceEnabled Member of AccountService.v1_3_0.AccountService
Description | This indicates whether this service is enabled. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.40 |
Member of AccountService.v1_3_0.AccountService
Description | Controls when this service will use the accounts defined withing this AccountService as part of authentication. |
Type | string |
Read Only | False |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
Authentication via accounts defined in this AccountService is enabled. |
Disabled |
Authentication via accounts defined in this AccountService is disabled. |
Member of AccountService.v1_3_0.AccountService
Description | The maximum password length for this service. |
Type | number |
Read Only | True |
Added | iLO 5 1.40 |
Member of AccountService.v1_3_0.AccountService
Description | The minimum password length for this service. |
Type | number |
Read Only | True |
Added | iLO 5 1.40 |
Member of AccountService.v1_3_0.AccountService
Description | The time in seconds to delay for each failure after AuthFailuresBeforeDelay authentication attempts have failed. Values of 2, 5, 10, and 30 seconds are valid. |
Type | integer |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
2 |
5 |
10 |
30 |
Member of AccountService.v1_3_0.AccountService
Description | This property enables you to view and configure logging criteria for failed authentications. A failed login log entry is recorded after the configured number of attempts. 0 = feature disabled; 1-3 and 5 are allowable values. |
Type | integer |
Read Only | False |
The following are the supported values:
Value |
---|
Null |
1 |
2 |
3 |
5 |
Member of AccountService.v1_3_0.AccountService
Description | The number of failed authentication attempts allowed before authentication is delayed by AuthFailureDelayTimeSeconds. Values of 0, 1, 3, and 5 are valid, with 0 indicating delay after every authentication failure. |
Type | integer |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Null |
1 |
3 |
5 |
Member of AccountService.v1_3_0.AccountService
Description | The default password used to log in to the management processor when factory reset is performed. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.17 |
Member of AccountService.v1_3_0.AccountService
Description | The default name used to log in to the management processor when factory reset is performed. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.17 |
Oem.Hpe.DirectorySettings.LdapAuthenticationMode Member of AccountService.v1_3_0.AccountService
Description | Represents the LDAP authentication mode. |
Type | string |
Read Only | False |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Disabled |
Directory authentication is disabled. |
DefaultSchema |
Directory Default schema or Schema-free option is selected. |
ExtendedSchema |
HPE Extended schema is selected. |
Oem.Hpe.DirectorySettings.LdapCaCertificateLoaded Member of AccountService.v1_3_0.AccountService
Description | Represents if the directory server CA certificate is loaded or not. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.40 |
Oem.Hpe.DirectorySettings.LdapCaCertificates
A link to a collection of Certificates.
LdapCaCertificates is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.DirectorySettings.LdapServerPort Member of AccountService.v1_3_0.AccountService
Description | Represents the port number of the directory server. |
Type | integer |
Read Only | True |
Added | iLO 5 1.40 |
The value of this property shall be a reference to a resource of type HpeDirectoryTest.
DirectoryTest is a link ("@odata.id": URI
) to another resource.
Member of AccountService.v1_3_0.AccountService
Description | Enforce complexity rules when a user password is set or changed. Three of four character classes must be present; ASCII UPPERCASE, LOWERCASE, DIGITS, and Other |
Type | boolean |
Read Only | False |
Added | iLO 5 1.40 |
Oem.Hpe.KerberosSettings.KDCServerPort Member of AccountService.v1_3_0.AccountService
Description | Represents the port number of the KDC server. |
Type | integer |
Read Only | True |
Added | iLO 5 1.40 |
Oem.Hpe.KerberosSettings.KerberosRealm Member of AccountService.v1_3_0.AccountService
Description | Represents the Realm of the KDC server. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.40 |
Member of AccountService.v1_3_0.AccountService
Description | This property specifies the minimum number of characters allowed when a user password is set or changed. It must be a value from 0 to 39. |
Type | integer |
Read Only | False |
Added | iLO 5 1.10 |
A link to a collection of Roles.
Roles is a link ("@odata.id": URI
) to another resource.
HpeiLOAccountService.ImportKerberosKeytab Member of AccountService.v1_3_0.AccountService Import the Kerberos keytab file.
Parameters:
ImportUri (string)
URI of the kerberos keytab file.
@odata.type: "#Bios.v1_0_0.Bios"
Bios contains properties surrounding a BIOS Attribute Registry (where the system-specific BIOS attributes are described) and the Actions needed to perform changes to BIOS settings, which typically require a system reset to apply.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/bios |
GET |
/redfish/v1/systems/{item}/bios/settings |
GET POST PATCH |
Link Name | Destination type |
---|---|
Oem/Hpe/Links/Boot |
HpeServerBootSettings |
Oem/Hpe/Links/ScalablePmem |
HpeScalablePmem |
@Redfish.Settings/SettingsObject |
Bios |
Oem/Hpe/Links/TlsConfig |
HpeTlsConfig |
Oem/Hpe/Links/BaseConfigs |
HpeBaseConfigs |
Oem/Hpe/Links/Mappings |
HpeBiosMapping |
Oem/Hpe/Links/iScsi |
HpeiSCSISoftwareInitiator |
Member of Bios.v1_0_0.Bios See the Redfish standard schema and specification for information on common @Redfish properties.
Member of Bios.v1_0_0.Bios
Description | The Resource ID of the Attribute Registry for the BIOS Attributes resource. |
Type | string or null |
Read Only | True |
AcpiHpet (High Precision Event Timer (HPET) ACPI Support) Member of Bios.v1_0_0.Bios
Description | Use this option to disable the High Precision Event Timer (HPET) table and device object in ACPI. When disabled, the HPET is not available to an operating system that supports the HPET through the industry standard ACPI name space. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
AcpiRootBridgePxm (Memory Proximity Reporting for I/O) Member of Bios.v1_0_0.Bios
Description | When enabled, the System BIOS reports the proximity relationship between I/O devices and system memory to the operating system. Most operating systems can use this information to efficiently assign memory resources for devices, such as network controllers and storage devices. Additionally, certain I/O devices might not be able to take advantage of I/O handling benefits if their OS drivers are not properly optimized to support this feature. See your operating system and I/O device documentation for more details. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
AcpiSlit (ACPI SLIT) Member of Bios.v1_0_0.Bios
Description | The ACPI SLIT (System Locality Information Table) defines the relative access times between processors, memory subsystems, and I/O subsystems. Operating systems that support the SLIT can use this information to improve performance by allocating resources and workloads more efficiently. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
AdjSecPrefetch (Adjacent Sector Prefetch) Member of Bios.v1_0_0.Bios
Description | Use this option to disable the processor Adjacent Sector Prefetch feature. In some cases, setting this option to disabled can improve performance. Typically, setting this option to enabled provides better performance. Only disable this option after performing application benchmarking to verify improved performance in the environment. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
AdminEmail (Administrator E-mail Address) Member of Bios.v1_0_0.Bios
Description | Enter the server administrator's e-mail address. |
Type | String |
Read Only | False |
AdminName (Administrator Name) Member of Bios.v1_0_0.Bios
Description | Enter the server administrator's name text. |
Type | String |
Read Only | False |
AdminOtherInfo (Administrator Other Information) Member of Bios.v1_0_0.Bios
Description | Enter the server administrator's information text. |
Type | String |
Read Only | False |
AdminPhone (Administrator Phone Number) Member of Bios.v1_0_0.Bios
Description | Enter the server administrator's phone number text. |
Type | String |
Read Only | False |
AdvCrashDumpMode (Advanced Crash Dump Mode) Member of Bios.v1_0_0.Bios
Description | Use this option to enable the Advanced Crash Dump Mode. When enabled, the system will be configured to log additional debug information to the Active Health System logs when an unexpected system crash is experienced. This option should only be enabled when directed by qualified service personnel |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Enabled |
Enabled |
AdvancedMemProtection (Advanced Memory Protection) Member of Bios.v1_0_0.Bios
Description | Use this option to configure additional memory protection with ECC (Error Checking and Correcting). Options and support vary per system. |
Advanced ECC keeps all installed memory available for use while still protecting the system against all single-bit failures and certain multi-bit failures. | |
Online Spare Memory enables a system to automatically map out a group of memory that is detected to be at an increased risk of receiving uncorrected memory errors based on an advanced analysis of corrected memory errors. The mapped out memory is automatically replaced by a spare group of memory without interrupting the system. | |
Mirrored Memory provides the maximum protection against uncorrected memory errors that might otherwise result in a system failure. | |
Fault Tolerant Advanced Double Device Data Correction (ADDDC) enables the system to correct memory errors and continue to operate in cases of multiple DRAM device failures on a DIMM. This provides protection against uncorrectable memory errors beyond what is available with Advanced ECC. | |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
FastFaultTolerantADDDC |
Fault Tolerant Memory (ADDDC) |
AdvancedEcc |
Advanced ECC Support |
OnlineSpareAdvancedEcc |
Online Spare with Advanced ECC Support |
MirroredAdvancedEcc |
Mirrored Memory with Advanced ECC Support |
AsrStatus (ASR Status) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the Automatic Server Recovery option, which enables the system to automatically reboot if the server locks up. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
AsrTimeoutMinutes (ASR Timeout) Member of Bios.v1_0_0.Bios
Description | When Automatic Server Recovery is enabled, you can use this option to set the time to wait before rebooting the server in the event of an operating system crash or server lockup. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Timeout10 |
10 Minutes |
Timeout15 |
15 Minutes |
Timeout20 |
20 Minutes |
Timeout30 |
30 Minutes |
Timeout5 |
5 Minutes |
AssetTagProtection (Asset Tag Protection) Member of Bios.v1_0_0.Bios
Description | Use this option to lock Asset Tag information. When set to lock, the Asset Tag is not erased if the default system settings are restored. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Locked |
Locked |
Unlocked |
Unlocked |
AutoPowerOn (Automatic Power-On) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the server power state when AC power is applied to the system. |
Restore Last Power State returns the system to its previous power state when AC power is restored after an AC power loss. | |
Note: This option is not available on all systems. | |
Always Power On and Always Power Off causes the system to always return to the "on" and "off" state, respectively, whenever power is applied, even if the system is in the "off" state when power is lost. | |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AlwaysPowerOn |
Always Power On |
AlwaysPowerOff |
Always Power Off |
RestoreLastState |
Restore Last Power State |
BootMode (Boot Mode) Member of Bios.v1_0_0.Bios
Description | Use this option to select the boot mode of the system. Selecting UEFI Mode configures the system to boot Unified Extensible Firmware Interface (UEFI) compatible operating systems. Selecting Legacy BIOS Mode configures the system to boot traditional operating systems in Legacy BIOS compatibility mode. The operating system can only boot in the mode in which it is installed. The following options require booting in UEFI Mode: Secure Boot, IPv6 PXE Boot, boot > 2.2 TB Disks in AHCI SATA Mode, and Smart Array SW RAID. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Uefi |
UEFI Mode |
LegacyBios |
Legacy BIOS Mode |
BootOrderPolicy (Boot Order Policy) Member of Bios.v1_0_0.Bios
Description | Use this option to configure how the system attempts to boot devices per the Boot Order list when no bootable device is found. If configured to 'Retry Boot Order Indefinitely,' the system continuously attempts to process the Boot Order list until a bootable device is found. If configured to 'Attempt Boot Order Once,' the system attempts to process all items in the Boot Order list once, and if unsuccessful, waits for user input to proceed. If configured for 'Reset After Failed Boot Attempt,' the system attempts to process all items in the Boot Order list once, and then reboots the system. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
RetryIndefinitely |
Retry Boot Order Indefinitely |
AttemptOnce |
Attempt Boot Order Once |
ResetAfterFailed |
Reset After Failed Boot Attempt |
ChannelInterleaving (Channel Interleaving) Member of Bios.v1_0_0.Bios
Description | You can only configure this option if the Workload Profile is set to Custom. Use this option to modify the level of interleaving for which the memory system is configured. Typically, higher levels of memory interleaving result in maximum performance. However, reducing the level of interleaving can result in power savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
CollabPowerControl (Collaborative Power Control) Member of Bios.v1_0_0.Bios
Description | For operating systems that support the Processor Clocking Control (PCC) Interface, enabling this option enables the Operating System to request processor frequency changes even if the Power Regulator option on the server are configured for Dynamic Power Savings Mode. For Operating Systems that do not support the PCC Interface, or when the Power Regulator Mode is not configured for Dynamic Power Savings Mode, this option has no effect on system operation. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
ConsistentDevNaming (Consistent Device Naming) Member of Bios.v1_0_0.Bios
Description | Use this option to select the level of Consistent Device Naming. On supported operating systems, NIC ports are named based on their location in the system. CDN Support for LOMs Only names Embedded NICs and FlexibleLOMs. Existing NIC connections retain their names until reinstalled under the OS environment. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
LomsAndSlots |
CDN Support for LOMs and Slots |
LomsOnly |
CDN Support for LOMs Only |
Disabled |
Disabled |
CoreBoosting (Core Boosting) Member of Bios.v1_0_0.Bios
Description | Use this option to enable the Core Boosting technology to increase processor performance on qualified processors. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Enabled |
Enabled |
CustomPostMessage (Custom POST Message) Member of Bios.v1_0_0.Bios
Description | Enter a message to be displayed on POST screen during system startup. This feature limits POST screen messaging to 62 characters, special characters are also accepted. |
Type | String |
Read Only | False |
DaylightSavingsTime (Daylight Savings Time) Member of Bios.v1_0_0.Bios
Description | This option controls the Daylight Savings Time (DST) adjustment to the displayed local time. If this option is disabled, the displayed local time will not be adjusted for DST. If this option is enabled, the displayed local time will be advanced by one hour. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Enabled |
Enabled |
DcuIpPrefetcher (DCU IP Prefetcher) Member of Bios.v1_0_0.Bios
Description | Use this option to disable the processor DCU IP Prefetcher feature. In some cases, setting this option to disabled can improve performance. In most cases, the default value of enabled provides optimal performance. Only disable this option after performing application benchmarking to verify improved performance in the environment. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
DcuStreamPrefetcher (DCU Stream Prefetcher) Member of Bios.v1_0_0.Bios
Description | Use this option to disable the processor DCU Stream Prefetcher feature. In some cases, setting this option to disabled can improve performance. Typically, setting this option to enabled provides better performance. Only disable this option after performing application benchmarking to verify improved performance in your environment. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Dhcpv4 (DHCPv4) Member of Bios.v1_0_0.Bios
Description | When enabled, this option enables obtaining the pre-boot network IPv4 configuration from a DHCP server. Individual settings are not available. When disabled, you must configure static IP address settings individually. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
DirectToUpi (Direct To UPI (D2K)) Member of Bios.v1_0_0.Bios
Description | Direct To UPI (D2K) |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Enabled |
Enabled |
Disabled |
Disabled |
DynamicPowerCapping (Dynamic Power Capping Functionality) Member of Bios.v1_0_0.Bios
Description | Use this option to configure when the System BIOS executes power calibration during the boot process. In Auto mode, calibration is run the first time the server is booted, and is then only run again when the server's hardware configuration changes, configuration settings change, or if the system determines a new calibration is necessary. When disabled, the calibration does not run, and Dynamic Power Capping is not supported. When enabled, the calibration is run on every boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Enabled |
Enabled |
Disabled |
Disabled |
EmbNicAspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device's link enters a standby energy savings state. When configured for L1 Enabled, the selected device's link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device's link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
EmbNicEnable (PCIe Device Disable) Member of Bios.v1_0_0.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
EmbNicLinkSpeed (PCIe Link Speed) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
EmbNicPCIeOptionROM (PCIe Option ROM) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
EmbSas1Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device's link enters a standby energy savings state. When configured for L1 Enabled, the selected device's link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device's link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
EmbSas1Boot (Embedded SAS Controller 1) Member of Bios.v1_0_0.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order list.If Boot Limit to 24 Targets is selected, 24 boot targets attached to the storage controller are made available in the UEFI Boot Order list. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
TwentyFourTargets |
Boot Limit to 24 Targets |
NoTargets |
Boot No Targets |
EmbSas1Enable (PCIe Device Disable) Member of Bios.v1_0_0.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
EmbSas1LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
EmbSas1PcieOptionROM (PCIe Option ROM) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
EmbSata1Aspm (SATA Power Management(SALP)) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable Aggressive Link Power Management(SALP). |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Enabled |
Enabled |
EmbSata1Enable (SATA Device Disable) Member of Bios.v1_0_0.Bios
Description | Select this option to enable or disable SATA devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
EmbSata1PCIeOptionROM (PCIe Option ROM) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
EmbSata2Aspm (SATA Power Management(SALP)) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable Aggressive Link Power Management(SALP). |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Enabled |
Enabled |
EmbSata2Enable (SATA Device Disable) Member of Bios.v1_0_0.Bios
Description | Select this option to enable or disable SATA devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
EmbSata2PCIeOptionROM (PCIe Option ROM) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
EmbVideoConnection (Embedded Video Connection) Member of Bios.v1_0_0.Bios
Description | When configured for Auto mode, the external video connection to the embedded video controller is automatically disabled to save power when a monitor is not attached. It is automatically enabled when a monitor is attached, including when the server is operating. When configured for Always Disabled, the external video connection to the embedded video controller is disabled, and a monitor connected to this port does not display except during system boot. This can be used for security reasons. When configured for Always Enabled, the external video connection to the embedded video controller is always enabled. This option is only required if a monitor is attached with a monitor detection that does not function properly (making AUTO mode not work properly). Note: This option does not affect Integrated Remote Console video. Also, if you press F9 or F11 during system boot, the configured video connector behavior is overridden, and the video console remains enabled. This lets you reconfigure the Embedded Video Connection option even if the video is disabled. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
AlwaysDisabled |
Always Disabled |
AlwaysEnabled |
Always Enabled |
EmbeddedDiagnostics (Embedded Diagnostics) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable Embedded Diagnostics functionality. If disabled, you cannot launch Embedded Diagnostics. Enable this option to use the Embedded Diagnostics functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
EmbeddedSata (Embedded SATA Configuration) Member of Bios.v1_0_0.Bios
Description | Important: Smart Array SW RAID is not supported when Boot Mode is set to Legacy BIOS Mode. |
Use this option to configure the embedded chipset SATA controller. When selecting the Advanced Host Controller Interface (AHCI) or RAID (if supported), make sure the proper operating system drivers are used for proper operation.| |Type|Enumeration| |Read Only|False|
Value | Description |
---|---|
Ahci |
SATA AHCI Support |
Raid |
Smart Array SW RAID Support |
EmbeddedSerialPort (Embedded Serial Port) Member of Bios.v1_0_0.Bios
Description | Select this option to assign the logical COM port address and associated default resources to the selected physical serial port. The operating system can overwrite this setting. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Com1Irq4 |
COM 1; IRQ4; I/O: 3F8h-3FFh |
Com2Irq3 |
COM 2; IRQ3; I/O: 2F8h-2FFh |
Disabled |
Disabled |
EmbeddedUefiShell (Embedded UEFI Shell) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable the Embedded UEFI Shell. When enabled, you can launch the Embedded UEFI Shell from the pre-boot environment. When enabled and the Boot Mode is configured for UEFI Mode, you can add the Embedded UEFI Shell to the UEFI Boot Order list by selecting the option entitled 'Add Embedded UEFI Shell to Boot Order'. When disabled, the Embedded UEFI Shell is not available in the pre-boot environment, and you cannot add it to the UEFI Boot Order list. The Embedded UEFI Shell is a pre-boot command line environment that you can use for scripting and running UEFI applications. It provides CLI-based commands to configure the server, update the System BIOS and other firmware, and obtain system information and error logs. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
EmsConsole (EMS Console) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the ACPI serial port settings, which include the ability to redirect the Windows Server Emergency Management console (EMS) through either the physical or virtual serial port. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Physical |
Physical Serial Port |
Virtual |
Virtual Serial Port |
EnabledCoresPerProc (Enabled Cores per Processor) Member of Bios.v1_0_0.Bios
Description | This option enables limiting the number of enabled processor cores per physical processor. You can set the number of enabled cores to a value supported by the physical processor. Setting the value to 0 or a value larger than the number of supported cores of the installed processor will result in all processor cores in the socket being enabled. |
Type | Integer |
Read Only | False |
EnergyEfficientTurbo (Energy Efficient Turbo) Member of Bios.v1_0_0.Bios
Description | This option controls whether the processor uses an energy efficiency based policy when engaging turbo range frequencies. This option is only applicable when Turbo Mode is enabled. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
EnergyPerfBias (Energy/Performance Bias) Member of Bios.v1_0_0.Bios
Description | You can only configure this option if the Workload Profile is set to Custom. Use this option to configure several processor subsystems to optimize the performance and power usage of the processor. Balanced Performance provides optimum power efficiency, and is recommended for most environments. Maximum Performance Mode is recommended for environments that require the highest performance and lowest latency but are not sensitive to power consumption. Only use Power Savings Mode in environments that are power sensitive and can accept reduced performance. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
MaxPerf |
Maximum Performance |
BalancedPerf |
Balanced Performance |
BalancedPower |
Balanced Power |
PowerSavingsMode |
Power Savings Mode |
EnhancedProcPerf (Enhanced Processor Performance) Member of Bios.v1_0_0.Bios
Description | Use this option to enable the Enhanced Processor Performance setting. When enabled, this option will adjust the processor settings to a more aggressive setting that can result in improved performance, but may result in a higher power consumption. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Enabled |
Enabled |
EraseUserDefaults (Erase User Defaults) Member of Bios.v1_0_0.Bios
Description | Select this option to erase the user defaults backup. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
No |
No, Cancel |
Yes |
Yes, erase the current settings. |
ExtendedAmbientTemp (Extended Ambient Temperature Support) Member of Bios.v1_0_0.Bios
Description | Use this option to enable the server to operate at higher ambient temperatures than normally supported. These options are only supported with specific hardware configurations. See your server documentation before configuring the server to enable extended ambient temperature support. Improper system operation or damage to hardware components can result from enabling these options in unsupported configurations. Selecting Enabled for 40c Ambient (ASHRAE 3) enables the server to operate in environments with ambient temperatures up to 40 degrees Celsius. Selecting Enabled for 45c Ambient (ASHRAE 4) enables the server to operate in environments with ambient temperatures up to 45 degrees Celsius. Not all servers support both 40c Ambient (ASHRAE 3) and 45c Ambient (ASHRAE 4). |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
ASHRAE3 |
Enabled for 40c Ambient (ASHRAE 3) |
ASHRAE4 |
Enabled for 45c Ambient (ASHRAE 4) |
ExtendedMemTest (Extended Memory Test) Member of Bios.v1_0_0.Bios
Description | When enabled, the system validates memory during the memory initialization process. If uncorrectable memory errors are detected, the memory is mapped out, and the failed DIMMs are logged to the Integrated Management Log (IML). Enabling this option can result in a significant increase in the server boot time. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
F11BootMenu (One-Time Boot Menu (F11 Prompt)) Member of Bios.v1_0_0.Bios
Description | Use this option to disable the POST One-Time Boot F11 Prompt. |
Note: When disabled, shell 'boot' command is not available for use. | |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
FCScanPolicy (Fibre Channel/FCoE Scan Policy) Member of Bios.v1_0_0.Bios
Description | Use this option to change the default Fibre Channel or FCoE policy for scanning for boot targets. When configured for Scan All Targets, each installed FC/FCoE adapter scans all available targets. When configured for Scan Configured Targets Only, the FC/FCoE adapters only scan targets that are preconfigured in the devices settings. This option overrides any individual device settings configured in the device-specific setup.This option is only supported in UEFI Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Scan All Targets |
CardConfig |
Scan Configured Targets Only |
FanFailPolicy (Fan Failure Policy) Member of Bios.v1_0_0.Bios
Description | Use this option to configure how the server reacts when fans fail, resulting in the server not having required fans in operation. When configured for "Shutdown/Halt on Critical Fan Failures," the server cannot boot or operate when it does not have required fans operating due to one or more fan failures. When configured for "Allow Operation with Critical Fan Failures," the server can boot and operate if it does not have required fans operating due to one or more fan failures. It is recommended that you configure the Fan Failure Policy to the default state of "Shutdown/Halt on Critical Fan Failures." Operating without the required fans operating can result in damage to hardware components. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Shutdown |
Shutdown/Halt on Critical Fan Failures |
Allow |
Allow Operation with Critical Fan Failures |
FanInstallReq (Fan Installation Requirements) Member of Bios.v1_0_0.Bios
Description | Use this option to configure how the server reacts when all required fans are not installed. When configured for Enable Messaging, the server displays messages and log events to the Integrated Management Log (IML) when required fans are not installed. The server can still boot and operate. When configured for Disable Messaging, the server does not display messages and log events when required fans are not installed. All indications that the server is operating without required fans are removed. It is recommended that you leave Fan Installation Requirements in the default state of Enable Messaging. Operating without the required fans can result in damage to hardware components. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
EnableMessaging |
Enable Messaging |
DisableMessaging |
Disable Messaging |
FlexLom1Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device's link enters a standby energy savings state. When configured for L1 Enabled, the selected device's link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device's link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
FlexLom1Enable (PCIe Device Disable) Member of Bios.v1_0_0.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
FlexLom1LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
FlexLom1PCIeOptionROM (PCIe Option ROM) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
HttpSupport (HTTP Support) Member of Bios.v1_0_0.Bios
Description | Use this option to control the UEFI HTTP(s) boot support when in UEFI Mode, and the 'Discover Shell Auto-Start Script using DHCP' option under 'Embedded UEFI Shell' settings. |
When 'Auto' is selected, the system automatically adds HTTP(S) boot options to the UEFI Boot Order list for every network port that is enabled for Network Boot. Selecting this option enables the system to boot to the HTTP or HTTPS URLs provided by the DHCP server. Any other URLs provided by the DHCP server are ignored. | |
When 'HTTP only' is selected, the system automatically adds HTTP boot options to the UEFI Boot Order list for every network port that is enabled for Network Boot. Selecting this option enables the system to boot to the HTTP URLs provided by the DHCP server, and to ignore any HTTPS or other URLs that are provided. | |
When 'HTTPS only' is selected, the system automatically adds HTTPS boot options to the UEFI Boot Order list for every network port that is enabled for Network Boot. Selecting this option enables the system to boot to the HTTPS URLs provided by the DHCP server, and to ignore any HTTP or other URLs that are provided. | |
To enable HTTPS boot either by selecting 'Auto' or 'HTTPS only', you must enroll the respective TLS certificate of the HTTPS server under Server Security > TLS(HTTPS) Options. | |
Note: This setting only affects the HTTP boot options added for the network ports, and the Discover Shell Auto-Start Script provided by the DHCP server. Other settings, such as Boot from URL, are not affected by this setting. | |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
HttpsOnly |
HTTPS only |
HttpOnly |
HTTP only |
Disabled |
Disabled |
HwPrefetcher (HW Prefetcher) Member of Bios.v1_0_0.Bios
Description | Use this option to disable the processor HW prefetch feature. In some cases, setting this option to disabled can improve performance. Typically, setting this option to enabled provides better performance. Only disable this option after performing application benchmarking to verify improved performance in the environment. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
IntelDmiLinkFreq (Intel DMI Link Frequency) Member of Bios.v1_0_0.Bios
Description | Use this option to force the link speed between the processor and the southbridge to run at slower speeds to save power. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
DmiGen1 |
Gen 1 Speed |
DmiGen2 |
Gen 2 Speed |
IntelNicDmaChannels (Intel NIC DMA Channels (IOAT)) Member of Bios.v1_0_0.Bios
Description | Use this option to select the Intel NIC DMA Channels support. This is a NIC acceleration option that only runs on Intel-based NICs. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
IntelPerfMonitoring (Intel Performance Monitoring Support) Member of Bios.v1_0_0.Bios
Description | This option does not impact performance. When enabled, this option exposes certain chipset devices that can be used with the Intel Performance Monitoring Toolkit. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Enabled |
Enabled |
IntelProcVtd (Intel(R) VT-d) Member of Bios.v1_0_0.Bios
Description | If enabled, a hypervisor or operating system supporting this option can use hardware capabilities provided by Intel VT for Directed I/O. You can leave this set to enabled even if you are not using a hypervisor or an operating system that uses this option. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
IntelSpeedSelect (Intel(R) Speed Select) Member of Bios.v1_0_0.Bios
Description | Intel(R) Speed Select is available on only certain processor models.Speed Select processors have unique configurations that support higher base frequencies with fewer enabled core counts. Changing this setting will result in increasing the CPU base frequency along with a reduction in number of available cores. Consult documentation for the installed processor model for more information and core/frequency mappings of each configuration. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Base |
Base |
Config1 |
Config 1 |
Config2 |
Config 2 |
IntelTxt (Intel(R) TXT Support) Member of Bios.v1_0_0.Bios
Description | Use this option to modify Intel TXT support. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
IntelUpiFreq (Intel UPI Link Frequency) Member of Bios.v1_0_0.Bios
Description | Use this option to set the UPI Link frequency to a lower speed. Running at a lower frequency can reduce power consumption, but can also affect system performance. You can only configure this option if two or more CPUs are present and the Workload Profile is set to custom. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
MinUpiSpeed |
Min UPI Speed |
IntelUpiLinkEn (Intel UPI Link Enablement) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the UPI topology to use fewer links between processors, when available. Changing from the default can reduce UPI bandwidth performance in exchange for less power consumption. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
SingleLink |
Single Link Operation |
IntelUpiPowerManagement (Intel UPI Link Power Management) Member of Bios.v1_0_0.Bios
Description | Use this option to place the Quick Path Interconnect (UPI) links into a low power state when the links are not being used. This lowers power usage with minimal effect on performance. You can only configure this option if two or more CPUs are present and the Workload Profile is set to custom. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
IntelligentProvisioning (Intelligent Provisioning (F10 Prompt)) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable the Intelligent Provisioning functionality. When disabled, you are prevented from entering the Intelligent Provisioning environment by pressing F10 during server boot. You must set this option to enabled to use Intelligent Provisioning functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
InternalSDCardSlot (Internal SD Card Slot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable the Internal SD Card Slot. When set to disabled, the SD card slot is disabled, regardless of whether an SD Card is installed or not. The SD Card will not be visible in the pre-boot environment or under the operating system. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Ipv4Address (IPv4 Address) Member of Bios.v1_0_0.Bios
Description | Use this option to specify the pre-boot network IPv4 address. Enter a static IP address using dotted-decimal notation (for example, 127.0.0.1). If DHCP is used (the DHCPv4 option is enabled), this setting is unavailable because the value is supplied automatically. |
Type | String |
Read Only | False |
Ipv4Gateway (IPv4 Gateway) Member of Bios.v1_0_0.Bios
Description | Use this option to specify the pre-boot network gateway IPv4 address. Enter a static IP address using dotted-decimal notation (for example, 127.0.0.1). If DHCP is used (the DHCPv4 option is enabled), this setting is unavailable because the value is supplied automatically. |
Type | String |
Read Only | False |
Ipv4PrimaryDNS (IPv4 Primary DNS) Member of Bios.v1_0_0.Bios
Description | Use this option to specify the pre-boot network Primary DNS Server IPv4 address. Enter a static IP address using dotted-decimal notation (for example, 127.0.0.1). If DHCP is used (the DHCPv4 option is enabled), this setting is unavailable because the value is supplied automatically. |
Type | String |
Read Only | False |
Ipv4SecondaryDNS (IPv4 Secondary DNS) Member of Bios.v1_0_0.Bios
Description | Use this option to specify the pre-boot network Secondary DNS Server IPv4 address. Enter a static IP address using dotted-decimal notation (for example, 127.0.0.1). If DHCP is used (the DHCPv4 option is enabled), this setting is unavailable because the value is supplied automatically. |
Type | String |
Read Only | False |
Ipv4SubnetMask (IPv4 Subnet Mask) Member of Bios.v1_0_0.Bios
Description | Use this option to specify the pre-boot network subnet mask. Enter a static IP address using dotted-decimal notation (for example, 255.255.255.0). If DHCP is used (the DHCPv4 option is enabled), this setting is unavailable because the value is supplied automatically. |
Type | String |
Read Only | False |
Ipv6Address (IPv6 Address) Member of Bios.v1_0_0.Bios
Description | Use this option to specify the pre-boot network IPv6 address. Enter a static IP address in the standard colon seperated format (for example, 1234::1000). If IPv6 Config Policy is set to Automatic, this setting is unavailable because the value is supplied automatically. |
Type | String |
Read Only | False |
Ipv6ConfigPolicy (IPv6 Config Policy) Member of Bios.v1_0_0.Bios
Description | When set to Automatic, this option enables obtaining the pre-boot network IPv6 configuration automatically. Individual settings are not available. When set to Manual, you must configure static IP address settings individually. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Automatic |
Automatic |
Manual |
Manual |
Ipv6Duid (IPv6 DHCP Unique Identifier) Member of Bios.v1_0_0.Bios
Description | Use this option to control the IPv6 DHCP Unique Identifier (DUID). If configured for Auto, the DUID is set using the Universal Unique Identifier (UUID) of the server, or using the DUID-LLT method if the server UUID is not available. If configured for DUID-LLT, the DUID is set based on the Link-layer Address Plus Time [DUID-LLT] method. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
DuidLlt |
DUID-LLT |
Ipv6Gateway (IPv6 Gateway) Member of Bios.v1_0_0.Bios
Description | Use this option to specify the pre-boot network gateway IPv6 address. Enter a static IP address in the standard colon seperated format (for example, 1234::1000). If IPv6 Config Policy is set to Automatic, this setting is unavailable because the value is supplied automatically. |
Type | String |
Read Only | False |
Ipv6PrimaryDNS (IPv6 Primary DNS) Member of Bios.v1_0_0.Bios
Description | Use this option to specify the pre-boot network Primary DNS Server IPv6 address. Enter a static IP address in the standard colon seperated format (for example, 1234::1000). If IPv6 Config Policy is set to Automatic, this setting is unavailable because the value is supplied automatically. |
Type | String |
Read Only | False |
Ipv6SecondaryDNS (IPv6 Secondary DNS) Member of Bios.v1_0_0.Bios
Description | Use this option to specify the pre-boot network Secondary DNS Server IPv6 address. Enter a static IP address in the standard colon seperated format (for example, 1234::1000). If IPv6 Config Policy is set to Automatic, this setting is unavailable because the value is supplied automatically. |
Type | String |
Read Only | False |
LLCDeadLineAllocation (LLC Dead Line Allocation) Member of Bios.v1_0_0.Bios
Description | Enable - Opportunistically fill dead lines in LLC. Disable - Never fill dead lines in LLC. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
LlcPrefetch (LLC Prefetch) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the processor Last Level Cache (LLC) prefetch feature. In some cases, setting this option to disabled can improve performance. Typically, setting this option to enabled provides better performance. Only disable this option after performing application benchmarking to verify improved performance in the environment. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
LocalRemoteThreshold (Local/Remote Threshold) Member of Bios.v1_0_0.Bios
Description | Local/Remote Threshold setting. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Low |
Low |
Medium |
Medium |
High |
High |
Disabled |
Disabled |
MaxMemBusFreqMHz (Maximum Memory Bus Frequency) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the memory system to run memory at a lower maximum speed than that supported by the installed processor and DIMM configuration. Setting this option to Auto configures the system to run memory at the maximum speed supported. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
MaxMemBusFreq2933 |
2933 MHz |
MaxMemBusFreq2667 |
2667 MHz |
MaxMemBusFreq2400 |
2400 MHz |
MaxMemBusFreq2133 |
2133 MHz |
MaxMemBusFreq1867 |
1867 MHz |
MaxPcieSpeed (Maximum PCI Express Speed) Member of Bios.v1_0_0.Bios
Description | If a PCI Express device does not run properly at its optimal speed, lowering the speed at which the device is running can address this issue. This option enables you to lower the maximum PCI Express speed at which the server allows PCI Express devices to operate. You can also use it to address issues with problematic PCI Express devices. Setting this value to Maximum Supported configures the platform to run at the maximum speed supported by the platform or the PCIe device, whichever is lower. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
PerPortCtrl |
Per Port Control |
PcieGen1 |
PCIe Generation 1.0 |
MemClearWarmReset (Memory Clear on Warm Reset) Member of Bios.v1_0_0.Bios
Description | Use this option to configure when memory is cleared on warm resets. When disabled, the contents of memory are only cleared on a warm reset if requested by the operating system. When enabled, memory is cleared on all reboots. Disabling this option can save boot time by skipping the clearing of memory on warm resets. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
MemFastTraining (Memory Fast Training) Member of Bios.v1_0_0.Bios
Description | This option enables a boot time reduction by controlling when the BIOS bypasses the full memory training. When enabled, the server bypasses the full memory training during boot, and uses memory parameters determined on a previous boot to decrease boot time. Note that even when enabled, the BIOS performs a full memory training if the DIMM configuration or processor configuration changes, or if there is a change in any BIOS setting related to memory or processor configuration. When disabled, the server performs a full memory training on every server boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
MemMirrorMode (Memory Mirroring Mode) Member of Bios.v1_0_0.Bios
Description | Use this option to select from the available Memory Mirroring modes. Full Mirror - reserves 50% of the total available memory for mirroring. Partial Mirror (20% above 4GB) - reserves 20% of the total available Memory above 4GB for Mirroring. Partial Mirror (10% above 4GB) - reserves 10% of the total available Memory above 4GB for Mirroring. Partial Mirror (Memory below 4GB) - depending on the memory configuration, sets up 2GB or 3GB of lower memory below 4GB for Mirroring. Partial Mirror (OS Configured) - sets up the system to configure Partial Mirroring at OS level. This option will be not active and grayed out unless Advanced Memory Protection is set to Mirrored Memory with Advanced ECC Support. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Full |
Full Mirror |
PartialOsConfig |
Partial Mirror (OS Configured) |
PartialFirst4GB |
Partial Mirror (Memory below 4GB) |
Partial10PercentAbove4GB |
Partial Mirror (10% above 4GB) |
Partial20PercentAbove4GB |
Partial Mirror (20% above 4GB) |
MemPatrolScrubbing (Memory Patrol Scrubbing) Member of Bios.v1_0_0.Bios
Description | This option corrects memory soft errors so that, over the length of the system runtime, the risk of producing multi-bit and uncorrectable errors is reduced. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
MemRefreshRate (Memory Refresh Rate) Member of Bios.v1_0_0.Bios
Description | This option controls the refresh rate of the memory controller and might affect the performance and resiliency of the server memory. It is recommended that you leave this setting in the default state unless indicated in other documentation for this server. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Refreshx1 |
1x Refresh |
Refreshx2 |
2x Refresh |
MemoryControllerInterleaving (Memory Controller Interleaving) Member of Bios.v1_0_0.Bios
Description | Use this option to control the Memory Controller Interleaving option. When set to Auto, the system will automatically enable or disable memory controller interleaving based on the configuration of the system. When set to disabled, the user may force disable memory controller interleaving. In certain memory configurations, setting this option to disabled has showed a performance benefit across all memory in the system. It is recommended to leave this option to set to Auto. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
MemoryRemap (Memory Remap) Member of Bios.v1_0_0.Bios
Description | Use this option to remap memory that may have been previously disabled from the system due to a failure event, such as an uncorrectable memory error. The Remap All Memory Option causes the system to make all memory in the system available again on the next boot. The No Action option leaves any affected memory unavailable to the system. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoAction |
No Action |
AllMemory |
All Memory |
MinProcIdlePkgState (Minimum Processor Idle Power Package C-State) Member of Bios.v1_0_0.Bios
Description | You can configure this option only if the Workload Profile is set to Custom. Use this option to select the lowest idle package power state (C-state) of the processor. The processor automatically transitions into package C-states based on the Core C-states in which cores on the processor have transitioned. The higher the package C-state, the lower the power usage of that idle package state. (Package C6 (retention) is the lowest power idle package state supported by the processor). |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
C6Retention |
Package C6 (retention) State |
C6NonRetention |
Package C6 (non-retention) State |
NoState |
No Package State |
MinProcIdlePower (Minimum Processor Idle Power Core C-State) Member of Bios.v1_0_0.Bios
Description | You can only configure this option if Workload Profile is set to Custom. Use this option to select the lowest idle power state (C-state) of the processor that the operating system uses. The higher the C-state, the lower the power usage of that idle state. (C6 is the lowest power idle state supported by the processor). |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
C6 |
C6 State |
C1E |
C1E State |
NoCStates |
No C-states |
MixedPowerSupplyReporting (Mixed Power Supply Reporting) Member of Bios.v1_0_0.Bios
Description | When enabled, the server logs a message that a mixed power supply configuration is present. When disabled, the server no longer logs messages that a mixed power supply configuration is present. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NetworkBootRetry (Network Boot Retry Support) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the Network Boot Retry Support. When enabled, the system BIOS attempts to boot the network device up to the number of times configured in the Network Boot Retry Count option before attempting to boot the next network device. This setting only takes effect when attempting to boot a network device from the F12 function key and one-time boot options. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NetworkBootRetryCount (Network Boot Retry Count) Member of Bios.v1_0_0.Bios
Description | Use this option to control the number of times the system BIOS attempts to boot a network device. The valid range is from 0 to 20. |
Type | Integer |
Read Only | False |
NicBoot1 (Embedded NIC 1 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI, FCoE or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot10 (Embedded NIC 10 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI, FCoE or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot11 (Embedded NIC 11 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI, FCoE or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot12 (Embedded NIC 12 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI, FCoE or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot2 (Embedded NIC 2 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI, FCoE or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot3 (Embedded NIC 3 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI, FCoE or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot4 (Embedded NIC 4 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI, FCoE or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot5 (Embedded NIC 5 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI, FCoE or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot6 (Embedded NIC 6 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI, FCoE or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot7 (Embedded NIC 7 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI, FCoE or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot8 (Embedded NIC 8 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI, FCoE or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot9 (Embedded NIC 9 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI, FCoE or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NodeInterleaving (Node Interleaving) Member of Bios.v1_0_0.Bios
Description | Use this option to disable the NUMA architecture properties for the system. All operating system platforms support NUMA architectures. In most cases, optimum performance is obtained by disabling the Node Interleaving option. When this option is enabled, memory addresses are interleaved across the memory installed for each processor. Some workloads might experience improved performance when this option is enabled. Node Interleaving cannot be enabled when NVDIMMs are present in the system. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NumaGroupSizeOpt (NUMA Group Size Optimization) Member of Bios.v1_0_0.Bios
Description | Use this option to configure how the System BIOS reports the size of a NUMA node (number of logical processors), which assists the Operating System in grouping processors for application use (referred to as Kgroups). The default setting of Clustered provides better performance due to optimizing the resulting groups along NUMA boundaries. However, some applications might not be optimized to take advantage of processors spanning multiple groups. In such cases, selecting the Flat option might be necessary in order for those applications to utilize more logical processors. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Flat |
Flat |
Clustered |
Clustered |
NvDimmNMemFunctionality (NVDIMM-N Support) Member of Bios.v1_0_0.Bios
Description | This option controls whether NVDIMM-N support (including backing up the contents of the memory to flash on power down or reset) is enabled. If this option is configured for Disabled, then the NVDIMMs of type NVDIMM-N in the system are NOT used by the operating system as persistent storage, and are NOT used by the operating system as system memory. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvDimmNMemInterleaving (NVDIMM-N Interleaving) Member of Bios.v1_0_0.Bios
Description | This option controls whether the NVDIMMs of type NVDIMM-N installed on a particular processor will be interleaved with each other in the memory map. This option does NOT impact the interleaving of standard DIMMs, and interleaving is never enabled across NVDIMMs of type NVDIMM-N and standard DIMMs. NVDIMMs of type NVDIMM-N installed on different processors are never interleaved together. If this setting is changed, then all installed NVDIMMs of type NVDIMM-N must be sanitized. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvDimmNSanitizePolicy (NVDIMM-N Sanitize/Erase on Next Reboot Policy) Member of Bios.v1_0_0.Bios
Description | This option is used to Sanitize/Erase all user data and error status data saved in the selected NVDIMMs of type NVDIMM-N. Selected NVDIMMs of type NVDIMM-N are sanitized/erased on the next reboot of the system. This process is required BEFORE the NVDIMM-N Memory Interleaving option can be modified. An NVDIMM-N must be sanitized/erased when it is initially installed in the system or installed in a different DIMM slot on the system. In addition, an NVDIMM-N can be recovered to normal operation if it has received an Uncorrectable Memory Error, a Backup Error, a Restore Error, or an Arming Error (if the NVDIMM hardware is functional). Note that the largest group of NVDIMMs of type NVDIMM-N selected are sanitized/erased. For instance, if 'Sanitize/Erase all NVDIMM-N on Processor 1' is enabled and 'Sanitize/Erase Processor 1 DIMM 8' is disabled, all NVDIMMs of type NVDIMM-N on Processor 1 are sanitized/erased including Processor 1 DIMM 8. There are four policies that control the action of the system after NVDIMMs of type NVDIMM-N are sanitized/erased. The options are to power off the system after sanitizing/erasing NVDIMMs, to enable the system to boot to the operating system after sanitizing/erasing NVDIMMs, to boot to the System Utilities after sanitizing/erasing NVDIMMs, or to sanitize/erase the NVDIMMs back to the factory default settings and power off the system. 'Sanitize/Erase to Factory Defaults and Power System Off' is recommended when retiring the NVDIMMs with no intention of reuse. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
SanitizeAndRebootSystem |
Sanitize/Erase and Boot to Operating System |
SanitizeAndShutdownSystem |
Sanitize/Erase and Power System Off |
SanitizeAndBootToFirmwareUI |
Sanitize/Erase and Boot to System Utilities |
SanitizeToFactoryDefaults |
Sanitize/Erase to Factory Defaults and Power System Off |
NvdimmLabelSupport (NVDIMM-N OS Label Support) Member of Bios.v1_0_0.Bios
Description | Use this option to enable NVDIMM OS Label support via the ACPI methods _LSI, _LSR, and _LSW.When this option is enabled, the ACPI methods will be generated for each active NVDIMM in the system. When this option is disabled, those methods will not be generated. This option does NOT apply to Intel Optane Memory devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat1 (NVMe Drive 1) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat10 (NVMe Drive 10) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat11 (NVMe Drive 11) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat12 (NVMe Drive 12) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat13 (NVMe Drive 13) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat14 (NVMe Drive 14) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat15 (NVMe Drive 15) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat16 (NVMe Drive 16) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat17 (NVMe Drive 17) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat18 (NVMe Drive 18) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat19 (NVMe Drive 19) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat2 (NVMe Drive 2) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat20 (NVMe Drive 20) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat21 (NVMe Drive 21) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat22 (NVMe Drive 22) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat23 (NVMe Drive 23) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat24 (NVMe Drive 24) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat25 (NVMe Drive 25) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat26 (NVMe Drive 26) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat27 (NVMe Drive 27) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat28 (NVMe Drive 28) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat29 (NVMe Drive 29) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat3 (NVMe Drive 3) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat30 (NVMe Drive 30) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat31 (NVMe Drive 31) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat32 (NVMe Drive 32) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat33 (NVMe Drive 33) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat34 (NVMe Drive 34) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat35 (NVMe Drive 35) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat36 (NVMe Drive 36) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat37 (NVMe Drive 37) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat38 (NVMe Drive 38) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat39 (NVMe Drive 39) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat4 (NVMe Drive 4) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat40 (NVMe Drive 40) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat41 (NVMe Drive 41) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat42 (NVMe Drive 42) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat43 (NVMe Drive 43) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat44 (NVMe Drive 44) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat45 (NVMe Drive 45) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat46 (NVMe Drive 46) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat47 (NVMe Drive 47) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat48 (NVMe Drive 48) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat49 (NVMe Drive 49) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat5 (NVMe Drive 5) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat50 (NVMe Drive 50) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat6 (NVMe Drive 6) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat7 (NVMe Drive 7) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat8 (NVMe Drive 8) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeFormat9 (NVMe Drive 9) Member of Bios.v1_0_0.Bios
Description | Use this option to decommission NVM Express drives. Selected NVM Express drives are securely erased in the following boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NvmeOptionRom (Embedded NVM Express Option ROM) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable embedded NVM Express Option ROM. When enabled, the system loads the NVM Express Option ROM provided by the system BIOS. When disabled, the system loads the NVM Express Option ROM provided by the adapter. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
OpportunisticSelfRefresh (Opportunistic Self-Refresh) Member of Bios.v1_0_0.Bios
Description | Enables or disables opportunistic self-refresh. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciPeerToPeerSerialization (PCI Peer to Peer Serialization) Member of Bios.v1_0_0.Bios
Description | Select this option to configure the PCIe Peer to Peer Serialization Option. When set to enabled, PCIe transactions are interleaved across PCIe root ports of a processor which can result in increased performance in peer to peer communication. Certain configurations such as systems populated with multiple GPUs on a processor socket may see increased performance when this feature is enabled. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciResourcePadding (NVMe PCIe Resource Padding) Member of Bios.v1_0_0.Bios
Description | Use this option to configure PCIe resources to support PCIe hot-add for NVMe drives. When Normal is selected, PCIe resources are only allocated to devices installed at boot time, and PCIe hot-add is not supported. When Medium is selected, additional PCIe resources are allocated for each PCIe Root Port, which might enable a PCIe hot-add event to work without requiring a system reboot to enumerate the device. When High is selected, a maximum amount of PCIe resources are set aside to allow for the best chance of supporting a PCIe hot-add event. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Normal |
Normal |
Medium |
Medium |
High |
High |
PciSlot1Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device's link enters a standby energy savings state. When configured for L1 Enabled, the selected device's link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device's link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot1Bifurcation (PCIe Slot 1 Bifurcation) Member of Bios.v1_0_0.Bios
Description | Use this option to bifurcate the selected PCIe slot. When Auto is selected, the PCIe slot will train at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot1Enable (PCIe Device Disable) Member of Bios.v1_0_0.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot1LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot1OptionROM (PCIe Option ROM) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot2Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device's link enters a standby energy savings state. When configured for L1 Enabled, the selected device's link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device's link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot2Bifurcation (PCIe Slot 2 Bifurcation) Member of Bios.v1_0_0.Bios
Description | Use this option to bifurcate the selected PCIe slot. When Auto is selected, the PCIe slot will train at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot2Enable (PCIe Device Disable) Member of Bios.v1_0_0.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot2LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot2OptionROM (PCIe Option ROM) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot3Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device's link enters a standby energy savings state. When configured for L1 Enabled, the selected device's link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device's link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot3Bifurcation (PCIe Slot 3 Bifurcation) Member of Bios.v1_0_0.Bios
Description | Use this option to bifurcate the selected PCIe slot. When Auto is selected, the PCIe slot will train at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot3Enable (PCIe Device Disable) Member of Bios.v1_0_0.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot3LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot3OptionROM (PCIe Option ROM) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot4Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device's link enters a standby energy savings state. When configured for L1 Enabled, the selected device's link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device's link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot4Bifurcation (PCIe Slot 4 Bifurcation) Member of Bios.v1_0_0.Bios
Description | Use this option to bifurcate the selected PCIe slot. When Auto is selected, the PCIe slot will train at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot4Enable (PCIe Device Disable) Member of Bios.v1_0_0.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot4LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot4OptionROM (PCIe Option ROM) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot5Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device's link enters a standby energy savings state. When configured for L1 Enabled, the selected device's link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device's link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot5Bifurcation (PCIe Slot 5 Bifurcation) Member of Bios.v1_0_0.Bios
Description | Use this option to bifurcate the selected PCIe slot. When Auto is selected, the PCIe slot will train at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot5Enable (PCIe Device Disable) Member of Bios.v1_0_0.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot5LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot5OptionROM (PCIe Option ROM) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot6Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device's link enters a standby energy savings state. When configured for L1 Enabled, the selected device's link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device's link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot6Bifurcation (PCIe Slot 6 Bifurcation) Member of Bios.v1_0_0.Bios
Description | Use this option to bifurcate the selected PCIe slot. When Auto is selected, the PCIe slot will train at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot6Enable (PCIe Device Disable) Member of Bios.v1_0_0.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot6LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot6OptionROM (PCIe Option ROM) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot7Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device's link enters a standby energy savings state. When configured for L1 Enabled, the selected device's link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device's link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot7Bifurcation (PCIe Slot 7 Bifurcation) Member of Bios.v1_0_0.Bios
Description | Use this option to bifurcate the selected PCIe slot. When Auto is selected, the PCIe slot will train at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot7Enable (PCIe Device Disable) Member of Bios.v1_0_0.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot7LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot7OptionROM (PCIe Option ROM) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot8Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device's link enters a standby energy savings state. When configured for L1 Enabled, the selected device's link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device's link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot8Bifurcation (PCIe Slot 8 Bifurcation) Member of Bios.v1_0_0.Bios
Description | Use this option to bifurcate the selected PCIe slot. When Auto is selected, the PCIe slot will train at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot8Enable (PCIe Device Disable) Member of Bios.v1_0_0.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot8LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot8OptionROM (PCIe Option ROM) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PersistentMemAddressRangeScrub (Persistent Memory Address Range Scrub) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the NVDIMM memory Address Range Scrub support. When enabled, this option allows a supported OS to attempt recovery from an uncorrectable memory error detected in the NVDIMM memory. When disabled, the NVDIMM memory will be disabled on the following boot after detecting an uncorrectable memory error in the NVDIMM. If the NVDIMM memory Memory Interleaving option is enabled, a disabled NVDIMM will include all the modules or regions within the set. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PersistentMemBackupPowerPolicy (Persistent Memory Backup Power Policy) Member of Bios.v1_0_0.Bios
Description | This option controls whether the system waits during system boot for batteries to charge if sufficient battery backup power for the installed persistent memory is not available. If this option is configured for 'Continue Boot without Backup Power', the server boots even if sufficient battery backup power is not installed. In this case, if sufficient battery backup power is not enabled, the configured memory will NOT be used by the operating system as persistent storage or as system memory. If this option is configured for 'Use External Backup Power', the server will depend on an external UPS to handle an AC loss condition. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
WaitForBackupPower |
Wait for Backup Power on Boot |
BootWithoutBackupPower |
Continue Boot without Backup Power |
UseExternalBackupPower |
Use External Backup Power |
PersistentMemScanMem (Persistent Memory Integrity Check) Member of Bios.v1_0_0.Bios
Description | When this option is enabled, persistent memory will be checked during system boot to determine data integrity. Depending on the Persistent Memory Address Range Scrub setting, discovered errors during the data integrity check will either be presented to the operating system for recovery or cause the persistent memory to be mapped out and unavailable to the operating system. If this option is disabled, any persistent memory which has issues with the ability to read data or which has bad data may result in uncorrectable errors that result in a system crash. |
If this option is disabled, Persistent Memory Address Range Scrub functionality might be impacted.For NVDIMM-N, this option will be automatically enabled if Persistent Memory Address Range Scrub functionality is enabled. | |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PostBootProgress (POST Verbose Boot Progress) Member of Bios.v1_0_0.Bios
Description | Use this option to enable verbose boot progress messaging. Because this option displays additional debug information to the screen and serial console, it might be helpful for determining why a server became unresponsive during the boot process. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Serial |
Serial Only |
All |
All |
PostDiscoveryMode (UEFI POST Discovery Mode) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the UEFI POST Discovery Mode. When Auto is selected, the system selectively starts devices which are required for booting the devices in the UEFI Boot Order list. Note: For some situations like system configuration change, the system will change to start all devices for discovering all boot devices. When Force Full Discovery is selected, the system starts all devices in the system providing full boot target availability. Note: When Force Full Discovery is selected, boot time might significantly increase. When Force Fast Discovery is selected, the system starts as few devices as possible to get minimal boot time. Note: When Force Fast Discovery is selected, some unsupported devices may not work properly. You may need to replace the unsupported device with one that supports Fast Discovery. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
ForceFullDiscovery |
Force Full Discovery |
ForceFastDiscovery |
Force Fast Discovery |
PostF1Prompt (POST F1 Prompt) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the system to display the F1 key on the server POST screen. If an error is encountered, you can press the F1 key to continue with the server power-up sequence. Select one of the following options: |
Delayed 20 Seconds - If an error occurs, the system pauses for 20 seconds at the F1 prompt and continues to boot the OS. | |
Delayed 2 Seconds - If an error occurs, the system pauses for 2 seconds at the F1 prompt and continues to boot the OS. | |
Disabled - If an error occurs, the system bypasses the F1 prompt and continues to boot the OS. | |
Note: For critical errors, the system pauses for 20 seconds at the F1 prompt, regardless of how this option is configured. | |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Delayed20Sec |
Delayed 20 seconds |
Delayed2Sec |
Delayed 2 seconds |
Disabled |
Disabled |
PostVideoSupport (POST Video Support) Member of Bios.v1_0_0.Bios
Description | Use this option to configure the POST Video Support setting. When set to Display All, the system will display POST video to all installed video controllers. When set to Display Embedded Only, the system will only display POST video to the embedded video controller. This option is only supported in UEFI Boot Mode and only applies to video output during the POST (pre-boot) environment. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
DisplayAll |
Display All |
DisplayEmbeddedOnly |
Display Embedded Only |
PowerButton (Power Button Mode) Member of Bios.v1_0_0.Bios
Description | Disabling this option disables the momentary power button functionality. This option does not affect the four-second power button override or the remote power control functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PowerOnDelay (Power-On Delay) Member of Bios.v1_0_0.Bios
Description | Use this option to delay the server from turning on for a specified time. Pressing the power button (using the Virtual Power Button), or Wake-ON LAN events, and RTC Wake-up events override the delay and power on the server without any additional delay. This enables staggering when servers power-up after a power loss to prevent power usage spikes.Note that the actual delay before the server is powered on will be longer than the specified time because the server must always wait for iLO FW to initialize before the server attempts to power on. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoDelay |
No Delay |
Random |
Random Delay |
Delay15Sec |
15 Second Delay |
Delay30Sec |
30 Second Delay |
Delay45Sec |
45 Second Delay |
Delay60Sec |
60 Second Delay |
PowerRegulator (Power Regulator) Member of Bios.v1_0_0.Bios
Description | You can only configure this option if the Workload Profile is set to Custom. Use this option to configure the following Power Regulator support: |
- Dynamic Power Savings Mode: Automatically varies processor speed and power usage based on processor utilization. Enables the reduction of overall power consumption with little or no impact on performance. Does not require OS support.
- Static Low Power Mode: Reduces processor speed and power usage. Guarantees a lower maximum power usage for the system. Performance impacts are greater for environments with higher processor utilization.
- Static High Performance Mode: Processors run in their maximum power/performance state at all times, regardless of the OS power management policy.
- OS Control Mode: Processors run in their maximum power/performance state at all times unless the OS enables a power management policy.| |Type|Enumeration| |Read Only|False|
Value | Description |
---|---|
DynamicPowerSavings |
Dynamic Power Savings Mode |
StaticLowPower |
Static Low Power Mode |
StaticHighPerf |
Static High Performance Mode |
OsControl |
OS Control Mode |
PreBootNetwork (Pre-Boot Network Interface) Member of Bios.v1_0_0.Bios
Description | Use this option to select the network interface used for pre-boot network connections. When the selection is Auto, the system uses the first available port with a network connection. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
EmbNicPort1 |
Embedded NIC Port 1 |
EmbNicPort2 |
Embedded NIC Port 2 |
EmbNicPort3 |
Embedded NIC Port 3 |
EmbNicPort4 |
Embedded NIC Port 4 |
EmbNicPort5 |
Embedded NIC Port 5 |
EmbNicPort6 |
Embedded NIC Port 6 |
EmbNicPort7 |
Embedded NIC Port 7 |
EmbNicPort8 |
Embedded NIC Port 8 |
FlexLom1Port1 |
Embedded FlexibleLOM 1 Port 1 |
FlexLom1Port2 |
Embedded FlexibleLOM 1 Port 2 |
FlexLom1Port3 |
Embedded FlexibleLOM 1 Port 3 |
FlexLom1Port4 |
Embedded FlexibleLOM 1 Port 4 |
FlexLom1Port5 |
Embedded FlexibleLOM 1 Port 5 |
FlexLom1Port6 |
Embedded FlexibleLOM 1 Port 6 |
FlexLom1Port7 |
Embedded FlexibleLOM 1 Port 7 |
FlexLom1Port8 |
Embedded FlexibleLOM 1 Port 8 |
Slot1NicPort1 |
Slot 1 NIC Port 1 |
Slot1NicPort2 |
Slot 1 NIC Port 2 |
Slot1NicPort3 |
Slot 1 NIC Port 3 |
Slot1NicPort4 |
Slot 1 NIC Port 4 |
Slot1NicPort5 |
Slot 1 NIC Port 5 |
Slot1NicPort6 |
Slot 1 NIC Port 6 |
Slot1NicPort7 |
Slot 1 NIC Port 7 |
Slot1NicPort8 |
Slot 1 NIC Port 8 |
Slot2NicPort1 |
Slot 2 NIC Port 1 |
Slot2NicPort2 |
Slot 2 NIC Port 2 |
Slot2NicPort3 |
Slot 2 NIC Port 3 |
Slot2NicPort4 |
Slot 2 NIC Port 4 |
Slot2NicPort5 |
Slot 2 NIC Port 5 |
Slot2NicPort6 |
Slot 2 NIC Port 6 |
Slot2NicPort7 |
Slot 2 NIC Port 7 |
Slot2NicPort8 |
Slot 2 NIC Port 8 |
Slot3NicPort1 |
Slot 3 NIC Port 1 |
Slot3NicPort2 |
Slot 3 NIC Port 2 |
Slot3NicPort3 |
Slot 3 NIC Port 3 |
Slot3NicPort4 |
Slot 3 NIC Port 4 |
Slot3NicPort5 |
Slot 3 NIC Port 5 |
Slot3NicPort6 |
Slot 3 NIC Port 6 |
Slot3NicPort7 |
Slot 3 NIC Port 7 |
Slot3NicPort8 |
Slot 3 NIC Port 8 |
Slot4NicPort1 |
Slot 4 NIC Port 1 |
Slot4NicPort2 |
Slot 4 NIC Port 2 |
Slot4NicPort3 |
Slot 4 NIC Port 3 |
Slot4NicPort4 |
Slot 4 NIC Port 4 |
Slot4NicPort5 |
Slot 4 NIC Port 5 |
Slot4NicPort6 |
Slot 4 NIC Port 6 |
Slot4NicPort7 |
Slot 4 NIC Port 7 |
Slot4NicPort8 |
Slot 4 NIC Port 8 |
Slot5NicPort1 |
Slot 5 NIC Port 1 |
Slot5NicPort2 |
Slot 5 NIC Port 2 |
Slot5NicPort3 |
Slot 5 NIC Port 3 |
Slot5NicPort4 |
Slot 5 NIC Port 4 |
Slot5NicPort5 |
Slot 5 NIC Port 5 |
Slot5NicPort6 |
Slot 5 NIC Port 6 |
Slot5NicPort7 |
Slot 5 NIC Port 7 |
Slot5NicPort8 |
Slot 5 NIC Port 8 |
Slot6NicPort1 |
Slot 6 NIC Port 1 |
Slot6NicPort2 |
Slot 6 NIC Port 2 |
Slot6NicPort3 |
Slot 6 NIC Port 3 |
Slot6NicPort4 |
Slot 6 NIC Port 4 |
Slot6NicPort5 |
Slot 6 NIC Port 5 |
Slot6NicPort6 |
Slot 6 NIC Port 6 |
Slot6NicPort7 |
Slot 6 NIC Port 7 |
Slot6NicPort8 |
Slot 6 NIC Port 8 |
Slot7NicPort1 |
Slot 7 NIC Port 1 |
Slot7NicPort2 |
Slot 7 NIC Port 2 |
Slot7NicPort3 |
Slot 7 NIC Port 3 |
Slot7NicPort4 |
Slot 7 NIC Port 4 |
Slot7NicPort5 |
Slot 7 NIC Port 5 |
Slot7NicPort6 |
Slot 7 NIC Port 6 |
Slot7NicPort7 |
Slot 7 NIC Port 7 |
Slot7NicPort8 |
Slot 7 NIC Port 8 |
Slot8NicPort1 |
Slot 8 NIC Port 1 |
Slot8NicPort2 |
Slot 8 NIC Port 2 |
Slot8NicPort3 |
Slot 8 NIC Port 3 |
Slot8NicPort4 |
Slot 8 NIC Port 4 |
Slot8NicPort5 |
Slot 8 NIC Port 5 |
Slot8NicPort6 |
Slot 8 NIC Port 6 |
Slot8NicPort7 |
Slot 8 NIC Port 7 |
Slot8NicPort8 |
Slot 8 NIC Port 8 |
PrebootNetworkEnvPolicy (Pre-Boot Network Environment) Member of Bios.v1_0_0.Bios
Description | Use this option to set the preference for Pre-Boot Network. |
If configured for Auto, all the network operations initiated in the pre boot environment occur over IPv4 or IPv6. The order of the existing network boot targets is not modified in the UEFI Boot Order list. New network boot targets are added to the end of the list using the default policy of the System BIOS. | |
If configured for IPv4, all the network operations initiated in the pre boot environment only occur over IPv4. All existing IPv6 network boot targets are removed in the UEFI Boot Order. No new IPv6 network boot targets are added to the list. | |
If configured for IPv6, all the network operations initiated in the pre boot environment only occur over IPv6. All existing IPv4 network boot targets in the UEFI Boot Order are removed. No new IPv4 network boot targets are added to the list. |
| |Type|Enumeration| |Read Only|False|
Value | Description |
---|---|
Auto |
Auto |
IPv4 |
IPv4 |
IPv6 |
IPv6 |
PrebootNetworkProxy (Pre-Boot Network Proxy) Member of Bios.v1_0_0.Bios
Description | Use this option to configure a pre-boot network proxy. When set, network operations for 'Pre-Boot Network Interface' are attempted through the configured proxy. The proxy must be in a HTTP URL format, and can be specified as http://IPv4_address:port, http://IPv6 address:port or http://FQDN:port. |
Type | String |
Read Only | False |
ProcAes (Processor AES-NI Support) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable the Advanced Encryption Standard Instruction Set (AES-NI) in the processor. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
ProcHyperthreading (Intel(R) Hyper-Threading) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable Intel Hyper-Threading. When enabled, each physical processor core operates as two logical processor cores. When disabled, each physical processor core operates as one logical processor core. Enabling this option can improve overall performance for applications that benefit from a higher processor core count. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
ProcTurbo (Intel(R) Turbo Boost Technology) Member of Bios.v1_0_0.Bios
Description | Turbo Boost Technology enables the processor to transition to a higher frequency than the processor's rated speed if the processor has available power and is within temperature specifications. Disabling this option reduces power usage, and also reduces the system's maximum achievable performance under some workloads. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Enabled |
Enabled |
ProcVirtualization (Intel(R) Virtualization Technology (Intel VT) ) Member of Bios.v1_0_0.Bios
Description | When enabled, a hypervisor or operating system supporting this option can use hardware capabilities provided by Intel VT. Some hypervisors require that you enable Intel VT. You can leave this set to enabled even if you are not using a hypervisor or an operating system that uses this option. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
ProcX2Apic (Processor x2APIC Support) Member of Bios.v1_0_0.Bios
Description | x2APIC support enables operating systems to run more efficiently on high core count configurations. It also optimizes interrupt distribution in virtualized environments. In most cases, set this option to enabled. This configures the operating system to optionally enable x2APIC support when it loads. Some older hypervisors and operating systems might have issues with optional x2APIC support, in which case disabling x2APIC might be necessary to address those issues. Additionally, some hypervisors and operating systems will not use X2APIC unless this option is set to Force Enabled prior to booting. The Force Enabled option also causes the Intel(R) VT-d setting to be set to enabled. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
ForceEnabled |
Force Enabled |
Disabled |
Disabled |
ProcessorConfigTDPLevel (Processor Config TDP Level) Member of Bios.v1_0_0.Bios
Description | Use this option to override the default CPU policy for SSE, AVX, and AVX-512 deterministic frequencies.This will result in lowering the deterministic operational frequency (P1) based on the setting.Disabling Turbo Mode will enhance the deterministic behavior, but result in a lower operational frequency. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Normal |
Normal |
Level1 |
Level 1 |
Level2 |
Level 2 |
ProcessorJitterControl (Processor Jitter Control) Member of Bios.v1_0_0.Bios
Description | Processor Jitter Control allows the customer to manage processor frequency variance to do technologies such as Turbo which vary the frequency based on power, thermals, and active cores. When configured for Auto-tuned, the platform will monitor frequency variance and automatically make adjustments to minimize variance over time. When configured for Manual-tuned, the customer can choose to attempt to operate the processor at a fixed frequency and can select lower or higher frequencies statically.Note:Auto-tuned mode requires that processor C-states be disabled for proper operation. Refer to the Intelligent System Tuning Whitepaper at hpe.com/info/IST on how to properly disable C-states in UEFI System Utilities and/or the Linux Operating System. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Auto-tuned |
Auto-tuned |
Manual-tuned |
Manual-tuned |
ProcessorJitterControlFrequency (Processor Jitter Control Frequency) Member of Bios.v1_0_0.Bios
Description | Processor Jitter Control Frequency allows the customer to stipulate the starting frequency in the Auto-tuned mode, or the desired frequency in the Manual-tuned mode. The input frequency is in units of Megahertz. System firmware will adjust the frequency to the nearest higher intermediate frequency supported by the processor if the input frequency is not supported. |
Type | Integer |
Read Only | False |
ProcessorJitterControlOptimization (Processor Jitter Control Optimization) Member of Bios.v1_0_0.Bios
Description | This option optimizes the thresholds used when the Auto-tuned function detects fluctuations in processor frequency. Optimizing for throughput allows only the amount of fluctuations that doesn't impact overall compute throughput. Optimizing for Latency allows for a very small amount of occasional fluctuations to occur before reducing processor frequency. Zero Latency attempts to eliminate any frequency fluctuations. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
OptimizedForThroughput |
Optimized for Throughput |
OptimizedForLatency |
Optimized for Latency |
ZeroLatency |
Zero Latency |
ProductId (Product ID) Member of Bios.v1_0_0.Bios
Description | Use this option to set the system product ID. This value must always match the product ID sticker located on the chassis. |
Type | String |
Read Only | False |
RedundantPowerSupply (Redundant Power Supply Mode) Member of Bios.v1_0_0.Bios
Description | Use this option to configure how the system handles redundant power supply configurations. Balanced Mode shares the power delivery equally between all installed power supplies. All High Efficiency Mode options provide the most power efficient operation with redundant power supplies by keeping half of the power supplies in standby mode at lower power usage levels. The High Efficiency Mode options enable the system to select which power supply to place in standby. Auto enables the system to select between the odd or even power supply based on a semi-random distribution within a group of systems. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
BalancedMode |
Balanced Mode |
HighEfficiencyAuto |
High Efficiency Mode (Auto) |
HighEfficiencyOddStandby |
High Efficiency Mode (Odd Supply Standby) |
HighEfficiencyEvenStandby |
High Efficiency Mode (Even Supply Standby) |
RemovableFlashBootSeq (Removable Flash Media Boot Sequence) Member of Bios.v1_0_0.Bios
Description | Use this option to select which USB or SD Card devices you want to search for first when enumerating boot devices. You can select whether the system boots to external USB drive keys, internal USB drive keys, or the internal SD card slot. This option does not override the device boot order in the Standard Boot Order (IPL) option. You can only configure this option when Boot Mode is set to Legacy BIOS. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
InternalSdCardFirst |
Internal SD Card First |
InternalKeysFirst |
Internal DriveKeys First |
ExternalKeysFirst |
External DriveKeys First |
RestoreDefaults (Restore Default System Settings) Member of Bios.v1_0_0.Bios
Description | Use this option to reset all configuration settings to their default values. Changes that have been made might be lost. You must reboot the system for changes to take effect. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
No |
No, cancel the restore procedure. |
Yes |
Yes, restore the default settings. |
RestoreManufacturingDefaults (Restore Default Manufacturing Settings) Member of Bios.v1_0_0.Bios
Description | Use this option to reset all configuration settings to their default manufacturing values. Changes that have been made might be lost. If Secure Boot is enabled, related security settings might be lost. You must reboot the system for changes to take effect. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
No |
No, cancel restore procedure. |
Yes |
Yes, restore the default settings. |
RomSelection (ROM Selection) Member of Bios.v1_0_0.Bios
Description | Use this option to revert the server to a previous BIOS ROM image. The backup image is the BIOS ROM image that was used prior to the last flash event. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
CurrentRom |
Use Current ROM |
BackupRom |
Switch to Backup ROM |
SanitizeAllNvDimmN (Sanitize/Erase all NVDIMM-N in the System) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in ALL NVDIMMs of type NVDIMM-N in the system are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc1Dimm1 (Sanitize/Erase Processor 1 DIMM 1) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc1Dimm10 (Sanitize/Erase Processor 1 DIMM 10) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc1Dimm11 (Sanitize/Erase Processor 1 DIMM 11) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc1Dimm12 (Sanitize/Erase Processor 1 DIMM 12) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc1Dimm2 (Sanitize/Erase Processor 1 DIMM 2) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc1Dimm3 (Sanitize/Erase Processor 1 DIMM 3) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc1Dimm4 (Sanitize/Erase Processor 1 DIMM 4) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc1Dimm5 (Sanitize/Erase Processor 1 DIMM 5) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc1Dimm6 (Sanitize/Erase Processor 1 DIMM 6) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc1Dimm7 (Sanitize/Erase Processor 1 DIMM 7) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc1Dimm8 (Sanitize/Erase Processor 1 DIMM 8) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc1Dimm9 (Sanitize/Erase Processor 1 DIMM 9) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc1NvDimmN (Sanitize/Erase all NVDIMM-N on Processor 1) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in ALL NVDIMMs of type NVDIMM-N installed on the selected processor are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc2Dimm1 (Sanitize/Erase Processor 2 DIMM 1) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc2Dimm10 (Sanitize/Erase Processor 2 DIMM 10) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc2Dimm11 (Sanitize/Erase Processor 2 DIMM 11) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc2Dimm12 (Sanitize/Erase Processor 2 DIMM 12) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc2Dimm2 (Sanitize/Erase Processor 2 DIMM 2) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc2Dimm3 (Sanitize/Erase Processor 2 DIMM 3) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc2Dimm4 (Sanitize/Erase Processor 2 DIMM 4) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc2Dimm5 (Sanitize/Erase Processor 2 DIMM 5) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc2Dimm6 (Sanitize/Erase Processor 2 DIMM 6) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc2Dimm7 (Sanitize/Erase Processor 2 DIMM 7) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc2Dimm8 (Sanitize/Erase Processor 2 DIMM 8) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc2Dimm9 (Sanitize/Erase Processor 2 DIMM 9) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in the selected NVDIMM-N are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SanitizeProc2NvDimmN (Sanitize/Erase all NVDIMM-N on Processor 2) Member of Bios.v1_0_0.Bios
Description | When Enabled, all user data in ALL NVDIMMs of type NVDIMM-N installed on the selected processor are erased on the next reboot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SataSecureErase (SATA Secure Erase) Member of Bios.v1_0_0.Bios
Description | Use this option to control whether Secure Erase functionality is supported. When enabled, the Security Freeze Lock command is not sent to supported SATA hard drives, enabling Secure erase to function (the Secure Erase command is supported). This option is only supported when the SATA controller is in AHCI mode. Secure Erase only operates with hard drives that support the Secure Erase command. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SaveUserDefaults (Save User Defaults) Member of Bios.v1_0_0.Bios
Description | Select this option to save the current settings as the system defaults. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
No |
No, Cancel |
Yes |
Yes, Save |
SecStartBackupImage (Backup ROM Image Authentication) Member of Bios.v1_0_0.Bios
Description | Use this option to enable cryptographic authentication of the backup ROM image on startup. When this option is disabled, only the primary image is authenticated on each startup. Enable this option to also perform cryptographic authentication of the backup ROM image. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SecureBootStatus (Secure Boot Status) Member of Bios.v1_0_0.Bios
Description | The current state of Secure Boot configuration. |
Type | Enumeration |
Read Only | True |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SerialConsoleBaudRate (BIOS Serial Console Baud Rate) Member of Bios.v1_0_0.Bios
Description | This is the transfer rate at which data is transmitted through the serial port. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
BaudRate9600 |
9600 |
BaudRate19200 |
19200 |
BaudRate38400 |
38400 |
BaudRate57600 |
57600 |
BaudRate115200 |
115200 |
SerialConsoleEmulation (BIOS Serial Console Emulation Mode) Member of Bios.v1_0_0.Bios
Description | Use this option to select the emulation mode type. The option you select depends on the emulation you want to use in your serial terminal program (such as HyperTerminal or PuTTy). The BIOS emulation mode must match the mode you select in your terminal program. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Vt100 |
VT100 |
Ansi |
ANSI |
Vt100Plus |
VT100+ |
VtUtf8 |
VT-UTF8 |
SerialConsolePort (BIOS Serial Console Port) Member of Bios.v1_0_0.Bios
Description | Use this option to re-direct video and keystrokes through the serial port to OS boot. This option can interfere with non-terminal devices attached to the serial port. In such cases, set this option to disabled. This option is only supported in English language mode when running in the UEFI pre-boot System Utilities. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
Physical |
Physical Serial Port |
Virtual |
Virtual Serial Port |
SerialNumber (Serial Number) Member of Bios.v1_0_0.Bios
Description | Use this option to set the system serial number. This value must always match the serial number sticker located on the chassis. |
Type | String |
Read Only | False |
ServerAssetTag (Server Asset Tag) Member of Bios.v1_0_0.Bios
Description | Select this option to modify the Server Asset Tag text line. |
Type | String |
Read Only | False |
ServerConfigLockStatus (Server Configuration Lock Status) Member of Bios.v1_0_0.Bios
Description | The current state of the Server Configuration Lock feature. |
Type | Enumeration |
Read Only | True |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
ServerName (Server Name) Member of Bios.v1_0_0.Bios
Description | Select this option to modify the server name text line. |
Type | String |
Read Only | False |
ServerOtherInfo (Server Other Information) Member of Bios.v1_0_0.Bios
Description | Use this option to modify the Other Server text line. |
Type | String |
Read Only | False |
ServerPrimaryOs (Server Primary OS) Member of Bios.v1_0_0.Bios
Description | Use this option to modify the Server Primary OS text line. |
Type | String |
Read Only | False |
ServiceEmail (Service Contact E-mail Address) Member of Bios.v1_0_0.Bios
Description | Enter the server service contact e-mail address. |
Type | String |
Read Only | False |
ServiceName (Service Contact Name) Member of Bios.v1_0_0.Bios
Description | Enter the server service contact name text. |
Type | String |
Read Only | False |
ServiceOtherInfo (Service Contact Other Information) Member of Bios.v1_0_0.Bios
Description | Enter the other server service contact information text. |
Type | String |
Read Only | False |
ServicePhone (Service Contact Phone Number) Member of Bios.v1_0_0.Bios
Description | Enter the server service contact phone number text. |
Type | String |
Read Only | False |
SetupBrowserSelection (Setup Browser Selection) Member of Bios.v1_0_0.Bios
Description | Select which setup browser to use: GUI or Text. Auto mode uses text when the user enters RBSU via serial console, and uses GUI via IRC or physical terminal. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
GUI |
GUI |
Text |
Text |
Auto |
Auto |
Slot1NicBoot1 (Slot 1 NIC Port 1 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot1NicBoot2 (Slot 1 NIC Port 2 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot1NicBoot3 (Slot 1 NIC Port 3 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot1NicBoot4 (Slot 1 NIC Port 4 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot1NicBoot5 (Slot 1 NIC Port 5 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot1NicBoot6 (Slot 1 NIC Port 6 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot1NicBoot7 (Slot 1 NIC Port 7 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot1NicBoot8 (Slot 1 NIC Port 8 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot1StorageBoot (PCIe Slot 1) Member of Bios.v1_0_0.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 24 Targets is selected, 24 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
TwentyFourTargets |
Boot Limit to 24 Targets |
NoTargets |
Boot No Targets |
Slot2NicBoot1 (Slot 2 NIC Port 1 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot2NicBoot2 (Slot 2 NIC Port 2 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot2NicBoot3 (Slot 2 NIC Port 3 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot2NicBoot4 (Slot 2 NIC Port 4 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot2NicBoot5 (Slot 2 NIC Port 5 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot2NicBoot6 (Slot 2 NIC Port 6 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot2NicBoot7 (Slot 2 NIC Port 7 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot2NicBoot8 (Slot 2 NIC Port 8 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot2StorageBoot (PCIe Slot 2) Member of Bios.v1_0_0.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 24 Targets is selected, 24 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
TwentyFourTargets |
Boot Limit to 24 Targets |
NoTargets |
Boot No Targets |
Slot3NicBoot1 (Slot 3 NIC Port 1 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot3NicBoot2 (Slot 3 NIC Port 2 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot3NicBoot3 (Slot 3 NIC Port 3 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot3NicBoot4 (Slot 3 NIC Port 4 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot3NicBoot5 (Slot 3 NIC Port 5 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot3NicBoot6 (Slot 3 NIC Port 6 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot3NicBoot7 (Slot 3 NIC Port 7 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot3NicBoot8 (Slot 3 NIC Port 8 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot3StorageBoot (PCIe Slot 3) Member of Bios.v1_0_0.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 24 Targets is selected, 24 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
TwentyFourTargets |
Boot Limit to 24 Targets |
NoTargets |
Boot No Targets |
Slot4NicBoot1 (Slot 4 NIC Port 1 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot4NicBoot2 (Slot 4 NIC Port 2 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot4NicBoot3 (Slot 4 NIC Port 3 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot4NicBoot4 (Slot 4 NIC Port 4 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot4NicBoot5 (Slot 4 NIC Port 5 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot4NicBoot6 (Slot 4 NIC Port 6 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot4NicBoot7 (Slot 4 NIC Port 7 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot4NicBoot8 (Slot 4 NIC Port 8 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot4StorageBoot (PCIe Slot 4) Member of Bios.v1_0_0.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 24 Targets is selected, 24 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
TwentyFourTargets |
Boot Limit to 24 Targets |
NoTargets |
Boot No Targets |
Slot5NicBoot1 (Slot 5 NIC Port 1 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot5NicBoot2 (Slot 5 NIC Port 2 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot5NicBoot3 (Slot 5 NIC Port 3 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot5NicBoot4 (Slot 5 NIC Port 4 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot5NicBoot5 (Slot 5 NIC Port 5 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot5NicBoot6 (Slot 5 NIC Port 6 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot5NicBoot7 (Slot 5 NIC Port 7 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot5NicBoot8 (Slot 5 NIC Port 8 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot5StorageBoot (PCIe Slot 5) Member of Bios.v1_0_0.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 24 Targets is selected, 24 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
TwentyFourTargets |
Boot Limit to 24 Targets |
NoTargets |
Boot No Targets |
Slot6NicBoot1 (Slot 6 NIC Port 1 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot6NicBoot2 (Slot 6 NIC Port 2 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot6NicBoot3 (Slot 6 NIC Port 3 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot6NicBoot4 (Slot 6 NIC Port 4 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot6NicBoot5 (Slot 6 NIC Port 5 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot6NicBoot6 (Slot 6 NIC Port 6 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot6NicBoot7 (Slot 6 NIC Port 7 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot6NicBoot8 (Slot 6 NIC Port 8 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot6StorageBoot (PCIe Slot 6) Member of Bios.v1_0_0.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 24 Targets is selected, 24 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
TwentyFourTargets |
Boot Limit to 24 Targets |
NoTargets |
Boot No Targets |
Slot7NicBoot1 (Slot 7 NIC Port 1 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot7NicBoot2 (Slot 7 NIC Port 2 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot7NicBoot3 (Slot 7 NIC Port 3 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot7NicBoot4 (Slot 7 NIC Port 4 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot7StorageBoot (PCIe Slot 7) Member of Bios.v1_0_0.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 24 Targets is selected, 24 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
TwentyFourTargets |
Boot Limit to 24 Targets |
NoTargets |
Boot No Targets |
Slot8NicBoot1 (Slot 8 NIC Port 1 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot8NicBoot2 (Slot 8 NIC Port 2 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot8NicBoot3 (Slot 8 NIC Port 3 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot8NicBoot4 (Slot 8 NIC Port 4 Boot) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable UEFI PXE Boot, UEFI HTTP Boot and iSCSI Software Initiator for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot8StorageBoot (PCIe Slot 8) Member of Bios.v1_0_0.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 24 Targets is selected, 24 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
TwentyFourTargets |
Boot Limit to 24 Targets |
NoTargets |
Boot No Targets |
Sriov (SR-IOV) Member of Bios.v1_0_0.Bios
Description | If enabled, SR-IOV support enables a hypervisor to create virtual instances of a PCI-express device, potentially increasing performance. If enabled, the BIOS allocates additional resources to PCI-express devices. You can leave this option set to enabled even if you are not using a hypervisor. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
StaleAtoS (Stale A to S) Member of Bios.v1_0_0.Bios
Description | Stale A to S directory optimization. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SubNumaClustering (Sub-NUMA Clustering) Member of Bios.v1_0_0.Bios
Description | When enabled, Sub-NUMA Clustering divides the processor's cores, cache, and memory into multiple NUMA domains. Enabling this feature can increase performance for workloads that are NUMA aware and optimized. |
Note: When this option is enabled, up to 1GB of system memory may become unavailable. | |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
ThermalConfig (Thermal Configuration) Member of Bios.v1_0_0.Bios
Description | Use this option to select the fan cooling solution for the system. Optimal Cooling provides the most efficient solution by configuring fan speeds to the minimum required speed to provide adequate cooling. Increased Cooling runs fans at higher speeds to provide additional cooling. Select Increased Cooling when third-party storage controllers are cabled to the embedded hard drive cage, or if the system is experiencing thermal issues that cannot be resolved. Maximum cooling provides the maximum cooling available on this platform. Enhanced CPU Cooling runs the fans at a higher speed to provide additional cooling to the processors. Selecting Enhanced CPU Cooling may improve system performance with certain processor intensive workloads. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
OptimalCooling |
Optimal Cooling |
IncreasedCooling |
Increased Cooling |
MaxCooling |
Maximum Cooling |
EnhancedCPUCooling |
Enhanced CPU Cooling |
ThermalShutdown (Thermal Shutdown) Member of Bios.v1_0_0.Bios
Description | Use this option to control the reaction of the system to caution level thermal events. When disabled, the System Management Firmware ignores thermal events, and the system immediately powers off in data-destructive situations. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
TimeFormat (Time Format) Member of Bios.v1_0_0.Bios
Description | This option controls how the system time is stored in the hardware Real Time Clock (RTC). When configured to 'Coordinated Universal Time (UTC)' (default) the local time is calculated from the associated time zone value. When configured to 'Local Time' the time is stored directly as local time and the time zone option does not have meaning. Setting this option to 'Local Time' works around an issue when using Microsoft Windows operating systems in Legacy Boot Mode where the time is set incorrectly. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Utc |
Coordinated Universal Time (UTC) |
Local |
Local Time |
TimeZone (Time Zone) Member of Bios.v1_0_0.Bios
Description | This option displays the current time zone setting for the system. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
UtcM12 |
UTC-12:00, International Date Line West |
UtcM11 |
UTC-11:00, Midway Island, Samoa |
UtcM10 |
UTC-10:00, Hawaii |
UtcM9 |
UTC-09:00, Alaska |
UtcM8 |
UTC-08:00, Pacific Time(US & Canada) |
UtcM7 |
UTC-07:00, Mountain Time (US & Canada) |
UtcM6 |
UTC-06:00, Central America, Central Time(US & Canada) |
UtcM5 |
UTC-05:00, Eastern Time(US & Canada) |
UtcM430 |
UTC-04:30, Caracas |
UtcM4 |
UTC-04:00, Atlantic Time(Canada), Caracas, Santiago |
UtcM330 |
UTC-03:30, Newfoundland |
UtcM3 |
UTC-03:00, Brasilia, Buenos Aires, Georgetown, Greenland |
UtcM2 |
UTC-02:00, Mid-Atlantic |
UtcM1 |
UTC-01:00, Azores, Cape Verde Is. |
Utc0 |
UTC-00:00, Greenwich Mean Time, Dublin, London |
UtcP1 |
UTC+01:00, Amsterdam, Berlin, Rome, Paris, West Central Africa |
UtcP2 |
UTC+02:00, Athens, Istanbul, Cairo, Jerusalem |
UtcP3 |
UTC+03:00, Baghdad, Kuwait, Riyadh, Moscow, Nairobi |
UtcP330 |
UTC+03:30, Tehran |
UtcP4 |
UTC+04:00, Abu Dhabi, Muscat, Baku, Tbilisi, Yerevan |
UtcP430 |
UTC+04:30, Kabul |
UtcP5 |
UTC+05:00, Ekaterinburg, Islamabad, Karachi, Tashkent |
UtcP530 |
UTC+05:30, Chennai, Kolkata, Mumbai, New Delhi |
UtcP545 |
UTC+05:45, Kathmandu |
UtcP6 |
UTC+06:00, Almaty, Novosibirsk, Astana, Dhaka |
UtcP630 |
UTC+06:30, Rangoon |
UtcP7 |
UTC+07:00, Bangkok, Hanoi, Jakarta, Krasnoyarsk |
UtcP8 |
UTC+08:00, Taipei, Beijing, Chongqing, Hong Kong, Urumqi |
UtcP9 |
UTC+09:00, Osaka, Sapporo, Tokyo, Seoul, Yakutsk |
UtcP930 |
UTC+09:30, Adelaide, Darwin |
UtcP10 |
UTC+10:00, Canberra, Melbourne, Sydney, Guam, Hobart, Vladivostok |
UtcP11 |
UTC+11:00, Magadan, Solomon Is., New Caledonia |
UtcP12 |
UTC+12:00, Auckland, Wellington, Fiji, Kamchatka, Marshall Is. |
UtcP13 |
UTC+13:00, Nuku'alofa |
UtcP14 |
UTC+14:00, Line Islands |
Unspecified |
Unspecified Time Zone |
Tpm20SoftwareInterfaceOperation (TPM 2.0 Software Interface Operation) Member of Bios.v1_0_0.Bios
Description | TPM 2.0 Software Interface Operation: FIFO or CRB. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoAction |
No Action |
Fifo |
FIFO interface |
Crb |
CRB interface |
Tpm20SoftwareInterfaceStatus (Current TPM 2.0 Software Interface Status) Member of Bios.v1_0_0.Bios
Description | Current TPM 2.0 Software Interface Status: FIFO or CRB. |
Type | Enumeration |
Read Only | True |
Value | Description |
---|---|
NoAction |
No Action |
Fifo |
FIFO interface |
Crb |
CRB interface |
Tpm2Operation (TPM 2.0 Operation) Member of Bios.v1_0_0.Bios
Description | Use this option to perform a clear operation on the TPM. Clearing the TPM can prevent the server from booting to a TPM-aware operating system if the operating system uses TPM's measurements. TPM 2.0 is only supported in UEFI Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoAction |
No Action |
Clear |
Clear |
TpmActivePcrs (Current TPM 2.0 Active PCRs) Member of Bios.v1_0_0.Bios
Description | Current TPM 2.0 Active PCRs: SHA1, SHA256 or SHA1_SHA256 |
Type | Enumeration |
Read Only | True |
Value | Description |
---|---|
NotSpecified |
Not specified |
Sha1 |
SHA1 only |
Sha256 |
SHA256 only |
Sha1Sha256 |
SHA1 and SHA256 |
TpmChipId (Current TPM Chip ID) Member of Bios.v1_0_0.Bios
Description | Current TPM Chip: STMicro, Intel PTT fTPM or Nationz TPM20 |
Type | Enumeration |
Read Only | True |
Value | Description |
---|---|
None |
None |
StMicroGen10 |
ST Micro Gen10 |
IntelPttFTpm |
Intel PTT fTPM |
NationzTpm20 |
Nationz TPM20 |
TpmFips (Current TPM FIPS mode) Member of Bios.v1_0_0.Bios
Description | Current TPM FIPS (Federal Information Processing Standard) status: Not specified; non-FIPS certified; FIPS certified. |
Type | Enumeration |
Read Only | True |
Value | Description |
---|---|
NotSpecified |
Not specified |
NonFipsMode |
Non-FIPS Mode |
FipsMode |
FIPS mode |
TpmFipsModeSwitch (TPM FIPS Mode Switch) Member of Bios.v1_0_0.Bios
Description | Use this option to switch the TPM chip to FIPS mode, regular mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoAction |
No Action |
RegularMode |
Regular mode |
FipsMode |
FIPS mode |
TpmModeSwitchOperation (TPM Mode Switch Operation) Member of Bios.v1_0_0.Bios
Description | Use this option to switch the TPM chip to TPM 1.2/2.0, FIPS mode or non-FIPS mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoAction |
No Action |
Tpm12 |
TPM 1.2 |
Tpm20 |
TPM 2.0 |
TpmOperation (TPM 1.2 Operation) Member of Bios.v1_0_0.Bios
Description | Use this option to enable the Trusted Platform Module and BIOS secure startup. When enabled, the TPM is fully functional. When disabled, the TPM is visible; however, functionality is limited. This option also enables you to reset the TPM to factory settings, which clears any assigned passwords, keys, or ownership data. Clearing the TPM can prevent the server from booting to a TPM-aware operating system if the operating system uses TPM's measurements. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoAction |
No Action |
Enable |
Enable |
Disable |
Disable |
Clear |
Clear |
TpmState (Current TPM State) Member of Bios.v1_0_0.Bios
Description | Current TPM device state: Not Present; Present and Disabled; Present and Enabled. |
Type | Enumeration |
Read Only | True |
Value | Description |
---|---|
NotPresent |
Not Present |
PresentDisabled |
Present and Disabled |
PresentEnabled |
Present and Enabled |
TpmType (Current TPM Type) Member of Bios.v1_0_0.Bios
Description | Current TPM device type. |
Type | Enumeration |
Read Only | True |
Value | Description |
---|---|
NoTpm |
No TPM |
Tpm12 |
TPM 1.2 |
Tpm20 |
TPM 2.0 |
TpmUefiOpromMeasuring (TPM UEFI Option ROM Measurement) Member of Bios.v1_0_0.Bios
Description | Use this option to enable measuring the UEFI PCI option ROMs. Disabling this option skips measuring the UEFI PCI option ROMs. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
TpmVisibility (TPM Visibility) Member of Bios.v1_0_0.Bios
Description | Use this option to hide the TPM from the operating system. When the TPM is hidden, BIOS secure startup is disabled, and the TPM does not respond to any commands. Intended use is for removing the TPM option from the system without removing the actual hardware. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Hidden |
Hidden |
Visible |
Visible |
UefiOptimizedBoot (UEFI Optimized Boot) Member of Bios.v1_0_0.Bios
Description | When enabled, the system BIOS boots using native UEFI graphics drivers. When disabled, the system BIOS boots using INT10 legacy video support. You cannot disable this option if Secure Boot is enabled. You can only configure this option if Boot Mode is configured to UEFI Mode. |
Set this option to disabled for compatibility with Microsoft Windows 2008 and Windows 2008 R2 operating systems on a system configured for UEFI Mode. | |
Set this option to enabled for compatibility with VMWare ESXi operating systems on a system configured for UEFI Mode. | |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
UefiSerialDebugLevel (UEFI Serial Debug Message Level) Member of Bios.v1_0_0.Bios
Description | Use this option to enable the UEFI Serial Debug output and verbosity level. Selecting Verbose can impact server boot time significantly. This option is only applicable in UEFI Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
ErrorsOnly |
Errors Only |
Medium |
Medium |
Network |
Network |
Verbose |
Verbose |
Custom |
Custom |
UefiShellBootOrder (Add Embedded UEFI Shell to Boot Order) Member of Bios.v1_0_0.Bios
Description | When enabled, this option adds the Embedded UEFI Shell as an entry in the UEFI Boot Order list. This option is only available when the Boot Mode is configured to UEFI Mode and the Embedded UEFI Shell is enabled. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
UefiShellScriptVerification (Shell Script Verification) Member of Bios.v1_0_0.Bios
Description | Enable this option to allow verification of UEFI shell script files when Secure Boot is enabled. For successful execution of script, make sure that UEFI shell scripts are enrolled in the Secure Boot database (db). |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
UefiShellStartup (UEFI Shell Script Auto-Start) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable automatic execution of the Embedded UEFI Shell startup script. You can store the script file on local media or access it from a network location. You must name the script file "startup.nsh" and place it on local media or a network location accessible to the server. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
UefiShellStartupLocation (Shell Auto-Start Script Location) Member of Bios.v1_0_0.Bios
Description | Use this option to select the location of the Embedded UEFI Shell startup script. For the 'File Systems on Attached Media' option, you must name the script file "startup.nsh" and place it on a UEFI accessible local file system, such as a FAT32 partition on a USB disk or HDD. For the 'Network Location' option, the file must end with a .nsh extension, and must be placed at an HTTP/HTTPS or FTP location accessible to the system. When you select the 'Auto' option, the system attempts to retrieve the startup script from the network location first, followed by locally attached media. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
AttachedMedia |
File Systems on Attached Media |
NetworkLocation |
Network Location |
UefiShellStartupUrl (Network Location for Shell Auto-Start Script) Member of Bios.v1_0_0.Bios
Description | Use this option to configure a network URL to a UEFI Shell startup script. This option is available and used only when the Auto-Start Script Location is set to 'Network Location', or 'Auto', and the Shell Auto-Start Script discovery using DHCP is set to 'Disabled'. URLs in HTTP/HTTPS are accepted using either an IPv4 or IPv6 server address, or using a host name. FTP formats are accepted using either an IPv4 server address or a host name. For example, the URLs can be in any of the following formats: http://192.168.0.1/file/file.nsh, http://example.com/file/file.nsh, https://example.com/file/file.nsh, http://[1234::1000]/file.nsh. The file must end with an .nsh extension. When configured, the Embedded UEFI Shell attempts to load and execute the startup script from the network location pointed to by this URL. When a HTTPS URL is configured, you must enroll the respective HTTPS server's TLS certificate under Server Security > TLS(HTTPS) Options. |
Type | String |
Read Only | False |
UefiShellStartupUrlFromDhcp (Discover Shell Auto-Start Script using DHCP) Member of Bios.v1_0_0.Bios
Description | Use this option to let the Shell discover its startup script URL using DHCP. This option is available only if the 'HTTP Support' policy is not set to 'Disabled' and Auto-Start Script Location is set to 'Network Location', or 'Auto'. When set to 'Enabled', the Shell sends DHCP requests with the DHCP User Class option set to the string 'UEFIShell'. The DHCP server must be configured to provide HTTP/HTTPS or FTP URLs when this DHCP User Class string is present in the DHCP request. The User Class option is Option 77 when using DHCP over IPv4, and Option 15 when using DHCP over IPv6. URLs in HTTP/HTTPS must use either an IPv4 or IPv6 server address, or a host name. FTP formats are accepted using either an IPv4 server address or a host name. The URL provided by the DHCP server should match the 'HTTP Support' policy. When 'HTTP Support' policy is set to 'Auto', any HTTP/HTTPS or FTP URL provided by the DHCP server is used. When policy is set to 'HTTPS only', only HTTPS URLs are used, and other URLs are ignored. When policy is set to 'HTTP only', only HTTP or FTP URLs are used, and other URLs are ignored. When policy is set to 'Disabled', the Shell does not send any DHCP request. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
UncoreFreqScaling (Uncore Frequency Scaling) Member of Bios.v1_0_0.Bios
Description | This option controls the frequency scaling of the processor's internal busses (the uncore.) Setting this option to Auto enables the processor to dynamically change frequencies based on workload. Forcing to the maximum or minimum frequency enables tuning for latency or power consumption. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Maximum |
Maximum |
Minimum |
Minimum |
UpiPrefetcher (UPI Prefetcher) Member of Bios.v1_0_0.Bios
Description | Use this option to disable the processor UPI Prefetch feature. In some cases, setting this option to disabled can improve performance. Typically, setting this option to enabled provides better performance. Only disable this option after performing application benchmarking to verify improved performance in the environment. This option must be enabled when Sub-Numa Clustering (SNC) is enabled. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
UrlBootFile (Boot from URL 1) Member of Bios.v1_0_0.Bios
Description | Use this option to configure a network URL to a bootable ISO or EFI file. URLs in HTTP/HTTPS are accepted using either an IPv4 or IPv6 server address, or using a host name. For example, the URLs can be in any of the following formats: http://192.168.0.1/file/image.iso, http://example.com/file/image.efi, https://example.com/file/image.efi, http://[1234::1000]/image.iso. |
When configured, this URL is listed as a boot option in the UEFI boot menu. Selecting this boot option downloads the file to the system memory, and configures the system to attempt to boot from it. There is no specific ordering on this option. It can be independently ordered in the boot menu. | |
This setting requires configuring the 'Pre-Boot Network Interface' option if you want to access the URL location through a specific network interface. When a HTTPS URL is configured, this setting requires enrolling the respective TLS certificate of the HTTPS server under Server Security > TLS(HTTPS) Options. | |
This option does not depend on the "DHCPv4" and "IPv6 Config Policy" settings. | |
This is only applicable in UEFI Mode. | |
Note: Booting from an ISO file can involve only booting a preliminary OS environment image, such as WinPE or a mini Linux, or a complete OS install image if the OS supports the HTTP Boot feature (Old OS versions may not support this). Please check your OS documentation for the HTTP Boot feature support. | |
Type | String |
Read Only | False |
UrlBootFile2 (Boot from URL 2) Member of Bios.v1_0_0.Bios
Description | Use this option to configure a network URL to a bootable ISO or EFI file. URLs in HTTP/HTTPS are accepted using either an IPv4 or IPv6 server address, or using a host name. For example, the URLs can be in any of the following formats: http://192.168.0.1/file/image.iso, http://example.com/file/image.efi, https://example.com/file/image.efi, http://[1234::1000]/image.iso. |
When configured, this URL is listed as a boot option in the UEFI boot menu. Selecting this boot option downloads the file to the system memory, and configures the system to attempt to boot from it. There is no specific ordering on this option. It can be independently ordered in the boot menu. | |
This setting requires configuring the 'Pre-Boot Network Interface' option if you want to access the URL location through a specific network interface. When a HTTPS URL is configured, this setting requires enrolling the respective TLS certificate of the HTTPS server under Server Security > TLS(HTTPS) Options. | |
This option does not depend on the "DHCPv4" and "IPv6 Config Policy" settings. | |
This is only applicable in UEFI Mode. | |
Note: Booting from an ISO file can involve only booting a preliminary OS environment image, such as WinPE or a mini Linux, or a complete OS install image if the OS supports the HTTP Boot feature (Old OS versions may not support this). Please check your OS documentation for the HTTP Boot feature support. | |
Type | String |
Read Only | False |
UrlBootFile3 (Boot from URL 3) Member of Bios.v1_0_0.Bios
Description | Use this option to configure a network URL to a bootable ISO or EFI file. URLs in HTTP/HTTPS are accepted using either an IPv4 or IPv6 server address, or using a host name. For example, the URLs can be in any of the following formats: http://192.168.0.1/file/image.iso, http://example.com/file/image.efi, https://example.com/file/image.efi, http://[1234::1000]/image.iso. |
When configured, this URL is listed as a boot option in the UEFI boot menu. Selecting this boot option downloads the file to the system memory, and configures the system to attempt to boot from it. There is no specific ordering on this option. It can be independently ordered in the boot menu. | |
This setting requires configuring the 'Pre-Boot Network Interface' option if you want to access the URL location through a specific network interface. When a HTTPS URL is configured, this setting requires enrolling the respective TLS certificate of the HTTPS server under Server Security > TLS(HTTPS) Options. | |
This option does not depend on the "DHCPv4" and "IPv6 Config Policy" settings. | |
This is only applicable in UEFI Mode. | |
Note: Booting from an ISO file can involve only booting a preliminary OS environment image, such as WinPE or a mini Linux, or a complete OS install image if the OS supports the HTTP Boot feature (Old OS versions may not support this). Please check your OS documentation for the HTTP Boot feature support. | |
Type | String |
Read Only | False |
UrlBootFile4 (Boot from URL 4) Member of Bios.v1_0_0.Bios
Description | Use this option to configure a network URL to a bootable ISO or EFI file. URLs in HTTP/HTTPS are accepted using either an IPv4 or IPv6 server address, or using a host name. For example, the URLs can be in any of the following formats: http://192.168.0.1/file/image.iso, http://example.com/file/image.efi, https://example.com/file/image.efi, http://[1234::1000]/image.iso. |
When configured, this URL is listed as a boot option in the UEFI boot menu. Selecting this boot option downloads the file to the system memory, and configures the system to attempt to boot from it. There is no specific ordering on this option. It can be independently ordered in the boot menu. | |
This setting requires configuring the 'Pre-Boot Network Interface' option if you want to access the URL location through a specific network interface. When a HTTPS URL is configured, this setting requires enrolling the respective TLS certificate of the HTTPS server under Server Security > TLS(HTTPS) Options. | |
This option does not depend on the "DHCPv4" and "IPv6 Config Policy" settings. | |
This is only applicable in UEFI Mode. | |
Note: Booting from an ISO file can involve only booting a preliminary OS environment image, such as WinPE or a mini Linux, or a complete OS install image if the OS supports the HTTP Boot feature (Old OS versions may not support this). Please check your OS documentation for the HTTP Boot feature support. | |
Type | String |
Read Only | False |
UsbBoot (USB Boot Support) Member of Bios.v1_0_0.Bios
Description | Set this option to disabled to prevent the system from booting to any USB devices connected to the server. This includes preventing boot to virtual media devices, and the embedded SD or uSD card slot (if supported). |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
UsbControl (USB Control) Member of Bios.v1_0_0.Bios
Description | All USB Ports Enabled: Enables all USB ports and embedded devices.All USB Ports Disabled: Disables all USB ports and embedded devices.External USB Ports Disabled: Disables only external USB ports.Internal USB Ports Disabled: Disables only internal USB ports. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
UsbEnabled |
All USB Ports Enabled |
UsbDisabled |
All USB Ports Disabled |
ExternalUsbDisabled |
External USB Ports Disabled |
InternalUsbDisabled |
Internal USB Ports Disabled |
UserDefaultsState (User Defaults) Member of Bios.v1_0_0.Bios
Description | Displays whether user default settings are enabled or disabled. |
Type | Enumeration |
Read Only | True |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
UtilityLang (Utility Language) Member of Bios.v1_0_0.Bios
Description | Select this option to adjust the current language for the system. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
English |
English |
Japanese |
Japanese |
Chinese |
Chinese |
VideoOptions (Video Options) Member of Bios.v1_0_0.Bios
Description | Use this option to configure video settings in the system. When set to Add-in Video Enabled, Embedded Video Disabled, the system only displays video to the first discovered add-in video controller. When set to Both Add-in and Embedded Video Enabled, the system displays video to both the embedded and the first discovered add-in video controllers. In both modes, early system startup video is displayed to the embedded video controller. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
OptionalVideoOnly |
Add-in Video Enabled, Embedded Video Disabled |
BothVideoEnabled |
Both Add-in and Embedded Video Enabled |
VirtualInstallDisk (Virtual Install Disk) Member of Bios.v1_0_0.Bios
Description | Use this option to control the Virtual Install Disk. The Virtual Install Disk contains drivers specific to this server that an OS can use during installation. If enabled, the Virtual Install Disk appears as a drive in the operating system. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
VirtualSerialPort (Virtual Serial Port) Member of Bios.v1_0_0.Bios
Description | Use this option to assign the logical COM port address and associated default resources used by the Virtual Serial Port (VSP). VSP enables the Management Processor to present an emulated serial port to support the BIOS Serial Console and operating system serial console. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Com1Irq4 |
COM 1; IRQ4; I/O: 3F8h-3FFh |
Com2Irq3 |
COM 2; IRQ3; I/O: 2F8h-2FFh |
Disabled |
Disabled |
VlanControl (VLAN Control) Member of Bios.v1_0_0.Bios
Description | Use this option to enable or disable VLAN tagging on all enabled network interfaces. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
VlanId (VLAN ID) Member of Bios.v1_0_0.Bios
Description | Use this option to set the global VLAN ID for all enabled network interfaces. Valid values are 0 to 4094.A value of 0 sets the device to send untagged frames. |
Type | Integer |
Read Only | False |
VlanPriority (VLAN Priority) Member of Bios.v1_0_0.Bios
Description | Use this option to set the priority for the VLAN tagged frames. Valid values are 0 to 7. |
Type | Integer |
Read Only | False |
WakeOnLan (Wake-On LAN) Member of Bios.v1_0_0.Bios
Description | You can configure the server to be powered on remotely when it receives a special packet. This option requires a NIC, NIC driver, and operating system that are WOL-capable. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
WorkloadProfile (Workload Profile) Member of Bios.v1_0_0.Bios
Description | Select this option to change the Workload Profile to accommodate your desired workload. Settings that are changed by the Workload Profile are grayed out and unchangeable unless in the 'Custom' profile. Please refer to the 'UEFI Workload-based Performance Tuning Guide' for details on which profiles affect which options. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
GeneralPowerEfficientCompute |
General Power Efficient Compute |
GeneralPeakFrequencyCompute |
General Peak Frequency Compute |
GeneralThroughputCompute |
General Throughput Compute |
Virtualization-PowerEfficient |
Virtualization - Power Efficient |
Virtualization-MaxPerformance |
Virtualization - Max Performance |
LowLatency |
Low Latency |
MissionCritical |
Mission Critical |
TransactionalApplicationProcessing |
Transactional Application Processing |
HighPerformanceCompute(HPC) |
High Performance Compute (HPC) |
DecisionSupport |
Decision Support |
GraphicProcessing |
Graphic Processing |
I/OThroughput |
I/O Throughput |
Custom |
Custom |
XptPrefetcher (XPT Prefetcher) Member of Bios.v1_0_0.Bios
Description | Use this option to disable the processor XPT Prefetch feature. In some cases, setting this option to disabled can improve performance. Typically, setting this option to enabled provides better performance. Only disable this option after performing application benchmarking to verify improved performance in the environment. This option must be enabled when Sub-Numa Clustering (SNC) is enabled. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Enabled |
Enabled |
Disabled |
Disabled |
iSCSIPolicy (iSCSI Policy) Member of Bios.v1_0_0.Bios
Description | Use this option to set the iSCSI Policy. If configured to Software Initiator, the iSCSI software initiator will be used to access iSCSI targets on any configured NIC ports. If configured to Adapter Initiator, the adapter specific iSCSI initiator will be used instead. The adapter firmware must be configured to access iSCSI targets from the adapter initiator. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
SoftwareInitiator |
Software Initiator |
AdapterInitiator |
Adapter Initiator |
@odata.type: "#BootOption.v1_0_1.BootOption"
This is the schema definition for the BootOption resource. It represents the properties of a bootable device available in the System.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/bootoptions/{item} |
GET |
Member of BootOption.v1_0_1.BootOption
Description | The alias of this Boot Source. |
Type | string or null |
Read Only | True |
Member of BootOption.v1_0_1.BootOption
Description | A flag that shows if the Boot Option is enabled. |
Type | boolean or null |
Read Only | False |
Member of BootOption.v1_0_1.BootOption
Description | The unique boot option string that is referenced in the BootOrder. |
Type | string or null |
Read Only | True |
Member of BootOption.v1_0_1.BootOption
Description | The user-readable display string of the Boot Option. |
Type | string or null |
Read Only | True |
Member of BootOption.v1_0_1.BootOption
Description | The UEFI device path used to access this UEFI Boot Option. |
Type | string or null |
Read Only | True |
@odata.type: "#BootOptionCollection.BootOptionCollection"
A Collection of BootOption resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/bootoptions |
GET |
Link Name | Destination type |
---|---|
Members[] |
BootOption |
Member of BootOptionCollection.BootOptionCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of BootOptionCollection.BootOptionCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of BootOptionCollection.BootOptionCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#Certificate.v1_1_0.Certificate"
The Certificate resource describes an X509 certificate.
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/externalaccountproviders/ldap/certificates/{item} |
GET PATCH DELETE |
Member of Certificate.v1_1_0.Certificate
Description | Contains PEM formatted X509 certificate or PKCS7 certificate chain (Base64 encoded). |
Type | string |
Read Only | False |
Added | iLO 5 1.40 |
Format | text |
Member of Certificate.v1_1_0.Certificate
Type | string |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
PEM |
A PEM encoded certificate. |
PKCS7 |
A PEM encoded PKCS7 certificate. |
Member of Certificate.v1_1_0.Certificate
Description | The Certificate Authority that issued the certificate. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
Member of Certificate.v1_1_0.Certificate
Description | The serial number that the Certificate Authority assigned to the certificate. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
Member of Certificate.v1_1_0.Certificate
Description | The entity to which the certificate was issued. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
Member of Certificate.v1_1_0.Certificate
Description | The date on which the certificate validity period ends. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
Format | date-time |
Member of Certificate.v1_1_0.Certificate
Description | The date on which the certificate validity period begins. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
Format | date-time |
@odata.type: "#CertificateCollection.CertificateCollection"
A Collection of Certificate resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/externalaccountproviders/ldap/certificates |
GET POST |
Link Name | Destination type |
---|---|
Members[] |
Certificate |
Member of CertificateCollection.CertificateCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of CertificateCollection.CertificateCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of CertificateCollection.CertificateCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#Chassis.v1_6_0.Chassis"
The Chassis resource describes the physical components for a system. This object represents rack mount servers, blades, and all other containers. The non-CPU/device-centric parts of the schema are accessed either directly or indirectly through this resource.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item} |
GET POST |
Link Name | Destination type |
---|---|
Links/ComputerSystems[] |
ComputerSystem |
Links/ManagedBy[] |
Manager |
Oem/Hpe/Links/Devices |
Collection of HpeServerDevice |
NetworkAdapters |
Collection of NetworkAdapter |
Power |
Power |
Thermal |
Thermal |
Links/Drives[] |
Drive |
Member of Chassis.v1_6_0.Chassis
Description | The chassis user-assigned asset tag. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of Chassis.v1_6_0.Chassis
Description | This property indicates the physical form factor type of this resource. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Rack |
An equipment rack, typically a 19-inch wide freestanding unit. |
Blade |
An enclosed or semi-enclosed, typically vertically-oriented, system chassis that must be plugged into a multi-system chassis to function normally. |
Enclosure |
A generic term for a chassis that does not fit any other description. |
StandAlone |
A single, free-standing system, commonly called a tower or desktop chassis. |
RackMount |
A single system chassis designed specifically for mounting in an equipment rack. |
Card |
A loose device or circuit board intended to be installed in a system or other enclosure. |
Cartridge |
A small self-contained system intended to be plugged into a multi-system chassis. |
Row |
A collection of equipment racks. |
Pod |
A collection of equipment racks in a large, likely transportable, container. |
Expansion |
A chassis that expands the capabilities or capacity of another chassis. |
Sidecar |
A chassis that mechanically connects with another chassis to expand its capabilities or capacity. |
Zone |
A logical division or portion of a physical chassis that contains multiple devices or systems that cannot be physically separated. |
Sled |
TBD |
Shelf |
An enclosed or semi-enclosed, typically horizontally-oriented, system chassis that must be plugged into a multi-system chassis to function normally. |
Other |
A chassis that does not fit any of these definitions. |
Member of Chassis.v1_6_0.Chassis
Description | The chassis indicator LED that is used to identify the chassis. The user can manipulate this LED. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Unknown |
The state of the Indicator LED cannot be determined. |
Lit |
The Indicator LED is on. |
Blinking |
The Indicator LED is blinking. |
Off |
The Indicator LED is off. |
Member of Chassis.v1_6_0.Chassis
Description | The chassis manufacturer. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Chassis.v1_6_0.Chassis
Description | The chassis model number. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The collection of network adapters contained within this chassis.
NetworkAdapters is a link ("@odata.id": URI
) to another resource.
Member of Chassis.v1_6_0.Chassis
Description | The bay number of the node or the blade. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of Chassis.v1_6_0.Chassis
Description | The number of enclosure bays this chassis consumes in height. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of Chassis.v1_6_0.Chassis
Description | The number of enclosure bays this chassis consumes in width. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of Chassis.v1_6_0.Chassis
Description | The CPLD version of the enclosure. |
Type | string |
Read Only | True |
Member of Chassis.v1_6_0.Chassis
Description | The enclosure indicator LED that is used to identify the enclosure. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Unknown |
The state of the Indicator LED cannot be determined. |
Lit |
The Indicator LED is on. |
Blinking |
The Indicator LED is blinking. |
Off |
The Indicator LED is off. |
Member of Chassis.v1_6_0.Chassis
Description | Type of enclosure. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
Member of Chassis.v1_6_0.Chassis
Description | The UUID of the enclosure. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
Oem.Hpe.Firmware.PlatformDefinitionTable Oem.Hpe.Firmware.PlatformDefinitionTable.Current Oem.Hpe.Firmware.PlatformDefinitionTable.Current.VersionString Member of Chassis.v1_6_0.Chassis
Description | The version of the Intelligent Platform Abstraction Data. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.PowerManagementController Oem.Hpe.Firmware.PowerManagementController.Current Oem.Hpe.Firmware.PowerManagementController.Current.VersionString Member of Chassis.v1_6_0.Chassis
Description | The firmware version of the Power Monitor. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.PowerManagementControllerBootloader Oem.Hpe.Firmware.PowerManagementControllerBootloader.Current Oem.Hpe.Firmware.PowerManagementControllerBootloader.Current.Family Member of Chassis.v1_6_0.Chassis
Description | The family type of the Power Monitor hardware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.PowerManagementControllerBootloader.Current.VersionString Member of Chassis.v1_6_0.Chassis
Description | The firmware version of the Power Monitor boot loader. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.SASProgrammableLogicDevice Oem.Hpe.Firmware.SASProgrammableLogicDevice.Current Oem.Hpe.Firmware.SASProgrammableLogicDevice.Current.VersionString Member of Chassis.v1_6_0.Chassis
Description | The firmware version of the SAS controller. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.SPSFirmwareVersionData Oem.Hpe.Firmware.SPSFirmwareVersionData.Current Oem.Hpe.Firmware.SPSFirmwareVersionData.Current.VersionString Member of Chassis.v1_6_0.Chassis
Description | The SPS FW Version number, aka ME FW Version, AAAA.BBBB.CCCC.DDDD.E |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.SystemProgrammableLogicDevice Oem.Hpe.Firmware.SystemProgrammableLogicDevice.Current Oem.Hpe.Firmware.SystemProgrammableLogicDevice.Current.VersionString Member of Chassis.v1_6_0.Chassis
Description | The firmware version of the CPLD. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Images.Front Oem.Hpe.Images.Front.extref Member of Chassis.v1_6_0.Chassis
Description | The URI of an external resource. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | uri-reference |
Oem.Hpe.Images.Model Oem.Hpe.Images.Model.extref Member of Chassis.v1_6_0.Chassis
Description | The URI of an external resource. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | uri-reference |
Oem.Hpe.Location.GeographicLocation Oem.Hpe.Location.GeographicLocation.RackName Member of Chassis.v1_6_0.Chassis
Description | The name of the chassis enclosure. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Location.LocationInRack Oem.Hpe.Location.LocationInRack.RackLdsPartNumber Member of Chassis.v1_6_0.Chassis
Description | The chassis rack part number. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Location.LocationInRack.RackLdsProductDescription Member of Chassis.v1_6_0.Chassis
Description | The chassis rack product description. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Location.LocationInRack.RackUHeight Member of Chassis.v1_6_0.Chassis
Description | The chassis rack U height. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Location.LocationInRack.RackUUID Member of Chassis.v1_6_0.Chassis
Description | The chassis rack UUID. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Location.LocationInRack.TagVersion Member of Chassis.v1_6_0.Chassis
Description | The chassis rack tag version. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Location.LocationInRack.ULocation Member of Chassis.v1_6_0.Chassis
Description | The chassis rack U location. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Location.LocationInRack.UPosition Member of Chassis.v1_6_0.Chassis
Description | The chassis U position in the rack. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Location.LocationOfChassis Oem.Hpe.Location.LocationOfChassis.UUID Member of Chassis.v1_6_0.Chassis
Description | The chassis UUID provided by SMBIOS. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of Chassis.v1_6_0.Chassis
Description | Indicates if MCTP is enabled on the server or not. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
Oem.Hpe.OnboardAdministrator.IPv4Address Member of Chassis.v1_6_0.Chassis
Description | IPv4 address of the chassis. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Oem.Hpe.OnboardAdministrator.IPv6
Oem.Hpe.OnboardAdministrator.IPv6.DHCPv6Address (array)
Member of Chassis.v1_6_0.Chassis
DHCPv6Address
is an array containing elements of:
Type | string |
Read Only | True |
Format | ipv6 |
Oem.Hpe.OnboardAdministrator.IPv6.SLAACAddress (array)
Member of Chassis.v1_6_0.Chassis
SLAACAddress
is an array containing elements of:
Type | string |
Read Only | True |
Format | ipv6 |
Oem.Hpe.OnboardAdministrator.IPv6.StaticAddress (array)
Member of Chassis.v1_6_0.Chassis
StaticAddress
is an array containing elements of:
Type | string |
Read Only | True |
Format | ipv6 |
Oem.Hpe.OnboardAdministrator.MacAddress Member of Chassis.v1_6_0.Chassis
Description | MAC address of the chassis. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Oem.Hpe.PowerAlertMode.Activated Member of Chassis.v1_6_0.Chassis
Description | The power alert mode activation state. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.PowerAlertMode.AlertPowerWatts Member of Chassis.v1_6_0.Chassis
Description | The power consumption of the system when operating in alert mode. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of Chassis.v1_6_0.Chassis
Description | The name of the rack that contains the enclosure. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
Member of Chassis.v1_6_0.Chassis
SmartStorageBattery
is an array containing elements of:
SmartStorageBattery[{item}].BatteryWearLevelPercent Member of Chassis.v1_6_0.Chassis
Description | The battery wear level percentage. When this value reaches 100%, the battery is completely worn out and needs to be replaced. The value is null if battery wear level cannot be determined or is not supported. |
Type | integer or null |
Read Only | True |
SmartStorageBattery[{item}].ChargeLevelPercent Member of Chassis.v1_6_0.Chassis
Description | State of charge of the battery. |
Type | integer or null |
Read Only | True |
SmartStorageBattery[{item}].ErrorCode Member of Chassis.v1_6_0.Chassis
Description | Error code of the battery. |
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
GeneralFailure |
The battery has failed. |
HighInternalBatteryResistance |
The battery has failed due to high internal resistance. |
LowOpenCircuitVoltage |
The battery has failed due to a low voltage output. |
BatteryCellFailure |
The battery has failed. |
BatteryChargeTimeout |
The battery did not charge at the expected rate, indicating a faulty battery. |
OverTemperature |
The battery was disabled due to high ambient temperature, and will be re-enabled when the temperature is lowered. |
DischargeBelowMinimumVoltage |
The battery discharged below the minimum discharge voltage, and may be re-enabled upon recharging the battery. |
DischargeCurrentHigh |
The last backup failed due to exceeding the maximum discharge current. |
LoadCountExceeded |
The battery was disabled due to exceeding the maximum amount of devices supported, and will be re-enabled when the battery has been recharged or the additional devices are removed. |
BackupSucceeded |
The last backup succeeded within the expected time. |
OverCurrent |
The battery has been protected due to exceeding the output current capability. The battery should be re-enabled on the next reboot. |
PermanentFailure |
The battery has permanently failed. |
BackupTimeExceeded |
The last backup failed due to exceeding the battery discharge time limit. |
SmartStorageBattery[{item}].FailurePredicted Member of Chassis.v1_6_0.Chassis
Description | Is this battery currently predicting a failure in the near future. |
Type | boolean or null |
Read Only | True |
SmartStorageBattery[{item}].FirmwareVersion Member of Chassis.v1_6_0.Chassis
Description | Firmware version of the battery. |
Type | string |
Read Only | True |
SmartStorageBattery[{item}].Index Member of Chassis.v1_6_0.Chassis
Description | Index of the battery. |
Type | integer |
Read Only | True |
SmartStorageBattery[{item}].MaximumCapWatts Member of Chassis.v1_6_0.Chassis
Description | Maximum capacity of the battery in watts. |
Type | integer |
Read Only | True |
SmartStorageBattery[{item}].Model Member of Chassis.v1_6_0.Chassis
Description | Model of the battery. |
Type | string |
Read Only | True |
SmartStorageBattery[{item}].ProductName Member of Chassis.v1_6_0.Chassis
Description | Product name of the battery. |
Type | string |
Read Only | True |
SmartStorageBattery[{item}].RemainingChargeTimeSeconds Member of Chassis.v1_6_0.Chassis
Description | Remaining charging time of the battery in seconds. |
Type | integer or null |
Read Only | True |
SmartStorageBattery[{item}].SerialNumber Member of Chassis.v1_6_0.Chassis
Description | Serial number of the battery. |
Type | string |
Read Only | True |
SmartStorageBattery[{item}].SparePartNumber Member of Chassis.v1_6_0.Chassis
Description | Spare part number of the battery. |
Type | string |
Read Only | True |
SmartStorageBattery[{item}].Status Member of Chassis.v1_6_0.Chassis See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.SystemMaintenanceSwitches.Sw1 Member of Chassis.v1_6_0.Chassis
Description | Override iLO security. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
On |
iLO Security Override Enabled. |
Off |
No function (Normal). |
Oem.Hpe.SystemMaintenanceSwitches.Sw10 Member of Chassis.v1_6_0.Chassis
Description | Reserved. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
On |
Switch is on. |
Off |
Switch is off (Normal). |
Oem.Hpe.SystemMaintenanceSwitches.Sw11 Member of Chassis.v1_6_0.Chassis
Description | Reserved. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
On |
Switch is on. |
Off |
Switch is off (Normal). |
Oem.Hpe.SystemMaintenanceSwitches.Sw12 Member of Chassis.v1_6_0.Chassis
Description | Reserved. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
On |
Switch is on. |
Off |
Switch is off (Normal). |
Oem.Hpe.SystemMaintenanceSwitches.Sw2 Member of Chassis.v1_6_0.Chassis
Description | Reserved. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
On |
Switch is on. |
Off |
Switch is off (Normal). |
Oem.Hpe.SystemMaintenanceSwitches.Sw3 Member of Chassis.v1_6_0.Chassis
Description | Reserved. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
On |
Switch is on. |
Off |
Switch is off (Normal). |
Oem.Hpe.SystemMaintenanceSwitches.Sw4 Member of Chassis.v1_6_0.Chassis
Description | Reserved. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
On |
Switch is on. |
Off |
Switch is off (Normal). |
Oem.Hpe.SystemMaintenanceSwitches.Sw5 Member of Chassis.v1_6_0.Chassis
Description | BIOS/UEFI Password Disable. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
On |
Power On Password disabled. |
Off |
Power On Password enabled (Normal). |
Oem.Hpe.SystemMaintenanceSwitches.Sw6 Member of Chassis.v1_6_0.Chassis
Description | Reset Configuration. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
On |
|
Off |
Oem.Hpe.SystemMaintenanceSwitches.Sw7 Member of Chassis.v1_6_0.Chassis
Description | Reserved. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
On |
Switch is on. |
Off |
Switch is off (Default). |
Oem.Hpe.SystemMaintenanceSwitches.Sw8 Member of Chassis.v1_6_0.Chassis
Description | Reserved. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
On |
Switch is on. |
Off |
Switch is off (Default). |
Oem.Hpe.SystemMaintenanceSwitches.Sw9 Member of Chassis.v1_6_0.Chassis
Description | Reserved. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
On |
Switch is on. |
Off |
Switch is off (Default). |
Member of Chassis.v1_6_0.Chassis
Description | Tray ID is a platform dependent value used to identify what kind of server tray it is. |
Type | string |
Read Only | True |
Member of Chassis.v1_6_0.Chassis
Description | The chassis part number. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
PhysicalSecurity.IntrusionSensor Member of Chassis.v1_6_0.Chassis
Description | This indicates the known state of the physical security sensor, such as if it is hardware intrusion detected. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Normal |
No abnormal physical security conditions are detected at this time. |
HardwareIntrusion |
A door, lock, or other mechanism protecting the internal system hardware from being accessed is detected as being in an insecure state. |
TamperingDetected |
Physical tampering of the monitored entity is detected. |
PhysicalSecurity.IntrusionSensorReArm Member of Chassis.v1_6_0.Chassis
Description | This indicates how the Normal state to be restored. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Manual |
This sensor would be restored to the Normal state by a manual re-arm. |
Automatic |
This sensor would be restored to the Normal state automatically as no abnormal physical security conditions are detected. |
A reference to the thermal metrics (power supplies, power policies, sensors) for this chassis.
Power is a link ("@odata.id": URI
) to another resource.
Member of Chassis.v1_6_0.Chassis
Description | This is the current power state of the chassis. |
Type | string or null |
Read Only | True |
The following are the supported values:
Value |
---|
Null |
On |
Off |
Unknown |
Reset |
Member of Chassis.v1_6_0.Chassis
Description | The chassis SKU. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Chassis.v1_6_0.Chassis
Description | The chassis serial number. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Chassis.v1_6_0.Chassis See the Redfish standard schema and specification for information on common Status object.
A reference to the thermal metrics (fans, cooling, sensors) for this chassis.
Thermal is a link ("@odata.id": URI
) to another resource.
HpeServerChassis.DisableMCTPOnServer Member of Chassis.v1_6_0.Chassis There are no parameters for this action.
HpeServerChassis.FactoryResetMCTP Member of Chassis.v1_6_0.Chassis There are no parameters for this action.
HpeServerChassis.ModifyEnclosureChassisFru Member of Chassis.v1_6_0.Chassis The action to modify field of enclosure chassis FRU.
Parameters:
PartNumber (string)
Part Number of the enclosure chassis.
SerialNumber (string)
Serial Number of the enclosure chassis.
@odata.type: "#ChassisCollection.ChassisCollection"
A Collection of Chassis resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis |
GET |
Link Name | Destination type |
---|---|
Members[] |
Chassis |
Member of ChassisCollection.ChassisCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of ChassisCollection.ChassisCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of ChassisCollection.ChassisCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#ComputerSystem.v1_4_0.ComputerSystem"
The ComputerSystem resource describes the compute node and its properties. A ComputerSystem represents a physical or virtual machine and the local resources, such as memory, CPU, and other devices that can be accessed from that machine.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item} |
GET POST PATCH |
Link Name | Destination type |
---|---|
EthernetInterfaces |
Collection of EthernetInterface |
Oem/Hpe/Links/USBDevices |
Collection of HpeUSBDevice |
Links/Chassis[] |
Chassis |
Memory |
Collection of Memory |
Oem/Hpe/Links/USBPorts |
Collection of HpeUSBPort |
Oem/Hpe/Links/NetworkAdapters |
Collection of HpeBaseNetworkAdapter |
Oem/Hpe/SmartStorageConfig[] |
SmartStorageConfig |
Processors |
Collection of Processor |
SecureBoot |
SecureBoot |
Storage |
Collection of Storage |
Bios |
Bios |
Oem/Hpe/Links/EthernetInterfaces |
Collection of EthernetInterface |
LogServices |
Collection of LogService |
Oem/Hpe/Links/SmartStorage |
HpeSmartStorage |
Oem/Hpe/Links/PCISlots |
Collection of HpeServerPCISlot |
NetworkInterfaces |
Collection of NetworkInterface |
Links/ManagedBy[] |
Manager |
Oem/Hpe/Links/PCIDevices |
Collection of HpeServerPciDevice |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | A user-definable tag that is used to track this system for inventory or other client purposes. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
The Bios URI.
Bios is a link ("@odata.id": URI
) to another resource.
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The version of the system BIOS or primary system firmware. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Boot.BootOptions
A reference to the collection of the UEFI Boot Options associated with this Computer System.
BootOptions is a link ("@odata.id": URI
) to another resource.
Boot.BootOrder (array)
Member of ComputerSystem.v1_4_0.ComputerSystem
BootOrder
is an array containing elements of:
Type | string or null |
Read Only | True |
Boot.BootSourceOverrideEnabled Member of ComputerSystem.v1_4_0.ComputerSystem
Description | BootSourceOverrideTarget must be specified before BootSourceOverrideEnabled can be used. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Disabled |
The system will boot normally. |
Once |
On its next boot cycle, the system will boot (one time) to the Boot Source Override Target. The value of BootSourceOverrideEnabled is then reset back to Disabled. |
Continuous |
The system will boot to the target specified in the BootSourceOverrideTarget until this property is set to Disabled. |
Boot.BootSourceOverrideMode Member of ComputerSystem.v1_4_0.ComputerSystem
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Legacy |
The system will boot in non-UEFI boot mode to the Boot Source Override Target. |
UEFI |
The system will boot in UEFI boot mode to the Boot Source Override Target. |
Boot.BootSourceOverrideTarget Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The current boot source to be used at next boot instead of the normal boot device, if BootSourceOverrideEnabled is true. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
Boot.BootSourceOverrideTarget@Redfish.AllowableValues (array)
Member of ComputerSystem.v1_4_0.ComputerSystem
BootSourceOverrideTarget@Redfish.AllowableValues
is an array containing elements of:
Description | The current boot source to be used at next boot instead of the normal boot device, if BootSourceOverrideEnabled is not Disabled. |
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
None |
Boot from the normal boot device. |
Pxe |
Boot from the Pre-Boot EXecution (PXE) environment. |
Floppy |
Boot from the floppy disk drive. |
Cd |
Boot from the CD/DVD disc. |
Usb |
Boot from a USB device as specified by the system BIOS. |
Hdd |
Boot from a hard drive. |
BiosSetup |
Boot to the BIOS Setup Utility. |
Utilities |
Boot the manufacturer's Utilities program(s). |
Diags |
Boot the manufacturer's Diagnostics program. |
UefiShell |
Boot to the UEFI Shell. |
UefiTarget |
Boot to the UEFI Device specified in the UefiTargetBootSourceOverride property. |
SDCard |
Boot from an SD Card |
UefiHttp |
Boot from a UEFI HTTP network location |
Boot.UefiTargetBootSourceOverride Member of ComputerSystem.v1_4_0.ComputerSystem
Description | This property is the UEFI Device Path of the device to boot from when BootSourceOverrideTarget is UefiTarget. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
Boot.UefiTargetBootSourceOverride@Redfish.AllowableValues (array)
Member of ComputerSystem.v1_4_0.ComputerSystem
UefiTargetBootSourceOverride@Redfish.AllowableValues
is an array containing elements of:
Description | An array of structured boot strings. |
Type | string or null |
Read Only | True |
A reference to the collection of Ethernet interfaces associated with this system.
EthernetInterfaces is a link ("@odata.id": URI
) to another resource.
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The DNS Host Name, without any domain information |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The state of the indicator LED. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Unknown |
The state of the Indicator LED cannot be determined. |
Lit |
The Indicator LED is lit. |
Blinking |
The Indicator LED is blinking. |
Off |
The Indicator LED is off. |
The LogService collection URI for this resource.
LogServices is a link ("@odata.id": URI
) to another resource.
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The manufacturer or OEM of this system. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The central memory in the system.
Memory is a link ("@odata.id": URI
) to another resource.
A reference to the collection of Memory Domains associated with this system.
MemoryDomains is a link ("@odata.id": URI
) to another resource.
MemorySummary.Status Member of ComputerSystem.v1_4_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
MemorySummary.TotalSystemMemoryGiB Member of ComputerSystem.v1_4_0.ComputerSystem
Description | This is the total amount of memory in the system measured in GiB. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
MemorySummary.TotalSystemPersistentMemoryGiB Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The total configured, system-accessible persistent memory, measured in GiB. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The model information that the manufacturer uses to refer to this system. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The collection of network interfaces partitioned to this system.
NetworkInterfaces is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.AggregateHealthStatus.AgentlessManagementService Member of ComputerSystem.v1_4_0.ComputerSystem
Description | This indicates if the Agentless Management Service is available or not. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Unavailable |
The Agentless Management Service is unavailable. |
Ready |
The Agentless Management Service is Ready. |
Oem.Hpe.AggregateHealthStatus.BiosOrHardwareHealth Oem.Hpe.AggregateHealthStatus.BiosOrHardwareHealth.Status Member of ComputerSystem.v1_4_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.AggregateHealthStatus.FanRedundancy Member of ComputerSystem.v1_4_0.ComputerSystem
Description | This indicates if the Fan is redundant or not. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Redundant |
The fans are Redundant. |
NonRedundant |
The fans are not Redundant. |
FailedRedundant |
The Redundant fan has failed. |
Unknown |
The Redundant state is unknown. |
Oem.Hpe.AggregateHealthStatus.Fans Oem.Hpe.AggregateHealthStatus.Fans.Status Member of ComputerSystem.v1_4_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.AggregateHealthStatus.Memory Oem.Hpe.AggregateHealthStatus.Memory.Status Member of ComputerSystem.v1_4_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.AggregateHealthStatus.Network Oem.Hpe.AggregateHealthStatus.Network.Status Member of ComputerSystem.v1_4_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.AggregateHealthStatus.PowerSupplies Oem.Hpe.AggregateHealthStatus.PowerSupplies.PowerSuppliesMismatch Member of ComputerSystem.v1_4_0.ComputerSystem
Description | This indicates if the there is a mismatch in the power supplies. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.AggregateHealthStatus.PowerSupplies.Status Member of ComputerSystem.v1_4_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.AggregateHealthStatus.PowerSupplyRedundancy Member of ComputerSystem.v1_4_0.ComputerSystem
Description | This indicates if the Power Supply is redundant or not. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Redundant |
The power supplies are Redundant. |
NonRedundant |
The power supplies are not Redundant. |
FailedRedundant |
The Redundant power supply has failed. |
Unknown |
The Redundant state is unknown. |
Oem.Hpe.AggregateHealthStatus.Processors Oem.Hpe.AggregateHealthStatus.Processors.Status Member of ComputerSystem.v1_4_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.AggregateHealthStatus.SmartStorageBattery Oem.Hpe.AggregateHealthStatus.SmartStorageBattery.Status Member of ComputerSystem.v1_4_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.AggregateHealthStatus.Storage Oem.Hpe.AggregateHealthStatus.Storage.Status Member of ComputerSystem.v1_4_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.AggregateHealthStatus.Temperatures Oem.Hpe.AggregateHealthStatus.Temperatures.Status Member of ComputerSystem.v1_4_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.Bios.Backup Oem.Hpe.Bios.Backup.BuildNumber Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The build number of the firmware. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Backup.BuildNumberString Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The string version of the build number of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Backup.Date Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The build date of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Backup.DebugBuild Member of ComputerSystem.v1_4_0.ComputerSystem
Description | True if the firmware is a debug build; False if it is not. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Backup.Family Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The family of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Backup.MajorVersion Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The major version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Backup.MinorVersion Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The minor version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Backup.Time Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The build time of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Backup.VersionString Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The version string of the firmware. This value might be null if VersionString is unavailable. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Bootblock Oem.Hpe.Bios.Bootblock.BuildNumber Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The build number of the firmware. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Bootblock.BuildNumberString Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The string version of the build number of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Bootblock.Date Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The build date of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Bootblock.DebugBuild Member of ComputerSystem.v1_4_0.ComputerSystem
Description | True if the firmware is a debug build; False if it is not. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Bootblock.Family Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The family of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Bootblock.MajorVersion Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The major version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Bootblock.MinorVersion Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The minor version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Bootblock.Time Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The build time of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Bootblock.VersionString Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The version string of the firmware. This value might be null if VersionString is unavailable. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Current Oem.Hpe.Bios.Current.BuildNumber Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The build number of the firmware. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Current.BuildNumberString Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The string version of the build number of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Current.Date Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The build date of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Current.DebugBuild Member of ComputerSystem.v1_4_0.ComputerSystem
Description | True if the firmware is a debug build; False if it is not. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Current.Family Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The family of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Current.MajorVersion Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The major version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Current.MinorVersion Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The minor version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Current.Time Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The build time of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.Current.VersionString Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The version string of the firmware. This value might be null if VersionString is unavailable. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Bios.UefiClass Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The UEFI BIOS Class value defined in the UEFI specification. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Null |
1 |
2 |
3 |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Displays the amount of time(in seconds) that has passed since the server was last powered on. The data is reset on iLO reset. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.15 |
Oem.Hpe.DeviceDiscoveryComplete.AMSDeviceDiscovery Member of ComputerSystem.v1_4_0.ComputerSystem
Description | This property indicates the current AMS Device Discovery Status. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Busy |
The server has AMS loaded and iLO is discovering devices that require AMS to be loaded |
Complete |
The server has AMS loaded and iLO is finished discovering devices that require AMS to be loaded |
NoAMS |
The server does not have AMS loaded for device discovery. |
Initial |
Default state after iLO has booted. |
Oem.Hpe.DeviceDiscoveryComplete.DeviceDiscovery Member of ComputerSystem.v1_4_0.ComputerSystem
Description | This property indicates the current device discovery status of devices that are not Smart Array or AMS related. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Busy |
iLO is discovering devices. |
vAuxDeviceDiscoveryComplete |
The server is off and iLO is finished discovering devices. |
vMainDeviceDiscoveryComplete |
The server is on and iLO is finished discovering devices. |
DataIncomplete |
iLO response took longer than expected while discovering devices. |
Initial |
Default state after iLO has booted. |
Oem.Hpe.DeviceDiscoveryComplete.SmartArrayDiscovery Member of ComputerSystem.v1_4_0.ComputerSystem
Description | This property indicates the current Smart Array Storage Device Discovery Status |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Busy |
iLO is discovering Smart Array devices. If the server is shutdown before discovery is complete, this reflects an incomplete data set. |
PendingSoftwareRAID |
Pending discovery of Dynamic Smart Array. |
Complete |
iLO is finished discovering Smart Array storage. |
Initial |
Default state for Smart Array |
Cached |
Data is cached, server is offline or data not yet available. |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Reports the time elapsed since the erase started |
Type | integer |
Read Only | True |
Added | iLO 5 1.40 |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Supported on UEFI based systems only. The number of seconds to delay before finalizing POST with the Mode action (e.g. delay before shutdown). If > 255 seconds is requested, the value is rounded up to the nearest minute. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Reports the guestimate time (in minutes) for the overall erase process |
Type | integer |
Read Only | True |
Added | iLO 5 1.40 |
Oem.Hpe.HostOS.OsName Member of ComputerSystem.v1_4_0.ComputerSystem
Description | from cpqHoName if AMS is running |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.HostOS.OsSysDescription Member of ComputerSystem.v1_4_0.ComputerSystem
Description | from cpqHosysDesc if AMS is running |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.HostOS.OsType Member of ComputerSystem.v1_4_0.ComputerSystem
Description | from cpqHoOsType if AMS is running. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.HostOS.OsVersion Member of ComputerSystem.v1_4_0.ComputerSystem
Description | from cpqHoVersion if AMS is running |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Always on Intelligent Provisioning is available. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Index in the Firmware Version Table for Intelligent Provisioning. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Location string of Intelligent Provisioning in Firmware Version Table. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Intelligent Provisioning Version. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Indicates if the system is cold booting. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.30 |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The PCA part number. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The PCA serial number. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Displays the last known POST Discovery Complete time |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The manner in which the system will operate during the discovery section of POST. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Auto |
BIOS will automatically use ForceFastBoot if the system hardware has not changed from last time of FullDiscovery or ForceFullDiscovery if the system hardware has changed. |
ForceFullDiscovery |
Server makes a full discovery of all devices. |
ForceFastBoot |
Server uses the existing cached discovery data. |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The manner in which the system will operate during and at completion of POST. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Normal |
Normal operations. |
PostToShutdown |
Server boots until Discovery Completes, then shuts down. |
PostToReboot |
Server boots until Discovery Completes, then reboots. |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The current state of system POST. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Unknown |
iLO was unable to determine the current server state. |
Reset |
The server is currently in reset. |
PowerOff |
The server power is off. |
InPost |
The server is booting and has not reached discovery complete. |
InPostDiscoveryComplete |
The server has reached discovery complete and is now waiting for the installed OS to be booted. Discovery complete is the point at which it has been deemed safe to read and write the BIOS configuration information. |
FinishedPost |
The server has booted the installed OS. |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The total amount of power allocated to the system. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Auto Power-On mode defines what occurs when the AC power is applied to the system. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
RemainOff |
PowerOn |
Restore |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The PowerAutoOn policy delay that can also be found in the HpBios::PowerOnDelay object. Will be null if PowerAutoOn is set to RemainOff. Blades only support Minimum and RandomUpTo120Sec. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Null |
Minimum |
15Sec |
30Sec |
45Sec |
60Sec |
RandomUpTo120Sec |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The number of lifetime minutes that the server has been powered on. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.15 |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Power Regulator mode. Switching to and from OS Control mode requires a server reboot to take effect. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
OSControl |
Dynamic |
Max |
Min |
Unknown |
Member of ComputerSystem.v1_4_0.ComputerSystem
PowerRegulatorModesSupported
is an array containing elements of:
Type | string |
Read Only | True |
Oem.Hpe.ProcessorJitterControl.ConfiguredFrequencyLimitMHz Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Displays the last known user configured frequency limit of the processor in MHz. |
Type | integer |
Read Only | True |
Added | iLO 5 1.30 |
Oem.Hpe.ProcessorJitterControl.FrequencyLimitMHz Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Current frequency limit of the processor in MHz. |
Type | integer |
Read Only | False |
Added | iLO 5 1.15 |
Oem.Hpe.ProcessorJitterControl.Mode Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Provides various jitter control modes. |
Type | string |
Read Only | False |
Added | iLO 5 1.15 |
The following are the supported values:
Value |
---|
Auto |
Disabled |
Manual |
Oem.Hpe.ProcessorJitterControl.ProcessorJitterControlOptimization Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Provides Jitter Control Optimizations. |
Type | string |
Read Only | False |
Added | iLO 5 1.30 |
The following are the supported values:
Value | Description |
---|---|
OptimizedForThroughput |
|
OptimizedForLatency |
|
ZeroLatency |
Oem.Hpe.SMBIOS.extref Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The URI of an external resource. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | uri-reference |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The IP address or FQDN of the server. Host software like AMS is required to obtain this value from the OS. |
Type | string |
Read Only | False |
Added | iLO 5 1.20 |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Indicates the current state of server Intelligent Diagnostics mode. |
Type | boolean |
Read Only | True |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Indicates the current state of server Safe Mode. |
Type | boolean |
Read Only | True |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The CRC32 of: All Device Signatures combined together, Server Slot Location in Enclosure, Enclosure UUID, and Manager Domain IP Address |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The current state of Server Signature. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Initial |
The server signature calculation has not run yet. |
Busy |
The server signature calculation is being run. |
Invalid |
The server signature is invalid. Re-compute action necessary. |
Complete |
The server signature calculation is complete and valid. |
Member of ComputerSystem.v1_4_0.ComputerSystem
SmartStorageConfig
is an array containing elements of:
SmartStorageConfig[{item}].@odata.id Member of ComputerSystem.v1_4_0.ComputerSystem
Type | string |
Read Only | True |
Format | uri-reference |
Oem.Hpe.SystemROMAndiLOEraseComponentStatus.BIOSSettingsEraseStatus Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Indicates the erase status of the individual components |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Idle |
Indicates SecureSystem Erase is not started |
Initiated |
Indicates Secure System Erase process is started |
InProgress |
Indicates Secure System Erase process is under progress |
CompletedWithSuccess |
Indicates Secure System Erase process has been completed with no errors |
CompletedWithErrors |
Indicates Secure System Erase process has been completed with some errors |
Failed |
Indicates Secure System Erase process has failed |
Oem.Hpe.SystemROMAndiLOEraseComponentStatus.iLOSettingsEraseStatus Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Indicates the erase status of the individual components |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Idle |
Indicates SecureSystem Erase is not started |
Initiated |
Indicates Secure System Erase process is started |
InProgress |
Indicates Secure System Erase process is under progress |
CompletedWithSuccess |
Indicates Secure System Erase process has been completed with no errors |
CompletedWithErrors |
Indicates Secure System Erase process has been completed with some errors |
Failed |
Indicates Secure System Erase process has failed |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Indicates the erase status of the individual components |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Idle |
Indicates SecureSystem Erase is not started |
Initiated |
Indicates Secure System Erase process is started |
InProgress |
Indicates Secure System Erase process is under progress |
CompletedWithSuccess |
Indicates Secure System Erase process has been completed with no errors |
CompletedWithErrors |
Indicates Secure System Erase process has been completed with some errors |
Failed |
Indicates Secure System Erase process has failed |
Oem.Hpe.SystemUsage.AvgCPU0Freq Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Current CPU0 average frequency in MHz. |
Type | integer |
Read Only | True |
Added | iLO 5 1.40 |
Oem.Hpe.SystemUsage.AvgCPU1Freq Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Current CPU1 average frequency in MHz. |
Type | integer |
Read Only | True |
Added | iLO 5 1.40 |
Oem.Hpe.SystemUsage.AvgCPU2Freq Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Current CPU2 average frequency in MHz. |
Type | integer |
Read Only | True |
Added | iLO 5 1.40 |
Oem.Hpe.SystemUsage.AvgCPU3Freq Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Current CPU3 average frequency in MHz. |
Type | integer |
Read Only | True |
Added | iLO 5 1.40 |
Oem.Hpe.SystemUsage.CPU0Power Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Current power consumed by the system CPU0 in Watts. |
Type | integer |
Read Only | True |
Added | iLO 5 1.40 |
Oem.Hpe.SystemUsage.CPU1Power Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Current power consumed by the system CPU1 in Watts. |
Type | integer |
Read Only | True |
Added | iLO 5 1.40 |
Oem.Hpe.SystemUsage.CPU2Power Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Current power consumed by the system CPU2 in Watts. |
Type | integer |
Read Only | True |
Added | iLO 5 1.40 |
Oem.Hpe.SystemUsage.CPU3Power Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Current power consumed by the system CPU3 in Watts. |
Type | integer |
Read Only | True |
Added | iLO 5 1.40 |
Oem.Hpe.SystemUsage.CPUICUtil Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Current System CPU Interconnect utilization in percentage |
Type | integer |
Read Only | True |
Added | iLO 5 1.40 |
Oem.Hpe.SystemUsage.CPUUtil Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Current System CPU utilization in percentage |
Type | integer |
Read Only | True |
Added | iLO 5 1.40 |
Oem.Hpe.SystemUsage.IOBusUtil Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Current System I/O bus utilization in percentage |
Type | integer |
Read Only | True |
Added | iLO 5 1.40 |
Oem.Hpe.SystemUsage.JitterCount Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Current processor Jitter Count. |
Type | integer |
Read Only | True |
Added | iLO 5 1.40 |
Oem.Hpe.SystemUsage.MemoryBusUtil Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Current System memory bus utilization in percentage |
Type | integer |
Read Only | True |
Added | iLO 5 1.40 |
Oem.Hpe.UserDataEraseComponentStatus.NVDIMMEraseStatus Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Indicates the erase status of the individual components |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Idle |
Indicates SecureSystem Erase is not started |
Initiated |
Indicates Secure System Erase process is started |
InProgress |
Indicates Secure System Erase process is under progress |
CompletedWithSuccess |
Indicates Secure System Erase process has been completed with no errors |
CompletedWithErrors |
Indicates Secure System Erase process has been completed with some errors |
Failed |
Indicates Secure System Erase process has failed |
Oem.Hpe.UserDataEraseComponentStatus.NVMeDrivesEraseStatus Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Indicates the erase status of the individual components |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Idle |
Indicates SecureSystem Erase is not started |
Initiated |
Indicates Secure System Erase process is started |
InProgress |
Indicates Secure System Erase process is under progress |
CompletedWithSuccess |
Indicates Secure System Erase process has been completed with no errors |
CompletedWithErrors |
Indicates Secure System Erase process has been completed with some errors |
Failed |
Indicates Secure System Erase process has failed |
Oem.Hpe.UserDataEraseComponentStatus.SATADrivesEraseStatus Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Indicates the erase status of the individual components |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Idle |
Indicates SecureSystem Erase is not started |
Initiated |
Indicates Secure System Erase process is started |
InProgress |
Indicates Secure System Erase process is under progress |
CompletedWithSuccess |
Indicates Secure System Erase process has been completed with no errors |
CompletedWithErrors |
Indicates Secure System Erase process has been completed with some errors |
Failed |
Indicates Secure System Erase process has failed |
Oem.Hpe.UserDataEraseComponentStatus.SmartStorageEraseStatus Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Indicates the erase status of the individual components |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Idle |
Indicates SecureSystem Erase is not started |
Initiated |
Indicates Secure System Erase process is started |
InProgress |
Indicates Secure System Erase process is under progress |
CompletedWithSuccess |
Indicates Secure System Erase process has been completed with no errors |
CompletedWithErrors |
Indicates Secure System Erase process has been completed with some errors |
Failed |
Indicates Secure System Erase process has failed |
Oem.Hpe.UserDataEraseComponentStatus.TPMEraseStatus Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Indicates the erase status of the individual components |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Idle |
Indicates SecureSystem Erase is not started |
Initiated |
Indicates Secure System Erase process is started |
InProgress |
Indicates Secure System Erase process is under progress |
CompletedWithSuccess |
Indicates Secure System Erase process has been completed with no errors |
CompletedWithErrors |
Indicates Secure System Erase process has been completed with some errors |
Failed |
Indicates Secure System Erase process has failed |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Indicates the erase status of the individual components |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Idle |
Indicates SecureSystem Erase is not started |
Initiated |
Indicates Secure System Erase process is started |
InProgress |
Indicates Secure System Erase process is under progress |
CompletedWithSuccess |
Indicates Secure System Erase process has been completed with no errors |
CompletedWithErrors |
Indicates Secure System Erase process has been completed with some errors |
Failed |
Indicates Secure System Erase process has failed |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The current state of the systems virtual profile. This profile is the one that, when the server is rebooted, will set the Virtual properties. Intent is to use this state to determine whether the server needs to be rebooted so these values are set. Additional informaiton about the profile will be considered later. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Active |
Busy |
Inactive |
Unknown |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Used in conjunction with the UUID (Logical) value. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The manufacturer's system part number. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | This is the current power state of the system |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Null |
On |
Off |
Unknown |
Reset |
ProcessorSummary.Count Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The number of processors in the system. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
ProcessorSummary.Model Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The processor model for the primary or majority of processors in this system. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
ProcessorSummary.Status Member of ComputerSystem.v1_4_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
The central processors in the system.
Processors is a link ("@odata.id": URI
) to another resource.
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | SKU for this system. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
A reference to the UEFI SecureBoot resource associated with this system.
SecureBoot is a link ("@odata.id": URI
) to another resource.
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The system serial number. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of ComputerSystem.v1_4_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
A reference to the collection of storage devices associated with this system.
Storage is a link ("@odata.id": URI
) to another resource.
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The type of computer system that this resource represents. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Physical |
A computer system |
Virtual |
A virtual machine instance running on this system |
OS |
An operating system instance |
PhysicallyPartitioned |
A hardware-based partition of a computer system |
VirtuallyPartitioned |
A virtual or software-based partition of a computer system |
Member of ComputerSystem.v1_4_0.ComputerSystem
TrustedModules
is an array containing elements of:
TrustedModules[{item}].FirmwareVersion Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The firmware version of this Trusted Module |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
TrustedModules[{item}].InterfaceType Member of ComputerSystem.v1_4_0.ComputerSystem
Description | This property indicates the interface type of the Trusted Module. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
TM1_0 |
Trusted Module (TM) 1.0 |
TPM1_2 |
Trusted Platform Module (TPM) 1.2 |
TPM2_0 |
Trusted Platform Module (TPM) 2.0 |
TrustedModules[{item}].Oem.Hpe.VendorName Member of ComputerSystem.v1_4_0.ComputerSystem
Description | Trusted module vendor name. |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value |
---|
None |
STMicro |
Intel |
Nationz |
Unknown |
TrustedModules[{item}].Status Member of ComputerSystem.v1_4_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Member of ComputerSystem.v1_4_0.ComputerSystem
Description | The universal unique identifier for this system. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
ComputerSystem.Reset Member of ComputerSystem.v1_4_0.ComputerSystem
Parameters:
ResetType (string)
Value | Description |
---|---|
On | |
ForceOff | |
GracefulShutdown | |
ForceRestart | |
Nmi | |
PushPowerButton |
HpeComputerSystemExt.SystemReset Member of ComputerSystem.v1_4_0.ComputerSystem
Parameters:
ResetType (string)
ResetType identifies the type of Action to be performed.
Value | Description |
---|---|
ColdBoot | |
AuxCycle |
HpeComputerSystemExt.ServerIntelligentDiagnosticsMode Member of ComputerSystem.v1_4_0.ComputerSystem There are no parameters for this action.
HpeComputerSystemExt.ServerSafeMode Member of ComputerSystem.v1_4_0.ComputerSystem There are no parameters for this action.
HpeComputerSystemExt.RestoreSystemDefaults Member of ComputerSystem.v1_4_0.ComputerSystem There are no parameters for this action.
HpeComputerSystemExt.PowerButton Member of ComputerSystem.v1_4_0.ComputerSystem
Parameters:
PushType (string)
PushType identifies the type of Action to be performed.
Value | Description |
---|---|
Press | |
PressAndHold |
HpeComputerSystemExt.SecureSystemErase Member of ComputerSystem.v1_4_0.ComputerSystem
Parameters:
UserDataErase (boolean)
Action to perform erasing all the user data on the system including TPMs, persistent memory devices, storage controller configurations, RAID settings, as well as the hard drives attached to the system. USB and other removable media will be excluded.
SystemROMAndiLOErase (boolean)
Action to perform resetting the system BIOS settings and iLO to manufacturing defaults. It also erases the user data in the NAND like Active Health System(AHS), Repository.
HpeComputerSystemExt.ServerSigRecompute Member of ComputerSystem.v1_4_0.ComputerSystem There are no parameters for this action.
HpeComputerSystemExt.RestoreManufacturingDefaults Member of ComputerSystem.v1_4_0.ComputerSystem There are no parameters for this action.
@odata.type: "#ComputerSystemCollection.ComputerSystemCollection"
A Collection of ComputerSystem resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems |
GET |
Link Name | Destination type |
---|---|
Members[] |
ComputerSystem |
Member of ComputerSystemCollection.ComputerSystemCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of ComputerSystemCollection.ComputerSystemCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of ComputerSystemCollection.ComputerSystemCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#Drive.v1_0_0.Drive"
The Drive resource describes a single physical disk drive for a system, including links to associated Volumes.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/drives/{interface}/{item} |
GET |
Link Name | Destination type |
---|---|
Links/Volumes[] |
Volume |
Member of Drive.v1_0_0.Drive
Description | The size of the smallest addressible unit (Block) of this drive in bytes |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Drive.v1_0_0.Drive
Description | The speed which this drive can communicate to a storage controller in ideal conditions in Gigabits per second |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Drive.v1_0_0.Drive
Description | The size in bytes of this Drive |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Drive.v1_0_0.Drive
Description | Is this drive currently predicting a failure in the near future |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.10 |
Identifiers.DurableName Member of Drive.v1_0_0.Drive
Description | This indicates the world wide, persistent name of the resource. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Identifiers.DurableNameFormat Member of Drive.v1_0_0.Drive
Description | This represents the format of the DurableName property. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
EUI |
IEEE-defined 64-bit Extended Unique Identifier |
UUID |
Universally Unique Identifier |
Member of Drive.v1_0_0.Drive
Location
is an array containing elements of:
Location[{item}].Info Member of Drive.v1_0_0.Drive
Description | This indicates the location of the resource. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Location[{item}].InfoFormat Member of Drive.v1_0_0.Drive
Description | This represents the format of the Info property. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Box:Bay |
The Info is the box and bay number of the Drive. |
BayNumber |
The Info is the bay number of the Drive. |
Slot |
The Info is the PCIe slot of the Drive (eg: NVMe drives). |
Member of Drive.v1_0_0.Drive
Description | This is the manufacturer of this drive. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Drive.v1_0_0.Drive
Description | The type of media contained in this drive. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
HDD |
The drive media type is traditional magnetic platters |
SSD |
The drive media type is solid state or flash memory |
Member of Drive.v1_0_0.Drive
Description | This is the model number for the drive. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Drive.v1_0_0.Drive
Description | The speed which this drive is currently communicating to the storage controller in Gigabits per second |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Drive.v1_0_0.Drive
Description | Failure information reported by the drive. |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
AvailableSpareSpace |
Available spare space has fallen below the threshold. |
TemperatureTheshold |
A temperature is above an over temperature threshold or below an under temperature threshold. |
ReliabilityError |
The NVM subsystem reliability has been degraded due to significant media related errors or any internal error that degrades NVM subsystem reliability. |
ReadOnlyMode |
The media has been placed in read only mode. |
VolatileBackupFailure |
The volatile memory backup device has failed. This field is only valid if the controller has a volatile memory backup solution |
Member of Drive.v1_0_0.Drive
Description | The current temperature of the drive |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
Oem.Hpe.DriveStatus.Health Member of Drive.v1_0_0.Drive
Description | This represents the health state of this resource in the absence of its dependent resources. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OK |
Normal |
Warning |
A condition exists that requires attention |
Critical |
A critical condition exists that requires immediate attention |
Oem.Hpe.DriveStatus.HealthRollup Member of Drive.v1_0_0.Drive
Description | This represents the overall health state from the view of this resource. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OK |
Normal |
Warning |
A condition exists that requires attention |
Critical |
A critical condition exists that requires immediate attention |
Oem.Hpe.DriveStatus.State Member of Drive.v1_0_0.Drive
Description | This indicates the known state of the resource, such as if it is enabled. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Enabled |
This function or resource has been enabled. |
Disabled |
This function or resource has been disabled. |
StandbyOffline |
This function or resource is enabled, but awaiting an external action to activate it. |
StandbySpare |
This function or resource is part of a redundancy set and is awaiting a failover or other external action to activate it. |
InTest |
This function or resource is undergoing testing. |
Starting |
This function or resource is starting. |
Absent |
This function or resource is not present or not detected. |
UnavailableOffline |
This function or resource is present but cannot be used. |
Deferring |
The element will not process any commands but will queue new requests. |
Quiesced |
The element is enabled but only processes a restricted set of commands. |
Updating |
The element is updating and may be unavailable or degraded. |
Member of Drive.v1_0_0.Drive
Description | Describes how drive health related data (FailurePredicted, PredictedMediaLifeLeftPercent, Status, DriveStatus, CriticalWarning, WearStatus) are updated. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Boot |
The health related properties are updated when the system boot and are not updated at runtime. |
Dynamic |
The health related properties are updated periodically at runtime. |
Member of Drive.v1_0_0.Drive
Description | NVMe Identifier: ModelName, SerialNumber, PCI-Vendor-ID. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of Drive.v1_0_0.Drive
Description | The number of lifetime hours that the drive has been powered on. The value is null if the disk power on hours cannot be determined or is not supported. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Oem.Hpe.TemperatureStatus.Health Member of Drive.v1_0_0.Drive
Description | This represents the health state of this resource in the absence of its dependent resources. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OK |
Normal |
Warning |
A condition exists that requires attention |
Critical |
A critical condition exists that requires immediate attention |
Oem.Hpe.TemperatureStatus.HealthRollup Member of Drive.v1_0_0.Drive
Description | This represents the overall health state from the view of this resource. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OK |
Normal |
Warning |
A condition exists that requires attention |
Critical |
A critical condition exists that requires immediate attention |
Oem.Hpe.TemperatureStatus.State Member of Drive.v1_0_0.Drive
Description | This indicates the known state of the resource, such as if it is enabled. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Enabled |
This function or resource has been enabled. |
Disabled |
This function or resource has been disabled. |
StandbyOffline |
This function or resource is enabled, but awaiting an external action to activate it. |
StandbySpare |
This function or resource is part of a redundancy set and is awaiting a failover or other external action to activate it. |
InTest |
This function or resource is undergoing testing. |
Starting |
This function or resource is starting. |
Absent |
This function or resource is not present or not detected. |
UnavailableOffline |
This function or resource is present but cannot be used. |
Deferring |
The element will not process any commands but will queue new requests. |
Quiesced |
The element is enabled but only processes a restricted set of commands. |
Updating |
The element is updating and may be unavailable or degraded. |
Member of Drive.v1_0_0.Drive
Description | The wear status of the drive, an estimation of remaining life span. |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
OK |
The SSD is not in any imminent danger of wear out. |
FiftySixDayThreshold |
Indicates that based upon the current workload, the solid state disk will reach the maximum usage limit for writes (wear out) within fifty-six days. You should modify your write workload or begin preparing to replace your SSD drive |
FivePercentThreshold |
Indicates that the solid state disk has passed the five percent threshold and is at or below five percent of reaching the maximum usage limit for writes (wear out). You should begin to prepare to replace your SSD drive. |
TwoPercentThreshold |
Indicates that the solid state disk has passed the two percent threshold and is at or below two percent of reaching the maximum usage limit for writes (wear out). You should begin to prepare to replace your SSD drive. |
SSDWearOut |
Indicates that a solid state drive is approaching the maximum usage limit for writes (wear out) and should be replaced as soon as possible. |
Unknown |
The SSD wear status cannot be determined. |
Member of Drive.v1_0_0.Drive
Description | The part number for this drive. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Drive.v1_0_0.Drive
Description | The percentage of reads and writes that are predicted to still be available for the media |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Drive.v1_0_0.Drive
Description | The protocol this drive is using to communicate to the storage controller |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
NVMe |
Non-Volatile Memory Express |
SATA |
Serial AT Attachment |
USB |
Universal Serial Bus |
Member of Drive.v1_0_0.Drive
Description | The revision of this Drive |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Drive.v1_0_0.Drive
Description | The rotation speed of this Drive in Revolutions per Minute (RPM) |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Drive.v1_0_0.Drive
Description | Serial Number of the drive. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Drive.v1_0_0.Drive See the Redfish standard schema and specification for information on common Status object.
@odata.type: "#EthernetInterface.v1_4_1.EthernetInterface"
The EthernetInterface resource describes a single, logical ethernet interface or network interface controller (NIC).
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/ethernetinterfaces/{item} |
GET PATCH |
/redfish/v1/systems/{item}/ethernetinterfaces/{item} |
GET |
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This indicates if the speed and duplex are automatically negotiated and configured on this interface. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.10 |
DHCPv4.DHCPEnabled Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether DHCPv4 is enabled on this interface. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.40 |
DHCPv4.UseDNSServers Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether to use DHCPv4-supplied DNS servers. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.40 |
DHCPv4.UseDomainName Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether to use a DHCPv4-supplied domain name. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.40 |
DHCPv4.UseGateway Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether to use a DHCPv4-supplied gateway. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.40 |
DHCPv4.UseNTPServers Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether to use DHCPv4-supplied NTP servers. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.40 |
DHCPv4.UseStaticRoutes Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether to use DHCPv4-supplied static routes. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.40 |
DHCPv6.OperatingMode Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines the DHCPv6 operating mode for this interface. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Stateful |
DHCPv6 stateful mode. |
Stateless |
DHCPv6 stateless mode. |
Disabled |
DHCPv6 is disabled. |
DHCPv6.UseDNSServers Member of EthernetInterface.v1_4_1.EthernetInterface
Description | When enabled, DNS server addresses supplied through DHCPv6 stateless mode will be used. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.40 |
DHCPv6.UseDomainName Member of EthernetInterface.v1_4_1.EthernetInterface
Description | When enabled, the domain name supplied through DHCPv6 stateless mode will be used. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.40 |
DHCPv6.UseNTPServers Member of EthernetInterface.v1_4_1.EthernetInterface
Description | When enabled, NTP server addresses supplied through DHCPv6 stateless mode will be used. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.40 |
DHCPv6.UseRapidCommit Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether to use DHCPv6 rapid commit mode for stateful mode address assignments. Do not enable in networks where more than one DHCPv6 server is configured to provide address assignments. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.40 |
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the complete, fully qualified domain name obtained by DNS for this interface. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This indicates if the interface is in Full Duplex mode or not. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The DNS Host Name, without any domain information. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of EthernetInterface.v1_4_1.EthernetInterface
IPv4Addresses
is an array containing elements of:
IPv4Addresses[{item}].Address Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the IPv4 Address. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
IPv4Addresses[{item}].AddressOrigin Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This indicates how the address was determined. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Static |
A static address as configured by the user. |
DHCP |
Address is provided by a DHCPv4 service. |
BOOTP |
Address is provided by a BOOTP service. |
IPv4LinkLocal |
Address is valid only for this network segment (link). |
IPv4Addresses[{item}].Gateway Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the IPv4 gateway for this address. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
IPv4Addresses[{item}].SubnetMask Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the IPv4 Subnet mask. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
Member of EthernetInterface.v1_4_1.EthernetInterface
IPv4StaticAddresses
is an array containing elements of:
IPv4StaticAddresses[{item}].Address Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the IPv4 Address. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.40 |
IPv4StaticAddresses[{item}].AddressOrigin Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This indicates how the address was determined. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Static |
A static address as configured by the user. |
DHCP |
Address is provided by a DHCPv4 service. |
BOOTP |
Address is provided by a BOOTP service. |
IPv4LinkLocal |
Address is valid only for this network segment (link). |
IPv4StaticAddresses[{item}].Gateway Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the IPv4 gateway for this address. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.40 |
IPv4StaticAddresses[{item}].SubnetMask Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the IPv4 Subnet mask. |
Type | string |
Read Only | False |
Added | iLO 5 1.40 |
Member of EthernetInterface.v1_4_1.EthernetInterface
IPv6AddressPolicyTable
is an array containing elements of:
IPv6AddressPolicyTable[{item}].Label Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The IPv6 Label (as defined in RFC 6724 section 2.1). |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.10 |
IPv6AddressPolicyTable[{item}].Precedence Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The IPv6 Precedence (as defined in RFC 6724 section 2.1. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.10 |
IPv6AddressPolicyTable[{item}].Prefix Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The IPv6 Address Prefix (as defined in RFC 6724 section 2.1). |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of EthernetInterface.v1_4_1.EthernetInterface
IPv6Addresses
is an array containing elements of:
IPv6Addresses[{item}].Address Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the IPv6 Address. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
IPv6Addresses[{item}].AddressOrigin Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This indicates how the address was determined. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Static |
A static address as configured by the user. |
DHCPv6 |
Address is provided by a DHCPv6 service. |
LinkLocal |
Address is valid only for this network segment (link). |
SLAAC |
Address is provided by a Stateless Address AutoConfiguration (SLAAC) service. |
IPv6Addresses[{item}].AddressState Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The current state of this address as defined in RFC 4862. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Preferred |
This address is currently within both it's valid and preferred lifetimes as defined in RFC 4862. |
Deprecated |
This address is currently within it's valid lifetime, but is now outside of it's preferred lifetime as defined in RFC 4862. |
Tentative |
This address is currently undergoing Duplicate Address Detection testing as defined in RFC 4862 section 5.4. |
Failed |
This address has failed Duplicate Address Detection testing as defined in RFC 4862 section 5.4 and is not currently in use. |
IPv6Addresses[{item}].PrefixLength Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the IPv6 Address Prefix Length. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the IPv6 default gateway address that is currently in use on this interface. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of EthernetInterface.v1_4_1.EthernetInterface
IPv6StaticAddresses
is an array containing elements of:
IPv6StaticAddresses[{item}].Address Member of EthernetInterface.v1_4_1.EthernetInterface
Description | A valid IPv6 address. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
IPv6StaticAddresses[{item}].PrefixLength Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The Prefix Length of this IPv6 address. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of EthernetInterface.v1_4_1.EthernetInterface
IPv6StaticDefaultGateways
is an array containing elements of:
IPv6StaticDefaultGateways[{item}].Address Member of EthernetInterface.v1_4_1.EthernetInterface
Description | A valid IPv6 address. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.40 |
IPv6StaticDefaultGateways[{item}].PrefixLength Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The Prefix Length of this IPv6 address. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.40 |
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This indicates whether this interface is enabled. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.40 |
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The link status of this interface (port). |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
LinkUp |
The link is available for communication on this interface. |
NoLink |
There is no link or connection detected on this interface. |
LinkDown |
There is no link on this interface, but the interface is connected. |
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the currently configured MAC address of the (logical port) interface. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the currently configured Maximum Transmission Unit (MTU) in bytes on this interface. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.40 |
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This indicates the maximum number of Static IPv6 addresses that can be configured on this interface. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of EthernetInterface.v1_4_1.EthernetInterface
NameServers
is an array containing elements of:
Type | string |
Read Only | True |
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The state of the currently displayed configuration settings. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Current |
All configuration settings for this NIC are currently in use. |
SomePendingReset |
One or more configuration settings on this NIC are not yet in use. They require a reset of this management processor in order to take effect. |
Oem.Hpe.DHCPv4.ClientId Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The client ID to override the default used in iLO. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.40 |
Oem.Hpe.DHCPv4.ClientIdType Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The type of client id in use or to be selected. |
Type | string |
Read Only | False |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Custom |
Allows user to enter any value. |
Default |
Use the default iLO5 value - MAC Address + Instance number. |
Hostname |
Use the hostname. |
MacAddress |
Use the default iLO4 value - MAC Address. |
Oem.Hpe.DHCPv4.Enabled Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv4.DHCPEnabled, and will be removed in a future release. Determines whether DHCPv4 is enabled. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.DHCPv4.UseDNSServers Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv4.UseDNSServers, and will be removed in a future release. Determines whether to use DHCPv4-supplied DNS servers. Can only be enabled when DHCPv4 is also enabled; otherwise, this property will be set to false and will be read-only. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.DHCPv4.UseDomainName Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv4.UseDomainName, and will be removed in a future release. Determines whether to use a DHCPv4-supplied domain name. Can only be enabled when DHCPv4 is also enabled; otherwis,e this property will be set to false and will be read-only. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.DHCPv4.UseGateway Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv4.UseGateway, and will be removed in a future release. Determines whether to use a DHCPv4-supplied gateway. Can only be enabled when DHCPv4 is also enabled; otherwise, this property will be set to false and will be read-only. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.DHCPv4.UseNTPServers Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv4.UseNTPServers, and will be removed in a future release. Determines whether to use DHCPv4-supplied NTP servers. Can only be enabled when DHCPv4 is also enabled; otherwise, this property will be set to false and will be read-only. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.DHCPv4.UseStaticRoutes Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv4.UseStaticRoutes, and will be removed in a future release. Determines whether to use DHCPv4-supplied static routes. Can only be enabled when DHCPv4 is also enabled; otherwise, this property will be set to false and will be read-only. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.DHCPv4.UseWINSServers Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether to use DHCPv4-supplied WINS servers. Can only be enabled when DHCPv4 is also enabled; otherwise, this property will be set to false and will be read-only. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.DHCPv6.StatefulModeEnabled Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv6Configuration.OperatingMode, and will be removed in a future release.Determines whether DHCPv6 Stateful mode is enabled. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.DHCPv6.StatelessModeEnabled Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv6Configuration.OperatingMode, and will be removed in a future release. Determines whether DHCPv6 Stateless mode is enabled. Always enabled by default whenever DHCPv6 Stateful mode is also enabled. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.DHCPv6.UseDNSServers Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv6Configuration.UseDNSServers, and will be removed in a future release. Determines whether to use DHCPv6-supplied DNS servers. Can only be enabled when DHCPv6 Stateless mode is also enabled; otherwise, this property will be set to false and will be read-only. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.DHCPv6.UseDomainName Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv6Configuration.UseDomainName, and will be removed in a future release. Determines whether to use a DHCPv6-supplied domain name. Can only be enabled when DHCPv6 Stateless mode is also enabled; otherwise, this property will be set to false and will be read-only. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.DHCPv6.UseNTPServers Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv6Configuration.UseNTPServers, and will be removed in a future release. Determines whether to use DHCPv6-supplied NTP servers. Can only be enabled when DHCPv6 Stateless mode is also enabled; otherwise, this property will be set to false and will be read-only. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.DHCPv6.UseRapidCommit Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv6Configuration.UseRapidCommit, and will be removed in a future release. Determines whether to use DHCPv6 rapid commit mode. Can only be enabled when DHCPv6 Stateful mode is also enabled; otherwise, this property will be set to false and will be read-only. Do not enable in networks where more than one DHCPv6 server is configured to provide address assignments. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Domain name of the network to which this management processor belongs. This property can only be modified when the management processor is not configured to use a DHCP supplied domain name; otherwise this property is read-only indicating the value is provided by DHCP. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property HostName, and will be removed in a future release. The management processor host name. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
Format | hostname |
Oem.Hpe.IPv4.DDNSRegistration Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether DDNS registration is enabled. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.IPv4.DNSServers (array)
Member of EthernetInterface.v1_4_1.EthernetInterface
DNSServers
is an array containing elements of:
Type | string |
Read Only | True |
Format | ipv4 |
Oem.Hpe.IPv4.StaticRoutes (array)
Member of EthernetInterface.v1_4_1.EthernetInterface
StaticRoutes
is an array containing elements of:
StaticRoutes[{item}].Destination Member of EthernetInterface.v1_4_1.EthernetInterface
Description | An IPv4 static route destination. Only writeable when use of DHCPv4-supplied static routes is disabled; otherwise this property is read-only indicating the value is provided by DHCPv4. |
Type | string |
Read Only | False |
Format | ipv4 |
StaticRoutes[{item}].Gateway Member of EthernetInterface.v1_4_1.EthernetInterface
Description | An IPv4 static route gateway. Only writeable when use of DHCPv4-supplied static routes is disabled; otherwise this property is read-only indicating the value is provided by DHCPv4. |
Type | string |
Read Only | False |
Format | ipv4 |
StaticRoutes[{item}].SubnetMask Member of EthernetInterface.v1_4_1.EthernetInterface
Description | An IPv4 static route subnet mask. Only writeable when use of DHCPv4-supplied static routes is disabled; otherwise this property is read-only indicating the value is provided by DHCPv4. |
Type | string |
Read Only | False |
Format | ipv4 |
Oem.Hpe.IPv4.WINSRegistration Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether WINS registration is enabled. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.IPv4.WINSServers (array)
Member of EthernetInterface.v1_4_1.EthernetInterface
WINSServers
is an array containing elements of:
Type | string |
Read Only | True |
Format | ipv4 |
Oem.Hpe.IPv6.DDNSRegistration Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether IPv6 DDNS registration is enabled. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.IPv6.DNSServers (array)
Member of EthernetInterface.v1_4_1.EthernetInterface
DNSServers
is an array containing elements of:
Type | string |
Read Only | True |
Format | ipv6 |
Oem.Hpe.IPv6.SLAACEnabled Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property StatelessAddressAutoConfig.IPv6AutoConfigEnabled, and will be removed in a future release. Determines whether StateLess Address Auto-Configuration is enabled. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.IPv6.StaticDefaultGateway Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property IPv6StaticDefaultGateways[].Address, and will be removed in a future release. The IPv6 static default gateway entry. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
Format | ipv6 |
Oem.Hpe.IPv6.StaticRoutes (array)
Member of EthernetInterface.v1_4_1.EthernetInterface
StaticRoutes
is an array containing elements of:
StaticRoutes[{item}].Destination Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The IPv6 static route destination address. |
Type | string |
Read Only | False |
Format | ipv6 |
StaticRoutes[{item}].Gateway Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The IPv6 static route gateway. |
Type | string |
Read Only | False |
Format | ipv6 |
StaticRoutes[{item}].PrefixLength Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The prefix length of the IPv6 static route destination address. |
Type | integer or null |
Read Only | False |
StaticRoutes[{item}].Status Member of EthernetInterface.v1_4_1.EthernetInterface See the Redfish standard schema and specification for information on common Status object.
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Describes the network interface type. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Dedicated |
Shared |
HostInterface |
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property InterfaceEnabled, and will be removed in a future release. Determines whether this NIC is enabled or disabled. Enabling one NIC will disable the others. If no NIC is enabled, this management processor is not accessible over the network. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Indicates whether or not this NIC can support the IPv6 protocol. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether to ping the IPv4 gateway on startup. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.SharedNetworkPortOptions.NIC Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Selects the system NIC that is to be shared with this management processor. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
LOM |
The LOM NIC is configured to be shared. |
FlexibleLOM |
The FlexibleLOM NIC is configured to be shared. |
Oem.Hpe.SharedNetworkPortOptions.Port Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The network adapter port number that is used for sharing. This feature is only applicable on systems and network adapters that support it. |
Type | integer |
Read Only | False |
Added | iLO 5 1.10 |
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Indicates whether this system supports FlexibleLOM. Only applies to Shared Network Port. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Indicates whether this system supports LOM. Only applies to Shared Network Port. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the permanent MAC address assigned to this interface (port). |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the current speed in Mbps of this interface. |
Type | integer or null |
Read Only | False |
StatelessAddressAutoConfig.IPv4AutoConfigEnabled Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Indicates whether IPv4 SLAAC is enabled for this interface. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.40 |
StatelessAddressAutoConfig.IPv6AutoConfigEnabled Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Indicates whether IPv6 SLAAC is enabled for this interface. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.40 |
Member of EthernetInterface.v1_4_1.EthernetInterface
StaticNameServers
is an array containing elements of:
Type | string |
Read Only | True |
Member of EthernetInterface.v1_4_1.EthernetInterface See the Redfish standard schema and specification for information on common Status object.
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The UEFI device path for this interface. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
VLAN.VLANEnable Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This indicates if this VLAN is enabled. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.10 |
VLAN.VLANId Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This indicates the VLAN identifier for this VLAN. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.10 |
This is a reference to a collection of VLANs and is only used if the interface supports more than one VLANs.
VLANs is a link ("@odata.id": URI
) to another resource.
@odata.type: "#EthernetInterfaceCollection.EthernetInterfaceCollection"
A Collection of EthernetInterface resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/ethernetinterfaces |
GET |
/redfish/v1/systems/{item}/ethernetinterfaces |
GET |
Link Name | Destination type |
---|---|
Members[] |
EthernetInterface |
Member of EthernetInterfaceCollection.EthernetInterfaceCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of EthernetInterfaceCollection.EthernetInterfaceCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of EthernetInterfaceCollection.EthernetInterfaceCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#EventDestinationCollection.EventDestinationCollection"
A Collection of EventDestination resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/eventservice/subscriptions |
GET POST |
Link Name | Destination type |
---|---|
Members[] |
EventDestination |
Member of EventDestinationCollection.EventDestinationCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of EventDestinationCollection.EventDestinationCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of EventDestinationCollection.EventDestinationCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#EventService.v1_0_8.EventService"
The EventService resource describes the Event Service. It represents the properties for the service itself and has links to the actual list of subscriptions.
Uri | HTTP Allow |
---|---|
/redfish/v1/eventservice |
GET POST |
Link Name | Destination type |
---|---|
Subscriptions |
Collection of EventDestination |
Oem/Hpe/CACertificates |
Collection of HpeCertificate |
Member of EventService.v1_0_8.EventService
Description | This is the number of attempts an event posting is retried before the subscription is terminated. |
Type | integer |
Read Only | False |
Added | iLO 5 1.10 |
Member of EventService.v1_0_8.EventService
Description | This represents the number of seconds between retry attempts for sending any given Event |
Type | integer |
Read Only | False |
Added | iLO 5 1.10 |
Member of EventService.v1_0_8.EventService
EventTypesForSubscription
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
StatusChange |
The status of this resource has changed |
ResourceUpdated |
The value of this resource has been updated |
ResourceAdded |
A resource has been added |
ResourceRemoved |
A resource has been removed |
Alert |
A condition exists which requires attention |
The value of this property shall be a reference to a Collection of HpeCertificate resources.
CACertificates is a link ("@odata.id": URI
) to another resource.
Member of EventService.v1_0_8.EventService
Description | This represents the default number of events the service should queue. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of EventService.v1_0_8.EventService
Description | This represents the default number of minutes until an event is expired. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of EventService.v1_0_8.EventService
Description | The default number of TTLUnits until this listener destination subscription expires. It may be renewed prior to expire to reset the Time to Live counter. The value 999999 is reserved to mean a perpetual subscription. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of EventService.v1_0_8.EventService
Description | The default time unit used to measure the subscription time of this listener destination. This is the units for TTLCount and is used to express the subscription lifetime of the listener destination. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
seconds |
Time to Live (TTL) in Seconds |
minutes |
Time to Live (TTL) in Minutes |
days |
Time to Live (TTL) in Days |
Member of EventService.v1_0_8.EventService
Description | This indicates whether this service is enabled. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of EventService.v1_0_8.EventService See the Redfish standard schema and specification for information on common Status object.
This is a reference to a collection of ListenerDestination resources.
Subscriptions is a link ("@odata.id": URI
) to another resource.
EventService.SubmitTestEvent Member of EventService.v1_0_8.EventService
Parameters:
EventId (string)
Severity (string)
Value | Description |
---|---|
OK | |
Warning | |
Critical |
EventType (string)
Value | Description |
---|---|
StatusChange | |
ResourceUpdated | |
ResourceAdded | |
ResourceRemoved | |
Alert |
OriginOfCondition (string)
EventTimestamp (string)
MessageId (string)
Message (string)
MessageArgs (array)
HpeEventService.ImportCACertificate Member of EventService.v1_0_8.EventService Imports a Trusted CA Certificate
Parameters:
Certificate (string)
Contains PEM formatted X509 certificate or PKCS7 certificate chain (Base64 encoded).
@odata.type: "#HostInterface.v1_1_1.HostInterface"
The HostInterface resource describes a Redfish Host Interface, which is a method of accessing the Redfish API from the host computer system.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/hostinterfaces/{item} |
GET PATCH |
Member of HostInterface.v1_1_1.HostInterface
AuthenticationModes
is an array containing elements of:
AuthenticationModes[{item}].AuthenticationMode Member of HostInterface.v1_1_1.HostInterface
Type | string |
Read Only | False |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
AuthNone |
Requests without any sort of authentication are allowed. |
BasicAuth |
Requests using HTTP Basic Authentication are allowed. |
RedfishSessionAuth |
Requests using Redfish Session Authentication are allowed. |
OemAuth |
Requests using OEM authentication mechanisms are allowed. |
Member of HostInterface.v1_1_1.HostInterface
Description | This indicates whether this interface is accessible by external entities. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of HostInterface.v1_1_1.HostInterface
Description | This indicates whether this firmware authentication is enabled for this interface. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.40 |
Member of HostInterface.v1_1_1.HostInterface
Description | This property contains the Role for firmware authentication on this interface. |
Type | string |
Read Only | False |
Added | iLO 5 1.40 |
This is a reference to a collection of NICs that Computer Systems use for network communication with this Host Interface.
HostEthernetInterfaces is a link ("@odata.id": URI
) to another resource.
Member of HostInterface.v1_1_1.HostInterface
Description | This indicates the Host Interface type for this interface. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
NetworkHostInterface |
This interface is a Network Host Interface. |
Member of HostInterface.v1_1_1.HostInterface
Description | This indicates whether this interface is enabled. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.40 |
Member of HostInterface.v1_1_1.HostInterface
Description | This indicates whether this kernel authentication is enabled for this interface. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.40 |
Member of HostInterface.v1_1_1.HostInterface
Description | This property contains the Role for kernel authentication on this interface. |
Type | string |
Read Only | False |
Added | iLO 5 1.40 |
This is a reference to a single NIC that this Manager uses for network communication with this Host Interface.
ManagerEthernetInterface is a link ("@odata.id": URI
) to another resource.
This is a reference to the network services and their settings that the Manager controls. It is here that clients will find network configuration options as well as network services.
NetworkProtocol is a link ("@odata.id": URI
) to another resource.
Member of HostInterface.v1_1_1.HostInterface See the Redfish standard schema and specification for information on common Status object.
@odata.type: "#HostInterfaceCollection.HostInterfaceCollection"
A Collection of HostInterface resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/hostinterfaces |
GET |
Link Name | Destination type |
---|---|
Members[] |
HostInterface |
Member of HostInterfaceCollection.HostInterfaceCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HostInterfaceCollection.HostInterfaceCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HostInterfaceCollection.HostInterfaceCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeBaseConfigs.v2_0_0.HpeBaseConfigs"
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/bios/baseconfigs |
GET |
/redfish/v1/systems/{item}/bios/boot/baseconfigs |
GET |
/redfish/v1/systems/{item}/bios/iscsi/baseconfigs |
GET |
/redfish/v1/systems/{item}/bios/tlsconfig/baseconfigs |
GET |
Member of HpeBaseConfigs.v2_0_0.HpeBaseConfigs
BaseConfigs
is an array containing elements of:
Capabilities.BaseConfig Member of HpeBaseConfigs.v2_0_0.HpeBaseConfigs
Type | boolean |
Read Only | True |
Capabilities.BaseConfigs Member of HpeBaseConfigs.v2_0_0.HpeBaseConfigs
Type | boolean |
Read Only | True |
@odata.type: "#HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter"
The HpeBaseNetworkAdapter resource describes an Ethernet Adapter and its ports. Clients should use the Redfish NetworkAdapter and NetworkInterface resources when available instead of this.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/basenetworkadapters/{item} |
GET |
Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
FcPorts
is an array containing elements of:
FcPorts[{item}].PortNumber Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
Description | Port Number. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
FcPorts[{item}].WWNN Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
Description | World Wide Node Name. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
FcPorts[{item}].WWPN Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
Description | World Wide Port Name. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Firmware.Current Firmware.Current.VersionString Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
Description | This string represents the version of the firmware image. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
Description | The device part number. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
PhysicalPorts
is an array containing elements of:
PhysicalPorts[{item}].FullDuplex Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
Description | Full-duplex data transmission means that data can be transmitted in both directions on a signal carrier at the same time. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.10 |
PhysicalPorts[{item}].IPv4Addresses (array)
Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
IPv4Addresses
is an array containing elements of:
IPv4Addresses[{item}].Address Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
Description | This is the IPv4 Address. |
Type | string or null |
Read Only | True |
PhysicalPorts[{item}].IPv6Addresses (array)
Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
IPv6Addresses
is an array containing elements of:
IPv6Addresses[{item}].Address Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
Description | This is the IPv6 Address. |
Type | string or null |
Read Only | True |
Format | ipv6 |
PhysicalPorts[{item}].LinkStatus Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
Description | The link status of this interface (port). |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value |
---|
LinkUp |
NoLink |
LinkDown |
Null |
PhysicalPorts[{item}].MacAddress Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
Description | The port MAC address. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
PhysicalPorts[{item}].Oem.Hpe.BadReceives Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
Description | A count of frames that were received by the adapter but which had an error. This counter is the sum of mib items cpqNicIfPhysAdapterAlignmentErrors, cpqNicIfPhysAdapterFCSErrors, cpqNicIfPhysAdapterFrameTooLongs, and cpqNicIfPhysAdapterInternalMacReceiveErrors. If this counter increments frequently, check the more detailed error statistics and take appropriate action. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
PhysicalPorts[{item}].Oem.Hpe.BadTransmits Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
Description | A count of frames that were not transmitted by the adapter because of an error. This counter is the sum of MIB items cpqNicIfPhysAdapterDeferredTransmissions, cpqNicIfPhysAdapterLateCollisions, cpqNicIfPhysAdapterExcessiveCollisions, cpqNicIfPhysAdapterCarrierSenseErrors, and cpqNicIfPhysAdapterInternalMacTransmitErrors. If this counter increments frequently, check the more detailed error statistics and take appropriate action. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
PhysicalPorts[{item}].Oem.Hpe.GoodReceives Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
Description | A count of frames successfully received by the physical adapter. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
PhysicalPorts[{item}].Oem.Hpe.GoodTransmits Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
Description | A count of frames successfully transmitted by the physical adapter. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
PhysicalPorts[{item}].Oem.Hpe.StructuredName Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
Description | PCI device structured name in UTF-8 format (e.g. 'NIC.LOM.1.1' - see PCIDevices in /rest/v1/Systems/x/PCIDevices - this comes from SMBIOS |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
PhysicalPorts[{item}].Oem.Hpe.Team Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
Description | If a port is configured for NIC teaming, the name of the configured link between the physical ports that form a logical network adapter. This value is displayed for system NICs only (embedded and stand-up). |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
PhysicalPorts[{item}].SpeedMbps Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
Description | An estimate of the interface's current bandwidth in Megabits per second. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
PhysicalPorts[{item}].Status Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter See the Redfish standard schema and specification for information on common Status object.
PhysicalPorts[{item}].UEFIDevicePath Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
Description | UEFIDevice Path for correlation purposes |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
Description | The device serial number. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter See the Redfish standard schema and specification for information on common Status object.
Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
Description | PCI device structured name in UTF-8 format (e.g. 'NIC.LOM.1.1' - see PCIDevices in /rest/v1/Systems/x/PCIDevices - this comes from SMBIOS |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
Description | UEFIDevice Path for correlation purposes |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
@odata.type: "#HpeBaseNetworkAdapterCollection.HpeBaseNetworkAdapterCollection"
A Collection of HpeBaseNetworkAdapter resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/basenetworkadapters |
GET |
Link Name | Destination type |
---|---|
Members[] |
HpeBaseNetworkAdapter |
Member of HpeBaseNetworkAdapterCollection.HpeBaseNetworkAdapterCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeBaseNetworkAdapterCollection.HpeBaseNetworkAdapterCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeBaseNetworkAdapterCollection.HpeBaseNetworkAdapterCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeBiosMapping.v2_0_0.HpeBiosMapping"
This is the schema definition for the BIOS Attributes Mappings resource.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/bios/mappings |
GET |
Member of HpeBiosMapping.v2_0_0.HpeBiosMapping
Description | The Resource ID of the Attribute Registry for the BIOS Attributes resource. |
Type | string or null |
Read Only | True |
Member of HpeBiosMapping.v2_0_0.HpeBiosMapping
BiosPciSettingsMappings
is an array containing elements of:
BiosPciSettingsMappings[{item}].Associations (array)
Member of HpeBiosMapping.v2_0_0.HpeBiosMapping
Associations
is an array containing elements of:
BiosPciSettingsMappings[{item}].CorrelatableID Member of HpeBiosMapping.v2_0_0.HpeBiosMapping
Description | Contains any CorrelatableIDs that represent this PCI device. The CorrelatableID values can be JSON Pointers or UEFI identifiers. |
Type | string |
Read Only | True |
BiosPciSettingsMappings[{item}].Instance Member of HpeBiosMapping.v2_0_0.HpeBiosMapping
Description | The instance number of the parent PCI device for this association set. |
Type | integer |
Read Only | True |
BiosPciSettingsMappings[{item}].Subinstances (array)
Member of HpeBiosMapping.v2_0_0.HpeBiosMapping
Subinstances
is an array containing elements of:
Subinstances[{item}].Associations (array)
Member of HpeBiosMapping.v2_0_0.HpeBiosMapping
Associations
is an array containing elements of:
Type | string |
Read Only | True |
Subinstances[{item}].CorrelatableID Member of HpeBiosMapping.v2_0_0.HpeBiosMapping
Description | Contains any CorrelatableIDs that represent this PCI device. The CorrelatableID values can be JSON Pointers or UEFI identifiers. |
Type | string |
Read Only | True |
Subinstances[{item}].Subinstance Member of HpeBiosMapping.v2_0_0.HpeBiosMapping
Description | The sub-instance number of the child PCI device for this association set. |
Type | integer |
Read Only | True |
@odata.type: "#HpeCertAuth.v1_1_0.HpeCertAuth"
The HpeCertAuth resource describes the BMC certificate based authentication feature.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/securityservice/certificateauthentication |
GET POST PATCH |
Link Name | Destination type |
---|---|
CACertificates |
Collection of HpeCertificate |
Links/UserCertificateMapping |
Collection of HpeiLOAccountCertificateMap |
The value of this property shall be a reference to a Collection of HpeCertificate resources.
CACertificates is a link ("@odata.id": URI
) to another resource.
Member of HpeCertAuth.v1_1_0.HpeCertAuth
Description | Issuer of the installed CRL, if present. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeCertAuth.v1_1_0.HpeCertAuth
Description | Serial Number of the installed CRL, if present. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeCertAuth.v1_1_0.HpeCertAuth
Description | Specifies whether Certificate login is enabled. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeCertAuth.v1_1_0.HpeCertAuth
Description | The method used to map a certificate to its associated LDAP user account. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
SubjectCN |
The CN portion of the certificate subject will be used as the LDAP username. |
SubjectDN |
The fully qualified DN of the certificate subject will be used as the LDAP username. |
SANRFC822 |
The RFC822 name from the certificate's subjectAlternativeName extension will be used as the LDAP username. |
SANUPN |
The UserPrincipalName from the certificate's subjectAlternativeName extension will be used as the LDAP username. |
Member of HpeCertAuth.v1_1_0.HpeCertAuth
Description | URL to use for OCSP certificate checking. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.15 |
Format | uri-reference |
Member of HpeCertAuth.v1_1_0.HpeCertAuth
Description | Whether or not Strict CAC Mode is enabled. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
HpeCertAuth.DeleteCRL Member of HpeCertAuth.v1_1_0.HpeCertAuth Remove an installed Certificate Revocation List (CRL).
There are no parameters for this action.
HpeCertAuth.ImportCRL Member of HpeCertAuth.v1_1_0.HpeCertAuth Imports a Certificate Revocation List (CRL).
Parameters:
ImportUri (string)
Contains URI of PEM formatted certificate revocation list (CRL) (Base64 encoded).
HpeCertAuth.ImportCACertificate Member of HpeCertAuth.v1_1_0.HpeCertAuth Imports a Trusted Certificate
Parameters:
Certificate (string)
Contains PEM formatted X509 certificate or PKCS7 certificate chain (Base64 encoded).
@odata.type: "#HpeCertificateCollection.HpeCertificateCollection"
A Collection of HpeCertificate resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/eventservice/cacertificates |
GET |
/redfish/v1/managers/{item}/securityservice/certificateauthentication/cacertificates |
GET |
Link Name | Destination type |
---|---|
Members[] |
HpeCertificate |
Member of HpeCertificateCollection.HpeCertificateCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeCertificateCollection.HpeCertificateCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeCertificateCollection.HpeCertificateCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeComponent.v1_0_1.HpeComponent"
The HpeComponent resource describes a software or firmware update component.
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/componentrepository/{item} |
GET PATCH DELETE |
Member of HpeComponent.v1_0_1.HpeComponent
Description | Indicates when a component becomes active after being updated. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Immediately |
The update activates immediately. |
AfterReboot |
The update activates after a host server reboot. |
AfterDeviceReset |
The update activates after a device reset. |
AfterHardPowerCycle |
The update activates after a full power supply disconnect or E-Fuse reset. |
Member of HpeComponent.v1_0_1.HpeComponent
Description | HTTP-style content-type of binary |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeComponent.v1_0_1.HpeComponent
Description | URI of the component binary. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | uri-reference |
Member of HpeComponent.v1_0_1.HpeComponent
Description | string defining customized parameters for some components provided by client at upload time and given to the component at execution time (Type D only). |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeComponent.v1_0_1.HpeComponent
Description | ISO 8601 time string indicating when this component was added to the NAND. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
Member of HpeComponent.v1_0_1.HpeComponent
Member of HpeComponent.v1_0_1.HpeComponent
Member of HpeComponent.v1_0_1.HpeComponent
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Optional |
Recommended |
Critical |
Member of HpeComponent.v1_0_1.HpeComponent
Description | Device type GUID from iLO secure flash header |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeComponent.v1_0_1.HpeComponent
Description | Client supplied execution parameters. These are supplied at upload time and given to the component at execution time (Type D only). |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeComponent.v1_0_1.HpeComponent
Description | The unique filename of the component. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeComponent.v1_0_1.HpeComponent
Description | Path of file on the USB LUN if you mount the repo as USB. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeComponent.v1_0_1.HpeComponent
Description | If true, this component cannot be removed with DELETE because it is referenced by an Install Set |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeComponent.v1_0_1.HpeComponent
Description | Size of the component file in bytes. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeComponent.v1_0_1.HpeComponent
Targets
is an array containing elements of:
Description | Target GUIDs from secure flash header or sidecar file. |
Type | string |
Read Only | True |
Member of HpeComponent.v1_0_1.HpeComponent
UpdatableBy
is an array containing elements of:
Description | Describes which types of update agents may apply this component. |
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Uefi |
This component may be scheduled for update by UEFI BIOS. |
RuntimeAgent |
This component may be scheduled for update by a runtime update agent such as Smart Update Manager or Smart Update Tool. |
Bmc |
This component may be scheduled for update by iLO. |
Member of HpeComponent.v1_0_1.HpeComponent
Description | Version of the component from secure flash header or sidecar file. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
@odata.type: "#HpeComponentCollection.HpeComponentCollection"
A Collection of HpeComponent resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/componentrepository |
GET |
Link Name | Destination type |
---|---|
Members[] |
HpeComponent |
Member of HpeComponentCollection.HpeComponentCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeComponentCollection.HpeComponentCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeComponentCollection.HpeComponentCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Member of HpeComponentCollection.HpeComponentCollection
Description | The number of files reported. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeComponentCollection.HpeComponentCollection
Description | The available repository space in bytes. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeComponentCollection.HpeComponentCollection
Description | The total repository size in bytes. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
@odata.type: "#HpeComponentInstallSet.v1_1_0.HpeComponentInstallSet"
The HpeComponentInstallSet resource describes an Install Set, an ordered list of installation instructions that may be invoked.
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/installsets/{item} |
GET POST PATCH DELETE |
Member of HpeComponentInstallSet.v1_1_0.HpeComponentInstallSet
Description | ISO-time of install set creation. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
Member of HpeComponentInstallSet.v1_1_0.HpeComponentInstallSet
Description | If true, this install set is reserved to hold only critical firmware recovery updatable by iLO. Additionally the 'Administrate Recovery Set' iLO privilege is required to modify or remove this install set. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeComponentInstallSet.v1_1_0.HpeComponentInstallSet
Description | ISO-time of install modification. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
Member of HpeComponentInstallSet.v1_1_0.HpeComponentInstallSet
Sequence
is an array containing elements of:
Sequence[{item}].Command Member of HpeComponentInstallSet.v1_1_0.HpeComponentInstallSet
Description | Command to execute. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
ApplyUpdate |
Apply an update using the specified component. |
ResetServer |
Reset the server. |
ResetBmc |
Reset the BMC. |
Wait |
Wait for the WaitTimeSeconds number of seconds. |
Sequence[{item}].Component Member of HpeComponentInstallSet.v1_1_0.HpeComponentInstallSet
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | uri-reference |
Sequence[{item}].ExecutionTimeoutMinutes Member of HpeComponentInstallSet.v1_1_0.HpeComponentInstallSet
Description | The number of minutes that this update will likely take to apply. Applies if the command is 'ApplyUpdate'. Ignored otherwise. |
Type | integer |
Read Only | False |
Sequence[{item}].Filename Member of HpeComponentInstallSet.v1_1_0.HpeComponentInstallSet
Description | The unique filename of the component. This correlates to 'Filename' in the HpeComponent. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
Sequence[{item}].UpdatableBy (array)
Member of HpeComponentInstallSet.v1_1_0.HpeComponentInstallSet
UpdatableBy
is an array containing elements of:
Type | string |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Bmc |
This component may be scheduled for update by iLO. |
Uefi |
This component may be scheduled for update by UEFI BIOS. |
RuntimeAgent |
This component may be scheduled for update by a runtime update agent such as Smart Update Manager or Smart Update Tool. |
Sequence[{item}].WaitTimeSeconds Member of HpeComponentInstallSet.v1_1_0.HpeComponentInstallSet
Description | The number of seconds to pause if the command is 'Wait'. Ignored otherwise. |
Type | integer |
Read Only | False |
Added | iLO 5 1.10 |
HpeComponentInstallSet.Invoke Member of HpeComponentInstallSet.v1_1_0.HpeComponentInstallSet
Parameters:
ClearTaskQueue (boolean)
Previous items in the task queue can be cleared before the Install Set is invoked
@odata.type: "#HpeComponentInstallSetCollection.HpeComponentInstallSetCollection"
A Collection of HpeComponentInstallSet resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/installsets |
GET POST |
Link Name | Destination type |
---|---|
Members[] |
HpeComponentInstallSet |
Member of HpeComponentInstallSetCollection.HpeComponentInstallSetCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeComponentInstallSetCollection.HpeComponentInstallSetCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeComponentInstallSetCollection.HpeComponentInstallSetCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeComponentUpdateTask.v1_2_0.HpeComponentUpdateTask"
The HpeComponentUpdateTask resource describes an Update Task, an element in the update task queue. This represents an install instruction.
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/updatetaskqueue/{item} |
Member of HpeComponentUpdateTask.v1_2_0.HpeComponentUpdateTask
Description | Command to execute. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
ApplyUpdate |
Apply an update using the specified component. |
ResetServer |
Reset the server. |
ResetBmc |
Reset the BMC. |
Wait |
Wait for the WaitTimeSeconds number of seconds. |
Member of HpeComponentUpdateTask.v1_2_0.HpeComponentUpdateTask
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | uri-reference |
Member of HpeComponentUpdateTask.v1_2_0.HpeComponentUpdateTask
Description | ISO-time of task creation (by whomever created this thing) |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
Member of HpeComponentUpdateTask.v1_2_0.HpeComponentUpdateTask
Description | The number of minutes that this update will likely take to apply. Applies if the command is 'ApplyUpdate'. Ignored otherwise. |
Type | integer |
Read Only | False |
Member of HpeComponentUpdateTask.v1_2_0.HpeComponentUpdateTask
Description | ISO 8601 Redfish-style time string after which we will automatically change state to Expired - null for no expire time |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
Format | date-time |
Member of HpeComponentUpdateTask.v1_2_0.HpeComponentUpdateTask
Description | The unique filename of the component. This correlates to 'Filename' in the HpeComponent. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeComponentUpdateTask.v1_2_0.HpeComponentUpdateTask
Description | The maintenance window for this update task. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.30 |
Member of HpeComponentUpdateTask.v1_2_0.HpeComponentUpdateTask
Description | ISO-time of last task queue item update by updater (not client) |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
Member of HpeComponentUpdateTask.v1_2_0.HpeComponentUpdateTask
Description | This task was created by a user with Recovery Set privilege, and would allow a downgrade if 'DowngradePolicy' is set to 'RecoveryDowngrade'. Applies if the command is 'ApplyUpdate'. Ignored otherwise. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.40 |
Result.MessageArgs (array)
Member of HpeComponentUpdateTask.v1_2_0.HpeComponentUpdateTask
MessageArgs
is an array containing elements of:
Type | string |
Read Only | True |
Result.MessageId Member of HpeComponentUpdateTask.v1_2_0.HpeComponentUpdateTask
Description | The key for this message that can be used to look up the message in a message registry. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeComponentUpdateTask.v1_2_0.HpeComponentUpdateTask
Description | base64 encoded entry to capture component log. Estimated to be generally 1-2KB. written by updater |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeComponentUpdateTask.v1_2_0.HpeComponentUpdateTask
Description | ISO 8601 Redfish-style time string of earliest execution - null for no start time specified |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
Format | date-time |
Member of HpeComponentUpdateTask.v1_2_0.HpeComponentUpdateTask
Description | The current state of the update task. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Pending |
The task is pending execution. |
InProgress |
The task is executing. |
Complete |
The task was completed and the results are available in the Results. |
Expired |
The task will not execute because the current time is after the 'Expire' time. |
Exception |
The task was unsuccessful because of an exception condition. |
Canceled |
The task is no longer scheduled to run. |
Member of HpeComponentUpdateTask.v1_2_0.HpeComponentUpdateTask
Description | If true then the TPMOverrideFlag is passed in on the associated flash operations. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeComponentUpdateTask.v1_2_0.HpeComponentUpdateTask
UpdatableBy
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Bmc |
This component may be scheduled for update by iLO. |
Uefi |
This component may be scheduled for update by UEFI BIOS. |
RuntimeAgent |
This component may be scheduled for update by a runtime update agent such as Smart Update Manager or Smart Update Tool. |
Member of HpeComponentUpdateTask.v1_2_0.HpeComponentUpdateTask
Description | Update Recovery Set with this component if the command is 'ApplyUpdate'. Ignored otherwise. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.20 |
Member of HpeComponentUpdateTask.v1_2_0.HpeComponentUpdateTask
Description | The number of seconds to pause if the command is 'Wait'. Ignored otherwise. |
Type | integer |
Read Only | False |
Added | iLO 5 1.10 |
@odata.type: "#HpeComponentUpdateTaskQueueCollection.HpeComponentUpdateTaskQueueCollection"
A Collection of HpeComponentUpdateTaskQueue resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/updatetaskqueue |
Link Name | Destination type |
---|---|
Members[] |
HpeComponentUpdateTask |
Member of HpeComponentUpdateTaskQueueCollection.HpeComponentUpdateTaskQueueCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeComponentUpdateTaskQueueCollection.HpeComponentUpdateTaskQueueCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeComponentUpdateTaskQueueCollection.HpeComponentUpdateTaskQueueCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeDirectoryTest.v1_0_0.HpeDirectoryTest"
The HpeDirectoryTest resource describes the BMC directory test.
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/directorytest |
GET POST |
Member of HpeDirectoryTest.v1_0_0.HpeDirectoryTest
Description | Represents the overall status of directory tests. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
NotRun |
The Overall Directory Test was not run. |
InProgress |
The Overall Directory Test is in progress. |
Success |
The Overall Directory Test has completed successfully. |
Warning |
The Overall Directory Test has completed with warning. |
Failed |
The Overall Directory Test has failed. |
Error |
The Directory Test has encountered an error condition. |
Member of HpeDirectoryTest.v1_0_0.HpeDirectoryTest
TestResults
is an array containing elements of:
TestResults[{item}].Notes Member of HpeDirectoryTest.v1_0_0.HpeDirectoryTest
Description | This provides additional details on the directory test. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
TestResults[{item}].Status Member of HpeDirectoryTest.v1_0_0.HpeDirectoryTest See the Redfish standard schema and specification for information on common Status object.
TestResults[{item}].TestName Member of HpeDirectoryTest.v1_0_0.HpeDirectoryTest
Description | The name of directory test. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
HpeDirectoryTest.StartTest Member of HpeDirectoryTest.v1_0_0.HpeDirectoryTest Start the directory test.
Parameters:
@odata.type: "#HpeESKM.v2_0_0.HpeESKM"
The HpeESKM resource describes properties for managing the ESKM feature. ESKM (Enterprise Security Key Manager) enables connections to an operational key manager,change redundancy settings,view the key manager connection settings,test the connection,and view key management events.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/securityservice/eskm |
GET POST PATCH |
Member of HpeESKM.v2_0_0.HpeESKM
ESKMEvents
is an array containing elements of:
ESKMEvents[{item}].Event Member of HpeESKM.v2_0_0.HpeESKM
Description | ESKM event description. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
ESKMEvents[{item}].Timestamp Member of HpeESKM.v2_0_0.HpeESKM
Description | Time of ESKM event. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
KeyManagerConfig.AccountGroup Member of HpeESKM.v2_0_0.HpeESKM
Description | Account group on ESKM. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
KeyManagerConfig.AccountName Member of HpeESKM.v2_0_0.HpeESKM
Description | Account name on ESKM. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
KeyManagerConfig.ESKMLocalCACertificateName Member of HpeESKM.v2_0_0.HpeESKM
Description | This is the name of Local CA (Certificate Authority) in ESKM that is used to sign the ESKM server certificate. iLO will retrieve this certificate from the ESKM server. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
KeyManagerConfig.ImportedCertificateIssuer Member of HpeESKM.v2_0_0.HpeESKM
Description | Imported certificate issuer. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
KeyManagerConfig.ImportedCertificateSubject Member of HpeESKM.v2_0_0.HpeESKM
Description | Imported certificate subject. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
KeyManagerConfig.LoginName Member of HpeESKM.v2_0_0.HpeESKM
Description | ESKM administrator account login name. This property always returns null on GET. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
KeyManagerConfig.Password Member of HpeESKM.v2_0_0.HpeESKM
Description | ESKM administrator account password. This property always returns null on GET. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeESKM.v2_0_0.HpeESKM
Description | If true encryption keys will be maintained on both the configured key servers. When this option is disabled, iLO will not verify that encryption keys are copied to both of the configured key servers. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeESKM.v2_0_0.HpeESKM
Description | Primary key server IP address or FQDN. Set to null to clear the value. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeESKM.v2_0_0.HpeESKM
Description | Primary key server port number. Set to null to clear the value. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeESKM.v2_0_0.HpeESKM
Description | Secondary key server IP address or FQDN. Set to null to clear the value. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeESKM.v2_0_0.HpeESKM
Description | Secondary key server port number. Set to null to clear the value. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.10 |
HpeESKM.ClearESKMLog Member of HpeESKM.v2_0_0.HpeESKM Clears ESKM log.
There are no parameters for this action.
HpeESKM.TestESKMConnections Member of HpeESKM.v2_0_0.HpeESKM Test ESKM connections.
There are no parameters for this action.
@odata.type: "#HpeHttpsCert.v2_0_0.HpeHttpsCert"
The HpeHttpsCert resource describes an X509 certificate.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/securityservice/httpscert |
GET POST DELETE |
Member of HpeHttpsCert.v2_0_0.HpeHttpsCert
Description | GenerateCSR action, wait few minutes (upto 10), perform GET operation, fills CSR. Contains a public and private key pair. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
X509CertificateInformation.Issuer Member of HpeHttpsCert.v2_0_0.HpeHttpsCert
Description | The Certificate Authority that issued the certificate. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
X509CertificateInformation.SerialNumber Member of HpeHttpsCert.v2_0_0.HpeHttpsCert
Description | The serial number that the Certificate Authority assigned to the certificate. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
X509CertificateInformation.Subject Member of HpeHttpsCert.v2_0_0.HpeHttpsCert
Description | The entity to which the certificate was issued. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
X509CertificateInformation.ValidNotAfter Member of HpeHttpsCert.v2_0_0.HpeHttpsCert
Description | The date on which the certificate validity period ends. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
X509CertificateInformation.ValidNotBefore Member of HpeHttpsCert.v2_0_0.HpeHttpsCert
Description | The date on which the certificate validity period begins. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
HpeHttpsCert.ImportCertificate Member of HpeHttpsCert.v2_0_0.HpeHttpsCert Imports a Trusted Certificate and iLO is reset.
Parameters:
Certificate (string)
Contains PEM formatted X509 certificate (Base64 encoded).
HpeHttpsCert.GenerateCSR Member of HpeHttpsCert.v2_0_0.HpeHttpsCert
Parameters:
City (string)
The city or locality where the company or organization that owns this iLO subsystem is located.
OrgName (string)
The name of the company or organization that owns this iLO subsystem.
Country (string)
The two-character country code where the company or organization that owns this Manager subsystem is located. Eg: US
CommonName (string)
The FQDN of this iLO subsystem.
IncludeIP (boolean)
Include the IP Addresses in the CSR.
OrgUnit (string)
The unit within the company or organization that owns this iLO subsystem.
State (string)
The state where the company or organization that owns this iLO subsystem is located.
@odata.type: "#HpeiLOAccountCertificateMapCollection.HpeiLOAccountCertificateMapCollection"
A Collection of HpeiLOAccountCertificateMap resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/usercertificatemapping |
GET POST |
Link Name | Destination type |
---|---|
Members[] |
HpeiLOAccountCertificateMap |
Member of HpeiLOAccountCertificateMapCollection.HpeiLOAccountCertificateMapCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeiLOAccountCertificateMapCollection.HpeiLOAccountCertificateMapCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeiLOAccountCertificateMapCollection.HpeiLOAccountCertificateMapCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeiLOActiveHealthSystem.v2_3_0.HpeiLOActiveHealthSystem"
The HpeiLOActiveHealthSystem resource describes the properties for managing the Active Health System.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/activehealthsystem |
GET POST PATCH |
Member of HpeiLOActiveHealthSystem.v2_3_0.HpeiLOActiveHealthSystem
Description | Determines whether HPE Active Health System logging is enabled or disabled. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeiLOActiveHealthSystem.v2_3_0.HpeiLOActiveHealthSystem
Description | The end of the AHS log. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
Member of HpeiLOActiveHealthSystem.v2_3_0.HpeiLOActiveHealthSystem
Description | The start of the AHS log. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
AHSStatus.HardwareEnabled Member of HpeiLOActiveHealthSystem.v2_3_0.HpeiLOActiveHealthSystem
Description | Determines whether HPE Active Health System logging in hardware is enabled or not. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
AHSStatus.SoftwareEnabled Member of HpeiLOActiveHealthSystem.v2_3_0.HpeiLOActiveHealthSystem
Description | Determines whether HPE Active Health System logging in software is enabled or not. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
AHSStatus.TemporaryHoldEnabled Member of HpeiLOActiveHealthSystem.v2_3_0.HpeiLOActiveHealthSystem
Description | Determines whether HPE Active Health System logging access is temporarily disabled. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
LocationParameters.case_no Member of HpeiLOActiveHealthSystem.v2_3_0.HpeiLOActiveHealthSystem
Description | This query parameter may be added to the AHS location URI to insert the case number into the AHS log header. For example, http://iloname.example.net/ahsdata/HPE_xxxxxxxxxx_20140821.ahs?downloadAll=1&&case_no=abc123. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
LocationParameters.co_name Member of HpeiLOActiveHealthSystem.v2_3_0.HpeiLOActiveHealthSystem
Description | This query parameter may be added to the AHS location URI to insert the company name into the AHS log header. For example, http://iloname.example.net/ahsdata/HPE_xxxxxxxxxx_20140821.ahs?downloadAll=1&&co_name=myCompany. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
LocationParameters.contact_name Member of HpeiLOActiveHealthSystem.v2_3_0.HpeiLOActiveHealthSystem
Description | This query parameter may be added to the AHS location URI to insert the contact name into the AHS log header. For example, http://iloname.example.net/ahsdata/HPE_xxxxxxxxxx_20140821.ahs?downloadAll=1&&contact_name=JohnDoe. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
LocationParameters.days Member of HpeiLOActiveHealthSystem.v2_3_0.HpeiLOActiveHealthSystem
Description | This query parameter should be used to download the most recent N days of the AHS log. For example, http://iloname.example.net/ahsdata/HPE_xxxxxxxxxx_20140821.ahs?days=7. Will retrive logs made within the last 7 days. |
Type | string |
Read Only | True |
Added | iLO 5 1.15 |
LocationParameters.downloadAll Member of HpeiLOActiveHealthSystem.v2_3_0.HpeiLOActiveHealthSystem
Description | This query parameter should be used to download entire AHS log. For example, http://iloname.example.net/ahsdata/HPE_xxxxxxxxxx_20140821.ahs?downloadAll=1. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
LocationParameters.email Member of HpeiLOActiveHealthSystem.v2_3_0.HpeiLOActiveHealthSystem
Description | This query parameter may be added to the AHS location URI to insert the contacts email address into the AHS log header. For example, http://iloname.example.net/ahsdata/HPE_xxxxxxxxxx_20140821.ahs?downloadAll=1&&email=abc@xyz.com. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
LocationParameters.from Member of HpeiLOActiveHealthSystem.v2_3_0.HpeiLOActiveHealthSystem
Description | This query parameter must be added with the 'to' query parameter to the AHS location URI to limit the range of data returned. 'downloadAll' parameter should not be used with this query parameter. For example, http://iloname.example.net/ahsdata/HPE_xxxxxxxxxx_20140821.ahs?from=2014-03-01&&to=2014-03-30. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
LocationParameters.phone Member of HpeiLOActiveHealthSystem.v2_3_0.HpeiLOActiveHealthSystem
Description | This query parameter may be added to the AHS location URI to insert the contacts phone number into the AHS log header. For example, http://iloname.example.net/ahsdata/HPE_xxxxxxxxxx_20140821.ahs?downloadAll=1&&contact_name=JohnDoe&&phone=555-555-5555. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
LocationParameters.to Member of HpeiLOActiveHealthSystem.v2_3_0.HpeiLOActiveHealthSystem
Description | This query parameter must be added with the 'from' query parameter to the AHS location URI to limit the range of data returned.'downloadAll' parameter should not be used with this query parameter. For example, http://iloname.example.net/ahsdata/HPE_xxxxxxxxxx_20140821.ahs?from=2014-03-01&&to=2014-03-30. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
HpeiLOActiveHealthSystem.LogAmplifierData Member of HpeiLOActiveHealthSystem.v2_3_0.HpeiLOActiveHealthSystem
Parameters:
iLOAmplifierName (string)
Name of the iLO Amplifier instance that manages this iLO.
iLOAmplifierManagesCount (integer)
Number of iLOs that this Amplifier instance manages.
HpeiLOActiveHealthSystem.ClearLog Member of HpeiLOActiveHealthSystem.v2_3_0.HpeiLOActiveHealthSystem There are no parameters for this action.
@odata.type: "#HpeiLOBackupFile.v1_0_0.HpeiLOBackupFile"
The HpeiLOBackupFile resource describes the properties for managing BMC backup files.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/backuprestoreservice/backupfiles/{item} |
Member of HpeiLOBackupFile.v1_0_0.HpeiLOBackupFile
Description | ISO-time of backup file creation (by whomever created this thing) |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
Format | date-time |
Member of HpeiLOBackupFile.v1_0_0.HpeiLOBackupFile
Description | Size of backup file. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of HpeiLOBackupFile.v1_0_0.HpeiLOBackupFile
Description | iLO firmware version running when this backup file was created. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
HpeiLOBackupFile.Restore Member of HpeiLOBackupFile.v1_0_0.HpeiLOBackupFile There are no parameters for this action.
@odata.type: "#HpeiLOBackupFileCollection.HpeiLOBackupFileCollection"
A Collection of HpeiLOBackupFile resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/backuprestoreservice/backupfiles |
Link Name | Destination type |
---|---|
Members[] |
HpeiLOBackupFile |
Member of HpeiLOBackupFileCollection.HpeiLOBackupFileCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeiLOBackupFileCollection.HpeiLOBackupFileCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeiLOBackupFileCollection.HpeiLOBackupFileCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Member of HpeiLOBackupFileCollection.HpeiLOBackupFileCollection
Description | The number of backup files reported. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of HpeiLOBackupFileCollection.HpeiLOBackupFileCollection
Description | The number of backup files supported. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.40 |
@odata.type: "#HpeiLOBackupRestoreService.v2_2_0.HpeiLOBackupRestoreService"
The HpeiLOBackupRestoreService resource describes the properties for using the BMC backup and restore features.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/backuprestoreservice |
GET |
Member of HpeiLOBackupRestoreService.v2_2_0.HpeiLOBackupRestoreService
Description | The URI to which a client may POST to create and download a file for a subsequent restore operation. |
Type | string |
Read Only | True |
Added | iLO 5 1.15 |
Format | uri-reference |
Link to backup files.
BackupFiles is a link ("@odata.id": URI
) to another resource.
Member of HpeiLOBackupRestoreService.v2_2_0.HpeiLOBackupRestoreService
Description | The URI to which a client may POST a file for a subsequent restore operation. |
Type | string |
Read Only | True |
Added | iLO 5 1.15 |
Format | uri-reference |
@odata.type: "#HpeiLODateTime.v2_0_0.HpeiLODateTime"
The HpeiLODateTime resource describes the properties for managing the BMC data and time.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/datetime |
GET PATCH |
Link Name | Destination type |
---|---|
Links/EthernetNICs |
Collection of EthernetInterface |
Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
Description | The state of the currently displayed configuration settings. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Current |
SomePendingReset |
Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
Description | The date and time used by management processor. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
NTPServers
is an array containing elements of:
Description | The current NTP server's IPv4 address, IPv6 address, or FQDN. The value either comes from DHCP or is static depending on the DHCP settings. |
Type | string or null |
Read Only | True |
Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
Description | Determines whether the server time is synchronized with the management processor time during the first POST after AC power is applied. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
StaticNTPServers
is an array containing elements of:
Description | The static NTP server's IPv4 address, IPv6 address, or FQDN. To set this property, management processor must not be configured to use NTP servers provided by DHCPv4 or DHCPv6. |
Type | string |
Read Only | True |
TimeZone.Index Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
Description | The index of the current time zone. To set a new time zone, specify a different time zone index. This property can be set only when DHCPv4 or DHCPv6 supplied time settings are disabled. Since the time zone list might vary from one firmware version to another (which often leads to differences in time zone indices), setting the time zone by name is recommended over setting by index, for better compatibility. |
Type | number |
Read Only | False |
Added | iLO 5 1.10 |
TimeZone.UtcOffset Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
Description | The UTC offset of the current time zone, in the format {+/-}hh:mm |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
TimeZone.Value Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
Description | The environment variable value. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
TimeZoneList
is an array containing elements of:
TimeZoneList[{item}].Index Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
Description | The time zone index. |
Type | number |
Read Only | True |
Added | iLO 5 1.10 |
TimeZoneList[{item}].UtcOffset Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
Description | The UTC offset of the time zone, in the format {+/-}hh:mm |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
TimeZoneList[{item}].Value Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
Description | The environment variable value. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
@odata.type: "#HpeiLOEmbeddedMedia.v2_0_0.HpeiLOEmbeddedMedia"
The HpeiLOEmbeddedMedia resource describes the properties for the embedded media.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/embeddedmedia |
GET |
Controller.Firmware Controller.Firmware.Current Controller.Firmware.Current.VersionString Member of HpeiLOEmbeddedMedia.v2_0_0.HpeiLOEmbeddedMedia
Description | The current version of the embedded media controller. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Controller.Status Member of HpeiLOEmbeddedMedia.v2_0_0.HpeiLOEmbeddedMedia See the Redfish standard schema and specification for information on common Status object.
SDCard.SizeMB Member of HpeiLOEmbeddedMedia.v2_0_0.HpeiLOEmbeddedMedia
Description | The size of the SD card present in the server, in MB. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
SDCard.Status Member of HpeiLOEmbeddedMedia.v2_0_0.HpeiLOEmbeddedMedia See the Redfish standard schema and specification for information on common Status object.
@odata.type: "#HpeiLOFederatedGroupCapping.v2_0_0.HpeiLOFederatedGroupCapping"
The HpeiLOFederatedGroupCapping resource describes the properties for managing Federated Group Capping.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/power/federatedgroupcapping |
GET PATCH |
Member of HpeiLOFederatedGroupCapping.v2_0_0.HpeiLOFederatedGroupCapping
Description | The configured power cap for all servers in a group. This value is 0 if the power cap is not configured. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeiLOFederatedGroupCapping.v2_0_0.HpeiLOFederatedGroupCapping
Description | The total power supply capacity for all servers in a group. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeiLOFederatedGroupCapping.v2_0_0.HpeiLOFederatedGroupCapping
Description | High, Med, or Low based on the percentage of power usage. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
@odata.type: "#HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup"
The HpeiLOFederationGroup resource describes the properties for managing Federation groups.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/federationgroups/{item} |
GET PATCH DELETE |
Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | The password used by the Federation Group. |
Type | string or null |
Read Only | False |
Privileges.HostBIOSConfigPriv Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | Host BIOS configuration privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Privileges.HostNICConfigPriv Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | Host NIC configuration privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Privileges.HostStorageConfigPriv Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | Host Storage configuration privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Privileges.LoginPriv Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | Login privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Privileges.RemoteConsolePriv Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | Remote console privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Privileges.SystemRecoveryConfigPriv Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | System Recovery configuration privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Privileges.UserConfigPriv Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | User configuration privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Privileges.VirtualMediaPriv Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | Virtual media privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Privileges.VirtualPowerAndResetPriv Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | Virtual power and reset privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Privileges.iLOConfigPriv Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | The management processor configuration privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
@odata.type: "#HpeiLOFederationGroupCollection.HpeiLOFederationGroupCollection"
A Collection of HpeiLOFederationGroup resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/federationgroups |
GET POST |
Link Name | Destination type |
---|---|
Members[] |
HpeiLOFederationGroup |
Member of HpeiLOFederationGroupCollection.HpeiLOFederationGroupCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeiLOFederationGroupCollection.HpeiLOFederationGroupCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeiLOFederationGroupCollection.HpeiLOFederationGroupCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeiLOFederationPeers.v2_0_0.HpeiLOFederationPeers"
The HpeiLOFederationPeers resource describes the properties for viewing Federation peers.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/federationpeers/{item} |
GET |
Member of HpeiLOFederationPeers.v2_0_0.HpeiLOFederationPeers
Peers
is an array containing elements of:
Peers[{item}].HttpErrorCode Member of HpeiLOFederationPeers.v2_0_0.HpeiLOFederationPeers
Description | Error code for success or failure. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Peers[{item}].ManagerIPAddress Member of HpeiLOFederationPeers.v2_0_0.HpeiLOFederationPeers
Description | Manager IP address of the federation peer. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Peers[{item}].Time Member of HpeiLOFederationPeers.v2_0_0.HpeiLOFederationPeers
Description | Time when the federation peer was added. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
Peers[{item}].URL Member of HpeiLOFederationPeers.v2_0_0.HpeiLOFederationPeers
Description | URL of the federation peer. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | url |
Peers[{item}].UUID Member of HpeiLOFederationPeers.v2_0_0.HpeiLOFederationPeers
Description | UUID peers that are part of the federation group. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
@odata.type: "#HpeiLOFederationPeersCollection.HpeiLOFederationPeersCollection"
A Collection of HpeiLOFederationPeers resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/federationpeers |
GET |
Link Name | Destination type |
---|---|
Members[] |
HpeiLOFederationPeers |
Member of HpeiLOFederationPeersCollection.HpeiLOFederationPeersCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeiLOFederationPeersCollection.HpeiLOFederationPeersCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeiLOFederationPeersCollection.HpeiLOFederationPeersCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeiLOLicense.v2_3_0.HpeiLOLicense"
The HpeiLOLicense resource describes the properties for managing BMC licenses.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/licenseservice/{item} |
GET DELETE |
Confirmation.Code Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Confirmation service response code. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Confirmation.Message Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | User-friendly confirmation information for the current managment processor license. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Confirmation.Service Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Confirmation service URI. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Confirmation.Status Member of HpeiLOLicense.v2_3_0.HpeiLOLicense See the Redfish standard schema and specification for information on common Status object.
ConfirmationRequest.EON ConfirmationRequest.EON.License Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | The current license of this management processor. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
ConfirmationRequest.EON.LicenseKey Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | The license key installed on this management processor. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
ConfirmationRequest.EON.Quantity Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | The number of entitlements licensed. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
ConfirmationRequest.EON.State Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | The current licensing state and behavior of the management processor. This is affected by license installation, activation and confirmation. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
unlicensed |
standard baseline functionality |
evaluation |
evaluation / demonstration temporary licensed functionality |
nfr |
not for resale experimental functionality |
expired |
standard baseline functionality and evaluation licenses no longer accepted |
unconfirmed |
licensed functionality that has not been confirmed |
timeout |
licensed functionality is disabled until the license is confirmed |
confirmed |
licensed functionality has been confirmed for use |
static |
system has active built-in licensed functionality that does not require confirmation |
err |
error |
ConfirmationRequest.Signer Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Source of confirmation request. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
ConfirmationRequest.System ConfirmationRequest.System.ChipId Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Management processor unique chip identifier. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
ConfirmationRequest.System.Product Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | System housing management processor. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
ConfirmationRequest.System.SerialNumber Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | System serial number. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | The current license of this management processor. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | The class of current license on this management processor. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value |
---|
FQL |
BETA |
EVALUATION |
AKA |
DL |
FFQL |
SL |
SITE |
EVAL |
MLA |
Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Error information from the most recent attempt to alter the installed management processor license. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | User-friendly expiration information of the installed management processor license. For example, for demo license, Evaluation period 2 months 5 days 6 hours remain. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
LicenseFeatures.DirectoryAuth Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Directory integrated authentication. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
LicenseFeatures.DowngradePolicy Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Firmware downgrade policy setting. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.40 |
LicenseFeatures.EmailAlert Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Email based alerting. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
LicenseFeatures.FWScan Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Runtime FW Integrity check. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
LicenseFeatures.Federation Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Distributed peer to peer management. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
LicenseFeatures.Jitter Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Jitter Control. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
LicenseFeatures.KD Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Kernel Debugging (VSP raw mode). |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
LicenseFeatures.KeyMgr Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Store and retrieve keys from an external key manager. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
LicenseFeatures.MURC Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Shared Multi-User Remote Console. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
LicenseFeatures.ODIM Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Open Distributed Infrastructure Management. |
Type | boolean |
Read Only | True |
LicenseFeatures.PowerReg Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Power Regulator. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
LicenseFeatures.RC Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Graphical Remote Console. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
LicenseFeatures.Recovery Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | OS Recovery Event. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.17 |
LicenseFeatures.RemoteSyslog Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Remote Syslog. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
LicenseFeatures.Scrncap Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Video Capture. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
LicenseFeatures.SecureErase Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Secure Erase of embedded media. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
LicenseFeatures.SmartCard Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | 2-Factor Authentication (Smart Card). |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
LicenseFeatures.SuiteB Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | SuiteB/CNSA mode support. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
LicenseFeatures.TextCons Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Text Console. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
LicenseFeatures.VM Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Remote Console based Virtual Media. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
LicenseFeatures.VMScript Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Scripted Virtual Media. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
LicenseFeatures.VSPLogging Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Virtual Serial Port Logging and Playback. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | User-friendly installation date information of the installed management processor license. For example, 19 May 2017 |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | User-visible license key installed on this management processor. License keys are 25 or 29 characters and contain letters, numbers and hypens. Use POST method to collection of membertype HpeiLOLicense to install / update the license. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | The number of systems authorized to use this activation key. |
Type | integer |
Read Only | True |
Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | The licensed feature-set of the management processor. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
STD |
BLSTD |
ADV |
BLADV |
ESS |
SCALEOUT |
APSE |
Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | The type of current license activation on this management processor. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Unlicensed |
Evaluation |
Perpetual |
Subscription |
Internal |
Duration |
Expired |
@odata.type: "#HpeiLOLicenseCollection.HpeiLOLicenseCollection"
A Collection of HpeiLOLicense resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/licenseservice |
GET POST |
Link Name | Destination type |
---|---|
Members[] |
HpeiLOLicense |
Member of HpeiLOLicenseCollection.HpeiLOLicenseCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeiLOLicenseCollection.HpeiLOLicenseCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeiLOLicenseCollection.HpeiLOLicenseCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeiLOResourceDirectory.v2_0_0.HpeiLOResourceDirectory"
The HpeiLOResourceDirectory resource describes the resource directory. The resource directory is a selected set of resources and resource types for faster access to resources.
Uri | HTTP Allow |
---|---|
/redfish/v1/resourcedirectory |
GET |
Member of HpeiLOResourceDirectory.v2_0_0.HpeiLOResourceDirectory
Instances
is an array containing elements of:
Instances[{item}].@odata.id Member of HpeiLOResourceDirectory.v2_0_0.HpeiLOResourceDirectory
Type | string |
Read Only | True |
Format | uri-reference |
Instances[{item}].@odata.type Member of HpeiLOResourceDirectory.v2_0_0.HpeiLOResourceDirectory
Type | string |
Read Only | True |
Instances[{item}].ETag Member of HpeiLOResourceDirectory.v2_0_0.HpeiLOResourceDirectory
Description | This is the last known etag of the resource. The property is omitted if not known. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Instances[{item}].HttpMethods (array)
Member of HpeiLOResourceDirectory.v2_0_0.HpeiLOResourceDirectory
HttpMethods
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value |
---|
GET |
HEAD |
POST |
PUT |
PATCH |
DELETE |
Instances[{item}].MemberType Member of HpeiLOResourceDirectory.v2_0_0.HpeiLOResourceDirectory
Description | This property has the type of members for collection resources. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
@odata.type: "#HpeiLOSecurityDashboard.v1_0_0.HpeiLOSecurityDashboard"
The HpeiLOSecurityDashboard resource describes the BMC security dashboard.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/securityservice/securitydashboard |
GET |
Link Name | Destination type |
---|---|
SecurityParameters |
HpeiLOSecurityParam |
Member of HpeiLOSecurityDashboard.v1_0_0.HpeiLOSecurityDashboard
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Ok |
The Overall security state of the system is OK. |
Risk |
The Overall security state of the system is Risk. |
Ignored |
The user has ignored (or suppressed) the risk on all the security parameters (whose Status value is Risk). |
This property references a resource of type Collection with a MemberType of HpeiLOSecurityParam.
SecurityParameters is a link ("@odata.id": URI
) to another resource.
Member of HpeiLOSecurityDashboard.v1_0_0.HpeiLOSecurityDashboard
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
Server Configuration Lock is Enabled. |
Disabled |
Server Configuration Lock is Disabled. |
@odata.type: "#HpeiLOSecurityParam.v1_1_0.HpeiLOSecurityParam"
The HpeiLOSecurityParam resource describes the properties for BMC security dashboard parameters.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/securityservice/securitydashboard/securityparams/{item} |
GET |
Member of HpeiLOSecurityParam.v1_1_0.HpeiLOSecurityParam
Description | This indicates if the security status of the security parameter is set to ignored or not. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.40 |
Member of HpeiLOSecurityParam.v1_1_0.HpeiLOSecurityParam
Description | This represents the user who changed the value of Ignore. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
Member of HpeiLOSecurityParam.v1_1_0.HpeiLOSecurityParam
Description | This represents the time when the risk configuration was suppressed. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
Member of HpeiLOSecurityParam.v1_1_0.HpeiLOSecurityParam
Description | This represents the recommended action. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
Member of HpeiLOSecurityParam.v1_1_0.HpeiLOSecurityParam
Description | This represents if the status of the security parameter. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Risk |
This indicates a security issue associated with the security parameter. |
Ok |
This indicates no security issue associated with the security parameter. |
Member of HpeiLOSecurityParam.v1_1_0.HpeiLOSecurityParam
Description | This represents the state or value of the security parameter. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
On |
The state of the Security Parameter is On. |
Off |
The state of the Security Parameter is Off. |
Enabled |
The state of the Security Parameter is Enabled. |
Disabled |
The state of the Security Parameter is Disabled. |
Failed |
The status of the Security Parameter or the result of an operation represented by the Security Parameter is Failed. |
Ok |
The status of the Security Parameter or the result of an operation represented by the Security Parameter is Ok. |
Insufficient |
The value of the Security Parameter is Insufficient or less than the default value. |
Repaired |
The state of the Security Parameter is Repaired. |
True |
The state of the Security Parameter is True. |
False |
The state of the Security Parameter is False. |
@odata.type: "#HpeiLOSecurityParamCollection.HpeiLOSecurityParamCollection"
A Collection of HpeiLOSecurityParam resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/securityservice/securitydashboard/securityparams |
GET |
Link Name | Destination type |
---|---|
Members[] |
HpeiLOSecurityParam |
Member of HpeiLOSecurityParamCollection.HpeiLOSecurityParamCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeiLOSecurityParamCollection.HpeiLOSecurityParamCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeiLOSecurityParamCollection.HpeiLOSecurityParamCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService"
The HpeiLOSnmpService resource describes the properties for managing the SNMP configuration of the BMC.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/snmpservice |
GET POST PATCH |
Link Name | Destination type |
---|---|
SNMPUsers |
Collection of HpeSNMPUser |
SNMPAlertDestinations |
Collection of HpeSNMPAlertDestination |
Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
AlertDestinationAssociations
is an array containing elements of:
AlertDestinationAssociations[{item}].SNMPAlertProtocol Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
Description | Indicate the SNMP protocol associated with the AlertDestination. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
SNMPv1Trap |
Indicate SNMPv1 trap is enabled for the destination. |
SNMPv3Trap |
Indicate SNMPv3 trap is enabled for the destination. Needs to fill the SecurityName as well. |
SNMPv3Inform |
Indicate SNMPv3 Inform is enabled for the destination. Needs to fill the SecurityName as well. |
Null |
A value is temporarily unavailable |
AlertDestinationAssociations[{item}].SecurityName Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
Description | Provides the SNMPv3 security name associated with the destination when SNMP alert protocol is SNMPv3 trap or inform. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
AlertDestinations
is an array containing elements of:
Type | string or null |
Read Only | True |
Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
Description | The alert conditions that the management processor detects independently of the host operating system can be sent to specified SNMP alert destinations. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
Description | The string of up to 49 characters that specifies the system administrator or server owner. The string can include a name, email address, or phone number. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
Description | The string of up to 49 characters that specifies the physical location of the server. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
Description | If set to true, the Cold Start Trap will be enabled. The Cold Start Trap is broadcast to a subnet broadcast address if there are no trap destinations configured in the SNMP Alert Destination(s) boxes. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
Description | If there are any component in health status array(HSA) Trap are in degraded or failed condition then HSA trap will be sent periodically till the component status becomes ok or fine condition. This setting is disabled by default. |
Type | string |
Read Only | False |
Added | iLO 5 1.20 |
The following are the supported values:
Value |
---|
Disabled |
Daily |
Weekly |
Monthly |
Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
ReadCommunities
is an array containing elements of:
Type | string |
Read Only | True |
Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
Description | The string of up to 64 characters that describes the server role or function. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
Description | The string of up to 512 characters that describes specific tasks that the server might perform. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
SNMP Alert Destination details.
SNMPAlertDestinations is a link ("@odata.id": URI
) to another resource.
SNMPv3 User details.
SNMPUsers is a link ("@odata.id": URI
) to another resource.
Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
Description | When enabled, SNMPv1 traps are sent to the remote management systems configured in the SNMP Alert Destination(s) boxes. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
Description | The SNMPv3 Engine ID is the unique identifier of an SNMP engine that belongs to an SNMP agent entity. This value must be a hexadecimal string with an even number of 6 to 32 characters, excluding the first two characters, 0x (for example, 0x01020304abcdef). |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
Description | Specifies the number of retries to be used in SNMPv3 inform. |
Type | integer |
Read Only | False |
Added | iLO 5 1.20 |
Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
Description | Specifies the interval in seconds between SNMPv3 inform retries. |
Type | integer |
Read Only | False |
Added | iLO 5 1.20 |
Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService See the Redfish standard schema and specification for information on common Status object.
Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
TrapCommunities
is an array containing elements of:
Type | string |
Read Only | True |
Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
Description | Determines the host name that is used in the SNMP-defined sysName variable when the management processor generates SNMP traps. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Manager |
System |
Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
Users
is an array containing elements of:
Users[{item}].AuthPassphrase Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
Description | Sets the passphrase to use for sign operations. Enter a value of 8 to 49 characters. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
Users[{item}].AuthProtocol Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
Description | Sets the message digest algorithm to use for encoding the authorization passphrase. The message digest is calculated over an appropriate portion of an SNMP message, and is included as part of the message sent to the recipient. Select MD5 (Message Digest) or SHA (Secure Hash Algorithm). |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
MD5 |
Indicate Message Digest Algorithm. |
SHA |
Indicate Secure Hash Algorithm. |
SHA256 |
Indicate SHA256 Algorithm. |
Null |
A value is temporarily unavailable |
Users[{item}].PrivacyPassphrase Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
Description | Sets the passphrase to use for encrypt operations. Enter a value of 8 to 49 characters. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
Users[{item}].PrivacyProtocol Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
Description | Sets the encryption algorithm to use for encoding the privacy passphrase. A portion of an SNMP message is encrypted before transmission. Select AES (Advanced Encryption Standard) or DES (Data Encryption Standard). |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
AES |
Indicate Advanced Encryption Standard Algorithm. |
DES |
Indicate Data Encryption Standard Algorithm. |
Null |
A value is temporarily unavailable |
Users[{item}].SecurityName Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
Description | The user profile name. Enter an alphanumeric string of 1 to 32 characters. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
Users[{item}].UserEngineID Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService
Description | The UserEngineID is combined with the SecurityName to create a SNMPv3 user for each manager. It is only used for creating remote accounts used with INFORM messages. If this property is not set then INFORM message will be sent with default or iLO configured engine ID. This value must be a hexadecimal string with an even number of 10 to 64 characters, excluding the first two characters, 0x (for example, 0x01020304abcdef). |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
HpeiLOSnmpService.SendSNMPTestAlert Member of HpeiLOSnmpService.v2_2_0.HpeiLOSnmpService There are no parameters for this action.
@odata.type: "#HpeiLOSSO.v2_0_0.HpeiLOSSO"
The HpeiLOSSO resource describes the configuration of the HPE BMC single-sign-on trusted server feature.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/securityservice/sso |
GET POST PATCH |
Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
ManagerTrustedCertificates
is an array containing elements of:
ManagerTrustedCertificates[{item}].@odata.id Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Type | string |
Read Only | True |
Format | uri-reference |
ManagerTrustedCertificates[{item}].@odata.type Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Type | string |
Read Only | True |
ManagerTrustedCertificates[{item}].Certificate Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Contains PEM formatted X509 certificate (Base64 encoded). |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
ManagerTrustedCertificates[{item}].CertificateDetails ManagerTrustedCertificates[{item}].CertificateDetails.Issuer Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | The Certificate Authority that issued the certificate. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
ManagerTrustedCertificates[{item}].CertificateDetails.Subject Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | The entity to which the certificate was issued. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
ManagerTrustedCertificates[{item}].CertificateDetails.ValidNotAfter Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | The date on which the certificate validity period ends. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
ManagerTrustedCertificates[{item}].CertificateDetails.ValidNotBefore Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | The date on which the certificate validity period begins. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
ManagerTrustedCertificates[{item}].RecordType Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Specifies the type of SSO record imported. |
Type | string |
Read Only | true |
Added | iLO 5 1.15 |
The following are the supported values:
Value | Description |
---|---|
Certificate |
It is a PEM formatted X509 certificate (Base64 encoded). |
DNSName |
It is a DNS name or an IP address of the HPE SSO-compliant application. |
ManagerTrustedCertificates[{item}].SerialNumber Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Contains the Serial number for the SSO records. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
ManagerTrustedCertificates[{item}].ServerName Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | The Server name (or certificate subject). |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
ManagerTrustedCertificates[{item}].Status Member of HpeiLOSSO.v2_0_0.HpeiLOSSO See the Redfish standard schema and specification for information on common Status object.
SSOsettings.AdminPrivilege SSOsettings.AdminPrivilege.HostBIOSConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Host BIOS Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.AdminPrivilege.HostNICConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Host NIC Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.AdminPrivilege.HostStorageConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Host Storage Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.AdminPrivilege.LoginPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Login Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.AdminPrivilege.RemoteConsolePriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Remote Console Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.AdminPrivilege.SystemRecoveryConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | System Recovery Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.AdminPrivilege.UserConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | User Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.AdminPrivilege.VirtualMediaPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Virtual Media Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.AdminPrivilege.VirtualPowerAndResetPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Power and Reset Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.AdminPrivilege.iLOConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | iLO Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.OperatorPrivilege SSOsettings.OperatorPrivilege.HostBIOSConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Host BIOS Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.OperatorPrivilege.HostNICConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Host NIC Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.OperatorPrivilege.HostStorageConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Host Storage Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.OperatorPrivilege.LoginPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Login Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.OperatorPrivilege.RemoteConsolePriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Remote Console Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.OperatorPrivilege.SystemRecoveryConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | System Recovery Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.OperatorPrivilege.UserConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | User Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.OperatorPrivilege.VirtualMediaPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Virtual Media Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.OperatorPrivilege.VirtualPowerAndResetPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Power and Reset Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.OperatorPrivilege.iLOConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | iLO Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.SSOTrustMode Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Represents the SSO Trust Mode. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
TrustNone |
Rejects all SSO connection request. |
TrustAll |
Accepts any SSO connection initiated from any HPE SSO compliant application. |
TrustbyName |
Enables SSO connections from an HPE SSO compliant application by matching a directly imported IP address or DNS name. |
TrustbyCert |
Enables SSO connections from an HPE SSO compliant application by matching a certificate previously imported to iLO. |
SSOsettings.UserPrivilege SSOsettings.UserPrivilege.HostBIOSConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Host BIOS Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.UserPrivilege.HostNICConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Host NIC Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.UserPrivilege.HostStorageConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Host Storage Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.UserPrivilege.LoginPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Login Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.UserPrivilege.RemoteConsolePriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Remote Console Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.UserPrivilege.SystemRecoveryConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | System Recovery Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.UserPrivilege.UserConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | User Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.UserPrivilege.VirtualMediaPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Virtual Media Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.UserPrivilege.VirtualPowerAndResetPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Power and Reset Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SSOsettings.UserPrivilege.iLOConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | iLO Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
HpeiLOSSO.ImportDNSName Member of HpeiLOSSO.v2_0_0.HpeiLOSSO Add DNS Name to the record list.
Parameters:
DNSName (string)
DNS Name of the HPE SSO Trusted Server.
HpeiLOSSO.ImportCertificate Member of HpeiLOSSO.v2_0_0.HpeiLOSSO Import the HPE SSO Certificate.
Parameters:
CertInput (string)
PEM formatted X509 certificate (Base64 encoded)/DNS name or IP address to import the certificate.
CertType (string)
Specifies the type of certificate imported.
Value | Description |
---|---|
ImportCertUri | iLO imports the certificate from the HPE SSO compliant application over the network. |
DirectImportCert | iLO directly imports the Certificate. |
HpeiLOSSO.DeleteSSORecordbyNumber Member of HpeiLOSSO.v2_0_0.HpeiLOSSO Delete SSO record by record number.
Parameters:
RecordNumber (integer)
Index of the SSO record to be deleted.
HpeiLOSSO.DeleteAllSSORecords Member of HpeiLOSSO.v2_0_0.HpeiLOSSO Delete all the SSO records.
There are no parameters for this action.
@odata.type: "#HpeInvalidImage.v1_0_0.HpeInvalidImage"
The HpeInvalidImage resource describes the properties of an invalid firmware image detected and preserved from a computer system.
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/invalidimagerepository/{item} |
GET POST PATCH DELETE |
Member of HpeInvalidImage.v1_0_0.HpeInvalidImage
Description | ISO 8601 time string indicating when this image was added to the NAND. |
Type | string |
Read Only | True |
Added | iLO 5 1.30 |
Format | date-time |
Member of HpeInvalidImage.v1_0_0.HpeInvalidImage
Description | Device type GUID from iLO secure flash header |
Type | string |
Read Only | True |
Added | iLO 5 1.30 |
Member of HpeInvalidImage.v1_0_0.HpeInvalidImage
Description | The unique filename of the image. |
Type | string |
Read Only | True |
Added | iLO 5 1.30 |
Member of HpeInvalidImage.v1_0_0.HpeInvalidImage
Description | Path of file on the USB LUN if the repo is mounted as USB. |
Type | string |
Read Only | True |
Added | iLO 5 1.30 |
Member of HpeInvalidImage.v1_0_0.HpeInvalidImage
Description | URI of the image binary. |
Type | string |
Read Only | True |
Added | iLO 5 1.30 |
Format | uri-reference |
Member of HpeInvalidImage.v1_0_0.HpeInvalidImage
Description | Size of the image file in bytes. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.30 |
@odata.type: "#HpeInvalidImageCollection.HpeInvalidImageCollection"
A Collection of HpeInvalidImage resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/invalidimagerepository |
GET POST |
Link Name | Destination type |
---|---|
Members[] |
HpeInvalidImage |
Member of HpeInvalidImageCollection.HpeInvalidImageCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeInvalidImageCollection.HpeInvalidImageCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeInvalidImageCollection.HpeInvalidImageCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator"
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/bios/iscsi |
GET |
/redfish/v1/systems/{item}/bios/iscsi/settings |
GET PATCH |
Link Name | Destination type |
---|---|
@Redfish.Settings/SettingsObject |
HpeiSCSISoftwareInitiator |
Oem/Hpe/Links/BaseConfigs |
HpeBaseConfigs |
Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator See the Redfish standard schema and specification for information on common @Redfish properties.
Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The worldwide unique iSCSI Qualified Name (IQN) of this iSCSI Initiator. Only IQN format is accepted. EUI format is not supported (for example, 'iqn.1986-03.com.hp:init.sn-123456'). |
Type | string |
Read Only | True |
Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
iSCSINicSources
is an array containing elements of:
Description | The BIOS Attribute that describes a NIC instance that can be used as a target for iSCSI configuration. |
Type | string |
Read Only | True |
Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
iSCSISources
is an array containing elements of:
iSCSISources[{item}].StructuredBootString Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | Identifies this iSCSI option within the server. |
Type | string or null |
Read Only | True |
iSCSISources[{item}].UEFIDevicePath Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | Standardized text representation of the UEFI device path for this option, in UTF-8 format. |
Type | string or null |
Read Only | True |
iSCSISources[{item}].iSCSIAttemptInstance Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | Uniquely identifies this iSCSI attempt within iSCSISources array. If set to zero, all other properties in the boot option object are ignored (which will delete an existing boot attempt). |
Type | integer |
Read Only | True |
iSCSISources[{item}].iSCSIAttemptName Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | Human readable descriptive name for this iSCSI attempt configuration |
Type | string or null |
Read Only | True |
iSCSISources[{item}].iSCSIAuthenticationMethod Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The iSCSI connection authentication method. |
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
None |
No iSCSI connection security. |
CHAP |
iSCSI connection is secured using Challenge Handshake Authentication Protocol (CHAP). |
iSCSISources[{item}].iSCSIChapSecret Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The password needed for CHAP authentication. This is applicable only when the Authentication Method is set to CHAP, and the CHAP Type is set to Mutual. |
Type | string or null |
Read Only | True |
iSCSISources[{item}].iSCSIChapType Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The CHAP authentication type. This is applicable only when the Authentication Method is set to CHAP. |
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
OneWay |
The target will authenticate the initiator. . |
Mutual |
both the initiator and target will authenticate each other. |
iSCSISources[{item}].iSCSIChapUsername Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The password needed for CHAP authentication. This is applicable only when the Authentication Method is set to CHAP. |
Type | string or null |
Read Only | True |
iSCSISources[{item}].iSCSIConnectRetry Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The number of times to retry the iSCSI connection. Zero means no retries. |
Type | integer |
Read Only | True |
iSCSISources[{item}].iSCSIConnectTimeoutMS Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The iSCSI connection timeout value in milliseconds. |
Type | integer |
Read Only | True |
iSCSISources[{item}].iSCSIConnection Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | Enables or Disables iSCSI mode for a selected iSCSI attempt. |
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Disabled |
Connecting to this iSCSI attempt is disabled. |
Enabled |
Connecting to this iSCSI attempt is enabled. |
EnabledMpio |
Connecting to this iSCSI attempt is enabled with MPIO (Multi Path I/O). |
iSCSISources[{item}].iSCSIInitiatorGateway Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The gateway address of the iSCSI Initiator, if not configured via DHCP. The address must be an IPv4 or IPv6 address, depending on the IP Address Type. |
Type | string |
Read Only | True |
iSCSISources[{item}].iSCSIInitiatorInfoViaDHCP Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | If enabled, the iSCSI Initiator information is configured from DHCP. Otherwise, the iSCSI initiator information must be statically configured. When providing static values for the Initiator, ensure Target settings are also configured with static values. |
Type | boolean |
Read Only | True |
iSCSISources[{item}].iSCSIInitiatorIpAddress Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The IP Address of the iSCSI Initiator, if not configured via DHCP. The Initiator IP Address is always auto-assigned if IP address type is IPv6. The address must be an IPv4 or IPv6 address, depending on the IP Address Type. |
Type | string |
Read Only | True |
iSCSISources[{item}].iSCSIInitiatorNetmask Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The subnet mask of the iSCSI Initiator, if not configured via DHCP. The address must be an IPv4. |
Type | string |
Read Only | True |
iSCSISources[{item}].iSCSIIpAddressType Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The iSCSI IP Address type. If set to Auto, IPv4 will be attempted first, followed by IPv6. |
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
IPv4 |
The iSCSI IP address is configured in IPv4 format. |
IPv6 |
The iSCSI IP address is configured in IPv6 format. |
Auto |
The iSCSI IP address is configured in IPv4. If an issue occurs with IPv4, then the IPv6 configuration is used. |
iSCSISources[{item}].iSCSILUN Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The iSCSI target Logical Unit Number (LUN), if not obtained from DHCP. This value must follow the SAM-2 spec. E.g. 0001-1234-5678-9ABC. If the digit number is less then 5 characters, a dash character is not required. E.g. 0001. If the lun number is 12345, input 1234-5 |
Type | string |
Read Only | True |
iSCSISources[{item}].iSCSINicSource Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | A BIOS Attribute that describes this selected NIC instance. This must match one of the possible values listed in the iSCSINicSources array. |
Type | string or null |
Read Only | True |
iSCSISources[{item}].iSCSIReverseChapSecret Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The password needed for reverse CHAP authentication (from the target to the initiator). This is applicable only when the Authentication Method is set to CHAP, and the CHAP Type is set to Mutual. |
Type | string or null |
Read Only | True |
iSCSISources[{item}].iSCSIReverseChapUsername Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | User Name for reverse CHAP authentication (from the target to the initiator). This is applicable only when the Authentication Method is set to CHAP, and the CHAP Type is set to Mutual. |
Type | string or null |
Read Only | True |
iSCSISources[{item}].iSCSITargetInfoViaDHCP Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | If enabled, the iSCSI target information are configured from DHCP. Otherwise, the iSCSI target information must be statically configured. |
Type | boolean |
Read Only | True |
iSCSISources[{item}].iSCSITargetIpAddress Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The IP Address of the iSCSI Target, if not obtained from DHCP. The address must be an IPv4 or IPv6 address, depending on the IP Address Type. |
Type | string |
Read Only | True |
iSCSISources[{item}].iSCSITargetName Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The worldwide unique iSCSI Qualified Name (IQN) of this iSCSI target. Only the IQN format is accepted. EUI format is not supported (for example, 'iqn.1991-05.com.microsoft:iscsitarget-iscsidisk-target'). |
Type | string or null |
Read Only | True |
iSCSISources[{item}].iSCSITargetTcpPort Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The iSCSI Target TCP Port number, if not obtained from DHCP. |
Type | integer |
Read Only | True |
@odata.type: "#HpeMaintenanceWindow.v1_0_1.HpeMaintenanceWindow"
The HpeMaintenanceWindow resource describes the properties for managing the time window for a software or firmware update task or install set.
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/maintenancewindows/{item} |
GET POST PATCH DELETE |
Member of HpeMaintenanceWindow.v1_0_1.HpeMaintenanceWindow
Description | ISO-time of maintenance window creation (by whomever created this thing) |
Type | string |
Read Only | True |
Added | iLO 5 1.30 |
Format | date-time |
Member of HpeMaintenanceWindow.v1_0_1.HpeMaintenanceWindow
Description | ISO 8601 Redfish-style time string after which we will automatically change state to Expired - null for no expire time |
Type | string |
Read Only | False |
Added | iLO 5 1.30 |
Format | date-time |
Member of HpeMaintenanceWindow.v1_0_1.HpeMaintenanceWindow
Description | ISO-time of last maintenance window item update by updater (not client) |
Type | string |
Read Only | True |
Added | iLO 5 1.30 |
Format | date-time |
Member of HpeMaintenanceWindow.v1_0_1.HpeMaintenanceWindow
Description | ISO 8601 Redfish-style time string of earliest execution. |
Type | string |
Read Only | False |
Added | iLO 5 1.30 |
Format | date-time |
@odata.type: "#HpeMaintenanceWindowCollection.HpeMaintenanceWindowCollection"
A Collection of HpeMaintenanceWindow resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/maintenancewindows |
GET POST |
Link Name | Destination type |
---|---|
Members[] |
HpeMaintenanceWindow |
Member of HpeMaintenanceWindowCollection.HpeMaintenanceWindowCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeMaintenanceWindowCollection.HpeMaintenanceWindowCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeMaintenanceWindowCollection.HpeMaintenanceWindowCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB"
The HpeNetworkPortEVB resource describes the Hewlett Packard Enterprise property extensions for Network Ports Edge Virtual Bridging
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/networkadapters/{item}/networkports/{item}/hpeevb |
GET |
/redfish/v1/systems/{item}/networkinterfaces/{item}/networkports/{item}/hpeevb |
GET |
Receiving.CdcpActive Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | True if a currently active IEEE 802.1Qbg CDCP TLV has been received from the link partner. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.ChannelActive Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | A currently unexpired HPE Channel Link Control or HPE Channel Description TLV has been received from the link partner. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.ChannelDescriptionLocalSequenceNumber Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | The link partner's HPE Channel Description sequence number that was last successfully received and processed. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.ChannelDescriptionRemoteSequenceNumber Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | The last HPE Channel Decsription sequence number sent on this link that was successfully received and processed by the link partner. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.ChannelDescriptionSubtype Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | The header subtype field of the last received HPE Channel Description TLV. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.ChannelLinkControlLocalSequenceNumber Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | The link partner's HPE Channel Link Control sequence number that was last successfully received and processed. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.ChannelLinkControlMCEnable Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | The Feature Indicators field, Management Controller (MC) Channel (SCID 4094) enabled state in the HPE CLC TLV being received from the link partner on this port. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.ChannelLinkControlRemoteSequenceNumber Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | The last HPE Channel Link control sequence number sent on this link that was successfully received and processed by the link partner. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.ChannelLinkControlSubtype Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | The header subtype field of the last received HPE Channel Link Control TLV. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.Role Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | The link partner's IEEE 802.1Qbg operating role. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
bridge |
Indicates the link partner is operating as a Bridge. |
station |
Indicates the link partner is operating as a Station. |
Receiving.SChannelAssignments (array)
Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
SChannelAssignments
is an array containing elements of:
SChannelAssignments[{item}].Scid Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | SCID value for this <SCID,SVID> S-Channel identifier pairreceived from the link partner on this port. |
Type | integer or null |
Read Only | True |
SChannelAssignments[{item}].Svid Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | SVID assignment value for this <SCID,SVID> S-Channel identifier pair received from the link partner on this port. When 0 it indicates an assignment request is in progress. |
Type | integer or null |
Read Only | True |
Receiving.SChannelMaxCount Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | Indicates the number of S-Channels the link partner can support on this physical link. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.SChannelsSupported Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | When true this link supports S-Channels. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.VirtualLinkStatusVector Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | A bit vector indicating S-Channel status received from the link partner, 1=up, 0=down. S-Channel status bits are ordered by SCID from lowest numbered (first) to highest (last). |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Transmitting.ChannelDescriptionData (array)
Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
ChannelDescriptionData
is an array containing elements of:
ChannelDescriptionData[{item}].Descriptor0BandwidthCirMbps Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | The bandwidth Commited Information Rate (CIR) for this S-Channel, in Mbps. |
Type | integer or null |
Read Only | True |
ChannelDescriptionData[{item}].Descriptor0BandwidthPirMbps Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | The bandwidth Peak Information Rate (PIR) for this S-Channel, in Mbps. |
Type | integer or null |
Read Only | True |
ChannelDescriptionData[{item}].Descriptor0ChannelTerminationType Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | Indicates the termination provided for this S-Channel. |
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
primary-physical |
This S-Channel is presented to the host OS as a primary PCI physical function. |
SR-IOV-virtual |
This S-Channel is presented to the host OS as a PCI SR-IOV virtual function. |
secondary-physical |
This S-Channel is presented to the host OS as a secondary PCI physical function, i.e. a PCI physical function behind a bridge on the device. |
vSwitch-port |
This S-Channel is mapped to a Virtual Switch port. |
NCSI-port |
This S-Channel is mapped to the NCSI internal port for management. |
ChannelDescriptionData[{item}].Descriptor0EthernetSupport Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | When true, this S-Channel supports Ethernet. |
Type | boolean or null |
Read Only | True |
ChannelDescriptionData[{item}].Descriptor0FCoESupport Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | When true, this S-Channel supports Fibre Channel over Ethernet (FCoE). |
Type | boolean or null |
Read Only | True |
ChannelDescriptionData[{item}].Descriptor0PcpSupport Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | Indicates which IEEE 802.1Q Ethernet Priority Code Point (PCP) classes are supported on this S-Channel. When no PCPs are supported, the S-Channel makes no attempt to filter or control traffic class. A string of 1/0 characters indicating 1=enabled, 0=disabled. PCP classes are ordered from highest numbered 7 (first) to lowest 0 (last). |
Type | string or null |
Read Only | True |
ChannelDescriptionData[{item}].Descriptor0RoCEESupport Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | When true, this S-Channel supports RDMA over Converged Enhanced Ethernet (RoCEE). |
Type | boolean or null |
Read Only | True |
ChannelDescriptionData[{item}].Descriptor0Scid Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | The S-Channel identifier for this Descriptor0 instance. |
Type | integer or null |
Read Only | True |
ChannelDescriptionData[{item}].Descriptor0iSCSISupport Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | When true, this S-Channel supports Internet SCSI (iSCSI). |
Type | boolean or null |
Read Only | True |
ChannelDescriptionData[{item}].Descriptor1ConnectionID Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | A unique S-Channel identifer in UUID format. |
Type | string or null |
Read Only | True |
ChannelDescriptionData[{item}].Descriptor1Scid Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | The S-Channel identifier for this Descriptor1 instance. |
Type | integer or null |
Read Only | True |
Transmitting.ChannelDescriptionLocalSequenceNumber Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | This station's channel discovery local sequence number which will be transmitted to the link partner on this port. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Transmitting.ChannelDescriptionRemoteSequenceNumber Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | The link partner's channel discovery local sequence number that was last successfully received and processed. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Transmitting.ChannelDescriptorCount Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | The number of channel descriptor pairs being transmitted to the link partner on this port. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Transmitting.ChannelLinkControlLocalSequenceNumber Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | This station's channel link control local sequence number which will be transmitted to the link partner on this port. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Transmitting.ChannelLinkControlMCEnable Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | The Feature Indicators field, Management Controller (MC) Channel (SCID 4094) enabled state in the HPE CLC TLV being transmitted to the link partner on this port. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Transmitting.ChannelLinkControlRemoteSequenceNumber Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | The link partner's channel link control local sequence number that was last successfully received and processed. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Transmitting.Role Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | This port's IEEE 802.1Qbg role being advertised on the link. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
bridge |
Indicates this link is operating locally as a Bridge. |
station |
Indicates this link is operating locally as a Station. |
Transmitting.SChannelAssignments (array)
Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
SChannelAssignments
is an array containing elements of:
SChannelAssignments[{item}].Scid Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | SCID value for this <SCID,SVID> S-Channel identifier pair being transmitted to the link partner on this port. |
Type | integer or null |
Read Only | True |
SChannelAssignments[{item}].Svid Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | SVID assignment value for this <SCID,SVID> S-Channel identifier pair being transmitted to the link partner on this port. When 0 it indicates an SVID assignment request to the link partner is in progress. |
Type | integer or null |
Read Only | True |
Transmitting.SChannelMaxCount Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | The Channel Capacity value being advertised to the link partner. It indicates the number of S-Channels this station can support on this physical link. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Transmitting.SChannelsSupported Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | When true, indicates that this physical link has S-Channel capability. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Transmitting.VirtualLinkStatusVector Member of HpeNetworkPortEVB.v1_1_1.HpeNetworkPortEVB
Description | A bit vector indicating S-Channel status being transmitted on this link, 1=up, 0=down. S-Channel status bits are ordered by SCID from lowest numbered (first) to highest (last). |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
@odata.type: "#HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP"
The HpeNetworkPortLLDP resource describes the Hewlett Packard Enterprise property extensions for Network Ports Link Layer Discovery Protocol
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/networkadapters/{item}/networkports/{item}/hpelldp |
GET |
/redfish/v1/systems/{item}/networkinterfaces/{item}/networkports/{item}/hpelldp |
GET |
Receiving.ChassisID Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | The LLDP chassis ID received from the link partner. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.ChassisIDSubtype Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | The IEEE 802.1AB-2009 chassis ID subtype received from the link partner. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
chassisComp |
Chassis component, based in the value of entPhysicalAlias in IETF RFC 4133. |
ifAlias |
Interface alias, based on the ifAlias MIB object. |
portComp |
Port component, based in the value of entPhysicalAlias in IETF RFC 4133. |
mac-Addr |
MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802. |
networkAddr |
Network address, based on an agent detected network address. |
ifName |
Interface name, based on the ifName MIB object. |
agent-ID |
Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC 3046. |
local-Assign |
Locally assigned, based on a alpha-numeric value locally assigned. |
Receiving.Dcb Receiving.Dcb.ApplicationPriorityReceived Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | True when an unexpired Data Center Bridging (DCB) Application Priority Table TLV has been received. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.Dcb.ApplicationPriorityTable (array)
Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
ApplicationPriorityTable
is an array containing elements of:
ApplicationPriorityTable[{item}].ApplicationPriority Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | Indicates which priority level is assigned for this application protocol. |
Type | integer or null |
Read Only | True |
ApplicationPriorityTable[{item}].ApplicationProtocol Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | An integer value indicating application protocol identity, of the type described by DCBApplicationSelect. |
Type | integer or null |
Read Only | True |
ApplicationPriorityTable[{item}].ApplicationSelect Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | Indentifies the type of the DCBApplicationProtocol property. |
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
reserved |
Reserved select value. |
default-Ethertype |
Default priority. Use when priority not otherwise specified. |
TCP-SCTP |
DCBApplicationProtocol value is a well known port over TCP or SCTP. |
UDP-DCCP |
DCBApplicationProtocol value is a well known port over UDP or DCCP. |
TCP-SCTP-UDP-DCCP |
DCBApplicationProtocol is a well known port over TCP, SCTP, SCTP, or DCCP. |
Receiving.Dcb.Ets
Receiving.Dcb.Ets.BandwidthAssignmentTable (array)
Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
BandwidthAssignmentTable
is an array containing elements of:
Description | One entry in the DCB ETS Traffic Class (TC) Bandwidth Assignment Table. |
Type | integer or null |
Read Only | True |
Receiving.Dcb.Ets.CreditBasedShaper Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | True if the link partner supports the Credit-based Shaper (CBS) transmmission selection algortithm. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.Dcb.Ets.MaximumTrafficClassCount Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | The maximum number of traffic classes supported by the link partner. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.Dcb.Ets.PriorityAssignmentTable (array)
Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
PriorityAssignmentTable
is an array containing elements of:
Description | One entry in the DCB ETS Priority Assignment Table indicating this priority's Traffic Class assignment. |
Type | integer or null |
Read Only | True |
Receiving.Dcb.Ets.TlvReceived Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | True when an unexpired DCB Enhanced Transmission Selection (ETS) TLV has been received. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.Dcb.Ets.TrafficSelectionAlgorithmTable (array)
Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
TrafficSelectionAlgorithmTable
is an array containing elements of:
Description | An assignment of a Traffic Selection Algorithm (TSA) to a traffic class. |
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
strict |
Strict priority algorithm. |
CBS |
Credit-Based Shaper algorithm. |
ETS |
Enhanced Traffic Selection algorithm. |
vendor |
Vendor specific algorithm for use with DCB. |
Receiving.Dcb.Ets.Willing Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | True if the link partner is willing to accept ETS configurations. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.Dcb.LocalEqualRemote Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | True when the transmitted and received contents match for both DCB ETS and PFC TLVs. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.Dcb.Pfc Receiving.Dcb.Pfc.EnabledTrafficClasses Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | A bit string indicating which priority levels have PFC enabled, 1=enabled. PFC levels are bit ordered from 7 (first) to 0 (last). |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.Dcb.Pfc.MacSecurityBypassCapability Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | True when the link partner has the ability to bypass MAC security in order to improve PFC responsiveness. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.Dcb.Pfc.MaximumTrafficClassCount Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | Indicates the maximum number of traffic classes that the link partner can simultaneously support. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.Dcb.Pfc.TlvReceived Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | True when an unexpired DCB Priority Flow Control (PFC) TLV has been received. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.Dcb.Pfc.Willing Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | True if the LLDP link partner is willing to accept PFC configurations. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.Dcb.Version Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | The DCB version supported by the link partner. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
unknown |
Unknown |
CEE |
Converged Enhanced Ethernet |
IEEE |
IEEE 802.1Q |
Receiving.ManagementAddress Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | The management address received from the link partner. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.ManagementAddressOID Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | An object identifier for the hardware or protocol entity associated with the management address. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.ManagementAddressReceived Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | True when a currently unexpired management address TLV has been received from the link partner. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.ManagementAddressType Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | The type of management address received from the link partner. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
IPv4 |
Type 1 (IP version 4). |
IPv6 |
Type 2 (IP version 6). |
all802 |
Type 6 (All 802 media plus Ethernet 'canonical format'). |
Receiving.ManagementCvlanID Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | The management CVLAN ID received from the link partner. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.ManagementIFNumSubtype Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | Management interface number subtype. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
unknown |
Interface number is not known. |
ifIndex |
Interface number is based on the ifIndex MIB object. |
sysPortNum |
Interface number is based on the system port numbering convention. |
Receiving.ManagementIFNumber Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | Management interface number received from the link partner represented as a colon delimited string of hexadecimal octets. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.ManagementVlanReceived Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | True when a currently unexpired management address VID TLV has been received from the link partner. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.NearestBridgeTtlExpired Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | True when the LLDP PDU most recently received from the link partner has expired. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.PortDescription Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | The remote link partner's port description. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.PortID Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | A colon delimited string of hexadecimal octets received from the link partner identifying its port. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Receiving.PortIDSubtype Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | The port ID subtype enumeration from IEEE 802.1AB-2009 Table 8-3, which indicates the format for the PortID property. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
chassisComp |
Chassis component, based in the value of entPhysicalAlias in IETF RFC 4133. |
ifAlias |
Interface alias, based on the ifAlias MIB object. |
portComp |
Port component, based in the value of entPhysicalAlias in IETF RFC 4133. |
mac-Addr |
MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802. |
networkAddr |
Network address, based on an agent detected network address. |
ifName |
Interface name, based on the ifName MIB object. |
agent-ID |
Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC 3046. |
local-Assign |
Locally assigned, based on a alpha-numeric value locally assigned. |
Receiving.SystemDescription Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | The system description received from the link partner. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Transmitting.ChassisID Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | The Link Layer Data Protocol (LLDP) chassis ID being transmitted on this link. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Transmitting.ChassisIDSubtype Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | The IEEE 802.1AB-2009 chassis ID subtype being transmitted on this link. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
chassisComp |
Chassis component, based in the value of entPhysicalAlias in IETF RFC 4133. |
ifAlias |
Interface alias, based on the ifAlias MIB object. |
portComp |
Port component, based in the value of entPhysicalAlias in IETF RFC 4133. |
mac-Addr |
MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802. |
networkAddr |
Network address, based on an agent detected network address. |
ifName |
Interface name, based on the ifName MIB object. |
agent-ID |
Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC 3046. |
local-Assign |
Locally assigned, based on a alpha-numeric value locally assigned. |
Transmitting.ManagementAddresses (array)
Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
ManagementAddresses
is an array containing elements of:
ManagementAddresses[{item}].ManagementIPAddress Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | A management address. |
Type | string or null |
Read Only | True |
ManagementAddresses[{item}].ManagementIPAddressType Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | The IANA type of this management address. |
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
IPv4 |
Type 1 (IP version 4). |
IPv6 |
Type 2 (IP version 6). |
all802 |
Type 6 (All 802 media plus Ethernet 'canonical format'). |
Transmitting.ManagementCvlanID Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | The management CVLAN ID being transmitted on this link. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Transmitting.ManagementCvlanIDTransmitted Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | When true, indicates that a management CVLAN ID is being transmitted on this link. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Transmitting.PortDescription Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | An alphanumeric string describing this link. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Transmitting.PortID Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | A colon delimited string of hexadecimal octets identifying this port. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Transmitting.PortIDSubtype Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | The port ID subtype from IEEE 802.1AB-2009 Table 8-3. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
chassisComp |
Chassis component, based in the value of entPhysicalAlias in IETF RFC 4133. |
ifAlias |
Interface alias, based on the ifAlias MIB object. |
portComp |
Port component, based in the value of entPhysicalAlias in IETF RFC 4133. |
mac-Addr |
MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802. |
networkAddr |
Network address, based on an agent detected network address. |
ifName |
Interface name, based on the ifName MIB object. |
agent-ID |
Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC 3046. |
local-Assign |
Locally assigned, based on a alpha-numeric value locally assigned. |
Transmitting.SystemDescription Member of HpeNetworkPortLLDP.v1_1_1.HpeNetworkPortLLDP
Description | A textual description of this system. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
@odata.type: "#HpePowerMeter.v2_0_1.HpePowerMeter"
The HpePowerMeter resource contains the computer system power history logged by the BMC.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/power/fastpowermeter |
GET |
/redfish/v1/chassis/{item}/power/powermeter |
GET |
Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Average power across all samples, over the last 24 hours. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Maximum power across all samples, taken from the 24 hour history. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Minimum power across all samples, taken from the 24 hour history. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpePowerMeter.v2_0_1.HpePowerMeter
PowerDetail
is an array containing elements of:
PowerDetail[{item}].AmbTemp Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Ambient temperature, in degrees Celsius. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
PowerDetail[{item}].Average Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Average power in Watts over the sample time. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
PowerDetail[{item}].Cap Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | The applicable power cap in Watts at the time of this power sample. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
PowerDetail[{item}].CpuAvgFreq Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | CPU average frequency in MHz. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
PowerDetail[{item}].CpuCapLim Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Measures the effect of the power cap on performance in percent. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
PowerDetail[{item}].CpuMax Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | The percentage of time the CPU spent in its maximum power mode. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
PowerDetail[{item}].CpuPwrSavLim Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Measures the effect of CPU Power Regulator state switching on performance in percent. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
PowerDetail[{item}].CpuUtil Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | CPU utilization in percent. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
PowerDetail[{item}].CpuWatts Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | The power consumed by the system CPUs in Watts. |
Type | integer |
Read Only | True |
Added | iLO 5 1.30 |
PowerDetail[{item}].DimmWatts Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | The power consumed by the system memory DIMMs in Watts. |
Type | integer |
Read Only | True |
Added | iLO 5 1.30 |
PowerDetail[{item}].GpuWatts Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | The power consumed by the GPU(s) in Watts. This will be 0 if no GPUs are installed or if the drivers are not loaded. |
Type | integer |
Read Only | True |
Added | iLO 5 1.30 |
PowerDetail[{item}].Minimum Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Minimum power in Watts over the sample time. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
PowerDetail[{item}].Peak Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Peak power in Watts over the sample time. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
PowerDetail[{item}].PrMode Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Power Regulator mode, which can be OS Control, Static High, Static Low or Dynamic. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
dyn |
Dynamic Mode - CPU power regulation is managed dynamically by the firmware. |
min |
Minimum Mode - CPU power regulation is configured to save as much power as possible at the possible expense of performance. |
max |
Maximum Mode - CPU power regulation is configured for maximum performance at the possible expense of power efficiency. |
osc |
OS Control Mode - CPU power regulation is managed by the Operating System. |
PowerDetail[{item}].PunCap Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | If true, CPU performance is being penalized by the current power cap. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
PowerDetail[{item}].Time Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Time at which the power sample detail was captured. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
PowerDetail[{item}].UnachCap Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | If true, the configured power cap could not be achieved due to system power requirements. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Number of samples in the array. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
@odata.type: "#HpeRemoteSupport.v2_4_0.HpeRemoteSupport"
The HpeRemoteSupport resource describes the properties for management of HPE Embedded Report Support.
This resource type was added in iLO 5 1.20
HpeRemoteSupport enables management of HPE Remote Support configuration on iLO 5.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/remotesupportservice |
GET POST PATCH |
Link Name | Destination type |
---|---|
ServiceEventLogs |
Collection of LogEntry |
Member of HpeRemoteSupport.v2_4_0.HpeRemoteSupport
Description | The Remote Support connect model type. |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value |
---|
DirectConnect |
CentralConnect |
Member of HpeRemoteSupport.v2_4_0.HpeRemoteSupport
Description | The frequency of data collection in days. This is applicable only when the server is registered using Direct Connect. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
Member of HpeRemoteSupport.v2_4_0.HpeRemoteSupport
Description | The port number of the Insight Remote Support server. This is applicable for Central Connect only. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
Member of HpeRemoteSupport.v2_4_0.HpeRemoteSupport
Description | The host name or IP address of the Remote Support server. This is applicable for Central Connect only. |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
Member of HpeRemoteSupport.v2_4_0.HpeRemoteSupport
Description | HPE Passport Account Password. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Member of HpeRemoteSupport.v2_4_0.HpeRemoteSupport
Description | HPE Passport Account Id. |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
Member of HpeRemoteSupport.v2_4_0.HpeRemoteSupport
Description | The last transmission date. |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
Format | date-time |
Member of HpeRemoteSupport.v2_4_0.HpeRemoteSupport
Description | The last transmission error. |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
Member of HpeRemoteSupport.v2_4_0.HpeRemoteSupport
Description | The last transmission type. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value |
---|
ActiveHealthSystemData |
L2DataCollection |
Registration |
Deregistration |
ServiceEvent |
NoTransmission |
Null |
Member of HpeRemoteSupport.v2_4_0.HpeRemoteSupport
Description | This indicates if the server is in Maintenance Mode or not. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.30 |
Member of HpeRemoteSupport.v2_4_0.HpeRemoteSupport
Description | This indicates the time remaining in minutes for the server to be in the maintenance mode. |
Type | integer |
Read Only | True |
ProxySettings.Password Member of HpeRemoteSupport.v2_4_0.HpeRemoteSupport
Description | Password for web proxy server authentication. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
ProxySettings.Port Member of HpeRemoteSupport.v2_4_0.HpeRemoteSupport
Description | Port number on which to communicate with the web proxy server. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.20 |
ProxySettings.Url Member of HpeRemoteSupport.v2_4_0.HpeRemoteSupport
Description | Web proxy server host name or IP address. |
Type | string |
Read Only | False |
Added | iLO 5 1.20 |
Format | url |
ProxySettings.Username Member of HpeRemoteSupport.v2_4_0.HpeRemoteSupport
Description | Username for web proxy server authentication. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
Member of HpeRemoteSupport.v2_4_0.HpeRemoteSupport
Description | This indicates if the Remote Support Service is available or not. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
A reference to the collection of service event logs.
ServiceEventLogs is a link ("@odata.id": URI
) to another resource.
HpeRemoteSupport.RegisterDeviceToRemoteSupport Member of HpeRemoteSupport.v2_4_0.HpeRemoteSupport
Parameters:
WebProxyUrl (string)
Web proxy server host name or IP address when connecting using Direct Connect.
DestinationUrl (string)
The host name or IP address of the Remote Support server. This is applicable for Central Connect only.
@odata.type: "#HpeSecurityService.v2_2_0.HpeSecurityService"
The HpeSecurityService resource describes the properties for management of the security configuration of the BMC.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/securityservice |
GET PATCH |
Link Name | Destination type |
---|---|
Links/SSO |
HpeiLOSSO |
Links/SecurityParams |
Collection of HpeiLOSecurityParam |
Links/HttpsCert |
HpeHttpsCert |
Links/CertAuth |
HpeCertAuth |
Links/ESKM |
HpeESKM |
Links/SecurityDashboard |
HpeiLOSecurityDashboard |
Member of HpeSecurityService.v2_2_0.HpeSecurityService
Description | Current cipher in use. |
Type | string |
Read Only | True |
Added | iLO 5 1.15 |
LoginSecurityBanner.IsEnabled Member of HpeSecurityService.v2_2_0.HpeSecurityService
Description | Login security banner is enabled or not. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.15 |
LoginSecurityBanner.SecurityMessage Member of HpeSecurityService.v2_2_0.HpeSecurityService
Description | Text message to appear on the iLO login page when login security banner is enabled. |
Type | string |
Read Only | False |
Added | iLO 5 1.15 |
Member of HpeSecurityService.v2_2_0.HpeSecurityService
Description | SSH Host Key identifying the service. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
Member of HpeSecurityService.v2_2_0.HpeSecurityService
Description | The operational security level of this Manager. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Wipe |
Manager is currently wiping security related content and returning to a lower security mode. This state will transition automatically when finished. |
Production |
Manager is operating in a normal security mode. Default state for new systems. |
HighSecurity |
Manager is operating in high security mode, requiring extra authentication on host interface(s), and stronger encryption on network interfaces. |
FIPS |
Similar to High Security. This mode is intended to meet the FIPS 140-2 level 1 and Common Criteria security requirements. A reset to defaults is required to exit this mode. |
CNSA |
Same as FIPS. Additionally meets the criteria for NSA Commercial National Security Algorithm suite. Must be in FIPS mode to transition to CNSA. |
SuiteB |
Same as FIPS. Additionally meets the criteria for NSA SuiteB Top Secret installations. Must be in FIPS mode to transition to SuiteB. |
SynergySecurityMode |
Synergy Security Mode is the mode supported by the Synergy Composer. |
Member of HpeSecurityService.v2_2_0.HpeSecurityService
SecurityState@Redfish.AllowableValues
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value |
---|
Wipe |
Production |
HighSecurity |
FIPS |
CNSA |
SuiteB |
@odata.type: "#HpeServerAccHddService.v1_0_0.HpeServerAccHddService"
The HpeServerAccHddService resource describes the properties for management of shared power in an enclosure.
This resource type was added in iLO 5 1.20 and is available on HPE ProLiant Apollo XL systems.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/acchddservice |
GET |
BackplaneInfo.EndBay Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | Represents a ending number of the bay. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
BackplaneInfo.FirmwareRevision Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | Indicates the firmware revision in ASCII value. |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
BackplaneInfo.HostPortsInfo (array)
Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
HostPortsInfo
is an array containing elements of:
HostPortsInfo[{item}].NodeNumber Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | Represents the node number of compute node attached to host port x in SEP. |
Type | integer |
Read Only | True |
HostPortsInfo[{item}].PortNumber Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | Represents the number of physical host ports in SEP. |
Type | integer |
Read Only | True |
HostPortsInfo[{item}].SlotNumber Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | Represents the slot number of SAS attached to host port x in SEP. |
Type | integer |
Read Only | True |
BackplaneInfo.SEPID Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | Indicates the storage enclosure processor ID. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
BackplaneInfo.SEPNodeId Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | The node ID represent the node ID where the storage enclosure processor is residing. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
BackplaneInfo.StartBay Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | Represents a starting number of the bay. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
BackplaneInfo.TotalBays Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | Total bay count represents the number of bays attached to the SEP. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
BackplaneInfo.TypeID Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | Indicates the Backplane type ID for the identifier for backplane type. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
BackplaneInfo.WWID Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | Represents a unique world wide ID defining a SEP. |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
@odata.type: "#HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone"
The HpeServerAccHddZone resource describes the properties for management of shared hard drives in an enclosure.
This resource type was added in iLO 5 1.20 and is available on HPE ProLiant Apollo XL systems.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/acchddservice/zone |
GET POST |
BackupZoneConfigurationInBmc.HostPort (array)
Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
HostPort
is an array containing elements of:
HostPort[{item}].BayNumber (array)
Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
BayNumber
is an array containing elements of:
Type | integer |
Read Only | True |
HostPort[{item}].PortNumber Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
Description | Represents the number of physical host ports in SEP, null represents unassigned bay group. |
Type | integer or null |
Read Only | True |
CurrentZoneConfiguration.HostPort (array)
Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
HostPort
is an array containing elements of:
HostPort[{item}].BayNumber (array)
Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
BayNumber
is an array containing elements of:
Type | integer |
Read Only | True |
HostPort[{item}].PortNumber Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
Description | Represents the number of physical host ports in SEP, null represents unassigned bay group. |
Type | integer or null |
Read Only | True |
PendingZoneConfiguration.HostPort (array)
Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
HostPort
is an array containing elements of:
HostPort[{item}].BayNumber (array)
Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
BayNumber
is an array containing elements of:
Type | integer |
Read Only | True |
HostPort[{item}].PortNumber Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
Description | Represents the number of physical host ports in SEP, null represents unassigned bay group. |
Type | integer or null |
Read Only | True |
Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
Description | The node ID represent the node ID where the storage enclosure processor is residing. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
Description | Indicates the Backplane type ID for the identifier for backplane type. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
HpeServerAccHddZone.BackupConfigurationToBmc Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone Backup Apollo Chassis Controller Hdd zone configuration to BMC.
There are no parameters for this action.
HpeServerAccHddZone.LoadDefault Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone Load Apollo Chassis Controller default Hdd zone configuration.
There are no parameters for this action.
HpeServerAccHddZone.ConfigureZone Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone Execute Apollo Chassis Controller Hdd zone configuration.
Parameters:
HostPort (array)
@odata.type: "#HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration"
The HpeServerAccPowerCalibration resource describes the properties for management of shared power in an enclosure.
This resource type was added in iLO 5 1.20 and is available on HPE ProLiant Apollo XL systems.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/power/accpowerservice/calibration |
GET POST |
CalibrationData.EndTime Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The calibration end time stamp. |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.StartTime Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The calibration start time stamp. |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.State Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | Specifies whether the calibration is valid or not. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ThrottlePeakPower CalibrationData.ThrottlePeakPower.Percent_000 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 0 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ThrottlePeakPower.Percent_005 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 5 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ThrottlePeakPower.Percent_010 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 10 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ThrottlePeakPower.Percent_015 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 15 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ThrottlePeakPower.Percent_020 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 20 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ThrottlePeakPower.Percent_025 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 25 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ThrottlePeakPower.Percent_030 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 30 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ThrottlePeakPower.Percent_035 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 35 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ThrottlePeakPower.Percent_040 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 40 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ThrottlePeakPower.Percent_045 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 45 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ThrottlePeakPower.Percent_050 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 50 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ThrottlePeakPower.Percent_055 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 55 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ThrottlePeakPower.Percent_060 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 60 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ThrottlePeakPower.Percent_065 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 65 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ThrottlePeakPower.Percent_070 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 70 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ThrottlePeakPower.Percent_075 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 75 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ThrottlePeakPower.Percent_080 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 80 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ThrottlePeakPower.Percent_085 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 85 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ThrottlePeakPower.Percent_090 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 90 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ThrottlePeakPower.Percent_095 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 95 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ThrottlePeakPower.Percent_100 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 100 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
CalibrationData.ZoneNumber Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The zone number either on the entire chassis or specific zone. 0 for entire chassis, other number is for specific zone. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The current state of the chassis power zone calibration task. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
HpeServerAccPowerCalibration.Calibrate Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration Execute the Apollo Chassis Controller power calibration configuration.
Parameters:
EEPROMSaveEnabled (boolean)
AllZone (boolean)
Seconds (integer)
ZoneNumber (integer)
ActionType (string)
Value | Description |
---|---|
Start | |
Stop |
@odata.type: "#HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit"
The HpeServerAccPowerLimit resource describes the properties for management of shared power in an enclosure.
This resource type was added in iLO 5 1.20 and is available on HPE ProLiant Apollo XL systems.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/power/accpowerservice/powerlimit |
GET POST |
Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit
ActualPowerLimits
is an array containing elements of:
ActualPowerLimits[{item}].PowerLimitInWatts Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit
Description | The actual power limit (in watts) for the zone, it will be set to null when power limit disabled. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.20 |
ActualPowerLimits[{item}].ZoneNumber Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit
Description | The zone number either on the entire chassis or specific zone. 0 for entire chassis, other number is for specific zone. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit
PowerLimitRanges
is an array containing elements of:
PowerLimitRanges[{item}].MaximumPowerLimit Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit
Description | The Maximum power limit (in watts) for the zone. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
PowerLimitRanges[{item}].MinimumPowerLimit Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit
Description | The Minimum power limit (in watts) for the zone. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
PowerLimitRanges[{item}].ZoneNumber Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit
Description | The zone number either on the entire chassis or specific zone. 0 for entire chassis, other number is for specific zone. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit
PowerLimits
is an array containing elements of:
PowerLimits[{item}].PowerLimitInWatts Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit
Description | The target power limit (in watts) for the zone, it will be set to null when power limit disabled. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.20 |
PowerLimits[{item}].ZoneNumber Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit
Description | The zone number either on the entire chassis or specific zone. 0 for entire chassis, other number is for specific zone. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
HpeServerAccPowerLimit.ConfigurePowerLimit Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit Deploy the Apollo Chassis Controller power limit configuration.
Parameters:
PowerLimits (array)
@odata.type: "#HpeServerAccPowerNodesInfo.v1_0_0.HpeServerAccPowerNodesInfo"
The HpeServerAccPowerNodesInfo resource describes the properties for management of shared power in an enclosure.
This resource type was added in iLO 5 1.20 and is available on HPE ProLiant Apollo XL systems.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/power/accpowerservice/nodesinfo |
GET |
Member of HpeServerAccPowerNodesInfo.v1_0_0.HpeServerAccPowerNodesInfo
Description | Total Nodes supported in Chassis. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
Member of HpeServerAccPowerNodesInfo.v1_0_0.HpeServerAccPowerNodesInfo
NodeInfoList
is an array containing elements of:
NodeInfoList[{item}].NodeNumber Member of HpeServerAccPowerNodesInfo.v1_0_0.HpeServerAccPowerNodesInfo
Description | The physical node number in chassis. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
NodeInfoList[{item}].Throttle Member of HpeServerAccPowerNodesInfo.v1_0_0.HpeServerAccPowerNodesInfo
Description | It indicates the current throttle on the node. (PWM %) |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
NodeInfoList[{item}].WarningStatus Member of HpeServerAccPowerNodesInfo.v1_0_0.HpeServerAccPowerNodesInfo
Description | Specifies whether the node is in warning status or not. WarningStatus indicates a node is over loading and chassis manager force it throttle at 50% for 5 mins |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
@odata.type: "#HpeServerAccPowerService.v1_0_0.HpeServerAccPowerService"
The HpeServerAccPowerService resource describes the properties for management of shared power in an enclosure.
This resource type was added in iLO 5 1.20 and is available on HPE ProLiant Apollo XL systems.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/power/accpowerservice |
GET PATCH |
Member of HpeServerAccPowerService.v1_0_0.HpeServerAccPowerService
Description | Determines whether the EEPROM save is enabled or disabled. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.20 |
Member of HpeServerAccPowerService.v1_0_0.HpeServerAccPowerService
Description | Determines whether power regulation is enabled or disabled. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.20 |
Member of HpeServerAccPowerService.v1_0_0.HpeServerAccPowerService
Type | string |
Read Only | False |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
ACRedundancy |
AC Redundancy with Throttling Mode (Max Performance w/ Redundancy). |
UserConfig |
User Configurable Mode. |
APM |
APM Power Regulator Mode. Cannot configure by iLO. |
PowerFeedProtect |
Power Feed Protection Mode. |
@odata.type: "#HpeServerAccPowerZone.v1_0_0.HpeServerAccPowerZone"
The HpeServerAccPowerZone resource describes the properties for management of shared power in an enclosure.
This resource type was added in iLO 5 1.20 and is available on HPE ProLiant Apollo XL systems.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/power/accpowerservice/zone |
GET POST |
ZoneConfiguration.Zone (array)
Member of HpeServerAccPowerZone.v1_0_0.HpeServerAccPowerZone
Zone
is an array containing elements of:
Zone[{item}].Node (array)
Member of HpeServerAccPowerZone.v1_0_0.HpeServerAccPowerZone
Node
is an array containing elements of:
Node[{item}].NodeNumber Member of HpeServerAccPowerZone.v1_0_0.HpeServerAccPowerZone
Description | The node number of zone configuration. |
Type | integer |
Read Only | True |
Node[{item}].NodePriority Member of HpeServerAccPowerZone.v1_0_0.HpeServerAccPowerZone
Description | The power regulation node priority, the range must between 1 - 5. 5 is default and lowest priority. |
Type | integer |
Read Only | True |
Zone[{item}].ZoneNumber Member of HpeServerAccPowerZone.v1_0_0.HpeServerAccPowerZone
Description | The zone number of zone configuration. |
Type | integer |
Read Only | True |
Zone[{item}].ZonePriority Member of HpeServerAccPowerZone.v1_0_0.HpeServerAccPowerZone
Description | The power regulation zone priority, the range must between 1 - 5. 5 is default and lowest priority. |
Type | integer |
Read Only | True |
HpeServerAccPowerZone.ConfigureZone Member of HpeServerAccPowerZone.v1_0_0.HpeServerAccPowerZone Execute the Apollo Chassis Controller power regulation zone configuration.
Parameters:
Zone (array)
@odata.type: "#HpeServerBootSettings.v2_0_0.HpeServerBootSettings"
The schema definition of the server UEFI Boot Order resource.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/bios/boot |
GET |
/redfish/v1/systems/{item}/bios/boot/settings |
GET PATCH |
Link Name | Destination type |
---|---|
@Redfish.Settings/SettingsObject |
HpeServerBootSettings |
Oem/Hpe/Links/BaseConfigs |
HpeBaseConfigs |
Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings See the Redfish standard schema and specification for information on common @Redfish properties.
Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
BootSources
is an array containing elements of:
BootSources[{item}].BootString Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
Description | User-readable string that describes the UEFI boot option. |
Type | string |
Read Only | True |
BootSources[{item}].CorrelatableID Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
Description | Contains any CorrelatableIDs that represent this boot option. The correlatableID values can be JSON Pointers or UEFI identifiers. |
Type | string |
Read Only | True |
BootSources[{item}].StructuredBootString Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
Description | Uniquely identifies this boot option within the server. |
Type | string |
Read Only | True |
BootSources[{item}].UEFIDevicePath Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
Description | Standardized text representation of the UEFI device path for this boot option, in UTF-8 format. |
Type | string |
Read Only | True |
Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
DefaultBootOrder
is an array containing elements of:
Description | Default UEFI boot order device type. This is used to define the order in which UEFI boot order is reset to when a default configuration is requested. |
Type | string |
Read Only | True |
The following are the supported values:
Value |
---|
UefiShell |
Floppy |
Cd |
Usb |
EmbeddedStorage |
PcieSlotStorage |
EmbeddedFlexLOM |
PcieSlotNic |
Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
DesiredBootDevices
is an array containing elements of:
DesiredBootDevices[{item}].CorrelatableID Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
Description | Standardized text representation of the UEFI device path of the desired boot device, in UTF-8 format. For example 'PciRoot(0x0)/Pci(0x2,0x2)/Pci(0x0,0x0)' |
Type | string |
Read Only | False |
DesiredBootDevices[{item}].Lun Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
Description | The Logical Unit Number (LUN) of the desired boot device. This value must be a hexadecimal string with an even number of 2 to 16 characters, excluding the first two characters, 0x (for example, '0x01'). |
Type | string |
Read Only | False |
DesiredBootDevices[{item}].Wwn Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
Description | The Fibre Channel World Wide Name (WWN) of the desired boot device. This value must be a hexadecimal string with an even number of 2 to 16 characters, excluding the first two characters, 0x (for example, '0x0001020304050607'). |
Type | string |
Read Only | False |
DesiredBootDevices[{item}].iScsiTargetName Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
Description | The iSCSI node target name of the desired boot device. The value must be a string based on IETF RFC 3270, and can be up to 223 characters in length (for example, 'iqn.1991-05.com.microsoft:iscsitarget-iscsidisk-target'). |
Type | string |
Read Only | False |
Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
PersistentBootConfigOrder
is an array containing elements of:
Description | The structured boot string that references a corresponding entry in the BootSources array. |
Type | string |
Read Only | True |
@odata.type: "#HpeServerDevice.v2_0_0.HpeServerDevice"
The HpeServerDevice resource describes the properties of FRU devices.
This resource type was added in iLO 5 1.20
HpeServerDevice represents physical server devices including part information. This is especially useful for system inventory.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/devices/{item} |
GET PATCH |
Link Name | Destination type |
---|---|
DeviceInstances[] |
HpeServerPciDevice |
Member of HpeServerDevice.v2_0_0.HpeServerDevice
DeviceInstances
is an array containing elements of:
DeviceInstances[{item}].@odata.id Member of HpeServerDevice.v2_0_0.HpeServerDevice
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeServerDevice.v2_0_0.HpeServerDevice
Description | Device type. |
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
GPU |
GPU |
PLX Controller |
PLX Controller (Bridge) |
Expansion Riser |
Expansion Riser |
Smart Storage |
Smart Storage |
SAS/SATA Storage Controller |
SAS/SATA Storage Controller |
IDE Storage controller |
|
USB Storage Controller |
USB Storage Controller |
Storage Controller |
Storage Controller |
LOM/NIC |
LOM/NIC |
Converged Network Adapter |
Converged Network Adapter |
Fibre Channel |
Fibre Channel |
Direct Attached NVMe Device |
Direct Attached NVMe Device |
Backplane PIC |
Backplane PIC |
Smart Storage Battery |
Smart Storage Battery |
USB |
Universal Serial Bus |
TPM |
Trusted Platform Module |
Communication Controller |
Communication Controller |
Unknown |
Unknown Device Type |
FirmwareVersion.Current FirmwareVersion.Current.VersionString Member of HpeServerDevice.v2_0_0.HpeServerDevice
Description | This string represents the version of the firmware image. |
Type | string or null |
Read Only | True |
Member of HpeServerDevice.v2_0_0.HpeServerDevice
Description | Location of the device. |
Type | string or null |
Read Only | True |
Member of HpeServerDevice.v2_0_0.HpeServerDevice
Description | Set to true to disable MCTP on this slot. Once disabled, can be enabled only through MCTP factory reset. |
Type | boolean |
Read Only | False |
Member of HpeServerDevice.v2_0_0.HpeServerDevice
Description | Device manufacturer. |
Type | string or null |
Read Only | True |
Member of HpeServerDevice.v2_0_0.HpeServerDevice
Description | Board part Number which is HPE PCA Assembly Number. |
Type | string or null |
Read Only | True |
Member of HpeServerDevice.v2_0_0.HpeServerDevice
Description | Product Part Number. |
Type | string or null |
Read Only | True |
Member of HpeServerDevice.v2_0_0.HpeServerDevice
Description | Product Version. |
Type | string or null |
Read Only | True |
Member of HpeServerDevice.v2_0_0.HpeServerDevice
Description | Product Serial Number. |
Type | string or null |
Read Only | True |
Member of HpeServerDevice.v2_0_0.HpeServerDevice See the Redfish standard schema and specification for information on common Status object.
@odata.type: "#HpeServerDeviceCollection.HpeServerDeviceCollection"
A Collection of HpeServerDevice resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/devices |
GET |
Link Name | Destination type |
---|---|
Members[] |
HpeServerDevice |
Member of HpeServerDeviceCollection.HpeServerDeviceCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeServerDeviceCollection.HpeServerDeviceCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeServerDeviceCollection.HpeServerDeviceCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeServerPciDevice.v2_0_0.HpeServerPciDevice"
The HpeServerPciDevice resource describes the properties of PCI devices.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/pcidevices/{item} |
GET |
Member of HpeServerPciDevice.v2_0_0.HpeServerPciDevice
Description | Bay number value. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeServerPciDevice.v2_0_0.HpeServerPciDevice
Description | PCI device bus number value. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeServerPciDevice.v2_0_0.HpeServerPciDevice
Description | PCI class code of the endpoint. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeServerPciDevice.v2_0_0.HpeServerPciDevice
Description | PCI device ID of the device. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeServerPciDevice.v2_0_0.HpeServerPciDevice
Description | PCI device instance value. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeServerPciDevice.v2_0_0.HpeServerPciDevice
Description | PCI device location. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeServerPciDevice.v2_0_0.HpeServerPciDevice
Description | PCI device number value. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeServerPciDevice.v2_0_0.HpeServerPciDevice
Description | PCI device sub-instance value. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeServerPciDevice.v2_0_0.HpeServerPciDevice
Description | Device type value. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Flexible LOM |
Flexible LAN-On-Motherboard |
Embedded LOM |
Embedded LAN-On-Motherboard |
NIC |
Network Interface Controller |
HDD Not attached to a SA Controller |
Hard Disk Drive |
HDD Attached to a SA Controller |
Hard Disk Drive attached to an array controller |
Other PCI Device |
Other PCI Device |
Unknown |
Unknown PCI Device |
Other |
Other PCI Device |
Video |
Video Controller |
SCSI Controller |
SCSI Controller |
Ethernet |
Ethernet Controller |
Token Ring |
Token Ring Controller |
Sound |
Sound Controller |
PATA Controller |
Parallel ATA Controller |
SATA Controller |
Serial ATA Controller |
SAS Controller |
Serial Attached SCSI Controller |
Storage Controller |
Storage Controller (not Smart Array) |
Storage Array Controller |
Smart Array Storage Controller |
USB Hard Disk Drive |
USB Hard Disk Drive |
Firmware Volume |
Firmware Volume |
UEFI Shell |
UEFI Shell |
Generic UEFI USB Boot Entry |
Generic UEFI USB Boot Entry |
Dynamic Storage Array Controller |
Dynamic Smart Array Controller |
File |
File |
NVMe Hard Drive |
NVMe Hard Drive |
NVDIMM |
NVDIMM |
Member of HpeServerPciDevice.v2_0_0.HpeServerPciDevice
Description | Enclosure number value. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeServerPciDevice.v2_0_0.HpeServerPciDevice
Description | PCI device function number value. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeServerPciDevice.v2_0_0.HpeServerPciDevice
Description | Text representation of the UEFI device location, in UTF-8 format |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeServerPciDevice.v2_0_0.HpeServerPciDevice
Description | PCI segment group number value. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeServerPciDevice.v2_0_0.HpeServerPciDevice
Description | PCI device structured name in UTF-8 format. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeServerPciDevice.v2_0_0.HpeServerPciDevice
Description | PCI sub class code of the endpoint. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeServerPciDevice.v2_0_0.HpeServerPciDevice
Description | PCI subsystem device ID of the device. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeServerPciDevice.v2_0_0.HpeServerPciDevice
Description | PCI subsystem vendor ID of the device. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeServerPciDevice.v2_0_0.HpeServerPciDevice
Description | Standardized text representation of the UEFI device path, in UTF-8 format. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeServerPciDevice.v2_0_0.HpeServerPciDevice
Description | PCI vendor ID of the device. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
@odata.type: "#HpeServerPciDeviceCollection.HpeServerPciDeviceCollection"
A Collection of HpeServerPciDevice resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/pcidevices |
GET |
Link Name | Destination type |
---|---|
Members[] |
HpeServerPciDevice |
Member of HpeServerPciDeviceCollection.HpeServerPciDeviceCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeServerPciDeviceCollection.HpeServerPciDeviceCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeServerPciDeviceCollection.HpeServerPciDeviceCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeServerPCISlot.v2_1_0.HpeServerPCISlot"
The HpeServerPCISlot resource describes the properties of PCI slots.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/pcislots/{item} |
GET |
Member of HpeServerPCISlot.v2_1_0.HpeServerPCISlot
Description | PCI slot bus number. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
Characteristics.Provides3_3Volts Member of HpeServerPCISlot.v2_1_0.HpeServerPCISlot
Description | Provides 3.3 volts. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
Characteristics.Provides5Volts Member of HpeServerPCISlot.v2_1_0.HpeServerPCISlot
Description | Provides 5.0 volts. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
Characteristics.SlotIsShared Member of HpeServerPCISlot.v2_1_0.HpeServerPCISlot
Description | The slot shares its opening with another slot. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
Characteristics.SupportsCardBus Member of HpeServerPCISlot.v2_1_0.HpeServerPCISlot
Description | PC Card slot supports Card Bus. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
Characteristics.SupportsHotPlugDevices Member of HpeServerPCISlot.v2_1_0.HpeServerPCISlot
Description | Slot supports hot-plug devices. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
Characteristics.SupportsModemRingResume Member of HpeServerPCISlot.v2_1_0.HpeServerPCISlot
Description | PC Card slot supports Modem Ring Resume. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
Characteristics.SupportsPCCard16 Member of HpeServerPCISlot.v2_1_0.HpeServerPCISlot
Description | PC Card slot supports PC Card-16. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
Characteristics.SupportsPowerManagementEventSignal Member of HpeServerPCISlot.v2_1_0.HpeServerPCISlot
Description | PCI slot supports Power Management Event signal. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
Characteristics.SupportsSMBusSignal Member of HpeServerPCISlot.v2_1_0.HpeServerPCISlot
Description | PCI slot supports SMBUS signal. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
Characteristics.SupportsZoomVideo Member of HpeServerPCISlot.v2_1_0.HpeServerPCISlot
Description | PC Card slot supports Zoom Video. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
Member of HpeServerPCISlot.v2_1_0.HpeServerPCISlot
Description | PCI slot device number. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
Member of HpeServerPCISlot.v2_1_0.HpeServerPCISlot
Description | PCI slot function number. |
Type | integer |
Read Only | True |
Added | iLO 5 1.20 |
Member of HpeServerPCISlot.v2_1_0.HpeServerPCISlot
Description | PCI slot length |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Short |
Long |
Other |
Member of HpeServerPCISlot.v2_1_0.HpeServerPCISlot
Description | Bandwidth capacity of the slot, measured by the number of PCI Express Lanes present. Also known as the slot width. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
8 bit |
16 bit |
32 bit |
64 bit |
128 bit |
x1 |
x2 |
x4 |
x8 |
x16 |
x32 |
Other |
Member of HpeServerPCISlot.v2_1_0.HpeServerPCISlot See the Redfish standard schema and specification for information on common Status object.
Member of HpeServerPCISlot.v2_1_0.HpeServerPCISlot
Description | Specifies whether the slot supports hot-plug devices. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeServerPCISlot.v2_1_0.HpeServerPCISlot
Description | PCI technology |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
PCIExpressGen3 |
PCIExpressGen2 |
PCIExpress |
Member of HpeServerPCISlot.v2_1_0.HpeServerPCISlot
Description | Standardized text representation of the UEFI device path, in UTF-8 format |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
@odata.type: "#HpeServerPCISlotCollection.HpeServerPCISlotCollection"
A Collection of HpeServerPCISlot resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/pcislots |
GET |
Link Name | Destination type |
---|---|
Members[] |
HpeServerPCISlot |
Member of HpeServerPCISlotCollection.HpeServerPCISlotCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeServerPCISlotCollection.HpeServerPCISlotCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeServerPCISlotCollection.HpeServerPCISlotCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeSmartStorage.v2_0_0.HpeSmartStorage"
The HpeSmartStorage resource describes the properties of the HPE Smart Storage controller,drives,and volumes.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/smartstorage |
GET |
Link Name | Destination type |
---|---|
Links/HostBusAdapters |
Collection of HpeSmartStorageHostBusAdapter |
Links/ArrayControllers |
Collection of HpeSmartStorageArrayController |
Member of HpeSmartStorage.v2_0_0.HpeSmartStorage See the Redfish standard schema and specification for information on common Status object.
@odata.type: "#HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController"
The HpeSmartStorageArrayController resource describes the properties of the HPE Smart Storage controller,drives,and volumes.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/smartstorage/arraycontrollers/{item} |
Link Name | Destination type |
---|---|
Links/PhysicalDrives |
Collection of HpeSmartStorageDiskDrive |
Links/LogicalDrives |
Collection of HpeSmartStorageLogicalDrive |
Links/StorageEnclosures |
Collection of HpeSmartStorageStorageEnclosure |
Links/UnconfiguredDrives |
Collection of HpeSmartStorageDiskDrive |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | Type of Smart controller |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
SmartArray |
A controller that supports all SmartArray features and configuration |
SmartHBA |
A controller that functions natively as an HBA, but has a ValueRAID mode for basic RAID configuration |
DynamicSmartArray |
A controller that allows software RAID configuration |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The number of arrays configured on this controller |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The current status of the backup power source (battery, capacitor, megacell etc.) |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Present |
The backup power source is present but charging information is unknown |
NotPresent |
The backup power source is not present |
PresentAndCharged |
The backup power source is present and fully charged |
PresentAndCharging |
The backup power source is present and is currently charging |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The primary boot volume of this controller |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The secondary boot volume of this controller |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The number of cache arrays configured on this controller |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The number of cache logical drives configured on this controller |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The total cache memory size for the controller in MiB |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The serial number of the Cache Module. |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
CacheModuleStatus.Health Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | This represents the health state of this resource in the absence of its dependent resources. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OK |
Normal |
Warning |
A condition exists that requires attention |
Critical |
A critical condition exists that requires immediate attention |
CacheModuleStatus.HealthRollup Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | This represents the overall health state from the view of this resource. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OK |
Normal |
Warning |
A condition exists that requires attention |
Critical |
A critical condition exists that requires immediate attention |
CacheModuleStatus.State Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | This indicates the known state of the resource, such as if it is enabled. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Enabled |
This function or resource has been enabled. |
Disabled |
This function or resource has been disabled. |
StandbyOffline |
This function or resource is enabled, but awaiting an external action to activate it. |
StandbySpare |
This function or resource is part of a redundancy set and is awaiting a failover or other external action to activate it. |
InTest |
This function or resource is undergoing testing. |
Starting |
This function or resource is starting. |
Absent |
This function or resource is not present or not detected. |
UnavailableOffline |
This function or resource is present but cannot be used. |
Deferring |
The element will not process any commands but will queue new requests. |
Quiesced |
The element is enabled but only processes a restricted set of commands. |
Updating |
The element is updating and may be unavailable or degraded. |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The number of physical drives assigned as cache drives attached to this controller |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
ControllerBoard.Status Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController See the Redfish standard schema and specification for information on common Status object.
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | Smart Array Controller Part Number |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The current operating mode of the controller. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
RAID |
The controller is currently functioning in RAID mode |
HBA |
The controller is currently functioning in HBA mode |
Mixed |
The controller is currently functioning in Mixed mode |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | Number of disks the controller is scanning in parallel |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The number of data logical drives configured on this controller |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The number of physical drives assigned as data drives attached to this controller |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | Enables the controller to attempt to improve performance on RAID 5/50/6(ADG)/60 logical drives when one or more physical drives in the logical drive are failed |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
The controller will attempt to improve performance by buffering physical drive requests |
Disabled |
The controller will not buffer, which may result in reading from the same drive multiple times |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | Enables or disables the write cache of the physical drives attached to the controller |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
The write cache of the physical drives attached to the controller are enabled |
Disabled |
The write cache of the physical drives attached to the controller are enabled |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | Enables the controller to sort requests to a physical drive |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
The controller will sort the requests to minimize the amount of seeking the drive must perform in order to reduce seek times |
Disabled |
The controller will perform the requests as they are recieved in order to improve request throughput |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if there is a boot password set, false otherwise |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if a password has been set for the Encryption Crypto Officer, false otherwise |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if the encryption CSP test passed, false otherwise. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if encryption is currently enabled for this controller, false otherwise |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if the controller firmware has been locked, preventing firmware updates, false otherwise |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if the controller has one or more volumes that are locked, false otherwise |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if there are locked drives due to a missing boot password, false otherwise |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if the controller password has been temporarily suspended, false otherwise |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if the Master Key has been set, false otherwise |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if the controller caches encryption keys locally when a remote key manager is being used, false otherwise |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if the controller will allow plaintext and encrypted volumes to exist simultaneously, false otherwise |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The number of encrypted physical drives attached to the controller |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if the encryption password recovery question and answer have been set, false otherwise |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if the encryption self test passed, false otherwise. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if the controller manages encryption keys locally, false if a remote key manager is being used |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if a password has been set for the Encryption User, false otherwise. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The level of priority that transformations have over handling current operating system requests |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
High |
Transformations will complete as fast as possible at the expense of normal I/O |
Medium |
Transformations will perform with some impact on normal I/O |
Low |
Transformations will perform only when normal I/O is not occurring and may take longer to complete |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The number of external ports |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
FirmwareVersion.Current FirmwareVersion.Current.VersionString Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | This string represents the version of the firmware image. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | This allows the controller to process certain high-latency requests after a delay that may time out when elevator sorting |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Default |
The controller will rely only on elevator sorting |
Low250 |
The controller will apply a cutoff value of 250ms when suspending elevator sorting |
Middle100 |
The controller will apply a cutoff value of 100ms when suspending elevator sorting |
Middle50 |
The controller will apply a cutoff value of 50ms when suspending elevator sorting |
Aggressive30 |
The controller will apply a cutoff value of 30ms when suspending elevator sorting |
Aggressive10 |
The controller will apply a cutoff value of 10ms when suspending elevator sorting |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The hardware revision of the controller |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | Enables the controller to update data on RAID 6(ADG) and 60 volumes based on parity information when an inconsistency is discovered during surface scan |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
The controller will update the data on the drives based on the parity information |
Disabled |
The controller will only update the parity information and leave the data untouched |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The number of internal ports |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if this controller is the OS boot controller, false otherwise |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | Location identifier |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | Format for Location Identifier |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
PCISlot |
The PCI slot the controller is located at. For embedded controllers, the slot is 0 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The number of logical drives configured on this controller |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The manufacturer of the controller |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | Maximum number of disks that the controller supports scanning in parallel |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The model number for the controller |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The operating mode the controller will be functioning in (RAID versus HBA) after a reboot |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
RAID |
The controller will be functioning in RAID mode after rebooting |
HBA |
The controller will be functioning in HBA mode after rebooting |
Mixed |
The controller will be functioning in Mixed mode after rebooting |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if the controller supports scanning multiple disk surfaces |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The number of physical drives attached to this controller |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The power mode of the controller after a reboot |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Invalid |
The controller will be operating in an unknown power mode after a reboot |
Low |
The controller will be operating in minimum power mode after a reboot |
LowAutomated |
The controller will be operating in a balanced mode after a reboot |
Performant |
The controller will be operating in maximum performance power mode after a reboot |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The current power mode of the controller |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Invalid |
The power mode can not be determined |
Low |
The controller is currently operating in minimum power mode |
LowAutomated |
The controller is currently operating in a balanced power mode |
Performant |
The controller is currently operating in maximum performance power mode |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if the controller's drive configuration has changed while using configuration based power settings, false otherwise |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if the controller has a new power mode configured, false otherwise |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if a reboot is required to change the active power mode on the controller, false otherwise |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
NotRequired |
No reboot is required |
RequiredNoReason |
A reboot is required for the configured power mode on the controller |
RequiredPowerSavings |
Rebooting will enable additional power savings on the controller |
RequiredPerformance |
Rebooting will enhance the performance of the controller |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if the controller has crossed a critical temperature threshold and performance has been reduced to prevent damage to the controller, false otherwise |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | Enables or disables predictive spare rebuild mode |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
Spare drives will replace physical drives that are predicted to fail preemptively |
Disabled |
Spare drives will replace physical drives only when they fail |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | This sets the maximum number of requests the controller will submit to a drive at any given time |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
2 |
2 requests |
4 |
4 requests |
8 |
8 requests |
16 |
16 requests |
32 |
32 requests |
Automatic |
Automatically determine the best queue depth for the controller |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | This indicates the percentage of cache used for read cache on the controller, with the rest of the cache being used for write cache |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.20 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The level of priority that rebuilds have over handling current operating system requests |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
High |
Rebuilds will complete as fast as possible at the expense of normal I/O |
Medium |
Rebuilds will perform with some impact on normal I/O |
Low |
Rebuilds will perform only when normal I/O is not occurring and may take longer to complete |
RapidHigh |
Rebuilds will complete as fast as possible at the expense of normal I/O |
RapidMediumHigh |
Rebuilds will perform with an impact on normal I/O |
RapidMedium |
Rebuilds will perform with some impact on normal I/O |
RapidLow |
Rebuilds will perform only when normal I/O is not occurring and may take longer to complete |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The serial number for this controller |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The firmware version of the underlying HBA that is being used by the software RAID stack |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The option ROM firmware version used to bootstrap the software RAID stack |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | he number of physical drives assigned as spare drives attached to this controller |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController See the Redfish standard schema and specification for information on common Status object.
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
SupportedOperatingModes
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
RAID |
The controller supports functioning in RAID mode |
HBA |
The controller supports functioning in HBA mode |
Mixed |
The controller supports functioning in Mixed mode |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
SupportedPowerModes
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Low |
The controller is currently operating in minimum power mode |
LowAutomated |
The controller is currently operating in a balanced power mode |
Performant |
The controller is currently operating in maximum performance power mode |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
SupportedRaidLevels
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
0 |
There is no fault tolerance used on the logical drive |
1 |
Two sets of duplicate data is being stored on a pair of drives |
1ADM |
Three sets of duplicate data is being stored on a trio of drives |
10 |
Data is duplicated and striped across pairs of disk drives |
10ADM |
Data is duplicated and striped across trios of disk drives |
5 |
Fault tolerance is achieved by storing parity data across 3 or more disk drives |
50 |
Fault tolerance is achieved by storing parity data and striping the data across 6 or more disk drives |
6 |
Fault tolerance is achieved by storing multiple sets parity data across 4 or more disk drives |
60 |
Fault tolerance is achieved by storing multiple sets parity data and striping the data across 8 or more disk drives |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | Priority that the controller takes to find and correct disk surface errors |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Disabled |
Surface scan is disabled and may lead to data loss |
High |
Surface scan commands will be sent with the host I/O, resulting in faster scanning, but may inpact host I/O performance |
Medium |
Surface scan commands have a medium priority, and will have some impact on host I/O performance |
Low |
Surface scan commands have a low priority, and will have little impact on host I/O performance |
Idle |
Surface scan commands will ony be issued when no host I/O is present after a delay |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | The number of unassigned physical drives attached to this controller |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | This value sets the write cache bypass threshold, ranging from 16 KB to 1040 KB in multiples of 16 KB, where all writes larger than the specified value in KB units will bypass the write cache and be written directly to the disk for non-parity RAID volumes. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Member of HpeSmartStorageArrayController.v2_2_0.HpeSmartStorageArrayController
Description | True if the controller will continue to use write cache even if the backup power source is not available. False, otherwise. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
@odata.type: "#HpeSmartStorageArrayControllerCollection.HpeSmartStorageArrayControllerCollection"
A Collection of HpeSmartStorageArrayController resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/smartstorage/arraycontrollers |
Link Name | Destination type |
---|---|
Members[] |
HpeSmartStorageArrayController |
Member of HpeSmartStorageArrayControllerCollection.HpeSmartStorageArrayControllerCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeSmartStorageArrayControllerCollection.HpeSmartStorageArrayControllerCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeSmartStorageArrayControllerCollection.HpeSmartStorageArrayControllerCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive"
The HpeSmartStorageDiskDrive resource describes the properties of the HPE Smart Storage controller,drives,and volumes.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/smartstorage/arraycontrollers/{item}/diskdrives/{item} |
|
/redfish/v1/systems/{item}/smartstorage/arraycontrollers/{item}/unconfigureddrives/{item} |
|
/redfish/v1/systems/{item}/smartstorage/hostbusadapters/{item}/diskdrives/{item} |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | Block size of the drive in bytes. This is the block size presented by the drive to clients such as the array controller or operating system. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | Total capacity of the drive in GB. This denotes the marketing capacity (base 10) |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | Total number of logical blocks in the drive |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | Total capacity of the drive in MiB |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | Carrier PIC firmware version currently running |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | Authentication status of the drive carrier |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
OK |
Carrier authenticated as genuine HPE product |
Fail |
Carrier authentication failed |
NoCommunication |
Communication could not be established with the carrier |
NotApplicable |
Carrier does not support authentication |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | The current temperature of the drive |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
DiskDriveStatusReasons
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
None |
No status reason available |
Unknown |
Reason is unknown |
CommunicationFailure |
Cannot communicate with drive |
Zoned |
Drive is currently zoned, only basic information can be displayed |
EraseInProgress |
Drive is currently in process of an erase operation |
QueuedForErase |
Drive is currently queued for an erase operation |
EraseCompleted |
Drive has completed the erase operation |
EraseFailed |
The erase operation has failed for the drive |
EraseAborted |
The erase operation was aborted |
Failed |
The drive has failed |
NonAuthenticDrive |
The drive is not an authentic drive |
CarrierCommunicationFailure |
The drive carrier has a communication fault |
PredictiveFail |
Drive failure is imminent |
NotSupported |
The drive is not supported by the controller |
SizeNotValid |
The drive size is invalid. Typically occurs if a drive part of a raid volume is replaced with a smaller sized drive |
FailedDueToPredictiveSpareActivation |
The drive was failed due to a predictive spare activation |
Rebuilding |
The drive is currently rebuilding |
TransientDataDrive |
The drive is part of a volume that is currently undergoing a transformation. After the transformation is complete the drive's state will change |
Unrecoverable |
The drive is in an unrecoverable condition |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | The current use of the physical drive. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Data |
It is a Data drive which is a part of an array. |
Spare |
It is a spare drive which is a part of an array. |
Raw |
Indicates the drive is available to the OS via HBA mode on the controller. |
Unconfigured |
Indicates the drive is not available to the OS as controller is in RAID mode. |
Unknown |
The current use of the disk drive is not known. |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | True if encryption is currently enabled on this disk drive, false otherwise |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | The percent complete for an erase operation currently occurring on the disk drive or null if not currently erasing a drive. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | The pattern used for erasing the disk drive |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
FirmwareVersion.Current FirmwareVersion.Current.VersionString Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | This string represents the version of the firmware image. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | The state of the indicator LED. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Unknown |
The state of the Indicator LED cannot be determined. |
Lit |
The Indicator LED is lit. |
Blinking |
The Indicator LED is blinking. |
Off |
The Indicator LED is off. |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | Native interface speed for the device |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | The connection interface of the drive. The value NVME has been deprecated. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
SAS |
SAS |
SATA |
SATA |
NVME |
Non-volatile memory (deprecated) |
PCIe |
PCIe interface |
Unknown |
Information is unavailable |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | This indicates that the array controller should provide legacy boot support. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Primary |
This indicates that the array controller should provide legacy boot support (Interrupt 13h BIOS support) for this physical drive. The physical drive will be listed as first in the LUN list returned via SCSI commands |
Secondary |
This indicates that the array controller should provide legacy boot support (Interrupt 13h BIOS support) for this physical drive. The physical drive will be listed as second in the LUN list returned via SCSI commands |
None |
Legacy boot not supported on this physical drive |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | The location of the drive |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | Format for the location property |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
ControllerPort:Box:Bay |
This format typically used in controller context where the drive would be identified using the controller port, JBOD box number and drive bay |
SwitchPort:Box:Bay |
This format typically used in a SAS switch context where the drive would be identified using the switch port, JBOD box number and drive bay |
SwitchPort:SwitchBay:Bay |
This format typically used in a SAS switch context where the drive would be identified using the switch port, ICM bay number for the switch and drive bay |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | Manufacturer of the disk drive |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | The maximum recommended temperature for the drive |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | Type of disk |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
HDD |
The drive media type is traditional magnetic platters |
SSD |
The drive media type is solid state or flash memory |
SMR |
The drive media type is shingled magnetic recording |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | The minimum recommended firmware revision for the drive |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | Drive model number |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | Native block size of the drive in bytes. This is the underlying sector size used by the physical drive to store data. For example, an advanced format drive that uses 4K sector sizes to store data will return 4K as the NativeBlockSizeBytes but may return 512 for the BlockSizeBytes when running in 512e (emulation) mode for backward compatibility |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | The number of phys the drive has |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | The number of ports on the drive. Typically 1 (single-domain) or 2 (dual-domain) |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | The number of lifetime hours that the drive has been powered on. The value is null if the disk power on hours cannot be determined or is not supported. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | The rotational speed of the drive, only applicable on HDDs |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | This is the percentage of the drive that has been worn out and can no longer be used. When this values reaches 100%, the drive has 0% usage remaining and is completely worn out. The value is null if percent endurance used cannot be determined or is not supported. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | The serial number of the drive |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | Method to used activate this drive when another drive fails, this is only applicable if the drive is configured as a spare drive |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Dedicated |
This drive will take over a failed drive temporarily. When the failed drive is replaced, this will return to being a spare. This drive be shared between arrays. |
Roaming |
This drive will permanently replace a failed drive. The failed drive will become a spare. This spare drive cannot be shared between arrays. |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive See the Redfish standard schema and specification for information on common Status object.
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | Effective transfer speed to the device taking into account hardware acceleration such as edge-buffering |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | The number of read errors that have occurred on a drive that could not be recovered by a drive's Error Correction Code (ECC) algorithm or through retries. Over time, a drive may produce these errors, and a problem may exist. The value increases every time the physical drive detects another error. The severity of these errors depends on if the drive is in a fault tolerant mode and the controller can remap data to eliminate problems. If an increase in this counter is seen, run diagnostics on the drive |
Type | integer |
Read Only | True |
Added | iLO 5 1.40 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | The number of write errors that have occurred on a drive that could not be recovered through retries. Over time, a drive may produce these errors, and a problem may exist. The value increases every time the physical drive detects another error. If an increase in this counter is seen, run diagnostics on the drive. |
Type | integer |
Read Only | True |
Added | iLO 5 1.40 |
Member of HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive
Description | Unique identifier for the device |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
@odata.type: "#HpeSmartStorageDiskDriveCollection.HpeSmartStorageDiskDriveCollection"
A Collection of HpeSmartStorageDiskDrive resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/smartstorage/arraycontrollers/{item}/unconfigureddrives |
|
/redfish/v1/systems/{item}/smartstorage/hostbusadapters/{item}/diskdrives |
Link Name | Destination type |
---|---|
Members[] |
HpeSmartStorageDiskDrive |
Member of HpeSmartStorageDiskDriveCollection.HpeSmartStorageDiskDriveCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeSmartStorageDiskDriveCollection.HpeSmartStorageDiskDriveCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeSmartStorageDiskDriveCollection.HpeSmartStorageDiskDriveCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeSmartStorageHostBusAdapter.v2_0_0.HpeSmartStorageHostBusAdapter"
The HpeSmartStorageHostBusAdapter resource describes the properties of the HPE Smart Storage controller,drives,and volumes.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/smartstorage/hostbusadapters/{item} |
GET |
Link Name | Destination type |
---|---|
Links/Drives |
Collection of HpeSmartStorageDiskDrive |
FirmwareVersion.Current FirmwareVersion.Current.VersionString Member of HpeSmartStorageHostBusAdapter.v2_0_0.HpeSmartStorageHostBusAdapter
Description | This string represents the version of the firmware image. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageHostBusAdapter.v2_0_0.HpeSmartStorageHostBusAdapter
Description | The hardware revision of the controller |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageHostBusAdapter.v2_0_0.HpeSmartStorageHostBusAdapter
Description | Location identifier |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageHostBusAdapter.v2_0_0.HpeSmartStorageHostBusAdapter
Description | Format for Location Identifier |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
PCISlot |
The PCI slot the controller is located at. For embedded controllers, the slot is 0 |
Member of HpeSmartStorageHostBusAdapter.v2_0_0.HpeSmartStorageHostBusAdapter
Description | The manufacturer of the controller |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageHostBusAdapter.v2_0_0.HpeSmartStorageHostBusAdapter
Description | The model number for the controller |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageHostBusAdapter.v2_0_0.HpeSmartStorageHostBusAdapter
Description | The serial number for this controller |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageHostBusAdapter.v2_0_0.HpeSmartStorageHostBusAdapter See the Redfish standard schema and specification for information on common Status object.
@odata.type: "#HpeSmartStorageHostBusAdapterCollection.HpeSmartStorageHostBusAdapterCollection"
A Collection of HpeSmartStorageHostBusAdapter resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/smartstorage/hostbusadapters |
GET |
Link Name | Destination type |
---|---|
Members[] |
HpeSmartStorageHostBusAdapter |
Member of HpeSmartStorageHostBusAdapterCollection.HpeSmartStorageHostBusAdapterCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeSmartStorageHostBusAdapterCollection.HpeSmartStorageHostBusAdapterCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeSmartStorageHostBusAdapterCollection.HpeSmartStorageHostBusAdapterCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive"
The HpeSmartStorageLogicalDrive resource describes the properties of the HPE Smart Storage controller,drives,and volumes.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/smartstorage/arraycontrollers/{item}/logicaldrives/{item} |
Link Name | Destination type |
---|---|
Links/DataDrives |
Collection of HpeSmartStorageDiskDrive |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | The acceleration method of the logical drive |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
None |
Logical drive acceleration is disabled |
ControllerCache |
Reads and writes to the logical drive are being cached by the controller. |
IOBypass |
For logical drives on SSDs, read and write information directly from the drive. |
SmartCache |
Reads and writes to the logical drive are being cached by a caching logical drive. |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | The block size of the disk drive in bytes |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | Total usable capacity available on this logical drive in MiB units |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | The access ID of the logical drive given by the OS |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | The number of cylinders on the drive |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | The number of heads on the drive |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | The number of sectors on the drive |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | The connection interface of the logical drive. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
SAS |
SAS |
SATA |
SATA |
Mixed |
Contains both SAS and SATA. |
Unknown |
Information is unavailable |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Primary |
This indicates that the array controller should provide legacy boot support (Interrupt 13h BIOS support) for this logical drive. The logical drive will be listed as first in the LUN list returned via SCSI commands |
Secondary |
This indicates that the array controller should provide legacy boot support (Interrupt 13h BIOS support) for this logical drive. The logical drive will be listed as second in the LUN list returned via SCSI commands |
None |
Legacy boot not supported on this logical drive |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | True if encryption is currently enabled on this logical drive, false otherwise |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | True if volatile keys are enabled for encryption, false otherwise |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | True if volatile keys are backed up to a remote key manager, false if volatile keys are not backed up |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | The status of the encryption volatile keys |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
NoOp |
No operations are pending for the volatile keys |
BackupInProgress |
The volatile keys are being backed up to a remote key manager |
BackupAndSetInProgress |
The volatile keys are being set and being backed up to a remote key manager |
RestoreInProgress |
The volatile keys are being restored from a remote key manager |
DeleteInProgress |
The volatile keys are being removed |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | Label given to the logical drive |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | logical drive number |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
LogicalDriveStatusReasons
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Unknown |
The state of the logical drive is unknown |
Ok |
The logical drive is in normal operation mode |
Failed |
Indicates that more physical drives have failed than the fault tolerance mode of the logical drive can handle without data loss |
Unconfigured |
The logical drive is not configured |
Recovering |
The logical drive is using Interim Recovery Mode. In Interim Recovery Mode, at least one physical drive has failed, but the logical drive's fault tolerance mode lets the drive continue to operate with no data loss |
ReadyForRebuild |
The logical drive is ready for Automatic Data Recovery. A failed physical drive has been replaced, but the logical drive is still operating in Interim Recovery Mode |
Rebuilding |
The logical drive is currently doing Automatic Data Recovery, where fault tolerance algorithms restore data to the replacement drive |
WrongDrive |
The wrong physical drive was replaced after a failure |
BadConnect |
A physical drive is not responding |
Overheating |
The drive array enclosure that contains the logical drive is overheating. The drive array is still functional, but should be shutdown |
Shutdown |
The drive array enclosure that contains the logical drive has overheated. The logical drive is no longer functional |
Expanding |
The logical drive is currently undergoing a transformation (expansion, shrinkage or movement). During transformation, fault tolerance algorithms redistribute logical drive data according to the transformation operation selected |
NotAvailable |
The logical drive is currently unavailable. If a logical drive is expanding and the new configuration frees additional disk space, this free space can be configured into another logical volume. If this is done, the new volume will be set to not available |
QueuedForExpansion |
The logical drive is ready for transformation (expansion, shrinkage or movement). The logical drive is in the queue for transformation |
MultipathAccessDegraded |
Previously all disk drives of this logical drive had more than one I/O path to the controller, but now one or few of them have only one I/O path |
Erasing |
The logical drive is currently being erased |
PredictiveSpareRebuildReady |
The logical drive is ready to perform a predictive spare rebuild. The logical drive is in the queue for rebuild |
RapidParityInitInProgress |
The logical drive is currently undergoing rapid parity initialization (RPI). The logical drive is unavailable to the operating system during RPI and will be made available once RPI has completed |
RapidParityInitPending |
The logical drive is currently pending RPI and will be unavailable |
NoAccessEncryptedNoControllerKey |
The logical drive is currently encrypted and cannot be accessed because the array controller has not yet received the encryption key nor was it found in the controller's CSP NVRAM |
UnencryptedToEncryptedInProgress |
The logical drive is currently being transformed from unencrypted to encrypted and the volume is online. Data will be written unencrypted if the write is directed to an LBA range on th e logical drive that has not yet been migrated |
NewKeyRekeyInProgress |
The logical drive is currently encrypted and all data is currently being rekeyed with a new logical drive key using the background capacity expansion transformation task. The logical drive is online |
NoAccessEncryptedControllerEncryptionNotEnabled |
The logical drive is currently encrypted and cannot be accessed because the array controller does not have encryption enabled |
UnencryptedToEncryptedNotStarted |
The logical drive has received a request to transform from unencrypted to encrypted but this process has not yet started. The unencrypted logical drive is currently online |
NewLogDrvKeyRekeyRequestReceived |
The logical drive is encrypted and has received a request to rekey all data with a new logical drive encryption key. The logical drive is online |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | How the logical drive is being used |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Data |
The drive is being used as a storage drive |
Cache |
The drive is being used as a cache drive for a different storage drive |
SplitMirrorSetPrimary |
This drive is being used as the primary storage drive of a split mirror set after a Split Mirror Array has been performed |
SplitMirrorSetBackup |
This drive is being used as the backup storage drive of a split mirror set after a Split Mirror Array has been performed |
SplitMirrorSetBackupOrphan |
This drive was being used as the backup storage drive of a split mirror set that no longer exists |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | Type of the disk this logical drive is associated with. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
HDD |
Spinning disk hard drive. |
SSD |
Solid state disk. |
SMR |
Shingled Magnetic Recording. |
Mixed |
Contains both HDD and SSD. |
Unknown |
Information is unavailable |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | Parity initialization complete percentage for a parity based logical drive (e.g. RAID 5) |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | When creating a logical drive with a RAID level that requires parity, parity blocks can be initialized with two different methods |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Default |
Parity blocks are initialized in the background and the logical drive is available during this time |
Rapid |
Both data and parity blocks are initialized in the foreground and the logical drive will not be available to the operating system until initialization completes |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | OS partition information for the drive |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | The current RAID level configured on the logical drive |
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
0 |
There is no fault tolerance used on this logical drive |
1 |
Two sets of duplicate data is being stored on a pair of drives |
1ADM |
Three sets of duplicate data is being stored on a trio of drives |
10 |
Data is duplicated and striped across pairs of disk drives |
10ADM |
Data is duplicated and striped across trios of disk drives |
5 |
Fault tolerance is achieved by storing parity data across 3 or more disk drives |
50 |
Fault tolerance is achieved by storing parity data and striping the data across 6 or more disk drives |
6 |
Fault tolerance is achieved by storing multiple sets parity data across 4 or more disk drives |
60 |
Fault tolerance is achieved by storing multiple sets parity data and striping the data across 8 or more disk drives |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | The percent complete for a rebuild operation currently occurring on the logical drive |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | The state of the SmartCache cache. This is valid if this drive either is a cache drive, or has a cache drive attached to it |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Good |
The cache is functioning properly |
Limited |
The cache is functioning in a degraded mode, and may not be functioning at maximum performance |
DDRUnsafe |
The DDR is unsafe for the cache drive |
CacheLUNOffline |
The cache drive is offline |
PrimaryLUNOffline |
The primary logical drive that is being cached is offline |
Destroyed |
The cache is destroyed and not functional |
Flushing |
The cache drive is flushing |
Configuring |
The caching pair is being configured |
PairFailAtPowerup |
The primary and cache drive were unable to be paired at powerup |
Unknown |
The state of the cache is unknown |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive See the Redfish standard schema and specification for information on common Status object.
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | The strip size of the logical drive in bytes |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | The stripe size of the logical drive in bytes |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | The percent complete for any transformations the logical drive may be undergoing such as RAID migration, stripesize migration, capacity expansion etc. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageLogicalDrive.v2_3_0.HpeSmartStorageLogicalDrive
Description | An identifier (typically SCSI Inquiry based such as Inquiry VPD Page 0x83 NAA 64 identifier) used to uniquely identify this volume. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
@odata.type: "#HpeSmartStorageLogicalDriveCollection.HpeSmartStorageLogicalDriveCollection"
A Collection of HpeSmartStorageLogicalDrive resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/smartstorage/arraycontrollers/{item}/logicaldrives |
Link Name | Destination type |
---|---|
Members[] |
HpeSmartStorageLogicalDrive |
Member of HpeSmartStorageLogicalDriveCollection.HpeSmartStorageLogicalDriveCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeSmartStorageLogicalDriveCollection.HpeSmartStorageLogicalDriveCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeSmartStorageLogicalDriveCollection.HpeSmartStorageLogicalDriveCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeSmartStorageStorageEnclosure.v2_0_0.HpeSmartStorageStorageEnclosure"
The HpeSmartStorageStorageEnclosure resource describes the properties of the HPE Smart Storage controller,drives,and volumes.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/smartstorage/arraycontrollers/{item}/storageenclosures/{item} |
Member of HpeSmartStorageStorageEnclosure.v2_0_0.HpeSmartStorageStorageEnclosure
Description | The state of the Door Lock LED. When Lit, this indicates that the Enclosure should not be removed since the drives are currently in use. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Unknown |
The state of the Door Lock LED cannot be determined. |
Lit |
The Door Lock LED is lit. |
Off |
The Door Lock LED is off. |
Member of HpeSmartStorageStorageEnclosure.v2_0_0.HpeSmartStorageStorageEnclosure
Description | Number of drive bays supported within the storage enclosure |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageStorageEnclosure.v2_0_0.HpeSmartStorageStorageEnclosure
Description | Unique ID for the storage enclosure |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageStorageEnclosure.v2_0_0.HpeSmartStorageStorageEnclosure
Description | The state of the Fault LED. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Unknown |
The state of the Fault LED cannot be determined. |
Lit |
The Fault LED is lit. |
Off |
The Fault LED is off. |
FirmwareVersion.Current FirmwareVersion.Current.VersionString Member of HpeSmartStorageStorageEnclosure.v2_0_0.HpeSmartStorageStorageEnclosure
Description | This string represents the version of the firmware image. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageStorageEnclosure.v2_0_0.HpeSmartStorageStorageEnclosure
Description | The state of the indicator LED. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Unknown |
The state of the Indicator LED cannot be determined. |
Lit |
The Indicator LED is lit. |
Blinking |
The Indicator LED is blinking. |
Off |
The Indicator LED is off. |
Member of HpeSmartStorageStorageEnclosure.v2_0_0.HpeSmartStorageStorageEnclosure
Description | Location identifier |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageStorageEnclosure.v2_0_0.HpeSmartStorageStorageEnclosure
Description | Format for Location Identifier |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Controller:Box |
This format typically used in controller context where the drive would be identified using the controller port and JBOD box number |
SwitchPort:Box |
This format typically used in a SAS switch context where the drive would be identified using the switch port and JBOD box number |
SwitchPort:SwitchBay |
This format typically used in a SAS switch context where the drive would be identified using the switch port and ICM bay number for the switch |
Member of HpeSmartStorageStorageEnclosure.v2_0_0.HpeSmartStorageStorageEnclosure
Description | The manufacturer of the storage enclosure |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageStorageEnclosure.v2_0_0.HpeSmartStorageStorageEnclosure
Description | The model string for the storage enclosure |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageStorageEnclosure.v2_0_0.HpeSmartStorageStorageEnclosure
Description | Part number of this storage enclosure |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageStorageEnclosure.v2_0_0.HpeSmartStorageStorageEnclosure
Description | SKU for the storage enclosure |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageStorageEnclosure.v2_0_0.HpeSmartStorageStorageEnclosure
Description | The serial number for this storage enclosure |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeSmartStorageStorageEnclosure.v2_0_0.HpeSmartStorageStorageEnclosure See the Redfish standard schema and specification for information on common Status object.
Member of HpeSmartStorageStorageEnclosure.v2_0_0.HpeSmartStorageStorageEnclosure
Description | Location within the chassis if this storage enclosure is part of a larger chassis hosting multiple storage enclosures |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
@odata.type: "#HpeSmartStorageStorageEnclosureCollection.HpeSmartStorageStorageEnclosureCollection"
A Collection of HpeSmartStorageStorageEnclosure resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/smartstorage/arraycontrollers/{item}/storageenclosures |
Link Name | Destination type |
---|---|
Members[] |
HpeSmartStorageStorageEnclosure |
Member of HpeSmartStorageStorageEnclosureCollection.HpeSmartStorageStorageEnclosureCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeSmartStorageStorageEnclosureCollection.HpeSmartStorageStorageEnclosureCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeSmartStorageStorageEnclosureCollection.HpeSmartStorageStorageEnclosureCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeSNMPAlertDestination.v2_0_0.HpeSNMPAlertDestination"
The HpeSNMPAlertDestination resource describes the properties for SNMP Alert Destinations. The alert destination configuration up to 8 remote management systems that receive SNMP alerts from the BMC.
This resource type was added in iLO 5 1.20
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/snmpservice/snmpalertdestinations/{item} |
GET PATCH DELETE |
Member of HpeSNMPAlertDestination.v2_0_0.HpeSNMPAlertDestination
Description | The IP address or FQDN of remote management system that receive SNMP alerts. |
Type | string |
Read Only | False |
Added | iLO 5 1.20 |
Member of HpeSNMPAlertDestination.v2_0_0.HpeSNMPAlertDestination
Description | Indicate the SNMP protocol associated with the AlertDestination. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
SNMPv1Trap |
Indicate SNMPv1 trap is enabled for the destination. |
SNMPv3Trap |
Indicate SNMPv3 trap is enabled for the destination. Needs to fill the SecurityName as well. |
SNMPv3Inform |
Indicate SNMPv3 Inform is enabled for the destination. Needs to fill the SecurityName as well. |
Null |
A value is temporarily unavailable |
SNMPv3 User associated with the destination when SNMP alert protocol is SNMPv3trap.
SNMPv3User is a link ("@odata.id": URI
) to another resource.
Member of HpeSNMPAlertDestination.v2_0_0.HpeSNMPAlertDestination
Description | Provides the SNMPv3 security name associated with SNMPv3trap or SNMPv3Inform set on SNMPAlertProtocol. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
Member of HpeSNMPAlertDestination.v2_0_0.HpeSNMPAlertDestination
Description | The configured SNMPv1 trap community string. |
Type | string |
Read Only | False |
Added | iLO 5 1.20 |
@odata.type: "#HpeSNMPAlertDestinationCollection.HpeSNMPAlertDestinationCollection"
A Collection of HpeSNMPAlertDestination resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/snmpservice/snmpalertdestinations |
GET POST |
Link Name | Destination type |
---|---|
Members[] |
HpeSNMPAlertDestination |
Member of HpeSNMPAlertDestinationCollection.HpeSNMPAlertDestinationCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeSNMPAlertDestinationCollection.HpeSNMPAlertDestinationCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeSNMPAlertDestinationCollection.HpeSNMPAlertDestinationCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeSNMPUser.v2_1_0.HpeSNMPUser"
The HpeSNMPUser resource describes the properties for SNMP support. SNMPv3 supports the User-based Security Model (USM). With this model,security parameters are configured at both the agent level and the manager level. Messages exchanged between the agent and the manager are subject to a data integrity check and data origin authentication. Up to 8 user profiles are supported for setting SNMPv3 USM parameters.
This resource type was added in iLO 5 1.20
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/snmpservice/snmpusers/{item} |
GET PATCH DELETE |
Member of HpeSNMPUser.v2_1_0.HpeSNMPUser
Description | Sets the passphrase to use for sign operations. Enter a value of 8 to 49 characters. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
Member of HpeSNMPUser.v2_1_0.HpeSNMPUser
Description | Sets the message digest algorithm to use for encoding the authorization passphrase. The message digest is calculated over an appropriate portion of an SNMP message, and is included as part of the message sent to the recipient. |
Type | string |
Read Only | False |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
MD5 |
Indicate Message Digest Algorithm. |
SHA |
Indicate Secure Hash Algorithm. |
SHA256 |
Indicate SHA256 Algorithm. |
Member of HpeSNMPUser.v2_1_0.HpeSNMPUser
Description | Sets the passphrase to use for encrypt operations. Enter a value of 8 to 49 characters. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
Member of HpeSNMPUser.v2_1_0.HpeSNMPUser
Description | Sets the encryption algorithm to use for encoding the privacy passphrase. A portion of an SNMP message is encrypted before transmission. |
Type | string |
Read Only | False |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
DES |
Indicate Data Encryption Standard Algorithm. |
AES |
Indicate Advanced Encryption Standard Algorithm. |
Member of HpeSNMPUser.v2_1_0.HpeSNMPUser
Description | The user profile name. Enter an alphanumeric string of 1 to 32 characters. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
Member of HpeSNMPUser.v2_1_0.HpeSNMPUser
Description | The UserEngineID is combined with the SecurityName to create a SNMPv3 user for each manager. It is only used for creating remote accounts used with INFORM messages. If this property is not set then INFORM message will be sent with default or iLO configured engine ID. This value must be a hexadecimal string with an even number of 10 to 64 characters, excluding the first two characters, 0x (for example, 0x01020304abcdef). |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
@odata.type: "#HpeSNMPUsersCollection.HpeSNMPUsersCollection"
A Collection of HpeSNMPUsers resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/snmpservice/snmpusers |
GET POST |
Link Name | Destination type |
---|---|
Members[] |
HpeSNMPUser |
Member of HpeSNMPUsersCollection.HpeSNMPUsersCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeSNMPUsersCollection.HpeSNMPUsersCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeSNMPUsersCollection.HpeSNMPUsersCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeTlsConfig.v1_0_0.HpeTlsConfig"
The schema definition for TLS configuration.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/bios/tlsconfig |
GET |
/redfish/v1/systems/{item}/bios/tlsconfig/settings |
GET PATCH |
Link Name | Destination type |
---|---|
@Redfish.Settings/SettingsObject |
HpeTlsConfig |
Oem/Hpe/Links/BaseConfigs |
HpeBaseConfigs |
Member of HpeTlsConfig.v1_0_0.HpeTlsConfig See the Redfish standard schema and specification for information on common @Redfish properties.
Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Certificates
is an array containing elements of:
Certificates[{item}].FingerPrint Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | The fingerprint of the certificate. It is the sha256 (SHA2) of the Der format of the certificate |
Type | string |
Read Only | True |
Certificates[{item}].Issuer Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | The Issuer of the certificate |
Type | string |
Read Only | True |
Certificates[{item}].SerialNumber Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | The Serial Number of the certificate. |
Type | string |
Read Only | True |
Certificates[{item}].Subject Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | The Subject of the certificate. |
Type | string |
Read Only | True |
Certificates[{item}].ValidNotAfter Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | The expiration date of the certificate. |
Type | string |
Read Only | True |
Certificates[{item}].ValidNotBefore Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | The date when the certificate becomes valid. |
Type | string |
Read Only | True |
Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | The encryption used. It can have more than one type of encryption, example: "AES128-SHA:AES256-SHA:AES128-SHA256:AES256-SHA256" |
Type | string |
Read Only | False |
Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
DeleteCertificates
is an array containing elements of:
DeleteCertificates[{item}].FingerPrint Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | To delete a certificate, the user should place its fingerprint here. The fingerprint would be found as a property under the single certificate object in the "Certificates" array |
Type | string |
Read Only | False |
Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | Use this option to enable or disable verification of the connected server's hostname with the hostname in the certificate supplied by the server |
Type | string |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Disabled |
Disable verification of the connected server's hostname. |
Enabled |
enable verification of the connected server's hostname. |
Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
NewCertificates
is an array containing elements of:
NewCertificates[{item}].X509Certificate Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | the body (PEM format) of the Certificate to be added |
Type | string |
Read Only | False |
Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Type | string |
Read Only | True |
The following are the supported values:
Value |
---|
AUTO |
1.0 |
1.1 |
1.2 |
Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | The certificates count. |
Type | integer |
Read Only | False |
Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | It determines if/how the certificates are validated. |
Type | string |
Read Only | False |
The following are the supported values:
Value |
---|
NONE |
PEER |
@odata.type: "#HpeUSBDevice.v2_0_0.HpeUSBDevice"
The HpeUSBDevice resource describes the properties of USB devices.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/usbdevices/{item} |
GET |
Member of HpeUSBDevice.v2_0_0.HpeUSBDevice
Description | USB device usable capacity (if applicable) in Mbytes |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeUSBDevice.v2_0_0.HpeUSBDevice
Description | USB device Class code as defined by the USB HID device specification. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeUSBDevice.v2_0_0.HpeUSBDevice
Description | USB device name in UTF-8 format. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeUSBDevice.v2_0_0.HpeUSBDevice
Description | Protocol code as defined by the USB HID specification. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeUSBDevice.v2_0_0.HpeUSBDevice
Description | USB device SubClass code as defined by the USB HID device specification. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeUSBDevice.v2_0_0.HpeUSBDevice
Description | Location of the USB device on the server |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeUSBDevice.v2_0_0.HpeUSBDevice
Description | USB product ID as defined by manufacturer. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeUSBDevice.v2_0_0.HpeUSBDevice
Description | USB device structured name in UTF-8 format. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeUSBDevice.v2_0_0.HpeUSBDevice
Description | UEFI device path of USB device. Standardized text representation of the UEFI device path, in UTF-8 format |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeUSBDevice.v2_0_0.HpeUSBDevice
Description | Vendor ID of detected USB device. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
@odata.type: "#HpeUSBDevicesCollection.HpeUSBDevicesCollection"
A Collection of HpeUSBDevices resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/usbdevices |
GET |
Link Name | Destination type |
---|---|
Members[] |
HpeUSBDevice |
Member of HpeUSBDevicesCollection.HpeUSBDevicesCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeUSBDevicesCollection.HpeUSBDevicesCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeUSBDevicesCollection.HpeUSBDevicesCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeUSBPort.v2_0_0.HpeUSBPort"
The HpeUSBPort resource describes the properties of USB ports.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/usbports/{item} |
GET |
Member of HpeUSBPort.v2_0_0.HpeUSBPort
Description | Instance number of the USB Port |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeUSBPort.v2_0_0.HpeUSBPort
Description | Location of the USB Device on the server |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Back |
Located on the rear panel of the server. |
Front |
Located on the front bezel of the server. |
Internal |
Located internally within the server chassis. |
InternalManagement |
Internal management media. |
InternalSDCard |
The internal SD-Card slot. |
iLOManagement |
iLO virtual USB devices. |
Member of HpeUSBPort.v2_0_0.HpeUSBPort
Description | PCI Bus number of the USB controller that controls this USB port |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeUSBPort.v2_0_0.HpeUSBPort
Description | PCI Device Number of the USB Controller that controls this USB Port. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeUSBPort.v2_0_0.HpeUSBPort
Description | PCI Function Number of the USB Controller that controls this USB Port. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeUSBPort.v2_0_0.HpeUSBPort
Description | Parent Hub Instance that provides an instance number of the internal hub this USB Port is connected to. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of HpeUSBPort.v2_0_0.HpeUSBPort
Description | Shared Capability of the USB Port |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
UnsharedManagement |
Not shared as a Management Port. |
SharedManagementPhysicalSwitch |
Shared management port w/ physical switch to control whether muxed to iLO or host. |
SharedManagementPortAutomaticControl |
Member of HpeUSBPort.v2_0_0.HpeUSBPort
Description | USB speed capability of the USB port as configured by the BIOS during POST. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
USB1FullSpeed |
USB 1.0 Full Speed |
USB2HighSpeed |
USB 2.0 High Speed |
USB3SuperSpeed |
USB 3.x SuperSpeed |
Member of HpeUSBPort.v2_0_0.HpeUSBPort
Description | UEFI Device Path of USB Endpoint. Standardized text representation of the UEFI device path, in UTF-8 format |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
@odata.type: "#HpeUSBPortsCollection.HpeUSBPortsCollection"
A Collection of HpeUSBPorts resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/usbports |
GET |
Link Name | Destination type |
---|---|
Members[] |
HpeUSBPort |
Member of HpeUSBPortsCollection.HpeUSBPortsCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeUSBPortsCollection.HpeUSBPortsCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeUSBPortsCollection.HpeUSBPortsCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#HpeWorkloadPerformanceAdvisor.v1_0_0.HpeWorkloadPerformanceAdvisor"
The HpeWorkloadPerformanceAdvisor resource describes the properties for managing the HPE Workload Performance Advisor.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/workloadperformanceadvisor/{item} |
GET |
Member of HpeWorkloadPerformanceAdvisor.v1_0_0.HpeWorkloadPerformanceAdvisor
Description | Specifies the duration over which the workload performance advisor is computed. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of HpeWorkloadPerformanceAdvisor.v1_0_0.HpeWorkloadPerformanceAdvisor
PerformanceTuningOption
is an array containing elements of:
PerformanceTuningOption[{item}].BIOSAttributeName Member of HpeWorkloadPerformanceAdvisor.v1_0_0.HpeWorkloadPerformanceAdvisor
Description | The attribute name of the BIOS settings. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.40 |
PerformanceTuningOption[{item}].RecommendedValue Member of HpeWorkloadPerformanceAdvisor.v1_0_0.HpeWorkloadPerformanceAdvisor
Description | Recommended value for the corresponding BIOS attribute. Please refer to BIOS attribute registry schema for more information. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.40 |
Member of HpeWorkloadPerformanceAdvisor.v1_0_0.HpeWorkloadPerformanceAdvisor
WorkloadCharacteristics
is an array containing elements of:
WorkloadCharacteristics[{item}].MetricId Member of HpeWorkloadPerformanceAdvisor.v1_0_0.HpeWorkloadPerformanceAdvisor
Description | The id of the metric. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.40 |
WorkloadCharacteristics[{item}].MetricValue Member of HpeWorkloadPerformanceAdvisor.v1_0_0.HpeWorkloadPerformanceAdvisor
Description | The workload utilization of the metric. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Low |
Utilization is low. |
Medium |
Utilization is medium. |
High |
Utilization is high. |
@odata.type: "#HpeWorkloadPerformanceAdvisorCollection.HpeWorkloadPerformanceAdvisorCollection"
A Collection of HpeWorkloadPerformanceAdvisor resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/workloadperformanceadvisor |
GET |
Link Name | Destination type |
---|---|
Members[] |
v1_0_0 |
Member of HpeWorkloadPerformanceAdvisorCollection.HpeWorkloadPerformanceAdvisorCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeWorkloadPerformanceAdvisorCollection.HpeWorkloadPerformanceAdvisorCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of HpeWorkloadPerformanceAdvisorCollection.HpeWorkloadPerformanceAdvisorCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#JsonSchemaFileCollection.JsonSchemaFileCollection"
A Collection of JsonSchemaFile resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/jsonschemas |
GET |
Link Name | Destination type |
---|---|
Members[] |
JsonSchemaFile |
Member of JsonSchemaFileCollection.JsonSchemaFileCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of JsonSchemaFileCollection.JsonSchemaFileCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of JsonSchemaFileCollection.JsonSchemaFileCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#LogEntry.v1_1_0.LogEntry"
This resource defines the record format for a log. It is designed to be used for SEL logs (from IPMI) as well as Event Logs and OEM-specific log formats. The EntryType field indicates the type of log and the resource includes several additional properties dependent on the EntryType.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/logservices/iml/entries/{item} |
GET PATCH |
Member of LogEntry.v1_1_0.LogEntry
Description | The date and time when the log entry was created, for example, 2014-04-15T00:38:00Z. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
Member of LogEntry.v1_1_0.LogEntry
Description | The log entry type. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Oem |
Member of LogEntry.v1_1_0.LogEntry
Description | The log entry details. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of LogEntry.v1_1_0.LogEntry
Categories
is an array containing elements of:
Type | string or null |
Read Only | True |
The following are the supported values:
Value |
---|
Security |
Hardware |
Firmware |
Maintenance |
Administration |
Power |
Cooling |
Invalid User Input |
Other |
Configuration |
Member of LogEntry.v1_1_0.LogEntry
Description | The log entry event class. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of LogEntry.v1_1_0.LogEntry
Description | The log entry event class description. |
Type | string |
Read Only | True |
Member of LogEntry.v1_1_0.LogEntry
Description | The log entry event code. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of LogEntry.v1_1_0.LogEntry
Description | The occurrence count of the log entry. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of LogEntry.v1_1_0.LogEntry
Description | The destination host name or IP address of the remote server that recevied the service event. |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
Member of LogEntry.v1_1_0.LogEntry
Description | The event log identification number. Events are numbered in the order in which they are generated. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of LogEntry.v1_1_0.LogEntry
Description | The unique identifier of the service event. |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
Member of LogEntry.v1_1_0.LogEntry
Description | The link to troubleshooting information. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | uri-reference |
Member of LogEntry.v1_1_0.LogEntry
Description | The recommended action for the event. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of LogEntry.v1_1_0.LogEntry
Description | The repaired status of the IML event. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of LogEntry.v1_1_0.LogEntry
Description | The log entry event Severity. |
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Informational |
Informational event |
Caution |
Caution event |
Critical |
Critical event |
Repaired |
Critical or Caution event repaired |
Member of LogEntry.v1_1_0.LogEntry
Description | The service event log submission status . |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
Member of LogEntry.v1_1_0.LogEntry
Description | The date and time of the latest log entry update, for example, 2014-04-15T00:38:00Z. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
Member of LogEntry.v1_1_0.LogEntry
Description | The User action for the event. |
Type | string |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Repaired |
The event repaired by user. |
Ignored |
The event ignored by user. |
None |
No user action taken on the event. |
Not Applicable |
User action not applicable for the event. |
Member of LogEntry.v1_1_0.LogEntry
Description | The format of an OEM record. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Hpe-IML |
Hpe-iLOEventLog |
Hpe-SL |
Member of LogEntry.v1_1_0.LogEntry
Description | The log entry severity. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
OK |
Warning |
Critical |
@odata.type: "#LogEntryCollection.LogEntryCollection"
A Collection of LogEntry resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/logservices/iel/entries |
GET |
/redfish/v1/managers/{item}/remotesupportservice/serviceeventlogs |
GET |
/redfish/v1/systems/{item}/logservices/iml/entries |
GET POST |
Link Name | Destination type |
---|---|
Members[] |
LogEntry |
Member of LogEntryCollection.LogEntryCollection
Members
is an array containing elements of:
Members[{item}].@odata.context Member of LogEntryCollection.LogEntryCollection
Type | string |
Read Only | True |
Format | uri-reference |
Members[{item}].@odata.etag Member of LogEntryCollection.LogEntryCollection
Type | string |
Read Only | True |
Members[{item}].@odata.id Member of LogEntryCollection.LogEntryCollection
Type | string |
Read Only | True |
Format | uri-reference |
Members[{item}].@odata.type Member of LogEntryCollection.LogEntryCollection
Type | string |
Read Only | True |
Members[{item}].Created Member of LogEntryCollection.LogEntryCollection
Description | The date and time when the log entry was created, for example, 2014-04-15T00:38:00Z. |
Type | string |
Read Only | True |
Format | date-time |
Members[{item}].EntryType Member of LogEntryCollection.LogEntryCollection
Description | The log entry type. |
Type | string |
Read Only | True |
The following are the supported values:
Value |
---|
Oem |
Members[{item}].Message Member of LogEntryCollection.LogEntryCollection
Description | The log entry details. |
Type | string |
Read Only | True |
Members[{item}].Oem.Hpe.Categories (array)
Member of LogEntryCollection.LogEntryCollection
Categories
is an array containing elements of:
Type | string or null |
Read Only | True |
The following are the supported values:
Value |
---|
Security |
Hardware |
Firmware |
Maintenance |
Administration |
Power |
Cooling |
Invalid User Input |
Other |
Configuration |
Members[{item}].Oem.Hpe.Class Member of LogEntryCollection.LogEntryCollection
Description | The log entry event class. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Members[{item}].Oem.Hpe.ClassDescription Member of LogEntryCollection.LogEntryCollection
Description | The log entry event class description. |
Type | string |
Read Only | True |
Members[{item}].Oem.Hpe.Code Member of LogEntryCollection.LogEntryCollection
Description | The log entry event code. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Members[{item}].Oem.Hpe.Count Member of LogEntryCollection.LogEntryCollection
Description | The occurrence count of the log entry. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Members[{item}].Oem.Hpe.Destination Member of LogEntryCollection.LogEntryCollection
Description | The destination host name or IP address of the remote server that recevied the service event. |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
Members[{item}].Oem.Hpe.EventNumber Member of LogEntryCollection.LogEntryCollection
Description | The event log identification number. Events are numbered in the order in which they are generated. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Members[{item}].Oem.Hpe.Identifier Member of LogEntryCollection.LogEntryCollection
Description | The unique identifier of the service event. |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
Members[{item}].Oem.Hpe.LearnMoreLink Member of LogEntryCollection.LogEntryCollection
Description | The link to troubleshooting information. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | uri-reference |
Members[{item}].Oem.Hpe.RecommendedAction Member of LogEntryCollection.LogEntryCollection
Description | The recommended action for the event. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Members[{item}].Oem.Hpe.Repaired Member of LogEntryCollection.LogEntryCollection
Description | The repaired status of the IML event. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Members[{item}].Oem.Hpe.Severity Member of LogEntryCollection.LogEntryCollection
Description | The log entry event Severity. |
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Informational |
Informational event |
Caution |
Caution event |
Critical |
Critical event |
Repaired |
Critical or Caution event repaired |
Members[{item}].Oem.Hpe.SubmitStatus Member of LogEntryCollection.LogEntryCollection
Description | The service event log submission status . |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
Members[{item}].Oem.Hpe.Updated Member of LogEntryCollection.LogEntryCollection
Description | The date and time of the latest log entry update, for example, 2014-04-15T00:38:00Z. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
Members[{item}].Oem.Hpe.UserAction Member of LogEntryCollection.LogEntryCollection
Description | The User action for the event. |
Type | string |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Repaired |
The event repaired by user. |
Ignored |
The event ignored by user. |
None |
No user action taken on the event. |
Not Applicable |
User action not applicable for the event. |
Members[{item}].OemRecordFormat Member of LogEntryCollection.LogEntryCollection
Description | The format of an OEM record. |
Type | string |
Read Only | True |
The following are the supported values:
Value |
---|
Hpe-IML |
Hpe-iLOEventLog |
Hpe-SL |
Members[{item}].Severity Member of LogEntryCollection.LogEntryCollection
Description | The log entry severity. |
Type | string |
Read Only | True |
The following are the supported values:
Value |
---|
OK |
Warning |
Critical |
Member of LogEntryCollection.LogEntryCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#LogService.v1_0_0.LogService"
This resource contains properties for monitoring and configuring an event log service for the resource or service to which it is associated.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/logservices/iel |
GET POST |
/redfish/v1/systems/{item}/logservices/iml |
GET POST |
Link Name | Destination type |
---|---|
Entries |
Collection of LogEntry |
The URI to this log entries collection resource.
Entries is a link ("@odata.id": URI
) to another resource.
Member of LogService.v1_0_0.LogService
Description | The maximum number of log entries. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Member of LogService.v1_0_0.LogService
Description | When the log is full, the overwrite policy is enforced. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Unknown |
The overwrite policy is not known or is undefined. |
WrapsWhenFull |
When the log is full, new entries will overwrite previous entries. |
NeverOverwrites |
When the log is full, new entries are discarded. |
LogService.ClearLog Member of LogService.v1_0_0.LogService There are no parameters for this action.
@odata.type: "#LogServiceCollection.LogServiceCollection"
A Collection of LogService resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/logservices |
GET |
/redfish/v1/systems/{item}/logservices |
GET |
Link Name | Destination type |
---|---|
Members[] |
LogService |
Member of LogServiceCollection.LogServiceCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of LogServiceCollection.LogServiceCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of LogServiceCollection.LogServiceCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#Manager.v1_5_1.Manager"
The Manager resource describes a manager. Examples of managers are BMCs, Enclosure Managers, Management Controllers and other subsystems assigned manageability functions.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item} |
GET POST PATCH |
Link Name | Destination type |
---|---|
Oem/Hpe/Links/DateTimeService |
HpeiLODateTime |
Oem/Hpe/Links/RemoteSupport |
HpeRemoteSupport |
Links/ManagerForChassis[] |
Chassis |
VirtualMedia |
Collection of VirtualMedia |
LogServices |
Collection of LogService |
Links/ManagerInChassis |
Chassis |
EthernetInterfaces |
Collection of EthernetInterface |
Links/ManagerForServers[] |
ComputerSystem |
Oem/Hpe/Links/ActiveHealthSystem |
HpeiLOActiveHealthSystem |
Oem/Hpe/Links/SecurityService |
HpeSecurityService |
Oem/Hpe/Links/LicenseService |
Collection of HpeiLOLicense |
NetworkProtocol |
ManagerNetworkProtocol |
Oem/Hpe/Links/FederationPeers |
Collection of HpeiLOFederationPeers |
HostInterfaces |
Collection of HostInterface |
Oem/Hpe/Links/EmbeddedMediaService |
HpeiLOEmbeddedMedia |
Oem/Hpe/Links/FederationGroups |
Collection of HpeiLOFederationGroup |
Oem/Hpe/Links/BackupRestoreService |
HpeiLOBackupRestoreService |
CommandShell.ConnectTypesSupported (array)
Member of Manager.v1_5_1.Manager
ConnectTypesSupported
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
SSH |
The controller supports a Command Shell connection using the SSH protocol |
Telnet |
The controller supports a Command Shell connection using the Telnet protocol |
IPMI |
The controller supports a Command Shell connection using the IPMI Serial-over-LAN (SOL) protocol |
Oem |
The controller supports a Command Shell connectino using an OEM-specific protocol |
CommandShell.MaxConcurrentSessions Member of Manager.v1_5_1.Manager
Description | This is the maximum number of Command Shell sessions, regardless of protocol, that this manager supports. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
CommandShell.ServiceEnabled Member of Manager.v1_5_1.Manager
Description | Indicates if the Command Shell service is enabled for this manager. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of Manager.v1_5_1.Manager
Description | The current DateTime (with offset) for the manager, used to set or read time. |
Type | string or null |
Read Only | False |
Format | date-time |
Member of Manager.v1_5_1.Manager
Description | The time offset from UTC that the DateTime property is set to in format: +06:00 . |
Type | string or null |
Read Only | False |
This is a reference to a collection of NICs that this manager uses for network communication. It is here that clients will find NIC configuration options and settings.
EthernetInterfaces is a link ("@odata.id": URI
) to another resource.
Member of Manager.v1_5_1.Manager
Description | The firmware version of this Manager |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
GraphicalConsole.ConnectTypesSupported (array)
Member of Manager.v1_5_1.Manager
ConnectTypesSupported
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
KVMIP |
The controller supports a Graphical Console connection using a KVM-IP (redirection of Keyboard, Video, Mouse over IP) protocol |
Oem |
The controller supports a Graphical Console connection using an OEM-specific protocol |
GraphicalConsole.MaxConcurrentSessions Member of Manager.v1_5_1.Manager
Description | Indicates the maximum number of Graphical Console sessions, regardless of protocol, this manager supports. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
GraphicalConsole.ServiceEnabled Member of Manager.v1_5_1.Manager
Description | Indicates if the Command Shell service is enabled for this manager. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
This is a reference to a collection of Host Interfaces that this manager uses for local host communication. It is here that clients will find Host Interface configuration options and settings.
HostInterfaces is a link ("@odata.id": URI
) to another resource.
Reference to a resource of type Collection with a MemberType of Logs.
LogServices is a link ("@odata.id": URI
) to another resource.
Member of Manager.v1_5_1.Manager
Description | This property is the manager type for this resource. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
ManagementController |
A controller used primarily to monitor or manage the operation of a device or system |
EnclosureManager |
A controller which provides management functions for a chassis or group of devices or systems |
BMC |
A controller which provides management functions for a single computer system |
Member of Manager.v1_5_1.Manager
Description | Model name of the manager. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
This is a reference to the network services and their settings that the manager controls. It is here that clients will find network configuration options as well as network services.
NetworkProtocol is a link ("@odata.id": URI
) to another resource.
Member of Manager.v1_5_1.Manager
Description | Status of external provider data in NVRAM. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
DataPresent |
External Provider data is present in NVRAM. |
DataCleared |
External Provider data is not present in NVRAM. |
Member of Manager.v1_5_1.Manager
Description | State of the currently displayed configuration settings. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Current |
SomePendingReset |
Oem.Hpe.FederationConfig.IPv6MulticastScope Member of Manager.v1_5_1.Manager
Description | The IPv6 network scope of multicast announcements. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Link |
Site |
Organization |
Oem.Hpe.FederationConfig.MulticastAnnouncementInterval Member of Manager.v1_5_1.Manager
Description | The frequency in Seconds at which the iLO system announces itself on the network. A value of 0 disables multicast announcments. |
Type | integer |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Null |
30 |
60 |
120 |
300 |
600 |
900 |
1800 |
Oem.Hpe.FederationConfig.MulticastDiscovery Member of Manager.v1_5_1.Manager
Description | Enables or Disables Multicast Discovery for the local iLO system. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Enabled |
Disabled |
Oem.Hpe.FederationConfig.MulticastTimeToLive Member of Manager.v1_5_1.Manager
Description | The maximum number of switches a multicast announcement will traverse before being discarded. |
Type | integer |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.FederationConfig.iLOFederationManagement Member of Manager.v1_5_1.Manager
Description | Enables or Disables iLO Federation features for the local iLO system. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Enabled |
Disabled |
Oem.Hpe.Firmware.Backup Oem.Hpe.Firmware.Backup.BuildNumber Member of Manager.v1_5_1.Manager
Description | The build number of the firmware. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Backup.BuildNumberString Member of Manager.v1_5_1.Manager
Description | The string version of the build number of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Backup.Date Member of Manager.v1_5_1.Manager
Description | The build date of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Backup.DebugBuild Member of Manager.v1_5_1.Manager
Description | True if the firmware is a debug build; False if it is not. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Backup.Family Member of Manager.v1_5_1.Manager
Description | The family of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Backup.MajorVersion Member of Manager.v1_5_1.Manager
Description | The major version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Backup.MinorVersion Member of Manager.v1_5_1.Manager
Description | The minor version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Backup.Time Member of Manager.v1_5_1.Manager
Description | The build time of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Backup.VersionString Member of Manager.v1_5_1.Manager
Description | The version string of the firmware. This value might be null if VersionString is unavailable. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Bootblock Oem.Hpe.Firmware.Bootblock.BuildNumber Member of Manager.v1_5_1.Manager
Description | The build number of the firmware. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Bootblock.BuildNumberString Member of Manager.v1_5_1.Manager
Description | The string version of the build number of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Bootblock.Date Member of Manager.v1_5_1.Manager
Description | The build date of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Bootblock.DebugBuild Member of Manager.v1_5_1.Manager
Description | True if the firmware is a debug build; False if it is not. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Bootblock.Family Member of Manager.v1_5_1.Manager
Description | The family of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Bootblock.MajorVersion Member of Manager.v1_5_1.Manager
Description | The major version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Bootblock.MinorVersion Member of Manager.v1_5_1.Manager
Description | The minor version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Bootblock.Time Member of Manager.v1_5_1.Manager
Description | The build time of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Bootblock.VersionString Member of Manager.v1_5_1.Manager
Description | The version string of the firmware. This value might be null if VersionString is unavailable. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Current Oem.Hpe.Firmware.Current.BuildNumber Member of Manager.v1_5_1.Manager
Description | The build number of the firmware. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Current.BuildNumberString Member of Manager.v1_5_1.Manager
Description | The string version of the build number of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Current.Date Member of Manager.v1_5_1.Manager
Description | The build date of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Current.DebugBuild Member of Manager.v1_5_1.Manager
Description | True if the firmware is a debug build; False if it is not. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Current.Family Member of Manager.v1_5_1.Manager
Description | The family of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Current.MajorVersion Member of Manager.v1_5_1.Manager
Description | The major version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Current.MinorVersion Member of Manager.v1_5_1.Manager
Description | The minor version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Current.Time Member of Manager.v1_5_1.Manager
Description | The build time of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Current.VersionString Member of Manager.v1_5_1.Manager
Description | The version string of the firmware. This value might be null if VersionString is unavailable. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Pending Oem.Hpe.Firmware.Pending.BuildNumber Member of Manager.v1_5_1.Manager
Description | The build number of the firmware. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Pending.BuildNumberString Member of Manager.v1_5_1.Manager
Description | The string version of the build number of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Pending.Date Member of Manager.v1_5_1.Manager
Description | The build date of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Pending.DebugBuild Member of Manager.v1_5_1.Manager
Description | True if the firmware is a debug build; False if it is not. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Pending.Family Member of Manager.v1_5_1.Manager
Description | The family of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Pending.MajorVersion Member of Manager.v1_5_1.Manager
Description | The major version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Pending.MinorVersion Member of Manager.v1_5_1.Manager
Description | The minor version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Pending.Time Member of Manager.v1_5_1.Manager
Description | The build time of the firmware. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Firmware.Pending.VersionString Member of Manager.v1_5_1.Manager
Description | The version string of the firmware. This value might be null if VersionString is unavailable. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.FrontPanelUSB.State Member of Manager.v1_5_1.Manager
Description | The state of the front USB port device. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Ready |
iLO has not detected a front panel device. |
Busy |
iLO has detected a front panel device and is initializing or executing operations on the device. |
Complete |
iLO has successfully finished initializing or executing operations on the device. |
Error |
iLO failed to initialize or execute operations on the device. |
Disabled |
The front panel device is disabled by user configuration. |
Member of Manager.v1_5_1.Manager
Description | This setting specifies how long a user can be inactive before an iLO web interface ends automatically. |
Type | integer |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Null |
15 |
30 |
60 |
120 |
Oem.Hpe.IntegratedRemoteConsole.HotKeys (array)
Member of Manager.v1_5_1.Manager
HotKeys
is an array containing elements of:
HotKeys[{item}].KeySequence (array)
Member of Manager.v1_5_1.Manager
KeySequence
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
NONE |
No key |
ESC |
Escape key |
L_ALT |
Left Alt key |
R_ALT |
Right Alt key |
L_SHIFT |
Left Shift key |
R_SHIFT |
Right Shift key |
L_CTRL |
Left Control key |
R_CTRL |
Right Control key |
L_GUI |
Left Windows key |
R_GUI |
Right Windows key |
INS |
Insert key |
DEL |
Delete key |
HOME |
Home key |
END |
End key |
PG_UP |
Page Up key |
PG_DN |
Page Down key |
ENTER |
Enter key |
TAB |
Tab key |
BREAK |
Break key |
BACKSPACE |
Backspace key |
NUM_PLUS |
Num Plus key |
NUM_MINUS |
Num Minus key |
SCRL_LCK |
Scroll Lock key |
SYS_RQ |
Sys Rq key |
PRINT_SCRN |
|
F1 |
F1 key |
F2 |
F2 key |
F3 |
F3 key |
F4 |
F4 key |
F5 |
F5 key |
F6 |
F6 key |
F7 |
F7 key |
F8 |
F8 key |
F9 |
F9 key |
F10 |
F10 key |
F11 |
F11 key |
F12 |
F12 key |
SPACE |
Space key |
' |
Apostrophe key |
, |
Comma key |
- |
Hyphen key |
. |
Period key |
/ |
Slash key |
; |
Semicolon key |
= |
Equals key |
[ |
Left square bracket key |
\ |
Backslash key |
] |
Right square bracket key |
``````` | Backtick key |
0 |
0 key |
1 |
1 key |
2 |
2 key |
3 |
3 key |
4 |
4 key |
5 |
5 key |
6 |
6 key |
7 |
7 key |
8 |
8 key |
9 |
9 key |
a |
a key |
b |
b key |
c |
c key |
d |
d key |
e |
e key |
f |
f key |
g |
g key |
h |
h key |
i |
i key |
j |
j key |
k |
k key |
l |
l key |
m |
m key |
n |
n key |
o |
o key |
p |
p key |
q |
q key |
r |
r key |
s |
s key |
t |
t key |
u |
u key |
v |
v key |
w |
w key |
x |
x key |
y |
y key |
z |
z key |
Oem.Hpe.IntegratedRemoteConsole.LockKey
Oem.Hpe.IntegratedRemoteConsole.LockKey.CustomKeySequence (array)
Member of Manager.v1_5_1.Manager
CustomKeySequence
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
NONE |
No key |
ESC |
Escape key |
L_ALT |
Left Alt key |
R_ALT |
Right Alt key |
L_SHIFT |
Left Shift key |
R_SHIFT |
Right Shift key |
L_CTRL |
Left Control key |
R_CTRL |
Right Control key |
L_GUI |
Left Windows key |
R_GUI |
Right Windows key |
INS |
Insert key |
DEL |
Delete key |
HOME |
Home key |
END |
End key |
PG_UP |
Page Up key |
PG_DN |
Page Down key |
ENTER |
Enter key |
TAB |
Tab key |
BREAK |
Break key |
BACKSPACE |
Backspace key |
NUM_PLUS |
Num Plus key |
NUM_MINUS |
Num Minus key |
SCRL_LCK |
Scroll Lock key |
SYS_RQ |
Sys Rq key |
PRINT_SCRN |
|
F1 |
F1 key |
F2 |
F2 key |
F3 |
F3 key |
F4 |
F4 key |
F5 |
F5 key |
F6 |
F6 key |
F7 |
F7 key |
F8 |
F8 key |
F9 |
F9 key |
F10 |
F10 key |
F11 |
F11 key |
F12 |
F12 key |
SPACE |
Space key |
' |
Apostrophe key |
, |
Comma key |
- |
Hyphen key |
. |
Period key |
/ |
Slash key |
; |
Semicolon key |
= |
Equals key |
[ |
Left square bracket key |
\ |
Backslash key |
] |
Right square bracket key |
``````` | Backtick key |
0 |
0 key |
1 |
1 key |
2 |
2 key |
3 |
3 key |
4 |
4 key |
5 |
5 key |
6 |
6 key |
7 |
7 key |
8 |
8 key |
9 |
9 key |
a |
a key |
b |
b key |
c |
c key |
d |
d key |
e |
e key |
f |
f key |
g |
g key |
h |
h key |
i |
i key |
j |
j key |
k |
k key |
l |
l key |
m |
m key |
n |
n key |
o |
o key |
p |
p key |
q |
q key |
r |
r key |
s |
s key |
t |
t key |
u |
u key |
v |
v key |
w |
w key |
x |
x key |
y |
y key |
z |
z key |
Oem.Hpe.IntegratedRemoteConsole.LockKey.LockOption Member of Manager.v1_5_1.Manager
Description | Lock option setting. |
Type | string |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Windows |
This option configures iLO to lock a managed server running a Windows operating system. |
Custom |
This option configures iLO to use a custom key sequence to lock a managed server or log out a user on that server. |
Disabled |
This option disables the Remote Console Computer Lock feature. |
Oem.Hpe.IntegratedRemoteConsole.TrustedCertificateRequired Member of Manager.v1_5_1.Manager
Description | When this setting is enabled and a trusted SSL certificate has been imported into iLO, the .NET IRC is launched by using an HTTPS connection. When this setting is disabled, the .NET IRC is launched by using a non-SSL connection. |
Type | boolean |
Read Only | False |
Oem.Hpe.License.LicenseKey Member of Manager.v1_5_1.Manager
Description | The installed license key. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.License.LicenseString Member of Manager.v1_5_1.Manager
Description | Describes the type of license installed on management processor. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.License.LicenseType Member of Manager.v1_5_1.Manager
Description | Indicates whether the license is Perpetual or Evaluation. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of Manager.v1_5_1.Manager
Description | Persistent mouse and keyboard feature is enabled or not. When this feature is enabled, the iLO virtual mouse and keyboard are always connected to the iLO UHCI USB controller. When this feature is disabled, the iLO virtual mouse and keyboard are connected dynamically to the iLO UHCI controller only when a Remote Console application is open and connected to iLO. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.15 |
Member of Manager.v1_5_1.Manager
Description | This property enables or disables the display of Server Health Status on a physical monitor attached to the system. |
Type | boolean |
Read Only | False |
Member of Manager.v1_5_1.Manager
Description | This property enables or disables RIBCL for the management processor. The management processor will require reset when this field is modified. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of Manager.v1_5_1.Manager
Description | This property enables or disables the accessibility of remote console thumbnail image in iLO. Disabling this property will not disable remote console feature. |
Type | boolean |
Read Only | False |
Member of Manager.v1_5_1.Manager
Description | Determines whether authentication is required for host-based utilities which use CHIF (typically use of CHIF requires Administrator/root credentials) |
Type | boolean |
Read Only | False |
Member of Manager.v1_5_1.Manager
Description | Determines whether a user-credential prompt is displayed when a user accesses the iLO RBSU or the iLO Configuration Utility. The following settings are valid: Enabled-A login dialog box opens when a user accesses the iLO RBSU or the iLO Configuration Utility. Disabled (default)-No login is required when a user accesses the iLO RBSU or the iLO Configuration Utility. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of Manager.v1_5_1.Manager
Description | Serial command line interface speed in bits/second. |
Type | integer |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
9600 |
19200 |
38400 |
57600 |
115200 |
Member of Manager.v1_5_1.Manager
Description | Status of serial command line interface. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Disabled |
Serial command line interface is disabled. |
EnabledNoAuth |
Serial command line interface is enabled with no authentication required. |
EnabledAuthReq |
Serial command line interface is enabled with authentication required. |
Member of Manager.v1_5_1.Manager
Description | Indicates presence of UART hardware. |
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
NotPresent |
UART hardware present. |
Present |
UART hardware not present. |
Member of Manager.v1_5_1.Manager
Description | This property enables or disables logging to the downloadable Virtual Serial Port (VSP) log. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of Manager.v1_5_1.Manager
Description | This property enables or disables download of the downloadable Virtual Serial Port (VSP) log. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of Manager.v1_5_1.Manager
Description | This property controls video presence detection on the VGA port. True: firmware workaround detects some KVMs that are not automatically supported. False: hardware-based automatic video presence detection. |
Type | boolean |
Read Only | False |
Member of Manager.v1_5_1.Manager
Description | This indicates whether the VideoPresenceDetectOverride property is supported on this type of system. |
Type | boolean |
Read Only | True |
Member of Manager.v1_5_1.Manager
Description | Indicates whether the Virtual Network Interface is enabled or not. |
Type | boolean |
Read Only | False |
Member of Manager.v1_5_1.Manager
Description | This property enables or disables WEB GUI access for the management processor. The management processor will require reset when this field is modified. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of Manager.v1_5_1.Manager
Description | iLO functionality is enabled on this platform. |
Type | boolean |
Read Only | True |
Member of Manager.v1_5_1.Manager
Description | iLO functionality is required and can't be disabled on this platform (usually blades). |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of Manager.v1_5_1.Manager
Description | Specifies whether displaying the iLO network IP address during host server POST is enabled(default) or not. |
Type | boolean |
Read Only | False |
Member of Manager.v1_5_1.Manager
Description | Enables or disables the iLO Configuration Utility. The following settings are valid: Enabled (default)-On servers that support the iLO Configuration Utility, the iLO Configuration Utility is available when you access the UEFI System Utilities by pressing F9 during POST. Disabled-On servers that support the iLO Configuration Utility, the iLO Configuration Utility is not available when you access the UEFI System Utilities by pressing F9 during POST. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of Manager.v1_5_1.Manager
iLOSelfTestResults
is an array containing elements of:
iLOSelfTestResults[{item}].Notes Member of Manager.v1_5_1.Manager
Description | Additional Information (if any) about the Self Test. |
Type | string |
Read Only | True |
iLOSelfTestResults[{item}].SelfTestName Member of Manager.v1_5_1.Manager
Description | iLO Self Test Name. |
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
UnknownSelfTest |
UnknownSelfTest self test result. |
CryptographicHardware |
CryptographicHardware self test result. |
Memory |
Memory self test result. |
WebServerCryptography |
WebServerCryptography self test result. |
MiscCryptography |
MiscCryptography self test result. |
UART |
UART self test result. |
HoodSense |
Hood Sense self test result. |
NVRAMInterface |
NVRAMInterface self test result. |
NVRAMData |
NVRAMData self test result. |
NVRAMSpace |
NVRAM space self test result. |
NIC |
NIC self test result. |
EmbeddedFlash |
EmbeddedFlash or SD Card self test result. |
StaticRAM |
StaticRAM self test result. |
EEPROM |
EEPROM self test result. |
I2C |
I2C self test result. |
BootBlock |
BootBlock self test result. |
ThreadInit |
ThreadInit self test result. |
Infrastructure |
Infrastructure self test result. |
HostRom |
|
SupportedHost |
Supported Host self test result. |
EEPROMContent |
EEPROMContent self test result. |
PowerManagementController |
Power Management Controller self test result. |
CPLDPAL0 |
CPLD PAL0 self test result. |
CPLDPAL1 |
CPLD PAL1 self test result. |
CPLDPAL2 |
CPLD PAL2 self test result. |
CPLDPAL3 |
CPLD PAL3 self test result. |
CPLDPAL4 |
CPLD PAL4 self test result. |
CPLDPAL5 |
CPLD PAL5 self test result. |
ASICFuses |
ASIC Fuses self test result. |
iLOSelfTestResults[{item}].Status Member of Manager.v1_5_1.Manager See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.iLOServicePort.MassStorageAuthenticationRequired Member of Manager.v1_5_1.Manager
Description | Indicates whether mass storage authentication is required or not. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.iLOServicePort.USBEthernetAdaptersEnabled Member of Manager.v1_5_1.Manager
Description | Indicates whether the USB Ethernet Adapters are enabled or not. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.iLOServicePort.USBFlashDriveEnabled Member of Manager.v1_5_1.Manager
Description | Indicates whether the USB Flash Drive is enabled or not. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.iLOServicePort.iLOServicePortEnabled Member of Manager.v1_5_1.Manager
Description | Indicates whether the iLO Service Port is enabled or not. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of Manager.v1_5_1.Manager See the Redfish standard schema and specification for information on common Redundancy object.
SerialConsole.ConnectTypesSupported (array)
Member of Manager.v1_5_1.Manager
ConnectTypesSupported
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
SSH |
The controller supports a Serial Console connection using the SSH protocol |
Telnet |
The controller supports a Serial Console connection using the Telnet protocol |
IPMI |
The controller supports a Serial Console connection using the IPMI Serial-over-LAN (SOL) protocol |
Oem |
SerialConsole.MaxConcurrentSessions Member of Manager.v1_5_1.Manager
Description | This is the maximum number of Serial Console sessions, regardless of protocol, that this manager supports. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
SerialConsole.ServiceEnabled Member of Manager.v1_5_1.Manager
Description | Indicates if the Command Shell service is enabled for this manager. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of Manager.v1_5_1.Manager See the Redfish standard schema and specification for information on common Status object.
Member of Manager.v1_5_1.Manager
Description | This is a universally unique identifier that supervisory software uses to uniquely identify this manager. The UUID is assigned when the system is manufactured. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
This is a reference to the virtual media services for this manager.
VirtualMedia is a link ("@odata.id": URI
) to another resource.
Manager.Reset Member of Manager.v1_5_1.Manager
Parameters:
ResetType (string)
Value | Description |
---|---|
ForceRestart | |
GracefulRestart |
HpeiLO.ClearRestApiState Member of Manager.v1_5_1.Manager Clears the persistent state of the REST API. Some portions of the API may not be available until after the server reboots.
There are no parameters for this action.
HpeiLO.RequestFirmwareAndOsRecovery Member of Manager.v1_5_1.Manager Requests that the Recovery Install set be invoked, and when complete causes a OS reinstallation.
There are no parameters for this action.
HpeiLO.DisableiLOFunctionality Member of Manager.v1_5_1.Manager This action will disable the iLO network and will terminate communications with operating system drivers. To re-enable iLO functionality, use the iLO Configuration Utility (in the UEFI System Utilities) to set iLO Functionality to Enabled. For more information see the HPE UEFI System Utilities User Guide. The action resets/reboots the manager. iLO functionality cannot be disabled on server blades.
There are no parameters for this action.
HpeiLO.ClearHotKeys Member of Manager.v1_5_1.Manager Clear hot keys which are used during Remote Console sessions.
There are no parameters for this action.
HpeiLO.ResetToFactoryDefaults Member of Manager.v1_5_1.Manager Resets the iLO to Factory Defaults.
Parameters:
ResetType (string)
Value | Description |
---|---|
Default | Reset iLO to defaults, clear logs and reboot iLO. |
@odata.type: "#ManagerAccount.v1_1_3.ManagerAccount"
The user accounts, owned by a Manager, are defined in this resource. Changes to a Manager Account may affect the current Redfish service connection if this manager is responsible for the Redfish service.
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/accounts/{item} |
GET PATCH DELETE |
Member of ManagerAccount.v1_1_3.ManagerAccount
Description | Descriptive login name that helps to easily identify the owner of each user name. The login name does not have to be the same as the user name and must use printable characters. The maximum length for a user name is 39 characters. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.Privileges.HostBIOSConfigPriv Member of ManagerAccount.v1_1_3.ManagerAccount
Description | This privilege enables a user to configure Host Bios Settings. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.Privileges.HostNICConfigPriv Member of ManagerAccount.v1_1_3.ManagerAccount
Description | This privilege enables a user to configure Host NIC Settings. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.Privileges.HostStorageConfigPriv Member of ManagerAccount.v1_1_3.ManagerAccount
Description | This privilege enables a user to configure Host Storage Settings. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.Privileges.LoginPriv Member of ManagerAccount.v1_1_3.ManagerAccount
Description | This privilege enables a user to log in to management processor. All local accounts have the login privilege. This privilege is added automatically if it is not specified. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.Privileges.RemoteConsolePriv Member of ManagerAccount.v1_1_3.ManagerAccount
Description | This privilege enables a user to remotely access the host system Remote Console, including video, keyboard, and mouse control. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.Privileges.SystemRecoveryConfigPriv Member of ManagerAccount.v1_1_3.ManagerAccount
Description | This privilege enables a user to manage the critical recovery firmware images on the iLO Repository. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.Privileges.UserConfigPriv Member of ManagerAccount.v1_1_3.ManagerAccount
Description | This privilege enables a user to add, edit, and delete local management processor user accounts. A user with this privilege can change privileges for all users. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.Privileges.VirtualMediaPriv Member of ManagerAccount.v1_1_3.ManagerAccount
Description | This privilege enables a user to use the Virtual Media feature on the host system. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.Privileges.VirtualPowerAndResetPriv Member of ManagerAccount.v1_1_3.ManagerAccount
Description | This privilege enables a user to power-cycle or reset the host system. These activities interrupt system availability. A user with this privilege can diagnose the system by using the Generate NMI to System button. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.Privileges.iLOConfigPriv Member of ManagerAccount.v1_1_3.ManagerAccount
Description | This privilege enables a user to configure most management processor settings, including security settings, and to remotely update the management processor firmware. This privilege does not enable local user account administration. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of ManagerAccount.v1_1_3.ManagerAccount
Description | Indicate that the account type is service account |
Type | boolean |
Read Only | False |
Added | iLO 5 1.20 |
Member of ManagerAccount.v1_1_3.ManagerAccount
Description | The password used to log in to the management processor. The maximum length for a password is 39 characters. The minimum length for a password is specified in the MinPasswordLength property of the AccountService schema. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of ManagerAccount.v1_1_3.ManagerAccount
Description | This property contains the name of the Role for this account. |
Type | string |
Read Only | False |
Added | iLO 5 1.40 |
Member of ManagerAccount.v1_1_3.ManagerAccount
Description | The name used to log in to the management processor. The user name does not have to be the same as the login name. The maximum length for the user name is 39 characters. The user name must use printable characters. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
@odata.type: "#ManagerAccountCollection.ManagerAccountCollection"
A Collection of ManagerAccount resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/accounts |
GET POST |
Link Name | Destination type |
---|---|
Members[] |
ManagerAccount |
Member of ManagerAccountCollection.ManagerAccountCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of ManagerAccountCollection.ManagerAccountCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of ManagerAccountCollection.ManagerAccountCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#ManagerCollection.ManagerCollection"
A Collection of Manager resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers |
GET |
Link Name | Destination type |
---|---|
Members[] |
Manager |
Member of ManagerCollection.ManagerCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of ManagerCollection.ManagerCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of ManagerCollection.ManagerCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol"
This resource is used to obtain or modify the network services managed by this manager.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/networkprotocol |
GET POST PATCH |
Link Name | Destination type |
---|---|
Oem/Hpe/Links/SNMPService |
HpeiLOSnmpService |
Oem/Hpe/Links/EthernetInterfaces |
Collection of EthernetInterface |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The fully-qualified domain name of the manager that is obtained by DNS and includes the host name and top-level domain name. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
HTTP.Port Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The HTTP port number. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.10 |
HTTP.ProtocolEnabled Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether HTTP is enabled or disabled. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.10 |
HTTPS.Port Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The HTTPS/SSL port number. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.10 |
HTTPS.ProtocolEnabled Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether HTTPS/SSL is enabled or disabled. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The host name of the manager that is obtained by DNS and does not include any domain information. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
IPMI.Port Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The IPMI over LAN port number. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.10 |
IPMI.ProtocolEnabled Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether IPMI over LAN is enabled for the manager. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.10 |
KVMIP.Port Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The KVM-IP port number. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.10 |
KVMIP.ProtocolEnabled Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether KVM-IP is enabled for the manager. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The destination email address for email alerts. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether AlertMail is enabled. This can be enabled only when the properties AlertMailEmail, AlertMailSenderDomain and AlertMailSMTPServer are set or not empty. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether AlertMail SMTP Authentication is enabled. This can be enabled only when the properties AlertMailSMTPSecureEnabled, AlertMailSMTPAuthUser and AlertMailSMTPAuthPw are set or not empty. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.30 |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The password credential for SMTP server Authentication. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.30 |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The username credential for SMTP server Authentication. |
Type | string |
Read Only | False |
Added | iLO 5 1.30 |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The SMTP server port number. |
Type | integer |
Read Only | False |
Added | iLO 5 1.10 |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether AlertMail SMTP Secure Connection (SSL/TLS) is enabled. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.30 |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The IP address or DNS name of the SMTP server or the Mail Submission Agent (MSA). |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The domain name for the sender email address. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | State of the currently displayed configuration settings. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Current |
SomePendingReset |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether management processor federation management is enabled or disabled. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether management processor federation is supported. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether Remote Syslog is enabled. When enabled, management processor sends notification messages to the specified Syslog server. This can be enabled only when the property RemoteSyslogServer is set or not empty. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The port number through which the Syslog servers are listening. |
Type | integer |
Read Only | False |
Added | iLO 5 1.10 |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The IP address, FQDN, IPv6 name, or short name of the servers running the Syslog service. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The SNMP trap port number. |
Type | integer |
Read Only | False |
Added | iLO 5 1.10 |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether Serial Over LAN (SOL) or Virtual Serial Port (VSP) logging is enabled. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Enables or disables encryption on virtual media connections. |
Type | boolean |
Read Only | False |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Determines whether management processor responds to anonymous XML discovery requests. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
SNMP.Port Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The SNMP port number. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.10 |
SNMP.ProtocolEnabled Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether SNMP is enabled for the manager. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.10 |
SSDP.NotifyIPv6Scope Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The scope for IPv6 Notify messages for SSDP. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Link |
SSDP Notify messages are sent to addresses in the IPv6 Local Link scope |
Site |
SSDP Notify messages are sent to addresses in the IPv6 Local Site scope. |
Organization |
SSDP Notify messages are sent to addresses in the IPv6 Local Organization scope. |
SSDP.NotifyMulticastIntervalSeconds Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates how often multicast is performed for SSDP. Allowed values are 0, 30, 60, 120, 300, 600, 900 or 1800. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.10 |
SSDP.NotifyTTL Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The Time to Live (TTL) hop count for SSDP Notify messages. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.10 |
SSDP.Port Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The SSDP port number. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
SSDP.ProtocolEnabled Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether SSDP is enabled for the manager. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.10 |
SSH.Port Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The SSH port number. NOTE: When this field is modified, the Manager will reset automatically. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.10 |
SSH.ProtocolEnabled Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether SSH is enabled for the manager. NOTE: When this field is modified, the Manager will reset automatically. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol See the Redfish standard schema and specification for information on common Status object.
VirtualMedia.Port Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The Virtual Media port number. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.10 |
VirtualMedia.ProtocolEnabled Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether Virtual Media is enabled for the manager. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.10 |
HpeiLOManagerNetworkService.SendTestAlertMail Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol There are no parameters for this action.
HpeiLOManagerNetworkService.SendTestSyslog Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol There are no parameters for this action.
@odata.type: "#Memory.v1_7_1.Memory"
The Memory resource describes a memory module.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/memory/{item} |
GET |
Member of Memory.v1_7_1.Memory
Description | The boundary which memory regions are allocated on, measured in MiB. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of Memory.v1_7_1.Memory
Description | The size of the smallest unit of allocation for a memory region, thus it is the multiple in which regions are actually reserved. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of Memory.v1_7_1.Memory
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
RDIMM |
Registered DIMM |
UDIMM |
UDIMM |
SO_DIMM |
SO_DIMM |
LRDIMM |
Load Reduced |
Mini_RDIMM |
Mini_RDIMM |
Mini_UDIMM |
Mini_UDIMM |
SO_RDIMM_72b |
SO_RDIMM_72b |
SO_UDIMM_72b |
SO_UDIMM_72b |
SO_DIMM_16b |
SO_DIMM_16b |
SO_DIMM_32b |
SO_DIMM_32b |
Member of Memory.v1_7_1.Memory
Description | Bus Width in bits. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Memory.v1_7_1.Memory
Description | Total size of the cache portion memory in MiB. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of Memory.v1_7_1.Memory
Description | Memory Capacity in MiB. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Memory.v1_7_1.Memory
Description | Indicates that the configuration of this memory has been locked |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of Memory.v1_7_1.Memory
Description | Data Width in bits. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Memory.v1_7_1.Memory
Description | Device ID |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Memory.v1_7_1.Memory
Description | Location of the Memory in the platform |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Memory.v1_7_1.Memory
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
NoECC |
No ECC available |
SingleBitECC |
Single bit Data error can be corrected by ECC |
MultiBitECC |
Multi-bit Data errors can be corrected by ECC |
AddressParity |
Address Parity errors can be corrected |
Member of Memory.v1_7_1.Memory
Description | Version of API supported by the firmware |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of Memory.v1_7_1.Memory
Description | The firmware revision of this device |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Memory.v1_7_1.Memory
Description | Total size of the logical memory in MiB. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of Memory.v1_7_1.Memory
Description | The Memory manufacturer |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Memory.v1_7_1.Memory
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
DDR |
DDR |
DDR2 |
DDR2 |
DDR3 |
DDR3 |
DDR4 |
DDR4 |
DDR4_SDRAM |
DDR4 SDRAM |
DDR4E_SDRAM |
DDR4E SDRAM |
LPDDR4_SDRAM |
LPDDR4 SDRAM |
DDR3_SDRAM |
DDR3 SDRAM |
LPDDR3_SDRAM |
LPDDR3 SDRAM |
DDR2_SDRAM |
DDR2 SDRAM |
DDR2_SDRAM_FB_DIMM |
DDR2 SDRAM FB_DIMM |
DDR2_SDRAM_FB_DIMM_PROBE |
DDR2 SDRAM FB_DIMM PROBE |
DDR_SGRAM |
DDR SGRAM |
DDR_SDRAM |
DDR SDRAM |
ROM |
ROM |
SDRAM |
SDRAM |
EDO |
EDO |
FastPageMode |
Fast Page Mode |
PipelinedNibble |
Pipelined Nibble |
Logical |
Logical Non-volatile device. |
MemoryLocation.Channel Member of Memory.v1_7_1.Memory
Description | Channel number in which Memory is connected |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
MemoryLocation.MemoryController Member of Memory.v1_7_1.Memory
Description | Memory controller number in which Memory is connected |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
MemoryLocation.Slot Member of Memory.v1_7_1.Memory
Description | Slot number in which Memory is connected |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
MemoryLocation.Socket Member of Memory.v1_7_1.Memory
Description | Socket number in which Memory is connected |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Memory.v1_7_1.Memory
MemoryMedia
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
DRAM |
DRAM media |
NAND |
NAND media |
Intel3DXPoint |
Intel 3D XPoint media |
Proprietary |
Proprietary media |
Member of Memory.v1_7_1.Memory
Description | The manufacturer ID of the memory subsystem controller of this memory module. |
Type | string or null |
Read Only | True |
Member of Memory.v1_7_1.Memory
Description | The product ID of the memory subsystem controller of this memory module. |
Type | string or null |
Read Only | True |
Member of Memory.v1_7_1.Memory
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
DRAM |
DRAM |
NVDIMM_N |
NVDIMM_N as defined by JEDEC. |
NVDIMM_F |
NVDIMM_F as defined by JEDEC. |
NVDIMM_P |
NVDIMM_P as defined by JEDEC. |
IntelOptane |
The memory module is Intel Optane DC Persistent Memory and composed of a combination of non-volatile and volatile memory. |
Member of Memory.v1_7_1.Memory
Description | The manufacturer ID of this memory module. |
Type | string or null |
Read Only | True |
Member of Memory.v1_7_1.Memory
Description | The product ID of this memory module. |
Type | string or null |
Read Only | True |
Member of Memory.v1_7_1.Memory
Description | Total size of the non-volatile portion memory in MiB. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of Memory.v1_7_1.Memory
Description | Specifies the current backup-ready status of the NVDIMM_N if available. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Memory.v1_7_1.Memory
Attributes
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
HpeSmartMemory |
This DIMM is HPE Smart Memory |
HpeStandardMemory |
This DIMM is HPE Standard Memory |
HpeLogicalNVDIMM |
This DIMM is HPE Logical Memory. |
Member of Memory.v1_7_1.Memory
Type | string |
Read Only | True |
Added | iLO 5 1.30 |
The following are the supported values:
Value |
---|
BurstEDO |
FastPage |
Synchronous |
EDO |
LRDIMM |
RDRAM |
RDIMM |
UDIMM |
NVDIMM |
NVDIMM-N |
LRNVDIMM |
SO_RDIMM_72b |
SO_UDIMM_72b |
PMM |
Member of Memory.v1_7_1.Memory
Description | Number of blocks read for the lifetime of the Memory. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of Memory.v1_7_1.Memory
Description | Number of blocks written for the lifetime of the Memory. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of Memory.v1_7_1.Memory
Description | Specifies memory module status and whether the module in use. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Unknown |
The status of the DIMM is unknown. |
Other |
DIMM status that does not fit any of these definitions. |
NotPresent |
DIMM is not present. |
PresentUnused |
DIMM is present but unused. |
GoodInUse |
DIMM is functioning properly and currently in use. |
AddedButUnused |
DIMM is added but currently unused. |
UpgradedButUnused |
DIMM is upgraded but currently unused. |
ExpectedButMissing |
DIMM is expected but missing. |
DoesNotMatch |
DIMM type does not match. |
NotSupported |
DIMM is not supported. |
ConfigurationError |
Configuration error in DIMM. |
Degraded |
DIMM state is degraded. |
PresentSpare |
DIMM is present but used as spare. |
GoodPartiallyInUse |
DIMM is functioning properly but partially in use. |
MapOutConfiguration |
DIMM mapped out due to configuration error. |
MapOutError |
DIMM mapped out due to training failure. |
Member of Memory.v1_7_1.Memory
Description | Maximum capable speed of the device, in megatransfers per second (MT/s). |
Type | integer or null |
Read Only | True |
Member of Memory.v1_7_1.Memory
Description | The minimum DIMM voltage multiplied by 10, for example, 1.2v = 12. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Memory.v1_7_1.Memory
Description | The percentage of media life left. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Memory.v1_7_1.Memory
Description | friendly product name from SMBIOS 202 record |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of Memory.v1_7_1.Memory
RelatedBackupStores
is an array containing elements of:
RelatedBackupStores[{item}].@odata.id Member of Memory.v1_7_1.Memory
Type | string |
Read Only | True |
Format | uri-reference |
Member of Memory.v1_7_1.Memory
RelatedPhysicalDIMMs
is an array containing elements of:
RelatedPhysicalDIMMs[{item}].@odata.id Member of Memory.v1_7_1.Memory
Type | string |
Read Only | True |
Format | uri-reference |
Member of Memory.v1_7_1.Memory
RelatedPowerBackupUnitBays
is an array containing elements of:
Description | Battery backup unit bay number. |
Type | integer |
Read Only | True |
Member of Memory.v1_7_1.Memory
SPDBytes
is an array containing elements of:
Description | The SPD Bytes in the DIMM |
Type | integer |
Read Only | True |
Member of Memory.v1_7_1.Memory
Description | The percentage of the number of spare blocks remaining. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of Memory.v1_7_1.Memory
Description | Vendor Name decoded from VendorID |
Type | string or null |
Read Only | True |
Member of Memory.v1_7_1.Memory
OperatingMemoryModes
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Volatile |
Volatile memory |
PMEM |
Persistent memory, byte accesible through system address space |
Block |
Block accessible system memory |
Member of Memory.v1_7_1.Memory
Description | Operating speed of Memory in MHz |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Memory.v1_7_1.Memory
Description | The product part number of this device |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Memory.v1_7_1.Memory
Description | Total number of persistent regions this Memory can support. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of Memory.v1_7_1.Memory
Description | Total size of persistent regions in MiB |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Memory.v1_7_1.Memory
Description | Maximum size of a single persistent region in MiB. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of Memory.v1_7_1.Memory
Description | Number of ranks available in the Memory |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Memory.v1_7_1.Memory
Regions
is an array containing elements of:
Regions[{item}].MemoryClassification Member of Memory.v1_7_1.Memory
Description | Classification of memory occupied by the given memory region |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Volatile |
Volatile memory |
ByteAccessiblePersistent |
Byte accessible persistent memory |
Block |
Block accesible memory |
Regions[{item}].PassphraseEnabled Member of Memory.v1_7_1.Memory
Description | State of the passphrase for this region |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.40 |
Regions[{item}].RegionId Member of Memory.v1_7_1.Memory
Description | Unique region ID representing a specific region within the Memory |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
Regions[{item}].SizeMiB Member of Memory.v1_7_1.Memory
Description | Size of this memory region in MiB |
Type | number or null |
Read Only | True |
Added | iLO 5 1.40 |
SecurityCapabilities.ConfigurationLockCapable Member of Memory.v1_7_1.Memory
Description | Support for configuration locking |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.40 |
SecurityCapabilities.DataLockCapable Member of Memory.v1_7_1.Memory
Description | Support for data locking |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.40 |
SecurityCapabilities.PassphraseCapable Member of Memory.v1_7_1.Memory
Description | Memory passphrase set capability |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.40 |
SecurityCapabilities.PassphraseLockLimit Member of Memory.v1_7_1.Memory
Description | Maximum number of incorrect passphrase attempts allowed before memory is locked. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of Memory.v1_7_1.Memory
Description | The current security state of this Memory |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
Secure mode is enabled and access to the data is unlocked |
Disabled |
Secure mode is disabled |
Locked |
Secure mode is enabled and access to the data is locked |
Passphraselimit |
Number of attempts to unlock the Memory exceeded limit |
Member of Memory.v1_7_1.Memory
Description | The serial number of this device |
Type | string or null |
Read Only | True |
Added | iLO 5 1.15 |
Member of Memory.v1_7_1.Memory See the Redfish standard schema and specification for information on common Status object.
Member of Memory.v1_7_1.Memory
Description | Subsystem Device ID |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Memory.v1_7_1.Memory
Description | SubSystem Vendor ID |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Memory.v1_7_1.Memory
Description | Vendor ID |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Memory.v1_7_1.Memory
Description | Total number of volatile regions this Memory can support. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of Memory.v1_7_1.Memory
Description | Total size of volatile regions in MiB |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Memory.v1_7_1.Memory
Description | Maximum size of a single volatile region in MiB. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of Memory.v1_7_1.Memory
Description | Total size of the volitile portion memory in MiB. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.40 |
@odata.type: "#MemoryChunks.v1_2_2.MemoryChunks"
The MemoryChunks resource describes a Memory Chunk and its configuration.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/memorydomains/{item}/memorychunks/{item} |
GET |
Member of MemoryChunks.v1_2_2.MemoryChunks
Description | Memory type of this memory chunk |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
PMEM |
Byte accessible persistent memory |
Member of MemoryChunks.v1_2_2.MemoryChunks
InterleaveSets
is an array containing elements of:
InterleaveSets[{item}].Memory
Describes a memory device of the interleave set.
Memory is a link ("@odata.id": URI
) to another resource.
InterleaveSets[{item}].MemoryLevel Member of MemoryChunks.v1_2_2.MemoryChunks
Description | Level of the interleave set for multi-level tiered memory. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.40 |
InterleaveSets[{item}].OffsetMiB Member of MemoryChunks.v1_2_2.MemoryChunks
Description | Offset within the DIMM that corresponds to the start of this memory region, with units in MiB |
Type | number or null |
Read Only | True |
Added | iLO 5 1.40 |
InterleaveSets[{item}].RegionId Member of MemoryChunks.v1_2_2.MemoryChunks
Description | DIMM region identifier |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
InterleaveSets[{item}].SizeMiB Member of MemoryChunks.v1_2_2.MemoryChunks
Description | Size of this memory region in MiB |
Type | number or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of MemoryChunks.v1_2_2.MemoryChunks
Description | Mirror Enabled status |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of MemoryChunks.v1_2_2.MemoryChunks
Description | Spare enabled status |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of MemoryChunks.v1_2_2.MemoryChunks
Description | Size of the memory chunk in MiB |
Type | number or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of MemoryChunks.v1_2_2.MemoryChunks
Description | Size of chunk in percent of total capacity. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.40 |
Member of MemoryChunks.v1_2_2.MemoryChunks See the Redfish standard schema and specification for information on common Status object.
@odata.type: "#MemoryChunksCollection.MemoryChunksCollection"
A Collection of MemoryChunks resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/memorydomains/{item}/memorychunks |
GET |
Link Name | Destination type |
---|---|
Members[] |
MemoryChunks |
Member of MemoryChunksCollection.MemoryChunksCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of MemoryChunksCollection.MemoryChunksCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of MemoryChunksCollection.MemoryChunksCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#MemoryCollection.MemoryCollection"
A Collection of Memory resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/memory |
GET |
Link Name | Destination type |
---|---|
Members[] |
Memory |
Member of MemoryCollection.MemoryCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of MemoryCollection.MemoryCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of MemoryCollection.MemoryCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Member of MemoryCollection.MemoryCollection
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Unknown |
The management software cannot determine the AMP, host OS may not have provided it yet. |
Other |
|
None |
The management software cannot determine the AMP, or the system is not configured for AMP. |
Mirroring |
The system is configured for mirrored memory protection. All memory banks are duplicated in mirrored memory, as opposed to only one for online spare memory. If enough ECC errors occur, the spare memory is activated and the memory that is experiencing the errors is disabled. |
OnlineSpare |
A single spare bank of memory is set aside at boot time. If enough ECC errors occur, the spare memory is activated and the memory that is experiencing the errors is disabled. |
RAIDXOR |
The system is configured for AMP with the XOR engine. |
AdvancedECC |
The system is configured for AMP with the Advanced ECC engine. |
Lockstep |
|
A3DC |
The system is configured for AMP with A3DC. |
DIMMECC |
The system is configured for AMP with DIMM ECC (Error Correcting Code) only. |
Member of MemoryCollection.MemoryCollection
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Unknown |
The management software cannot determine the status, host OS may not have provided it yet. |
Other |
The system does not support AMP, or the management software cannot determine the status. |
NotProtected |
The system supports AMP, but the feature is disabled. |
Protected |
The system supports AMP. The feature is enabled but not engaged. |
Degraded |
The system was protected, but AMP is engaged. Therefore, AMP is no longer available. |
DIMMECC |
The system is protected by DIMM ECC (Error Correcting Code) only. |
Mirroring |
The system is protected by AMP in the mirrored mode. No DIMM faults have been detected. |
DegradedMirroring |
The system is protected by AMP in the mirrored mode. One or more DIMM faults have been detected. |
OnlineSpare |
The system is protected by AMP in the hot spare mode. No DIMM faults have been detected. |
DegradedOnlineSpare |
|
RAIDXOR |
The system is protected by AMP in the XOR memory mode. No DIMM faults have been detected. |
DegradedRAIDXOR |
The system is protected by AMP in the XOR memory mode. One or more DIMM faults have been detected. |
AdvancedECC |
The system is protected by AMP in the Advanced ECC mode. |
DegradedAdvancedECC |
The system is protected by AMP in the Advanced ECC mode. One or more DIMM faults have been detected. |
Lockstep |
|
DegradedLockstep |
|
A3DC |
The system is protected by AMP in the A3DC mode. |
DegradedA3DC |
The system is protected by AMP in the A3DC mode. One or more DIMM faults have been deteced. |
Member of MemoryCollection.MemoryCollection
AmpModeSupported
is an array containing elements of:
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
RAIDXOR |
The system can be configured for AMP using the XOR engine. |
DualBoardMirroring |
The system can be configured for mirrored advanced memory protection in a dual memory board configuration. The mirrored memory can be swapped with memory on the same memory board or with memory on the second memory board. |
SingleBoardMirroring |
The system can be configured for mirrored advanced memory protection in a single memory board. |
AdvancedECC |
The system can be configured for Advanced ECC. |
Mirroring |
The system can be configured for mirrored AMP. |
OnlineSpare |
The system can be configured for online spare AMP. |
OnlineSpareRank |
The system can be configured for Online Spare Rank AMP. |
OnlineSpareChannel |
The system can be configured for Online Spare Channel AMP. |
IntersocketMirroring |
The system can be configured for mirrored intersocket AMP between the memory of two processors or boards. |
IntrasocketMirroring |
The system can be configured for mirrored intrasocket AMP between the memory of a single processor or board. |
Lockstep |
|
A3DC |
The system can be configured for A3DC. |
None |
The system cannot be configured for AMP. |
DIMMECC |
The system can be configured for DIMM ECC (Error Correcting Code) only. |
Member of MemoryCollection.MemoryCollection
MemoryList
is an array containing elements of:
MemoryList[{item}].BoardCpuNumber Member of MemoryCollection.MemoryCollection
Type | integer or null |
Read Only | True |
MemoryList[{item}].BoardNumberOfSockets Member of MemoryCollection.MemoryCollection
Description | The number of present memory module sockets. |
Type | integer or null |
Read Only | True |
MemoryList[{item}].BoardOperationalFrequency Member of MemoryCollection.MemoryCollection
Description | The frequency at which memory on the board is operating in MHz. |
Type | integer or null |
Read Only | True |
MemoryList[{item}].BoardOperationalVoltage Member of MemoryCollection.MemoryCollection
Description | The voltage at which memory on the board is operating in mV. |
Type | integer or null |
Read Only | True |
MemoryList[{item}].BoardTotalMemorySize Member of MemoryCollection.MemoryCollection
Description | The total size of the memory populated on the board in MB. |
Type | integer or null |
Read Only | True |
@odata.type: "#MemoryDomain.v1_2_1.MemoryDomain"
The MemoryDomain resource describes a Memory Domain and its configuration. Memory Domains are used to indicate to the client which Memory (DIMMs) can be grouped together in Memory Chunks to form interleave sets or otherwise grouped together.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/memorydomains/{item} |
GET |
Member of MemoryDomain.v1_2_1.MemoryDomain
Description | Indicates if this Memory Domain supports the provisioning of blocks of memory. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of MemoryDomain.v1_2_1.MemoryDomain
Description | Indicates if this Memory Domain supports the creation of Memory Chunks. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of MemoryDomain.v1_2_1.MemoryDomain
Description | Indicates if this Memory Domain supports the creation of Memory Chunks with mirroring enabled. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of MemoryDomain.v1_2_1.MemoryDomain
Description | Indicates if this Memory Domain supports the creation of Memory Chunks with sparing enabled. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of MemoryDomain.v1_2_1.MemoryDomain
InterleavableMemorySets
is an array containing elements of:
InterleavableMemorySets[{item}].MemorySet (array)
Member of MemoryDomain.v1_2_1.MemoryDomain
MemorySet
is an array containing elements of:
MemorySet[{item}].@odata.id Member of MemoryDomain.v1_2_1.MemoryDomain
Type | string |
Read Only | True |
Format | uri-reference |
InterleavableMemorySets[{item}].MemorySet@odata.count Member of MemoryDomain.v1_2_1.MemoryDomain
Type | string |
Read Only | True |
Format | uri-reference |
A reference to the collection of Memory Chunks associated with this Memory Domain.
MemoryChunks is a link ("@odata.id": URI
) to another resource.
@odata.type: "#MemoryDomainCollection.MemoryDomainCollection"
A Collection of MemoryDomain resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/memorydomains |
GET |
Link Name | Destination type |
---|---|
Members[] |
MemoryDomain |
Member of MemoryDomainCollection.MemoryDomainCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of MemoryDomainCollection.MemoryDomainCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of MemoryDomainCollection.MemoryDomainCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#MessageRegistryFileCollection.MessageRegistryFileCollection"
A Collection of MessageRegistryFile resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/registries |
GET |
Link Name | Destination type |
---|---|
Members[] |
MessageRegistryFile |
Member of MessageRegistryFileCollection.MessageRegistryFileCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of MessageRegistryFileCollection.MessageRegistryFileCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of MessageRegistryFileCollection.MessageRegistryFileCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#MetricDefinition.v1_0_0.MetricDefinition"
The metadata information about a metric.
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/metricdefinitions/{item} |
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | The types of calculations which can be applied to the metric reading. This property provides information to the client on the suitability of calculatiion using the metric reading. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
NonCalculatable |
No calculations should be performed on the metric reading. |
Summable |
The sum of the metric reading across multiple instances is meaningful. |
NonSummable |
The sum of the metric reading across multiple instances is not meaningful. |
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | The calculation which is performed on a source metric to obtain the metric being defined. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Average |
The metric is calculated as the average of a metric reading over a sliding time interval. |
Maximum |
The metric is calculated as the maximum value of a metric reading over during a time interval. |
Minimum |
The metric is calculated as the minimum value of a metric reading over a sliding time interval. |
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | The implementation of the metric. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
PhysicalSensor |
The metric is implemented as a physical sensor. |
Calculated |
The metric is implemented by applying a calculation on another metric property. The calculation is specified in the CalculationAlgorithm property. |
Synthesized |
The metric is implemented by applying a calculation on one or more metric properties. (The calculation is not specified. For expressing generalized formula, see MathSON). |
DigitalMeter |
The metric is implemented as digital meter. |
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | Indicates whether the metric values are linear (vs non-linear). |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.40 |
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | Maximum value for metric reading. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | The data type of the related metric values. The property provides information to the client on the nature of the metric reading. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Boolean |
The data type follows the JSON Boolean definition. |
DateTime |
The data type follows the JSON String definition with the Date-Time format applied. |
Decimal |
The data type follows the JSON Decimal definition. |
Integer |
The data type follows the JSON Integer definition. |
String |
The data type follows the JSON String definition. |
Enumeration |
The data type follows the JSON String definition with a set of enumerations defined. |
Member of MetricDefinition.v1_0_0.MetricDefinition
MetricProperties
is an array containing elements of:
Type | string or null |
Read Only | True |
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | Specifies the type of metric provided. The property provides information to the client on how the metric can be handled. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Numeric |
The metric is a numeric metric. The metric value is any real number. |
Discrete |
The metric is a discrete metric. The metric value is discrete. The possible values are listed in the DiscreteValues property. |
Gauge |
The metric is a gauge metric. The metric value is a real number. When the metric value reaches the gauges extrema, it stays at that value, until the reading falls within the extrema. |
Counter |
The metric is a counter metric. The metric reading is a non-negative integer which increases monotonically. When a counter reaches its maximum, the value resets to 0 and resumes counting. |
Countdown |
The metric is a countdown metric. The metric reading is a non-negative integer which decreases monotonically. When a counter reaches its minimum, the value resets to preset value and resumes counting down. |
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | Minimum value for metric reading. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | The units of measure for this metric. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.40 |
@odata.type: "#MetricDefinitionCollection.MetricDefinitionCollection"
A Collection of MetricDefinition resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/metricdefinitions |
Link Name | Destination type |
---|---|
Members[] |
MetricDefinition |
Member of MetricDefinitionCollection.MetricDefinitionCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of MetricDefinitionCollection.MetricDefinitionCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of MetricDefinitionCollection.MetricDefinitionCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#MetricReport.v1_0_0.MetricReport"
The metric definitions used to create a metric report.
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/metricreports/{item} |
The metric definitions used to create a metric report.
MetricReportDefinition is a link ("@odata.id": URI
) to another resource.
Member of MetricReport.v1_0_0.MetricReport
MetricValues
is an array containing elements of:
MetricValues[{item}].MetricDefinition
A link to the Metric Definition.
MetricDefinition is a link ("@odata.id": URI
) to another resource.
MetricValues[{item}].MetricId Member of MetricReport.v1_0_0.MetricReport
Description | The metric definitions identifier for this metric. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
MetricValues[{item}].MetricValue Member of MetricReport.v1_0_0.MetricReport
Description | The value identifies this resource. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
MetricValues[{item}].Timestamp Member of MetricReport.v1_0_0.MetricReport
Description | The time when the value of the metric is obtained. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
Format | date-time |
@odata.type: "#MetricReportCollection.MetricReportCollection"
A Collection of MetricReport resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/metricreports |
Link Name | Destination type |
---|---|
Members[] |
MetricReport |
Member of MetricReportCollection.MetricReportCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of MetricReportCollection.MetricReportCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of MetricReportCollection.MetricReportCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#MetricReportDefinition.v1_0_0.MetricReportDefinition"
A set of metrics that are collected into a metric report.
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/metricreportdefinitions/{item} |
Member of MetricReportDefinition.v1_0_0.MetricReportDefinition
MetricProperties
is an array containing elements of:
Type | string or null |
Read Only | True |
Specifies the location where the resultant metric report is placed.
MetricReport is a link ("@odata.id": URI
) to another resource.
Member of MetricReportDefinition.v1_0_0.MetricReportDefinition
Description | Indicates when the metric report is generated. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Periodic |
The metric report is generated at a periodic time interval, specified in the Schedule property. |
OnChange |
The metric report is generated when any of the metric values change. |
OnRequest |
The metric report is generated when a HTTP GET is performed on the specified metric report. |
Member of MetricReportDefinition.v1_0_0.MetricReportDefinition
Metrics
is an array containing elements of:
Metrics[{item}].CollectionDuration Member of MetricReportDefinition.v1_0_0.MetricReportDefinition
Description | Specifies the duration over which the function is computed. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.40 |
Metrics[{item}].CollectionFunction Member of MetricReportDefinition.v1_0_0.MetricReportDefinition
Description | Specifies the function to apply to the list of metric properties. |
Type | string |
Read Only | False |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Average |
The metric is calculated as the average of a metric reading over a sliding time interval. |
Maximum |
The metric is calculated as the maximum value of a metric reading over during a time interval. |
Minimum |
The metric is calculated as the minimum value of a metric reading over a sliding time interval. |
Summation |
The metric is calculated as the sum of the values over a sliding time interval. |
Metrics[{item}].CollectionTimeScope Member of MetricReportDefinition.v1_0_0.MetricReportDefinition
Description | The time scope of the related metric values. |
Type | string |
Read Only | False |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Point |
The corresponding metric values apply to a point in time. On the corresponding metric value instances, the value of Timestamp shall specify the point in time. |
Interval |
The corresponding metric values apply to a time interval. On the corresponding metric value instances, the value of Timestamp shall specify the end of the time interval and Duration shall specify its duration. |
StartupInterval |
The corresponding metric values apply to a time interval that began at the startup of the measured resource (i.e. the Resources associated by Links.MetricDefinitionForResources). On the corresponding metric value instances, the value of Timestamp shall specify the end of the time interval. The value of Duration shall specifies the duration between startup of the resource and TimeStamp. |
Metrics[{item}].MetricId Member of MetricReportDefinition.v1_0_0.MetricReportDefinition
Description | Specifies the label for the metric definition which is derived by applying the CollectionFunction to the metric property. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
Metrics[{item}].MetricProperties (array)
Member of MetricReportDefinition.v1_0_0.MetricReportDefinition
MetricProperties
is an array containing elements of:
Type | string or null |
Read Only | True |
Member of MetricReportDefinition.v1_0_0.MetricReportDefinition See the Redfish standard schema and specification for information on common Status object.
@odata.type: "#MetricReportDefinitionCollection.MetricReportDefinitionCollection"
A Collection of MetricReportDefinition resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/metricreportdefinitions |
Link Name | Destination type |
---|---|
Members[] |
MetricReportDefinition |
Member of MetricReportDefinitionCollection.MetricReportDefinitionCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of MetricReportDefinitionCollection.MetricReportDefinitionCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of MetricReportDefinitionCollection.MetricReportDefinitionCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#NetworkAdapter.v1_3_0.NetworkAdapter"
A NetworkAdapter represents the physical network adapter capable of connecting to a computer network. Examples include but are not limited to Ethernet, Fibre Channel, and converged network adapters.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/networkadapters/{item} |
GET |
/redfish/v1/chassis/{item}/networkadapters/{item}/Settings |
GET POST PATCH |
Member of NetworkAdapter.v1_3_0.NetworkAdapter
Controllers
is an array containing elements of:
Controllers[{item}].ControllerCapabilities Controllers[{item}].ControllerCapabilities.DataCenterBridging Controllers[{item}].ControllerCapabilities.DataCenterBridging.Capable Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The value of this property shall be a boolean indicating whether this controller is capable of Data Center Bridging (DCB). |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Controllers[{item}].ControllerCapabilities.NPAR Controllers[{item}].ControllerCapabilities.NPAR.NparCapable Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | Indicates whether or not NIC function partitioning is supported by a controller. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.40 |
Controllers[{item}].ControllerCapabilities.NPAR.NparEnabled Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | When true, NIC function partitioning is active on this controller. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.40 |
Controllers[{item}].ControllerCapabilities.NPIV Controllers[{item}].ControllerCapabilities.NPIV.MaxDeviceLogins Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The maximum number of N_Port ID Virtualization (NPIV) logins allowed simultaneously from all ports on this controller. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.20 |
Controllers[{item}].ControllerCapabilities.NPIV.MaxPortLogins Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The maximum number of N_Port ID Virtualization (NPIV) logins allowed per physical port on this controller. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.20 |
Controllers[{item}].ControllerCapabilities.NetworkDeviceFunctionCount Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The maximum number of physical functions available on this controller. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.20 |
Controllers[{item}].ControllerCapabilities.NetworkPortCount Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The number of physical ports on this controller. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.20 |
Controllers[{item}].ControllerCapabilities.VirtualizationOffload Controllers[{item}].ControllerCapabilities.VirtualizationOffload.SRIOV Controllers[{item}].ControllerCapabilities.VirtualizationOffload.SRIOV.SRIOVVEPACapable Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The value of this property shall be a boolean indicating whether this controller supports Single Root Input/Output Virtualization (SR-IOV) in Virtual Ethernet Port Aggregator (VEPA) mode. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Controllers[{item}].ControllerCapabilities.VirtualizationOffload.VirtualFunction Controllers[{item}].ControllerCapabilities.VirtualizationOffload.VirtualFunction.DeviceMaxCount Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The maximum number of Virtual Functions (VFs) supported by this controller. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.20 |
Controllers[{item}].ControllerCapabilities.VirtualizationOffload.VirtualFunction.MinAssignmentGroupSize Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The minimum number of Virtual Functions (VFs) that can be allocated or moved between physical functions for this controller. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.20 |
Controllers[{item}].ControllerCapabilities.VirtualizationOffload.VirtualFunction.NetworkPortMaxCount Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The maximum number of Virtual Functions (VFs) supported per network port for this controller. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.20 |
Controllers[{item}].FirmwarePackageVersion Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The version number of the user-facing firmware package. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Controllers[{item}].Links
Controllers[{item}].Links.NetworkDeviceFunctions (array)
Member of NetworkAdapter.v1_3_0.NetworkAdapter
NetworkDeviceFunctions
is an array containing elements of:
NetworkDeviceFunctions[{item}].@odata.id Member of NetworkAdapter.v1_3_0.NetworkAdapter
Type | string |
Read Only | True |
Format | uri-reference |
Controllers[{item}].Links.NetworkPorts (array)
Member of NetworkAdapter.v1_3_0.NetworkAdapter
NetworkPorts
is an array containing elements of:
NetworkPorts[{item}].@odata.id Member of NetworkAdapter.v1_3_0.NetworkAdapter
Type | string |
Read Only | True |
Format | uri-reference |
Controllers[{item}].Location Controllers[{item}].Location.PartLocation Controllers[{item}].Location.PartLocation.LocationOrdinalValue Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The number that represents the location of the part. If LocationType is slot and this unit is in slot 2, the LocationOrdinalValue is 2. |
Type | integer or null |
Read Only | True |
Controllers[{item}].Location.PartLocation.LocationType Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The location types for PartLocation. |
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Slot |
The slot as the type of location. |
Bay |
The bay as the type of location. |
Connector |
The connector as the type of location. |
Socket |
The socket as the type of location. |
Controllers[{item}].Location.PartLocation.Orientation Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The orientation for the ordering of the part location ordinal value. |
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
FrontToBack |
The ordering for LocationOrdinalValue is front to back. |
BackToFront |
The ordering for the LocationOrdinalValue is back to front. |
TopToBottom |
The ordering for the LocationOrdinalValue is top to bottom. |
BottomToTop |
The ordering for LocationOrdinalValue is bottom to top. |
LeftToRight |
The ordering for the LocationOrdinalValue is left to right. |
RightToLeft |
The ordering for the LocationOrdinalValue is right to left. |
Controllers[{item}].Location.PartLocation.Reference Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The reference area for the location of the part. |
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Top |
The part is in the top of the unit. |
Bottom |
The part is in the bottom of the unit. |
Front |
The part is in the front of the unit. |
Rear |
The part is in the rear of the unit. |
Left |
The part is on the left side of of the unit. |
Right |
The part is on the right side of the unit. |
Middle |
The part is in the middle of the unit. |
Controllers[{item}].Location.PartLocation.ServiceLabel Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The label of the part location, such as a silk-screened name or a printed label. |
Type | string or null |
Read Only | True |
Controllers[{item}].Location.Placement Controllers[{item}].Location.Placement.AdditionalInfo Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | Area designation or other additional info. |
Type | string or null |
Read Only | False |
Controllers[{item}].Location.Placement.Rack Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The name of a rack location within a row. |
Type | string or null |
Read Only | False |
Controllers[{item}].Location.Placement.RackOffset Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The vertical location of the item, in terms of RackOffsetUnits. |
Type | integer or null |
Read Only | False |
Controllers[{item}].Location.Placement.RackOffsetUnits Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The type of rack unit in use. |
Type | string or null |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OpenU |
A rack unit that is equal to 48 mm (1.89 in). |
EIA_310 |
A rack unit that is equal to 1.75 in (44.45 mm). |
Controllers[{item}].Location.Placement.Row Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The name of the row. |
Type | string or null |
Read Only | False |
Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The manufacturer or OEM of this network adapter. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The model string used by the manufacturer to reference this network adapter. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Member of NetworkAdapter.v1_3_0.NetworkAdapter
NetworkDeviceFunctions
is an array containing elements of:
NetworkDeviceFunctions[{item}].@odata.id Member of NetworkAdapter.v1_3_0.NetworkAdapter
Type | string |
Read Only | True |
Format | uri-reference |
Member of NetworkAdapter.v1_3_0.NetworkAdapter
NetworkPorts
is an array containing elements of:
NetworkPorts[{item}].@odata.id Member of NetworkAdapter.v1_3_0.NetworkAdapter
Type | string |
Read Only | True |
Format | uri-reference |
Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | Option ROM Systems Management Architecture for Server Hardware (SMASH) Command Line Protocol (CLP) support version. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Member of NetworkAdapter.v1_3_0.NetworkAdapter
Controllers
is an array containing elements of:
Controllers[{item}].ConfigurationStatus
Controllers[{item}].ConfigurationStatus.Detail (array)
Member of NetworkAdapter.v1_3_0.NetworkAdapter
Detail
is an array containing elements of:
Detail[{item}].Group Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | Configuration group identifier. |
Type | integer or null |
Read Only | True |
Detail[{item}].SubGroup Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | Configuration sub-group identifier. |
Type | integer or null |
Read Only | True |
Detail[{item}].Summary Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | A digest value representing the current state of configuration for this group/sub-group. |
Type | integer or null |
Read Only | True |
Controllers[{item}].ConfigurationStatus.Summary Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | A digest value representing the current configuration state of this network adapter controller. |
Type | integer or null |
Read Only | True |
Controllers[{item}].DeviceLimitationsBitmap Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | Indicates any unique device limitations. A value of 0 indicates no limitations are present. When set, bit 0 indicates that the device cannot validate data received when in standby power. All other bit mappings are reserved. |
Type | integer or null |
Read Only | True |
Controllers[{item}].EdgeVirtualBridging Controllers[{item}].EdgeVirtualBridging.ChannelDescriptionTLVCapable Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | When true, this controller supports HPE Flex10Qbg Channel Description TLVs. |
Type | boolean or null |
Read Only | True |
Controllers[{item}].EdgeVirtualBridging.ChannelLinkControlTLVCapable Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | When true, this controller supports HPE Flex10Qbg Channel Link Control TLVs. |
Type | boolean or null |
Read Only | True |
Controllers[{item}].EmbeddedLLDPFunctions Controllers[{item}].EmbeddedLLDPFunctions.Enabled Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | NOTE: This is a read-only property when the adapter is installed on an HPE Synergy server. When false, globally disables device functions on this controller which utilize HPE defined embedded LLDP. When set false will also disable EVB, FCoE, RoCE, and DCBX capabilities on this controller. This property does not affect Ethernet NPAR functionality. |
Type | boolean or null |
Read Only | False |
Controllers[{item}].EmbeddedLLDPFunctions.Optional Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | When true, indicates that this controller has the ability to globally disable all network device functions which utilize HPE defined embedded LLDP. |
Type | boolean or null |
Read Only | True |
Controllers[{item}].FactoryDefaultsCurrentlyActive Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | When true, this controller's configuration matches factory default settings. |
Type | boolean or null |
Read Only | True |
Controllers[{item}].FunctionTypeLimits (array)
Member of NetworkAdapter.v1_3_0.NetworkAdapter
FunctionTypeLimits
is an array containing elements of:
FunctionTypeLimits[{item}].ConstraintDescription Member of NetworkAdapter.v1_3_0.NetworkAdapter
Type | string or null |
Read Only | True |
FunctionTypeLimits[{item}].EthernetResourcesConsumed Member of NetworkAdapter.v1_3_0.NetworkAdapter
Type | integer or null |
Read Only | True |
FunctionTypeLimits[{item}].FCoEResourcesConsumed Member of NetworkAdapter.v1_3_0.NetworkAdapter
Type | integer or null |
Read Only | True |
FunctionTypeLimits[{item}].RDMAResourcesConsumed Member of NetworkAdapter.v1_3_0.NetworkAdapter
Type | integer or null |
Read Only | True |
FunctionTypeLimits[{item}].TotalSharedResourcesAvailable Member of NetworkAdapter.v1_3_0.NetworkAdapter
Type | integer or null |
Read Only | True |
FunctionTypeLimits[{item}].iSCSIResourcesConsumed Member of NetworkAdapter.v1_3_0.NetworkAdapter
Type | integer or null |
Read Only | True |
Controllers[{item}].FunctionTypes (array)
Member of NetworkAdapter.v1_3_0.NetworkAdapter
FunctionTypes
is an array containing elements of:
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Ethernet |
Has Ethernet functionality. |
FibreChannel |
Has native FibreChannel functionality. |
iSCSI |
Has iSCSI functionality. |
FCoE |
Has FibreChannel over Ethernet functionality. |
InfiniBand |
Has InfiniBand functionality. |
RoCE |
Has RDMA over Converged Ethernet protocol functionality. |
iWarp |
Has internet Wide-area RDMA protocol functionality. |
Controllers[{item}].MostRecentConfigurationChangeSource Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | Type of the last client to have changed configuration on this device. |
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
None |
No change detected. |
OS |
Operating System Driver |
VendorControl |
Vendor Control Software |
VirtualConnect |
Virtual Connect |
CNU |
Converged Network Utility |
Other |
Other configuration or diagnostic software. |
Redfish |
Redfish Client |
UEFI-HII |
UEFI Human Interface Infrastructure |
Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | Indicates the implementation timing of a reset to factory default settings request, when made with the server in the standby power state. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Immediate |
Defaults take effect within 2 seconds of being applied. |
AtFullPower |
Defaults take effect within 5 seconds of power being applied. |
AtNextReboot |
Defaults take effect on next reboot to full power. |
Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | Printed Circuit Assembly number for the circuit board comprising this device. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | Controls Redfish configuration write access to network adapters. When present and disabled, network adapter information is read-only. Note that some HPE advanced network adapters will present a reduced level of capability when disabled. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Enabled |
The Redfish management interface is enabled to make changes on this network adapter. To return to the Disabled state, a network adapter reset to factory default operation is required. |
Disabled |
The network adapter is operating in read-only mode relative to the Redfish management interface. To transition to this state, a network adapter reset to factory default operation is required. |
Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | Manufacturer's Part number for this network adapter. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The value of this property shall contain the Stock Keeping Unit (SKU) for the network adapter. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | The serial number for this network adapter. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Settings.href Member of NetworkAdapter.v1_3_0.NetworkAdapter
Description | Reference to the resource the client may PUT/PATCH to in order to change this resource. |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
Member of NetworkAdapter.v1_3_0.NetworkAdapter See the Redfish standard schema and specification for information on common Status object.
NetworkAdapter.ResetSettingsToDefault Member of NetworkAdapter.v1_3_0.NetworkAdapter There are no parameters for this action.
NetworkAdapter.FlushConfigurationToNVM Member of NetworkAdapter.v1_3_0.NetworkAdapter There are no parameters for this action.
@odata.type: "#NetworkAdapterCollection.NetworkAdapterCollection"
A Collection of NetworkAdapter resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/networkadapters |
GET |
Link Name | Destination type |
---|---|
Members[] |
NetworkAdapter |
Member of NetworkAdapterCollection.NetworkAdapterCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of NetworkAdapterCollection.NetworkAdapterCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of NetworkAdapterCollection.NetworkAdapterCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Member of NetworkAdapterCollection.NetworkAdapterCollection
Description | Provides the discovery status of this collection. For some server platforms, only partial device discovery is possible under auxiliary power. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
AllDevices |
The server state allows complete device discovery. All installed devices are listed as members. |
AuxPowerDevices |
The server architecture may not support power to all installed devices in the current auxiliary power state. Only devices capable of operating in this power state are listed as members. Additional devices may be listed when the server is fully powered. |
@odata.type: "#NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction"
A Network Device Function represents a logical interface exposed by the network adapter.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/networkadapters/{item}/networkdevicefunctions/{item} |
GET |
/redfish/v1/chassis/{item}/networkadapters/{item}/networkdevicefunctions/{item}/Settings |
GET POST PATCH |
/redfish/v1/systems/{item}/networkinterfaces/{item}/networkdevicefunctions/{item} |
GET |
Link Name | Destination type |
---|---|
@Redfish.Settings/SettingsObject |
NetworkDeviceFunction |
Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
AssignablePhysicalPorts
is an array containing elements of:
Type | string |
Read Only | True |
Format | uri-reference |
Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | Network device boot mode configuration values. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Disabled |
Do not indicate to UEFI/BIOS that this device is bootable. |
PXE |
Boot this device using the embedded PXE support. Only applicable if the NetworkDeviceFunctionType is set to Ethernet. Not supported by HPE. |
iSCSI |
Boot this device using the embedded iSCSI boot support and configuration. Only applicable if the NetworkDeviceFunctionType is set to iSCSI. |
FibreChannel |
Boot this device using the embedded Fibre Channel support and configuration. Only applicable if the NetworkDeviceFunctionType is set to FibreChannel. |
FibreChannelOverEthernet |
Boot this device using the embedded Fibre Channel over Ethernet (FCoE) boot support and configuration. Only applicable if the NetworkDeviceFunctionType is set to FibreChannelOverEthernet. |
Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | A boolean indicating whether the network device function is enabled. Disabled network device functions shall not be enumerated or seen by the operating system. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.20 |
Ethernet.MACAddress Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The effective current MAC Address of this network device function. If an assignable MAC address is not supported, this is a read only alias of the PermanentMACAddress. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
Ethernet.MTUSize Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The Maximum Transmission Unit (MTU) configured for this Network Device Function. This value serves as a default for the OS driver when booting. The value only takes-effect on boot. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.20 |
Ethernet.PermanentMACAddress Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The Permanent MAC Address of this network device function (physical function). This value is typically programmed during the manufacturing time. This address is not assignable. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
FibreChannel.AllowFIPVLANDiscovery Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | For FCoE connections, a boolean indicating whether the FIP VLAN Discovery Protocol is used to determine the FCoE VLAN ID selected by the network device function for the FCoE connection. If true, and the FIP VLAN Discovery succeeds, the FCoEActiveVLANId property shall reflect the FCoE VLAN ID to be used for all FCoE traffic. If false, or if the FIP VLAN Discovery protocol fails, the FCoELocalVLANId shall be used for all FCoE traffic and the FCoEActiveVLANId shall reflect the FCoELocalVLANId. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.20 |
FibreChannel.BootTargets (array)
Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
BootTargets
is an array containing elements of:
BootTargets[{item}].BootPriority Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The relative priority for this entry in the boot targets array. Lower numbers shall represent higher priority, with zero being the highest priority. The BootPriority shall be unique for all entries of the BootTargets array. |
Type | integer or null |
Read Only | False |
BootTargets[{item}].LUNID Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The Logical Unit Number (LUN) ID to boot from on the device referred to by the corresponding WWPN. |
Type | string or null |
Read Only | False |
BootTargets[{item}].WWPN Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The value of this property shall be World-Wide Port Name (WWPN) to boot from. |
Type | string or null |
Read Only | False |
FibreChannel.FCoEActiveVLANId Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | For FCoE connections, the value of this property shall be null or a VLAN ID currently being used for FCoE traffic. When the FCoE link is down this value shall be null. When the FCoE link is up this value shall be either the FCoELocalVLANId property or a VLAN discovered via the FIP protocol. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
FibreChannel.FCoELocalVLANId Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | For FCoE connections, the locally configured VLAN ID. This value shall be used for FCoE traffic to this network device function during boot unless AllowFIPVLANDiscovery is true and a valid FCoE VLAN ID is found via the FIP VLAN Discovery Protocol. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.20 |
FibreChannel.PermanentWWNN Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The permanent World-Wide Node Name (WWNN) of this network device function (physical function). This value is typically programmed during the manufacturing time. This address is not assignable. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
FibreChannel.PermanentWWPN Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
FibreChannel.WWNN Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The value of this property shall be the effective current World-Wide Node Name (WWNN) of this network device function (physical function). If an assignable WWNN is not supported, this is a read only alias of the PermanentWWNN. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
FibreChannel.WWNSource Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The configuration source of the WWNs for this connection (WWPN and WWNN). |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
ConfiguredLocally |
The set of FC/FCoE boot targets was applied locally through API or UI. |
ProvidedByFabric |
The set of FC/FCoE boot targets was applied by the Fibre Channel fabric. |
FibreChannel.WWPN Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The effective current World-Wide Port Name (WWPN) of this network device function (physical function). If an assignable WWPN is not supported, this is a read only alias of the PermanentWWPN. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The number of virtual functions (VFs) availbale for this network device function. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
NetDevFuncCapabilities
is an array containing elements of:
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Disabled |
Neither enumerated nor visible to the operating system. |
Ethernet |
Appears to the operating system as an Ethernet device. |
FibreChannel |
Appears to the operating system as a Fibre Channel device. |
iSCSI |
Appears to the operating system as an iSCSI device. |
FibreChannelOverEthernet |
Appears to the operating system as an FCoE device. |
Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The configured capability of this network device function. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Disabled |
Neither enumerated nor visible to the operating system. |
Ethernet |
Appears to the operating system as an Ethernet device. |
FibreChannel |
Appears to the operating system as a Fibre Channel device. |
iSCSI |
Appears to the operating system as an iSCSI device. |
FibreChannelOverEthernet |
Appears to the operating system as an FCoE device. |
Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | Controls the source of boot target parameters for this network device function. This property can only be configured when the network device function is not in the Disabled state. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.30 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
UEFI |
Boot target parameters are under control of UEFI and the device option ROM. Any target parameters configured on this network device function are ignored. |
NetworkDeviceFunction |
Boot target parameters as configured on this network device function will be used. |
None |
Boot mode is configured disabled, and no target source applies. |
Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The Connection ID to be used with EVB, in IETF RFC-4122 UUID format. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
NetDevFuncCapabilities
is an array containing elements of:
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Disabled |
Neither enumerated nor visible to the operating system. |
Ethernet |
Appears to the operating system as an Ethernet device. |
FibreChannel |
Appears to the operating system as a Fibre Channel device. |
iSCSI |
Appears to the operating system as an iSCSI device. |
FCoE |
Appears to the operating system as an FCoE device. |
InfiniBand |
Appears to the operating system as an InfiniBand device. |
RoCE |
(Deprecated function type for some adapters, in iLO 1.40+) Appears to the operating system as an RDMA over converged Ethernet device. |
iWarp |
(Deprecated function type for some adapters, in iLO 1.40+) Appears to the operating system as an iWarp RDMA device. |
Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The presently configured interconnection capability of this network device function. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Disabled |
This function is disabled, and is neither enumerated nor visible to the operating system. |
Ethernet |
This function is configured to operate as an Ethernet device. |
FibreChannel |
This function is configured to operate as a Fibre Channel device. |
iSCSI |
This function is configured to operate as an iSCSI device. |
FCoE |
This function is configured to oeprate as an FCoE device. |
InfiniBand |
|
RCoE |
|
iWarp |
(Deprecated function type for some adapters, in iLO 1.40+) This function is configured to operate as an iWarp RDMA device. |
Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The number of Fibre Channel boot targets supported by this network device function. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | Current status of the EVB Virtual Link (S-Channel) supporting this function. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
NoChannel |
Port link is down, or the connected switch has not assigned an SVID. |
SwitchChannelDown |
SVID is assigned but Virtual Link status is down. |
HostDriverDown |
SVID is assigned and Virtual Link status is up, but the host OS driver is inactive. |
VirtualLinkUp |
SVID is assigned, Virual Link status is up, and the host OS driver is active. |
Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | Enables Ethernet Wake On LAN (WoL) capability for this function when true. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.20 |
A reference to the physical port currently assigned to this network device function.
PhysicalPortAssignment is a link ("@odata.id": URI
) to another resource.
Settings.href Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | Reference to the resource the client may PUT/PATCH to in order to change this resource. |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction See the Redfish standard schema and specification for information on common Status object.
Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | Indicates whether Single Root I/O Virtualization (SR-IOV) Virual Functions (VFs) are enabled for this network device function. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
iSCSIBoot.AuthenticationMethod Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | iSCSI Boot authentication method configuration values. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
None |
No iSCSI authentication is used. |
CHAP |
iSCSI Challenge Handshake Authentication Protocol (CHAP) authentication is used. |
MutualCHAP |
iSCSI Mutual Challenge Handshake Authentication Protocol (CHAP) authentication is used. |
iSCSIBoot.CHAPSecret Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The shared secret for CHAP authentication. Must be 0, 12, or 16 characters in length. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.CHAPUsername Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The username for CHAP authentication. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.IPAddressType Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The type of IP address (IPv6 or IPv4) being populated in the iSCSIBoot IP address fields. Mixing of IPv6 and IPv4 addresses on the same network device function is not allowed. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
IPv4 |
IPv4 addressing is used for all IP-fields in this object. |
IPv6 |
IPv6 addressing is used for all IP-fields in this object. |
iSCSIBoot.IPMaskDNSViaDHCP Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | When true, the iSCSI boot initiator will use DHCP to obtain the iniator name, IP address, and netmask. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.InitiatorDefaultGateway Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The IPv6 or IPv4 iSCSI boot default gateway. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.InitiatorIPAddress Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The IPv6 or IPv4 address of the iSCSI boot initiator. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.InitiatorName Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The iSCSI initiator name. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.InitiatorNetmask Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The IPv6 or IPv4 netmask of the iSCSI boot initiator. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.MutualCHAPSecret Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The CHAP secret for 2-way CHAP authentication. Must be 0, 12, or 16 characters in length. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.MutualCHAPUsername Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The CHAP username for 2-way CHAP authentication. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.PrimaryDNS Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The IPv6 or IPv4 address of the primary DNS server for the iSCSI boot initiator. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.PrimaryLUN Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The logical unit number (LUN) for the primary iSCSI boot target. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.PrimaryTargetIPAddress Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The IP address (IPv6 or IPv4) for the primary iSCSI boot target. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.PrimaryTargetName Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The name of the primary iSCSI boot target, iSCSI Qualified Name (IQN). |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.PrimaryTargetTCPPort Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The TCP port for the primary iSCSI boot target. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.PrimaryVLANEnable Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | This indicates if the primary VLAN is enabled. Not supported by HPE. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.PrimaryVLANId Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The 802.1q VLAN ID to use for iSCSI boot for both the primary and secondary targets. Assign null value to disable. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.RouterAdvertisementEnabled Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | A boolean indicating whether IPv6 router advertisement is enabled for the iSCSI boot target. This setting shall only apply to IPv6 configurations. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.SecondaryDNS Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The value of this property shall be the IPv6 or IPv4 address of the secondary DNS server for the iSCSI boot initiator. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.SecondaryLUN Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The logical unit number (LUN) for the secondary iSCSI boot target. Not supported by HPE. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.SecondaryTargetIPAddress Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The IP address (IPv6 or IPv4) for the secondary iSCSI boot target. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.SecondaryTargetName Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The name of the iSCSI secondary boot target, iSCSI Qualified Name (IQN). Not supported by HPE. The value from PrimaryTargetName will be used for the secondary iSCSI boot target if configured. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.SecondaryTargetTCPPort Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The TCP port for the secondary iSCSI boot target. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.SecondaryVLANEnable Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | This indicates if the secondary VLAN is enabled. Not supported by HPE. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.SecondaryVLANId Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | The 802.1q VLAN ID to use for iSCSI boot from the secondary target. Not supported by HPE. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.20 |
iSCSIBoot.TargetInfoViaDHCP Member of NetworkDeviceFunction.v1_3_0.NetworkDeviceFunction
Description | When true indicates the iSCSI boot target name, LUN, IP address, and netmask should be obtained from DHCP. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.20 |
@odata.type: "#NetworkDeviceFunctionCollection.NetworkDeviceFunctionCollection"
A Collection of NetworkDeviceFunction resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/networkadapters/{item}/networkdevicefunctions |
GET |
/redfish/v1/systems/{item}/networkinterfaces/{item}/networkdevicefunctions |
GET |
Link Name | Destination type |
---|---|
Members[] |
NetworkDeviceFunction |
Member of NetworkDeviceFunctionCollection.NetworkDeviceFunctionCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of NetworkDeviceFunctionCollection.NetworkDeviceFunctionCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of NetworkDeviceFunctionCollection.NetworkDeviceFunctionCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#NetworkInterface.v1_1_1.NetworkInterface"
A NetworkInterface contains references linking NetworkAdapter, NetworkPort, and NetworkDeviceFunction resources and represents the functionality available to the containing system.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/networkinterfaces/{item} |
GET |
Link Name | Destination type |
---|---|
NetworkDeviceFunctions |
Collection of NetworkDeviceFunction |
link to collection of membertype NetworkDeviceFunction. The collection of device functions avaliable on this network interface.
NetworkDeviceFunctions is a link ("@odata.id": URI
) to another resource.
Link to a collection of membertype NetworkPort. The collection of ports avaliable on this network interface.
NetworkPorts is a link ("@odata.id": URI
) to another resource.
Member of NetworkInterface.v1_1_1.NetworkInterface See the Redfish standard schema and specification for information on common Status object.
@odata.type: "#NetworkInterfaceCollection.NetworkInterfaceCollection"
A Collection of NetworkInterface resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/networkinterfaces |
GET |
Link Name | Destination type |
---|---|
Members[] |
NetworkInterface |
Member of NetworkInterfaceCollection.NetworkInterfaceCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of NetworkInterfaceCollection.NetworkInterfaceCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of NetworkInterfaceCollection.NetworkInterfaceCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Member of NetworkInterfaceCollection.NetworkInterfaceCollection
Description | Provides the discovery status of this collection. For some server platforms, only partial device discovery is possible under auxiliary power. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
AllDevices |
The server state allows complete device discovery. All installed devices are listed as members. |
AuxPowerDevices |
The server is in the auxiliary power state and only devices capable of operating in this power state are listed as members. Additional devices may be listed when the server is fully powered. |
@odata.type: "#NetworkPort.v1_2_0.NetworkPort"
A Network Port represents a discrete physical port capable of connecting to a network.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/networkadapters/{item}/networkports/{item} |
GET |
/redfish/v1/chassis/{item}/networkadapters/{item}/networkports/{item}/settings |
GET POST PATCH |
/redfish/v1/systems/{item}/networkinterfaces/{item}/networkports/{item} |
GET |
/redfish/v1/systems/{item}/networkinterfaces/{item}/networkports/{item}/settings |
GET POST PATCH |
Link Name | Destination type |
---|---|
@Redfish.Settings/SettingsObject |
NetworkPort |
Member of NetworkPort.v1_2_0.NetworkPort
Description | Physical link technology values. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Ethernet |
The port is capable of connecting to an Ethernet network. |
InfiniBand |
The port is capable of connecting to an InfiniBand network. |
FibreChannel |
The port is capable of connecting to a Fibre Channel network. |
Member of NetworkPort.v1_2_0.NetworkPort
AssociatedNetworkAddresses
is an array containing elements of:
Type | string or null |
Read Only | True |
Member of NetworkPort.v1_2_0.NetworkPort
Description | Network Port Current Link Speed. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.40 |
Member of NetworkPort.v1_2_0.NetworkPort
Description | Indicates whether IEEE 802.3az Energy Efficient Ethernet (EEE) is enabled for this network port. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.20 |
Member of NetworkPort.v1_2_0.NetworkPort
Description | Ethernet flow control configuration values. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
None |
No IEEE 802.3x flow control is enabled on this port. |
TX |
IEEE 802.3x flow control may be initiated by this station. |
RX |
IEEE 802.3x flow control may be initiated by the link partner. |
TX_RX |
IEEE 802.3x flow control may be initiated by this station or the link partner. |
Member of NetworkPort.v1_2_0.NetworkPort
Description | Ethernet flow control configuration values. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
None |
No IEEE 802.3x flow control is enabled on this port. |
TX |
IEEE 802.3x flow control may be initiated by this station. |
RX |
IEEE 802.3x flow control may be initiated by the link partner. |
TX_RX |
IEEE 802.3x flow control may be initiated by this station or the link partner. |
Member of NetworkPort.v1_2_0.NetworkPort
Description | Physical link status values. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Down |
The port is enabled but link is down. |
Up |
The port is enabled and link is good (up). |
Member of NetworkPort.v1_2_0.NetworkPort
NetDevFuncMaxBWAlloc
is an array containing elements of:
NetDevFuncMaxBWAlloc[{item}].MaxBWAllocPercent Member of NetworkPort.v1_2_0.NetworkPort
Description | The maximum bandwidth allocation percentage allocated to the associated network device function. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.20 |
NetDevFuncMaxBWAlloc[{item}].NetworkDeviceFunction
A reference to the associated network device function that this maximum bandwidth percentage allocation applies to.
NetworkDeviceFunction is a link ("@odata.id": URI
) to another resource.
Member of NetworkPort.v1_2_0.NetworkPort
NetDevFuncMinBWAlloc
is an array containing elements of:
NetDevFuncMinBWAlloc[{item}].MinBWAllocPercent Member of NetworkPort.v1_2_0.NetworkPort
Description | The minimum bandwidth allocation percentage allocated to the associated network device function instance. The sum total of all minimum percentages shall not exceed 100. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.20 |
NetDevFuncMinBWAlloc[{item}].NetworkDeviceFunction
A reference to the associated network device function that this minimum bandwidth percentage allocation applies to.
NetworkDeviceFunction is a link ("@odata.id": URI
) to another resource.
Member of NetworkPort.v1_2_0.NetworkPort
Description | Indicates the ability of this network port to autonegotiate link speed. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Edge Virtual Bridging (EVB) information for this port.
Evb is a link ("@odata.id": URI
) to another resource.
Link-Layer Discovery Protocol (LLDP) information for this port.
Lldp is a link ("@odata.id": URI
) to another resource.
Member of NetworkPort.v1_2_0.NetworkPort
Description | When true, local loopback is active on this port. PortDiagnosticsEnabled must first be true in order to set this property to true. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.20 |
Member of NetworkPort.v1_2_0.NetworkPort
Description | When true, remote loopback is active on this port. PortDiagnosticsEnabled must first be true in order to set this property to true. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.20 |
Member of NetworkPort.v1_2_0.NetworkPort
Description | When true, the port has local loopback capability. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Member of NetworkPort.v1_2_0.NetworkPort
Description | When true, the port has remote loopback capability. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Member of NetworkPort.v1_2_0.NetworkPort
Description | When true, diagnostic features are enabled on this port. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.20 |
Member of NetworkPort.v1_2_0.NetworkPort
VirtualFunctionAllocations
is an array containing elements of:
VirtualFunctionAllocations[{item}].NetworkDeviceFunction
The logical network device function to which this virtual function allocation applies.
NetworkDeviceFunction is a link ("@odata.id": URI
) to another resource.
VirtualFunctionAllocations[{item}].VirtualFunctionsAllocated Member of NetworkPort.v1_2_0.NetworkPort
Description | The number of virtual functions allocated to this logical network device function instance. |
Type | number or null |
Read Only | False |
Member of NetworkPort.v1_2_0.NetworkPort
Description | The physical port number on the network adapter hardware that this Network Port corresponds to. This value should match a value visible on the hardware. When HostPortEnabled and ManagementPortEnabled are both "false", the port shall not establish physical link. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
Member of NetworkPort.v1_2_0.NetworkPort
Description | The largest maximum transmission unit (MTU) that can be configured for this network port. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.20 |
Settings.href Member of NetworkPort.v1_2_0.NetworkPort
Description | Reference to the resource the client may PUT/PATCH to in order to change this resource. |
Type | string |
Read Only | True |
Added | iLO 5 1.20 |
Member of NetworkPort.v1_2_0.NetworkPort
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.20 |
Member of NetworkPort.v1_2_0.NetworkPort See the Redfish standard schema and specification for information on common Status object.
Member of NetworkPort.v1_2_0.NetworkPort
SupportedEthernetCapabilities
is an array containing elements of:
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
WakeOnLAN |
Wake on LAN (WoL) is supported on this port. |
EEE |
IEEE 802.3az Energy Efficient Ethernet (EEE) is supported on this port. |
Member of NetworkPort.v1_2_0.NetworkPort
SupportedLinkCapabilities
is an array containing elements of:
SupportedLinkCapabilities[{item}].CapableLinkSpeedMbps (array)
Member of NetworkPort.v1_2_0.NetworkPort
CapableLinkSpeedMbps
is an array containing elements of:
Type | integer or null |
Read Only | True |
SupportedLinkCapabilities[{item}].LinkNetworkTechnology Member of NetworkPort.v1_2_0.NetworkPort
Description | Physical link technology values. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.20 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Ethernet |
The port is capable of connecting to an Ethernet network. |
InfiniBand |
The port is capable of connecting to an InfiniBand network. |
FibreChannel |
The port is capable of connecting to a Fibre Channel network. |
SupportedLinkCapabilities[{item}].LinkSpeedMbps Member of NetworkPort.v1_2_0.NetworkPort
Description | The speed of the link in Mbps when this link network technology is active. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.20 |
Member of NetworkPort.v1_2_0.NetworkPort
Description | Indicates whether Wake on LAN (WoL) is enabled for this network port. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.20 |
NetworkPort.DiagnosticsReset Member of NetworkPort.v1_2_0.NetworkPort There are no parameters for this action.
@odata.type: "#NetworkPortCollection.NetworkPortCollection"
A Collection of NetworkPort resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/networkadapters/{item}/networkports |
GET |
/redfish/v1/systems/{item}/networkinterfaces/{item}/networkports |
GET |
Link Name | Destination type |
---|---|
Members[] |
NetworkPort |
Member of NetworkPortCollection.NetworkPortCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of NetworkPortCollection.NetworkPortCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of NetworkPortCollection.NetworkPortCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#Power.v1_3_0.Power"
The Power resource describes the Power Metrics. It represents the properties for Power Consumption and Power Limiting.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/power |
GET PATCH |
Link Name | Destination type |
---|---|
Oem/Hpe/Links/FederatedGroupCapping |
HpeiLOFederatedGroupCapping |
Oem/Hpe/Links/PowerMeter |
HpePowerMeter |
Redundancy[]/RedundancySet[] |
Power |
Oem/Hpe/Links/FastPowerMeter |
HpePowerMeter |
Member of Power.v1_3_0.Power
BatteryBackedUnits
is an array containing elements of:
BatteryBackedUnits[{item}].BBUStatus BatteryBackedUnits[{item}].BBUStatus.Health Member of Power.v1_3_0.Power
Description | This represents the health state of this resource in the absence of its dependent resources. |
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OK |
Normal |
Warning |
A condition exists that requires attention |
Critical |
A critical condition exists that requires immediate attention |
BatteryBackedUnits[{item}].BBUStatus.HealthRollup Member of Power.v1_3_0.Power
Description | This represents the overall health state from the view of this resource. |
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OK |
Normal |
Warning |
A condition exists that requires attention |
Critical |
A critical condition exists that requires immediate attention |
BatteryBackedUnits[{item}].BBUStatus.State Member of Power.v1_3_0.Power
Description | This indicates the known state of the resource, such as if it is enabled. |
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Enabled |
This function or resource has been enabled. |
Disabled |
This function or resource has been disabled. |
StandbyOffline |
This function or resource is enabled, but awaiting an external action to activate it. |
StandbySpare |
This function or resource is part of a redundancy set and is awaiting a failover or other external action to activate it. |
InTest |
This function or resource is undergoing testing. |
Starting |
This function or resource is starting. |
Absent |
This function or resource is not present or not detected. |
UnavailableOffline |
This function or resource is present but cannot be used. |
Deferring |
The element will not process any commands but will queue new requests. |
Quiesced |
The element is enabled but only processes a restricted set of commands. |
Updating |
The element is updating and may be unavailable or degraded. |
BatteryBackedUnits[{item}].BayNumber Member of Power.v1_3_0.Power
Description | Bay number of the battery backed unit. |
Type | integer |
Read Only | True |
BatteryBackedUnits[{item}].CapacityWatts Member of Power.v1_3_0.Power
Description | Total capacity (in Watts) of the battery backed unit. |
Type | integer |
Read Only | True |
BatteryBackedUnits[{item}].CutOffSetPointmAh Member of Power.v1_3_0.Power
Description | Cut off threshold (mAh) where battery backed unit stops supplying power to the server. |
Type | integer |
Read Only | True |
BatteryBackedUnits[{item}].FirmwareVersion Member of Power.v1_3_0.Power
Description | Firmware version of the battery backed unit. |
Type | string |
Read Only | True |
BatteryBackedUnits[{item}].PercentCharge Member of Power.v1_3_0.Power
Description | Percentage charge remaining for the battery backed unit. |
Type | integer |
Read Only | True |
BatteryBackedUnits[{item}].RemainingCapacitymAh Member of Power.v1_3_0.Power
Description | Remaining capacity (mAh) of the battery backed unit. |
Type | integer |
Read Only | True |
BatteryBackedUnits[{item}].SerialNumber Member of Power.v1_3_0.Power
Description | Serial number of the battery backed unit. |
Type | string |
Read Only | True |
BatteryBackedUnits[{item}].TimeToCutOffSeconds Member of Power.v1_3_0.Power
Description | Run time (in seconds) available with the battery backed unit until cut off. This is detected only when battery is charging or discharging, otherwise set to 0. |
Type | integer |
Read Only | True |
BatteryBackedUnits[{item}].TimeToFullChargeMinutes Member of Power.v1_3_0.Power
Description | Time required (in minutes) to fully charge the battery backed unit. This is detected only when battery is charging or discharging, otherwise set to 0. |
Type | integer |
Read Only | True |
BatteryBackedUnits[{item}].UsableCapacitymAh Member of Power.v1_3_0.Power
Description | Usable capacity (mAh) of the battery backed unit. |
Type | integer |
Read Only | True |
Member of Power.v1_3_0.Power
Description | Battery Backup Unit Power Supply action determines what will occur when a server is running on battery power. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
DoNothing |
No action will be taken when a server switches to battery power. |
MomentaryPowerButtonPress |
Momentary virtual power button press which should shutdown host operating system when pressed. |
HostShutdown |
Shutdown message sent to host operating system with installed management software to initiate a shutdown. |
Member of Power.v1_3_0.Power
Description | When a brownout condition occurs in the server, this setting will determine if the server should recover from it. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.20 |
Member of Power.v1_3_0.Power
Description | Indicates if the system has CPU power metering. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.40 |
Member of Power.v1_3_0.Power
Description | Indicates if the system has DIMM power metering. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.40 |
Member of Power.v1_3_0.Power
Description | Indicates if the system has GPU power metering. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.40 |
Member of Power.v1_3_0.Power
Description | Indicates if the system has power metering. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of Power.v1_3_0.Power
Description | The redundant power supply mode that will be used when redundant power supplies are configured. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.15 |
The following are the supported values:
Value |
---|
Null |
Auto |
Balanced |
Even |
Odd |
Member of Power.v1_3_0.Power
Description | Minimum Safely Achievable Cap is the lowest cap value that is safe for a group power manager to apply to a particular server. It can either be identical to or slightly greater than the 0 percent cap value calculated during ROM power burn. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Power.v1_3_0.Power
Description | Indicates if the msac is valid. msac is valid only if this is true. |
Type | boolean |
Read Only | True |
Oem.Hpe.SNMPPowerThresholdAlert.DurationInMin Member of Power.v1_3_0.Power
Description | Sets the length of time, in minutes, that power consumption must remain above the warning threshold before an SNMP alert is triggered. The maximum duration is 240 minutes, and the duration must be a multiple of 5. |
Type | integer |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.SNMPPowerThresholdAlert.ThresholdWatts Member of Power.v1_3_0.Power
Description | Sets the power consumption threshold (watts). If power consumption exceeds this value for the specified time duration, an SNMP alert is triggered. |
Type | integer |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.SNMPPowerThresholdAlert.Trigger Member of Power.v1_3_0.Power
Description | Trigger determines whether alerts are based on peak power consumption, average power consumption, or if they are disabled. Trigger property can only be enabled if the ThresholdWatts and DurationInMin values are specified/configured. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Disabled |
AveragePowerConsumption |
PeakPowerConsumption |
Member of Power.v1_3_0.Power
PowerControl
is an array containing elements of:
PowerControl[{item}].@odata.id Member of Power.v1_3_0.Power
Type | string |
Read Only | True |
Format | uri-reference |
PowerControl[{item}].MemberId Member of Power.v1_3_0.Power
Description | This is the identifier for the member within the collection. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
PowerControl[{item}].PowerAllocatedWatts Member of Power.v1_3_0.Power
Description | The total amount of power that has been allocated (or budegeted)to chassis resources. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
PowerControl[{item}].PowerAvailableWatts Member of Power.v1_3_0.Power
Description | The amount of power not already budgeted and therefore available for additional allocation. (powerCapacity - powerAllocated). This indicates how much reserve power capacity is left. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
PowerControl[{item}].PowerCapacityWatts Member of Power.v1_3_0.Power
Description | The total amount of power available to the chassis for allocation. This may the power supply capacity, or power budget assigned to the chassis from an up-stream chassis. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
PowerControl[{item}].PowerConsumedWatts Member of Power.v1_3_0.Power
Description | The actual power being consumed by the chassis. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
PowerControl[{item}].PowerLimit PowerControl[{item}].PowerLimit.CorrectionInMs Member of Power.v1_3_0.Power
Description | The time required for the limiting process to reduce power consumption to below the limit. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
PowerControl[{item}].PowerLimit.LimitException Member of Power.v1_3_0.Power
Description | The action that is taken if the power cannot be maintained below the LimitInWatts. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
NoAction |
Take no action when the limit is exceeded. |
HardPowerOff |
Turn the power off immediately when the limit is exceeded. |
LogEventOnly |
Log an event when the limit is exceeded, but take no further action. |
Oem |
Take an OEM-defined action. |
PowerControl[{item}].PowerLimit.LimitInWatts Member of Power.v1_3_0.Power
Description | The Power limit in watts. Set to null to disable power capping. |
Type | number or null |
Read Only | False |
Added | iLO 5 1.10 |
PowerControl[{item}].PowerMetrics PowerControl[{item}].PowerMetrics.AverageConsumedWatts Member of Power.v1_3_0.Power
Description | The average power level over the measurement window (the last IntervalInMin minutes). |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
PowerControl[{item}].PowerMetrics.IntervalInMin Member of Power.v1_3_0.Power
Description | The time interval (or window) in which the PowerMetrics are measured over. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
PowerControl[{item}].PowerMetrics.MaxConsumedWatts Member of Power.v1_3_0.Power
Description | The highest power consumption level that has occured over the measurement window (the last IntervalInMin minutes). |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
PowerControl[{item}].PowerMetrics.MinConsumedWatts Member of Power.v1_3_0.Power
Description | The lowest power consumption level over the measurement window (the last IntervalInMin minutes). |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
PowerControl[{item}].PowerRequestedWatts Member of Power.v1_3_0.Power
Description | The potential power that the chassis resources are requesting which may be higher than the current level being consumed since requested power includes budget that the chassis resource wants for future use. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
PowerControl[{item}].RelatedItem (array)
Member of Power.v1_3_0.Power
RelatedItem
is an array containing elements of:
RelatedItem[{item}].@odata.id Member of Power.v1_3_0.Power
Type | string |
Read Only | True |
Format | uri-reference |
PowerControl[{item}].Status Member of Power.v1_3_0.Power See the Redfish standard schema and specification for information on common Status object.
Member of Power.v1_3_0.Power
PowerSupplies
is an array containing elements of:
PowerSupplies[{item}].@odata.id Member of Power.v1_3_0.Power
Type | string |
Read Only | True |
Format | uri-reference |
PowerSupplies[{item}].FirmwareVersion Member of Power.v1_3_0.Power
Description | The firmware version for this Power Supply |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
PowerSupplies[{item}].LastPowerOutputWatts Member of Power.v1_3_0.Power
Description | The average power output of this Power Supply |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
PowerSupplies[{item}].LineInputVoltage Member of Power.v1_3_0.Power
Description | The line input voltage at which the Power Supply is operating |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
PowerSupplies[{item}].LineInputVoltageType Member of Power.v1_3_0.Power
Description | The line voltage type supported as an input to this Power Supply |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Unknown |
The power supply line input voltage type cannot be determined. |
ACLowLine |
100-127V AC input. |
ACMidLine |
200-240V AC input. |
ACHighLine |
277V AC input. |
DCNeg48V |
-48V DC input. |
HighVoltageDC |
High Voltage DC input (380V). |
PowerSupplies[{item}].Manufacturer Member of Power.v1_3_0.Power
Description | This is the manufacturer of this power supply. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
PowerSupplies[{item}].MemberId Member of Power.v1_3_0.Power
Description | This is the identifier for the member within the collection. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
PowerSupplies[{item}].Model Member of Power.v1_3_0.Power
Description | The model number for this Power Supply |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
PowerSupplies[{item}].Oem.Hpe.AveragePowerOutputWatts Member of Power.v1_3_0.Power
Description | The latest observed average power being drawn by the power supply (Watts). This is usually updated every 10 seconds but the period can vary in some circumstances. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
PowerSupplies[{item}].Oem.Hpe.BayNumber Member of Power.v1_3_0.Power
Description | The power supply bay number. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
PowerSupplies[{item}].Oem.Hpe.HotplugCapable Member of Power.v1_3_0.Power
Description | If true, this power supply (and power supply bay) is capable of being hot-plugged. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
PowerSupplies[{item}].Oem.Hpe.MaxPowerOutputWatts Member of Power.v1_3_0.Power
Description | The latest observed maximum output power being drawn by the power supply (Watts). This is usually updated every 10 seconds but the period can vary in some circumstances. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
PowerSupplies[{item}].Oem.Hpe.Mismatched Member of Power.v1_3_0.Power
Description | If true, this power supply is mismatched with others in the system. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
PowerSupplies[{item}].Oem.Hpe.PowerSupplyStatus PowerSupplies[{item}].Oem.Hpe.PowerSupplyStatus.State Member of Power.v1_3_0.Power
Description | Indicates the known state of the resource. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Unknown |
Ok |
Degraded |
Failed |
OverVoltage |
OverCurrent |
OverTemperature |
ACPowerLost |
FanFailure |
WarningHighInputVoltage |
WarningLowInputVoltage |
WarningHighOutputVoltage |
WarningLowOutputVoltage |
WarningInletTemperature |
WarningInternalTemperature |
WarningHighAuxiliaryVoltage |
WarningLowAuxiliaryVoltage |
PowerSupplyMismatch |
GoodInStandby |
PowerSupplies[{item}].Oem.Hpe.iPDU PowerSupplies[{item}].Oem.Hpe.iPDU.IPAddress Member of Power.v1_3_0.Power
Description | The IP address of the iPDU connected to this power supply. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
PowerSupplies[{item}].Oem.Hpe.iPDU.MacAddress Member of Power.v1_3_0.Power
Description | The Ethernet MAC address of the iPDU connected to this power supply. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
PowerSupplies[{item}].Oem.Hpe.iPDU.Model Member of Power.v1_3_0.Power
Description | The model number of the iPDU connected to this power supply. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
PowerSupplies[{item}].Oem.Hpe.iPDU.SerialNumber Member of Power.v1_3_0.Power
Description | The serial number of the iPDU connected to this power supply. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
PowerSupplies[{item}].Oem.Hpe.iPDU.iPDUStatus PowerSupplies[{item}].Oem.Hpe.iPDU.iPDUStatus.State Member of Power.v1_3_0.Power
Description | Indicates the known state of the resource. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Unknown |
Ok |
Degraded |
Failed |
OverVoltage |
OverCurrent |
OverTemperature |
ACPowerLost |
FanFailure |
WarningHighInputVoltage |
WarningLowInputVoltage |
WarningHighOutputVoltage |
WarningLowOutputVoltage |
WarningInletTemperature |
WarningInternalTemperature |
WarningHighAuxiliaryVoltage |
WarningLowAuxiliaryVoltage |
PowerSupplyMismatch |
GoodInStandby |
PowerSupplies[{item}].Oem.Hpe.iPDUCapable Member of Power.v1_3_0.Power
Description | If true, this power supply is capable of being connected to an iPDUs. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
PowerSupplies[{item}].PartNumber Member of Power.v1_3_0.Power
Description | The part number for this Power Supply |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
PowerSupplies[{item}].PowerCapacityWatts Member of Power.v1_3_0.Power
Description | The maximum capacity of this Power Supply |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
PowerSupplies[{item}].PowerSupplyType Member of Power.v1_3_0.Power
Description | The Power Supply type (AC or DC) |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Unknown |
The power supply type cannot be determined |
AC |
Alternating Current (AC) power supply |
DC |
Direct Current (DC) power supply |
PowerSupplies[{item}].Redundancy Member of Power.v1_3_0.Power See the Redfish standard schema and specification for information on common Redundancy object.
PowerSupplies[{item}].RelatedItem (array)
Member of Power.v1_3_0.Power
RelatedItem
is an array containing elements of:
RelatedItem[{item}].@odata.id Member of Power.v1_3_0.Power
Type | string |
Read Only | True |
Format | uri-reference |
PowerSupplies[{item}].SerialNumber Member of Power.v1_3_0.Power
Description | The serial number for this Power Supply |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
PowerSupplies[{item}].SparePartNumber Member of Power.v1_3_0.Power
Description | The spare part number for this Power Supply |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
PowerSupplies[{item}].Status Member of Power.v1_3_0.Power See the Redfish standard schema and specification for information on common Status object.
Member of Power.v1_3_0.Power See the Redfish standard schema and specification for information on common Redundancy object.
Member of Power.v1_3_0.Power See the Redfish standard schema and specification for information on common Status object.
@odata.type: "#Processor.v1_0_0.Processor"
The Processor resource describes the Processor resource. It represents the properties of a processor attached to a System.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/processors/{item} |
GET |
Member of Processor.v1_0_0.Processor
Description | The instruction set of the processor |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
x86 |
x86 32-bit |
x86-64 |
x86 64-bit |
IA-64 |
Intel IA-64 |
ARM-A32 |
ARM 32-bit |
ARM-A64 |
ARM 64-bit |
MIPS32 |
MIPS 32-bit |
MIPS64 |
MIPS 64-bit |
OEM |
OEM-defined |
Member of Processor.v1_0_0.Processor
Description | The processor manufacturer |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Processor.v1_0_0.Processor
Description | The maximum clock speed of the processor |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Processor.v1_0_0.Processor
Description | The product model number of this device |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Processor.v1_0_0.Processor
Description | The processor asset tag. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Processor.v1_0_0.Processor
Cache
is an array containing elements of:
Cache[{item}].Associativity Member of Processor.v1_0_0.Processor
Description | The associativity of the cache. |
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
DirectMapped |
Direct Mapped |
2waySetAssociative |
2-way Set-Associative |
4waySetAssociative |
4-way Set-Associative |
FullyAssociative |
Fully Associative |
8waySetAssociative |
8-way Set-Associative |
16waySetAssociative |
16-way Set-Associative |
12waySetAssociative |
12-way Set-Associative |
24waySetAssociative |
24-way Set-Associative |
32waySetAssociative |
32-way Set-Associative |
48waySetAssociative |
48-way Set-Associative |
64waySetAssociative |
64-way Set-Associative |
20waySetAssociative |
20-way Set-Associative |
Cache[{item}].CacheSpeedns Member of Processor.v1_0_0.Processor
Description | The cache speed (ns). |
Type | integer or null |
Read Only | True |
Cache[{item}].CurrentSRAMType (array)
Member of Processor.v1_0_0.Processor
CurrentSRAMType
is an array containing elements of:
Description | The array of supported SRAM attributes currently used by the cache. |
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
NonBurst |
Non-Burst |
Burst |
Burst |
PipelineBurst |
Pipeline Burst |
Synchronous |
Synchronous |
Asynchronous |
Asynchronous |
Cache[{item}].EccType Member of Processor.v1_0_0.Processor
Description | The cache memory ECC type. |
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
None |
None |
Parity |
Parity |
SingleBitECC |
Single-bit ECC |
MultiBitECC |
Multi-bit ECC |
Cache[{item}].InstalledSizeKB Member of Processor.v1_0_0.Processor
Description | The installed cache size (KB). |
Type | integer or null |
Read Only | True |
Cache[{item}].Location Member of Processor.v1_0_0.Processor
Description | The cache location (internal or external). |
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Internal |
Internal |
External |
External |
Cache[{item}].MaximumSizeKB Member of Processor.v1_0_0.Processor
Description | The maximum cache size (KB). |
Type | integer or null |
Read Only | True |
Cache[{item}].Policy Member of Processor.v1_0_0.Processor
Description | The caching policy. |
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
WriteThrough |
Write through |
WriteBack |
Write back |
Varies |
Varies with memory address |
Cache[{item}].Socketed Member of Processor.v1_0_0.Processor
Description | If true, the cache is a socketed component. |
Type | boolean or null |
Read Only | True |
Cache[{item}].Status Member of Processor.v1_0_0.Processor See the Redfish standard schema and specification for information on common Status object.
Cache[{item}].SupportedSRAMType (array)
Member of Processor.v1_0_0.Processor
SupportedSRAMType
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
NonBurst |
Non-Burst |
Burst |
Burst |
PipelineBurst |
Pipeline Burst |
Synchronous |
Synchronous |
Asynchronous |
Asynchronous |
Cache[{item}].SystemCacheType Member of Processor.v1_0_0.Processor
Description | The cache type (unified, instructions, or data). |
Type | string or null |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Instruction |
Instruction |
Data |
Data |
Unified |
Unified |
Member of Processor.v1_0_0.Processor
Characteristics
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
64Bit |
64-bit Capable |
MultiCore |
Multi-Core |
HwThread |
Hardware Thread |
ExecuteProtection |
Execute Protection |
EnhancedVirtualization |
Enhanced Virtualization |
PowerPerfControl |
Power/Performance Control |
Oem.Hpe.ConfigStatus.Populated Member of Processor.v1_0_0.Processor
Description | True if the processor socket is populated with a CPU. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.ConfigStatus.State Member of Processor.v1_0_0.Processor
Description | The current state of the processor. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
CPU Enabled |
DisabledByUser |
CPU Disabled by User through BIOS Setup |
DisabledByBios |
CPU Disabled By BIOS (POST Error) |
Idle |
CPU is Idle, waiting to be enabled. |
Member of Processor.v1_0_0.Processor
Description | The number of enabled cores in the processor. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Processor.v1_0_0.Processor
Description | The processor external clock frequency (MHZ), for example, 1000 = 1 GHZ. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Processor.v1_0_0.Processor
MicrocodePatches
is an array containing elements of:
MicrocodePatches[{item}].CpuId Member of Processor.v1_0_0.Processor
Description | The microcode patch CPUID. |
Type | string |
Read Only | True |
MicrocodePatches[{item}].Date Member of Processor.v1_0_0.Processor
Description | The microcode patch date. |
Type | string |
Read Only | True |
Format | date-time |
MicrocodePatches[{item}].PatchId Member of Processor.v1_0_0.Processor
Description | The microcode patch ID. |
Type | string |
Read Only | True |
Member of Processor.v1_0_0.Processor
Description | The processor part number. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Processor.v1_0_0.Processor
Description | The speed of the processor (in MHz) as of the last system boot, for example, 1000 = 1GHz. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Processor.v1_0_0.Processor
Description | The processor serial number. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Processor.v1_0_0.Processor
Description | The processor voltage multiplied by 10, for example, 3.3v = 33. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Processor.v1_0_0.Processor
Description | The architecture of the processor |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
x86 |
x86 or x86-64 |
IA-64 |
Intel Itanium |
ARM |
ARM |
MIPS |
MIPS |
OEM |
OEM-defined |
ProcessorId.EffectiveFamily Member of Processor.v1_0_0.Processor
Description | The effective Family for this processor |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
ProcessorId.EffectiveModel Member of Processor.v1_0_0.Processor
Description | The effective Model for this processor |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
ProcessorId.IdentificationRegisters Member of Processor.v1_0_0.Processor
Description | The contents of the Identification Registers (CPUID) for this processor |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
ProcessorId.MicrocodeInfo Member of Processor.v1_0_0.Processor
Description | The Microcode Information for this processor |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
ProcessorId.Step Member of Processor.v1_0_0.Processor
Description | The Step value for this processor |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
ProcessorId.VendorId Member of Processor.v1_0_0.Processor
Description | The Vendor Identification for this processor |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Processor.v1_0_0.Processor
Description | The type of processor |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
CPU |
A Central Processing Unit |
GPU |
A Graphics Processing Unit |
FPGA |
A Field Programmable Gate Array |
DSP |
A Digital Signal Processor |
Accelerator |
An Accelerator |
OEM |
An OEM-defined Processing Unit |
Member of Processor.v1_0_0.Processor
Description | The socket or location of the processor |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Processor.v1_0_0.Processor See the Redfish standard schema and specification for information on common Status object.
Member of Processor.v1_0_0.Processor
Description | The total number of cores contained in this processor |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Processor.v1_0_0.Processor
Description | The total number of execution threads supported by this processor |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
@odata.type: "#ProcessorCollection.ProcessorCollection"
A Collection of Processor resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/processors |
GET |
Link Name | Destination type |
---|---|
Members[] |
Processor |
Member of ProcessorCollection.ProcessorCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of ProcessorCollection.ProcessorCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of ProcessorCollection.ProcessorCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#Role.v1_2_1.Role"
This resource defines a user role to be used in conjunction with a Manager Account.
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/roles/{item} |
GET |
Member of Role.v1_2_1.Role
AssignedPrivileges
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Login |
Able to log into the service and read resources. |
ConfigureManager |
Able to configure Manager resources. |
ConfigureUsers |
Able to configure Users and their Accounts. |
ConfigureSelf |
Able to change the password for the current user Account. |
ConfigureComponents |
Able to configure components managed by this service. |
Member of Role.v1_2_1.Role
Description | This property is used to indicate if the Role is one of the Redfish Predefined Roles vs a Custom role. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.40 |
Member of Role.v1_2_1.Role
Description | The complete or shortened distinguished name of the directory group. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
Member of Role.v1_2_1.Role
Description | The security identifier of the directory group (for kerberos authentication and Active Directory integration only). |
Type | string or null |
Read Only | True |
Member of Role.v1_2_1.Role
OemPrivileges
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
RemoteConsolePriv |
Able to remotely access the host system Remote Console, including video, keyboard, and mouse control. |
VirtualMediaPriv |
Able to use the Virtual Media feature on the host system. |
VirtualPowerAndResetPriv |
Able to power-cycle or reset the host system. These activities interrupt system availability. A user with this privilege can diagnose the system by using the Generate NMI to System button. |
HostBIOSConfigPriv |
Able to configure Host BIOS Settings. |
HostNICConfigPriv |
Able to configure Host NIC Settings. |
HostStorageConfigPriv |
Able to configure Host Storage Settings. |
SystemRecoveryConfigPriv |
Able to manage the critical recovery firmware images on the Manager's Repository. |
Member of Role.v1_2_1.Role
Description | This property contains the name of the Role. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
@odata.type: "#RoleCollection.RoleCollection"
A Collection of Role resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/roles |
GET |
Link Name | Destination type |
---|---|
Members[] |
Role |
Member of RoleCollection.RoleCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of RoleCollection.RoleCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of RoleCollection.RoleCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#SecureBoot.v1_0_0.SecureBoot"
This resource contains UEFI Secure Boot information. It represents properties for managing the UEFI Secure Boot functionality of a system.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/secureboot |
GET POST PATCH |
Member of SecureBoot.v1_0_0.SecureBoot
Description | Secure Boot state during the current boot cycle. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
Secure Boot is currently enabled. |
Disabled |
Secure Boot is currently disabled. |
Member of SecureBoot.v1_0_0.SecureBoot
Description | Enable or disable UEFI Secure Boot (takes effect on next boot). |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of SecureBoot.v1_0_0.SecureBoot
Description | Current Secure Boot Mode. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
SetupMode |
Secure Boot is currently in Setup Mode. |
UserMode |
Secure Boot is currently in User Mode. |
AuditMode |
Secure Boot is currently in Audit Mode. |
DeployedMode |
Secure Boot is currently in Deployed Mode. |
SecureBoot.ResetKeys Member of SecureBoot.v1_0_0.SecureBoot Action to perform reset of the Secure Boot Keys.
Parameters:
ResetKeysType (string)
This parameter specifies what type of reset action to perform.
Value | Description |
---|---|
ResetAllKeysToDefault | Reset to default Secure Boot keys on next boot. |
DeletePK | Delete Secure Boot platform keys on next boot. |
DeleteAllKeys | Delete all Secure Boot keys on next boot. |
@odata.type: "#ServiceRoot.v1_5_1.ServiceRoot"
The ServiceRoot resource describes the Redfish API service root.
Uri | HTTP Allow |
---|---|
/redfish/v1/ |
GET |
Link Name | Destination type |
---|---|
Registries |
Collection of MessageRegistryFile |
Managers |
Collection of Manager |
AccountService |
AccountService |
JsonSchemas |
Collection of JsonSchemaFile |
UpdateService |
UpdateService |
Oem/Hpe/Links/ResourceDirectory |
HpeiLOResourceDirectory |
SessionService |
SessionService |
EventService |
EventService |
Chassis |
Collection of Chassis |
Systems |
Collection of ComputerSystem |
Links/Sessions |
Collection of Session |
The URI to this account service resource.
AccountService is a link ("@odata.id": URI
) to another resource.
The URI to this chassis resource.
Chassis is a link ("@odata.id": URI
) to another resource.
The URI to the event service resource.
EventService is a link ("@odata.id": URI
) to another resource.
The URI to this registries resource.
JsonSchemas is a link ("@odata.id": URI
) to another resource.
The URI to this managers resource.
Managers is a link ("@odata.id": URI
) to another resource.
Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Specifies whether the iLO has debug firmware flashed. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.40 |
Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Specifies whether the test key is enabled. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.20 |
Member of ServiceRoot.v1_5_1.ServiceRoot
Manager
is an array containing elements of:
Manager[{item}].Blade Manager[{item}].Blade.BayNumber Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Specifies the location of the blade in the enclosure. |
Type | string |
Read Only | True |
Manager[{item}].Blade.EnclosureName Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Specifies the name of the enclosure in which the blade is present. |
Type | string |
Read Only | True |
Manager[{item}].Blade.RackName Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Specifies the name of the rack in which the enclosure is present. |
Type | string |
Read Only | True |
Manager[{item}].DefaultLanguage Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Default language used for the Web interface. |
Type | string |
Read Only | True |
Manager[{item}].FQDN Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Fully qualified domain name of the management processor. |
Type | string or null |
Read Only | True |
Manager[{item}].HostName Member of ServiceRoot.v1_5_1.ServiceRoot
Description | The name of management processor. |
Type | string or null |
Read Only | True |
Manager[{item}].IPManager
Manager[{item}].Languages (array)
Member of ServiceRoot.v1_5_1.ServiceRoot
Languages
is an array containing elements of:
Languages[{item}].Language Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Specifies one of the languages supported by the management processor. |
Type | string |
Read Only | True |
Languages[{item}].TranslationName Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Specifies one of the languages supported by the management processor. |
Type | string |
Read Only | True |
Languages[{item}].Version Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Specifies the version of the management processor in the respective language. |
Type | string |
Read Only | True |
Manager[{item}].ManagerFirmwareVersion Member of ServiceRoot.v1_5_1.ServiceRoot
Description | The major and minor management processor version numbers. |
Type | string |
Read Only | True |
Manager[{item}].ManagerFirmwareVersionPass Member of ServiceRoot.v1_5_1.ServiceRoot
Description | The build or pass number of the management processor version. |
Type | string |
Read Only | True |
Manager[{item}].ManagerType Member of ServiceRoot.v1_5_1.ServiceRoot
Description | The type of the service manager. |
Type | string |
Read Only | True |
Manager[{item}].SelfTestErrors (array)
Member of ServiceRoot.v1_5_1.ServiceRoot
SelfTestErrors
is an array containing elements of:
SelfTestErrors[{item}].SelfTestName Member of ServiceRoot.v1_5_1.ServiceRoot
Description | iLO Self Test Name. |
Type | string |
Read Only | True |
Manager[{item}].Status Member of ServiceRoot.v1_5_1.ServiceRoot See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.Moniker.ADVLIC Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Optional Licensed functionality tier name. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.BMC Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Generic abbreviation for the management processor. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.BSYS Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Product category name. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.CLASS Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Management processor product category. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.FEDGRP Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Default federation group name. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.IPROV Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Product name for provisioning and deployment suite. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.PRODABR Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Abbreviated product name. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.PRODFAM Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Full product family. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.PRODGEN Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Abbreviated product name and generation. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.PRODNAM Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Full product name. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.PRODTAG Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Branded, abbreviated product name. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.STDLIC Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Base licensed functionality tier name. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.SUMABR Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Acronym for update deployment suite. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.SUMGR Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Product name for update deployment suite. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.SYSFAM Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Host system product family. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.VENDABR Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Abbreviated vendor name (like stock ticker). |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.VENDNAM Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Full vendor name. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.WWW Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Top level public internet vendor URI. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.WWWAHSV Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Public internet vendor URI for Active Health viewer. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.WWWBMC Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Public internet vendor URI for the management processor. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.WWWDOC Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Public internet vendor URI for the management processor documentation / manuals. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.WWWERS Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Public internet vendor URI for Embedded Remote Support. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.WWWGLIS Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Public internet vendor URI for management processor licensing infrastructure. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.WWWIOL Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Public internet vendor URI for Online Insight service. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.WWWLIC Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Public internet vendor URI for the management processor. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.WWWLML Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Public internet vendor URI for Learn More Links. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.WWWPASS Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Public internet vendor URI for accessing support account. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.WWWPRV Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Public internet vendor URI for privacy policy statement. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.WWWQSPEC Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Public internet vendor URI for Quick Specs. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.WWWRESTDOC Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Public internet vendor URI for REST API documentation. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.WWWSUP Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Public internet vendor URI for management processor and product support. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Moniker.WWWSWLIC Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Public internet vendor URI for vendor software licensing. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Specifies whether the system identifies as pre-production. |
Type | boolean |
Read Only | True |
Oem.Hpe.Sessions.CertCommonName Member of ServiceRoot.v1_5_1.ServiceRoot
Description | The name of the management processor as it appears in the digital certificate when a secure web GUI session is established to the management processor. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Sessions.CertificateLoginEnabled Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Specifies whether Certificate login is enabled. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Sessions.KerberosEnabled Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Specifies whether Kerberos login is enabled. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Sessions.LDAPAuthLicenced Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Specifies whether a valid license is installed for LDAP use. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Sessions.LDAPEnabled Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Specifies whether LDAP login is enabled. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Sessions.LocalLoginEnabled Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Specifies whether local users can log in. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Sessions.LoginFailureDelay Member of ServiceRoot.v1_5_1.ServiceRoot
Description | The delay (seconds) when a management processor login attempt has failed. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Sessions.LoginHint Oem.Hpe.Sessions.LoginHint.Hint Member of ServiceRoot.v1_5_1.ServiceRoot
Description | The information on how to log in to the management processor. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Sessions.LoginHint.HintPOSTData Oem.Hpe.Sessions.LoginHint.HintPOSTData.Password Member of ServiceRoot.v1_5_1.ServiceRoot
Description | The password for logging in to the management processor. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Sessions.LoginHint.HintPOSTData.UserName Member of ServiceRoot.v1_5_1.ServiceRoot
Description | The user name for logging in to the management processor. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Sessions.SecurityMessage Member of ServiceRoot.v1_5_1.ServiceRoot
Description | The login security banner message that is displayed on the management processor Login page. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Sessions.SecurityOverride Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Specifies whether the security override switch is enabled. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Sessions.ServerName Member of ServiceRoot.v1_5_1.ServiceRoot
Description | The name of the server that this management processor is managing. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of ServiceRoot.v1_5_1.ServiceRoot
System
is an array containing elements of:
System[{item}].Status Member of ServiceRoot.v1_5_1.ServiceRoot See the Redfish standard schema and specification for information on common Status object.
Member of ServiceRoot.v1_5_1.ServiceRoot
Description | The current Redfish service time. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
Member of ServiceRoot.v1_5_1.ServiceRoot
Description | The product associated with this Redfish service. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
ProtocolFeaturesSupported.ExpandQuery ProtocolFeaturesSupported.ExpandQuery.ExpandAll Member of ServiceRoot.v1_5_1.ServiceRoot
Description | This indicates whether the expand support of asterisk (expand all entries) is supported. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.40 |
ProtocolFeaturesSupported.ExpandQuery.Levels Member of ServiceRoot.v1_5_1.ServiceRoot
Description | This indicates whether the expand support of the $levels qualifier is supported by the service. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.40 |
ProtocolFeaturesSupported.ExpandQuery.MaxLevels Member of ServiceRoot.v1_5_1.ServiceRoot
Description | This indicates the maximum number value of the $levels qualifier in expand operations. |
Type | number |
Read Only | True |
Added | iLO 5 1.40 |
ProtocolFeaturesSupported.ExpandQuery.NoLinks Member of ServiceRoot.v1_5_1.ServiceRoot
Description | This indicates whether the expand support of period (expand only entries not in the Links section) is supported. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.40 |
ProtocolFeaturesSupported.FilterQuery Member of ServiceRoot.v1_5_1.ServiceRoot
Description | This indicates whether the filter query parameter is supported. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.40 |
ProtocolFeaturesSupported.OnlyMemberQuery Member of ServiceRoot.v1_5_1.ServiceRoot
Description | This indicates whether Management Processor supports the only query option. |
Type | boolean |
Read Only | True |
ProtocolFeaturesSupported.SelectQuery Member of ServiceRoot.v1_5_1.ServiceRoot
Description | This indicates whether the select query parameter is supported. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.40 |
Member of ServiceRoot.v1_5_1.ServiceRoot
Description | The version of the Redfish service |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The URI to this registries resource.
Registries is a link ("@odata.id": URI
) to another resource.
The URI to this sessions service resource.
SessionService is a link ("@odata.id": URI
) to another resource.
The URI to this systems resource.
Systems is a link ("@odata.id": URI
) to another resource.
The URI to this tasks service resource.
Tasks is a link ("@odata.id": URI
) to another resource.
The URI to the TelemetryService resource.
TelemetryService is a link ("@odata.id": URI
) to another resource.
Member of ServiceRoot.v1_5_1.ServiceRoot
Description | Unique identifier for a service instance. This value should be an exact match of the UUID value returned in a 200OK from an SSDP M-SEARCH request during discovery. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The URI to this UpdateService resource.
UpdateService is a link ("@odata.id": URI
) to another resource.
Member of ServiceRoot.v1_5_1.ServiceRoot
Description | The vendor of the product associated with this Redfish service. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
@odata.type: "#Session.v1_0_0.Session"
The Session resource describes a single connection (session) between a client and a Redfish service instance.
Uri | HTTP Allow |
---|---|
/redfish/v1/sessionservice/sessions/{item} |
GET DELETE |
Member of Session.v1_0_0.Session
Description | User session last-access time |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
Member of Session.v1_0_0.Session
Description | User session login time |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
Member of Session.v1_0_0.Session
Description | Indicates whether this is a session I own. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Privileges.HostBIOSConfigPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to configure Host Bios Settings. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Privileges.HostNICConfigPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to configure Host NIC Settings. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Privileges.HostStorageConfigPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to configure Host Storage Settings. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Privileges.LoginPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to log in to the management processor. All local accounts have the login privilege. This privilege is added automatically if it is not specified. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Privileges.RemoteConsolePriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to remotely access the host system Remote Console, including video, keyboard, and mouse control. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Privileges.SystemRecoveryConfigPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to manage the critical recovery firmware images on the iLO Repository. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Privileges.UserConfigPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to add, edit, and delete local management processor user accounts. A user with this privilege can change privileges for all users. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Privileges.VirtualMediaPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to use the Virtual Media feature on the host system. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Privileges.VirtualPowerAndResetPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to power-cycle or reset the host system. These activities interrupt system availability. A user with this privilege can diagnose the system by using the Generate NMI to System button. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Oem.Hpe.Privileges.iLOConfigPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to configure most management processor settings, including security settings, and to remotely update the management processor firmware. This privilege does not enable local user account administration. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Member of Session.v1_0_0.Session
Description | Login details of the user |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of Session.v1_0_0.Session
Description | LDAP user is identified by its distinguished name (DN). |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of Session.v1_0_0.Session
Description | User session expire time |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
Member of Session.v1_0_0.Session
Description | IP address of the user |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of Session.v1_0_0.Session
Description | Session source |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Web UI |
RBSU |
Remote Console |
SSH |
IPMI/RMCP |
SM-CLP |
RIBCL |
RESTHost |
RIBCLHost |
WSMgmt |
Telnet |
Federation |
USBFrontPort |
REST |
Unknown |
Member of Session.v1_0_0.Session
Description | User type |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Local |
Directory |
Single Sign On |
Kerberos |
Trusted Key |
Security Override |
System |
Federation |
Member of Session.v1_0_0.Session
Description | Name to use to log in to the management processor. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
@odata.type: "#SessionCollection.SessionCollection"
A Collection of Session resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/sessionservice/sessions |
GET POST |
Link Name | Destination type |
---|---|
Oem/Hpe/Links/MySession |
Session |
Members[] |
Session |
Member of SessionCollection.SessionCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of SessionCollection.SessionCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of SessionCollection.SessionCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#SessionService.v1_0_0.SessionService"
The SessionService resource describes the BMC Redfish Session Service. It represents the properties for the service itself and has links to the actual list of sessions.
Uri | HTTP Allow |
---|---|
/redfish/v1/sessionservice |
GET PATCH |
Link Name | Destination type |
---|---|
Sessions |
Collection of Session |
Member of SessionService.v1_0_0.SessionService
Description | This indicates whether this service is enabled. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of SessionService.v1_0_0.SessionService
Description | This is the number of seconds of inactivity that a session may have before the session service closes the session due to inactivity. |
Type | integer |
Read Only | False |
Added | iLO 5 1.10 |
This property references a Collection resource of Sessions.
Sessions is a link ("@odata.id": URI
) to another resource.
Member of SessionService.v1_0_0.SessionService See the Redfish standard schema and specification for information on common Status object.
@odata.type: "#SmartStorageConfig.v2_0_0.SmartStorageConfig"
Smart Storage Configuration Schema
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/smartstorageconfig |
GET |
/redfish/v1/systems/{item}/smartstorageconfig/settings |
GET PATCH |
Link Name | Destination type |
---|---|
@Redfish.Settings/SettingsObject |
SmartStorageConfig |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Actions
is an array containing elements of:
Actions[{item}].Action Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | The action to perform |
Type | string |
Read Only | False |
Actions[{item}].ErasePattern Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | The erase pattern used to erase the drive |
Type | string |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
SanitizeRestrictedBlockErase |
Use the restricted block erase sanitize block erase method to erase a drive |
SanitizeUnrestrictedBlockErase |
Use the unrestricted block erase sanitize method to erase a drive |
SanitizeRestrictedOverwrite |
Use the restricted overwrite sanitize method to erase a drive |
SanitizeUnrestrictedOverwrite |
Use the unrestricted overwrite sanitize method to erase a drive |
SanitizeRestrictedCryptoScramble |
Use the unrestricted cryptographic scramble sanitize method to erase a drive |
SanitizeUnrestrictedCryptoScramble |
Use the unrestricted cryptographic scramble sanitize method to erase a drive |
OnePass |
Use the controller-based one pass erase method that writes zeroes to every sector of the drive |
TwoPass |
Use the controller-based two pass erase method that writes random data to every sector of the drive on the first pass, and zeroes on the second pass |
ThreePass |
Use the controller-based three pass erase method that writes random data to every sector of the drive on the first two passes, and zeroes on the third pass |
Actions[{item}].PhysicalDriveList (array)
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
PhysicalDriveList
is an array containing elements of:
Description | Physical drive in the format specified in DriveLocationFormat |
Type | string |
Read Only | True |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | This indicates the number of parallel surface scans the controller allows |
Type | integer or null |
Read Only | False |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | The value of the field indicates whether or not data destructive actions are allowed on the controller |
Type | string |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Strict |
Data destructive actions are not allowed |
Permissive |
Logical drive delete actions will be ignored |
Disabled |
Data destructive actions are allowed |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | Enables the controller to attempt to improve performance on RAID 5/50/6(ADG)/60 logical drives when one or more physical drives in the logical drive are failed |
Type | string or null |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Enabled |
The controller will attempt to improve performance by buffering physical drive requests |
Disabled |
The controller will not buffer, which may result in reading from the same drive multiple times |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | The format of the physical drive locations on this controller |
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
```ControllerPort:Box:Bay[ | ControllerPort:Box:Bay]``` |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | Enables or disables the write cache of the physical drives attached to the controller |
Type | string or null |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Enabled |
The write cache of the physical drives attached to the controller are enabled |
Disabled |
The write cache of the physical drives attached to the controller are enabled |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | Enables the controller to sort requests to a physical drive |
Type | string or null |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Enabled |
The controller will sort the requests to minimize the amount of seeking the drive must perform in order to reduce seek times |
Disabled |
The controller will perform the requests as they are recieved in order to improve request throughput |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | This indicates the type of encryption configured on the controller |
Type | string |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
ExpressLocal |
Express local encryption is configured and the controller is being encrypted with internally generated keys |
None |
Encryption is not configured on the controller |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | The value of this field indicates whether or not the user has accepted the encryption EULA |
Type | string or null |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Accept |
The user has read and accepted the encryption EULA |
Decline |
The user has not read and accepted the encryption EULA |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | The level of priority that transformations have over handling current operating system requests |
Type | string or null |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
High |
Transformations will complete as fast as possible at the expense of normal I/O |
Medium |
Transformations will perform with some impact on normal I/O |
Low |
Transformations will perform only when normal I/O is not occurring and may take longer to complete |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | This allows the controller to process certain high-latency requests after a delay that may time out when elevator sorting |
Type | string or null |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Default |
The controller will rely only on elevator sorting |
Low250 |
The controller will apply a cutoff value of 250ms when suspending elevator sorting |
Middle100 |
The controller will apply a cutoff value of 100ms when suspending elevator sorting |
Middle50 |
The controller will apply a cutoff value of 50ms when suspending elevator sorting |
Aggressive30 |
The controller will apply a cutoff value of 30ms when suspending elevator sorting |
Aggressive10 |
The controller will apply a cutoff value of 10ms when suspending elevator sorting |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | Enables the controller to update data on RAID 6(ADG) and 60 volumes based on parity information when an inconsistency is discovered during surface scan |
Type | string or null |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Enabled |
The controller will update the data on the drives based on the parity information |
Disabled |
The controller will only update the parity information and leave the data untouched |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | The location of the controller |
Type | string |
Read Only | True |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | The format of the Location property on this controller |
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
PCISlot |
The location of the controller is given as a PCI slot number |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
LogicalDrives
is an array containing elements of:
LogicalDrives[{item}].Accelerator Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | The acceleration method of the logical drive |
Type | string |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
None |
Logical drive acceleration is disabled |
ControllerCache |
Read and writes to the logical drive are being cached by the controller |
IOBypass |
For logical drives on SSDs, read and write information directly from the drive |
LogicalDrives[{item}].Actions (array)
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Actions
is an array containing elements of:
Actions[{item}].Action Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | The action to perform |
Type | string |
Read Only | False |
LogicalDrives[{item}].BlockSizeBytes Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | The block size of the disk drive in bytes |
Type | integer |
Read Only | False |
LogicalDrives[{item}].CapacityBlocks Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | Total usable capacity available on this logical drive in block units. Set to -1 to use all remaining space for maximum size |
Type | integer |
Read Only | False |
LogicalDrives[{item}].CapacityGiB Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | Total usable capacity available on this logical drive in GiB units. Set to -1 to use all remaining space for maximum size |
Type | integer |
Read Only | False |
LogicalDrives[{item}].DataDrives
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
LogicalDrives[{item}].DataDrives (array)
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
DataDrives
is an array containing elements of:
Description | Physical drive in the format specified in DriveLocationFormat |
Type | string |
Read Only | True |
LogicalDrives[{item}].DataDrives LogicalDrives[{item}].DataDrives.DataDriveCount Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | Specify the number of data drives for this logical drive |
Type | integer |
Read Only | False |
LogicalDrives[{item}].DataDrives.DataDriveInterfaceType Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | Specify the interface type for the data drives for this logical drive |
Type | string |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
SAS |
Use SAS drives when creating the logical drive |
SATA |
Use SATA drives when creating the logical drive |
LogicalDrives[{item}].DataDrives.DataDriveLocation Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | Specify the location of the data drives for this logical drive |
Type | string |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Internal |
Drives that are attached to an internal port of the controller (front drives) |
External |
Drives that are attached to an external port of the controller (JBOD drives) |
LogicalDrives[{item}].DataDrives.DataDriveMediaType Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | Specify the media type for the data drives for this logical drive |
Type | string |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
HDD |
Use spindle drives when creating the logical drive |
SSD |
Use solid state drives when creating the logical drive |
LogicalDrives[{item}].DataDrives.DataDriveMinimumSizeGiB Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | Specify the minimum size for the data drive(s) used to create the logical drive |
Type | integer |
Read Only | False |
LogicalDrives[{item}].LegacyBootPriority Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | The boot priority of this logical drive |
Type | string |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Primary |
This logical drive is the primary boot volume |
Secondary |
This logical drive is the secondary boot volume |
All |
This logical drive is both the primary and secondary boot volume |
None |
This logical drive has no legacy boot priority |
LogicalDrives[{item}].LogicalDriveName Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | Label given to the logical drive |
Type | string |
Read Only | False |
LogicalDrives[{item}].LogicalDriveNumber Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | Logical drive number |
Type | integer |
Read Only | True |
LogicalDrives[{item}].ParityGroupCount Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | The number of parity groups to use in the logical drive; only valid for certain RAID levels |
Type | integer |
Read Only | False |
LogicalDrives[{item}].ParityInitializationType Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | When creating a logical drive with a RAID level that requires parity, parity blocks can be initialized with two different methods |
Type | string |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Default |
Parity blocks are initialized in the background and the logical drive is available during this time |
Rapid |
Both data and parity blocks are initialized in the foreground and the logical drive will not be available to the operating system until initialization completes |
LogicalDrives[{item}].Raid Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | The current RAID level configured on the logical drive |
Type | string |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Raid0 |
There is no fault tolerance used on this logical drive |
Raid1 |
Two sets of duplicate data is being stored on a pair of drives |
Raid1ADM |
Three sets of duplicate data is being stored on a trio of drives |
Raid10 |
Data is duplicated and striped across pairs of disk drives |
Raid10ADM |
Data is duplicated and striped across trios of disk drives |
Raid5 |
Fault tolerance is achieved by storing parity data across 3 or more disk drives |
Raid50 |
Fault tolerance is achieved by storing parity data and striping the data across 6 or more disk drives |
Raid6 |
Fault tolerance is achieved by storing multiple sets parity data across 4 or more disk drives |
Raid60 |
Fault tolerance is achieved by storing multiple sets parity data and striping the data across 8 or more disk drives |
LogicalDrives[{item}].SpareDrives
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
LogicalDrives[{item}].SpareDrives (array)
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
SpareDrives
is an array containing elements of:
Description | Physical drive in the format specified in DriveLocationFormat |
Type | string |
Read Only | True |
LogicalDrives[{item}].SpareDrives LogicalDrives[{item}].SpareDrives.SpareDriveCount Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | Specify the number of spare drives for this logical drive |
Type | integer |
Read Only | False |
LogicalDrives[{item}].SpareRebuildMode Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | Type of spare drive used with this logical drive |
Type | string |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Dedicated |
The spare drive temporarily takes over a failed data drive; when the failed data drive is replaced, the spare drive becomes idle again |
Roaming |
The spare drive replaces the failed data drive |
LogicalDrives[{item}].StripSizeBytes Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | The strip size of the logical drive in bytes |
Type | integer |
Read Only | False |
LogicalDrives[{item}].StripeSizeBytes Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | The stripe size of the logical drive in bytes |
Type | integer |
Read Only | False |
LogicalDrives[{item}].VolumeUniqueIdentifier Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | Logical drive volume unique identifier |
Type | string |
Read Only | True |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | This sets the monitor and performance delay on the controller. Valid values range from 0 to 1440 seconds. Set to 60 seconds for default settings and 0 seconds for video-on-demand optimized setting |
Type | integer or null |
Read Only | False |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | This indicates if the controller will continue to use write cache even if the backup power source is not available |
Type | string or null |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Enabled |
The controller will continue to use write cache even if the backup power source is not available |
Disabled |
The controller will not continue to use write cache even if the backup power source is not available |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
PhysicalDrives
is an array containing elements of:
PhysicalDrives[{item}].LegacyBootPriority Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | The boot priority of this physical drive |
Type | string |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Primary |
This physical drive is the primary boot volume |
Secondary |
This physical drive is the secondary boot volume |
All |
This physical drive is both the primary and secondary boot volume |
None |
This physical drive has no legacy boot priority |
PhysicalDrives[{item}].PhysicalDriveNumber Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | Physical drive number |
Type | integer |
Read Only | True |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Ports
is an array containing elements of:
Ports[{item}].OperatingModeAfterReboot Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | The operating mode of this port after a reboot |
Type | string |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Mixed |
The port will be functioning in mixed mode after rebooting. Unassigned drives will be exposed to the OS |
Ports[{item}].PortIndex Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | The port index |
Type | integer |
Read Only | True |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | The power mode of the controller after a reboot |
Type | string |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Invalid |
The controller will be operating in an unknown power mode after a reboot |
MinPower |
The controller will be operating in minimum power mode after a reboot |
Balanced |
The controller will be operating in a balanced mode after a reboot |
MaxPerformance |
The controller will be operating in maximum performance power mode after a reboot |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | Enables or disables predictive spare rebuild mode |
Type | string or null |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Enabled |
Spare drives will replace physical drives that are predicted to fail preemptively |
Disabled |
Spare drives will replace physical drives only when they fail |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | This sets the maximum number of requests the controller will submit to a drive at any given time |
Type | string or null |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Queue2 |
2 requests |
Queue4 |
4 requests |
Queue8 |
8 requests |
Queue16 |
16 requests |
Queue32 |
32 requests |
Automatic |
Automatically determine the best queue depth for the controller |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | This indicates the percentage of cache used for read cache on the controller, with the rest of the cache being used for write cache |
Type | integer or null |
Read Only | False |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | The level of priority that rebuilds have over handling current operating system requests |
Type | string or null |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
High |
Rebuilds will complete as fast as possible at the expense of normal I/O |
Medium |
Rebuilds will perform with some impact on normal I/O |
Low |
Rebuilds will perform only when normal I/O is not occurring and may take longer to complete |
RapidHigh |
Rebuilds will complete as fast as possible at the expense of normal I/O |
RapidMediumHigh |
Rebuilds will perform with an impact on normal I/O |
RapidMedium |
Rebuilds will perform with some impact on normal I/O |
RapidLow |
Rebuilds will perform only when normal I/O is not occurring and may take longer to complete |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | Sets the delay of the controller before beginning surface scan analysis. Only valid if SurfaceScanAnalysisPriority is Idle |
Type | integer or null |
Read Only | False |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | Priority that the controller takes to find and correct disk surface errors |
Type | string or null |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Disabled |
Surface scan is disabled and may lead to data loss |
High |
Surface scan commands will be sent with the host I/O, resulting in faster scanning, but may inpact host I/O performance |
Medium |
Surface scan commands have a medium priority, and will have some impact on host I/O performance |
Low |
Surface scan commands have a low priority, and will have little impact on host I/O performance |
Idle |
Surface scan commands will ony be issued when no host I/O is present after a delay |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | Enables or Disables survival mode |
Type | string |
Read Only | False |
The following are the supported values:
Value | Description |
---|---|
Enabled |
The controller will throttle dynamic power settings to their minimum when temperatures exceed the warning threshold |
Disabled |
The controller will not throttle dynamic power settings |
Member of SmartStorageConfig.v2_0_0.SmartStorageConfig
Description | This value sets the write cache bypass threshold, ranging from 16 KiB to 1040 KiB in multiples of 16 KiB, where all writes larger than the specified value in KiB units will bypass the write cache and be written directly to the disk for non-parity RAID volumes |
Type | integer or null |
Read Only | False |
@odata.type: "#SoftwareInventory.v1_0_0.SoftwareInventory"
The SoftwareInventory resource describes the inventory of software or firmware components.
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/firmwareinventory/{item} |
GET |
/redfish/v1/updateservice/softwareinventory/{item} |
GET |
Member of SoftwareInventory.v1_0_0.SoftwareInventory
Description | DeviceType GUID rendered by iLO for certain items iLO knows how to flash, and omitted for all other items. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of SoftwareInventory.v1_0_0.SoftwareInventory
Description | Friendly text string - same as 'Location' in fw inventory - omitted if not available. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of SoftwareInventory.v1_0_0.SoftwareInventory
Description | UEFI Device Path if a PCI Device - omitted otherwise. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of SoftwareInventory.v1_0_0.SoftwareInventory
Targets
is an array containing elements of:
Description | A GUID indicating iLO's knowledge of a possible correlation GUIDs vs. components. |
Type | string or null |
Read Only | True |
Member of SoftwareInventory.v1_0_0.SoftwareInventory See the Redfish standard schema and specification for information on common Status object.
Member of SoftwareInventory.v1_0_0.SoftwareInventory
Description | This is true if the item is updatable. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of SoftwareInventory.v1_0_0.SoftwareInventory
Description | same as 'VersionString' in existing FwSwVersionInventory |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
@odata.type: "#SoftwareInventoryCollection.SoftwareInventoryCollection"
A Collection of SoftwareInventory resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/firmwareinventory |
GET |
/redfish/v1/updateservice/softwareinventory |
GET |
Link Name | Destination type |
---|---|
Members[] |
SoftwareInventory |
Member of SoftwareInventoryCollection.SoftwareInventoryCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of SoftwareInventoryCollection.SoftwareInventoryCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of SoftwareInventoryCollection.SoftwareInventoryCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#Storage.v1_5_0.Storage"
Storage defines a storage subsystem and its respective properties. A storage subsystem represents a set of storage controllers (physical or virtual) and the resources such as volumes that can be accessed from that subsystem.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/storage/{interface}/{item} |
GET |
Link Name | Destination type |
---|---|
Volumes |
Collection of Volume |
Links/Enclosures[] |
Chassis |
StorageControllers[] |
Storage |
Drives[] |
Drive |
Member of Storage.v1_5_0.Storage
Drives
is an array containing elements of:
Drives[{item}].@odata.id Member of Storage.v1_5_0.Storage
Type | string |
Read Only | True |
Format | uri-reference |
Member of Storage.v1_5_0.Storage See the Redfish standard schema and specification for information on common Status object.
Member of Storage.v1_5_0.Storage
StorageControllers
is an array containing elements of:
StorageControllers[{item}].@odata.id Member of Storage.v1_5_0.Storage
Type | string |
Read Only | True |
Format | uri-reference |
StorageControllers[{item}].@odata.type Member of Storage.v1_5_0.Storage
Type | string |
Read Only | True |
StorageControllers[{item}].Manufacturer Member of Storage.v1_5_0.Storage
Description | Controller Manufacturer name. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
StorageControllers[{item}].MemberId Member of Storage.v1_5_0.Storage
Description | This is the identifier for the member within the collection. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
StorageControllers[{item}].Model Member of Storage.v1_5_0.Storage
Description | Controller model name. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
StorageControllers[{item}].PCIeInterface StorageControllers[{item}].PCIeInterface.LanesInUse Member of Storage.v1_5_0.Storage
Description | This is the number of PCIe lanes in use by this device. |
Type | integer or null |
Read Only | True |
StorageControllers[{item}].PCIeInterface.MaxLanes Member of Storage.v1_5_0.Storage
Description | This is the number of PCIe lanes supported by this device. |
Type | integer or null |
Read Only | True |
StorageControllers[{item}].PCIeInterface.MaxPCIeType Member of Storage.v1_5_0.Storage
Description | The highest version of the PCIe specification supported by this device. |
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Gen1 |
A PCIe v1.0 slot. |
Gen2 |
A PCIe v2.0 slot. |
Gen3 |
A PCIe v3.0 slot. |
Gen4 |
A PCIe v4.0 slot. |
Gen5 |
A PCIe v5.0 slot. |
StorageControllers[{item}].PCIeInterface.PCIeType Member of Storage.v1_5_0.Storage
Description | The version of the PCIe specification in use by this device. |
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Gen1 |
A PCIe v1.0 slot. |
Gen2 |
A PCIe v2.0 slot. |
Gen3 |
A PCIe v3.0 slot. |
Gen4 |
A PCIe v4.0 slot. |
Gen5 |
A PCIe v5.0 slot. |
StorageControllers[{item}].SerialNumber Member of Storage.v1_5_0.Storage
Description | Controller serial number. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
StorageControllers[{item}].Status Member of Storage.v1_5_0.Storage See the Redfish standard schema and specification for information on common Status object.
StorageControllers[{item}].SupportedControllerProtocols (array)
Member of Storage.v1_5_0.Storage
SupportedControllerProtocols
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value |
---|
PCIe |
StorageControllers[{item}].SupportedDeviceProtocols (array)
Member of Storage.v1_5_0.Storage
SupportedDeviceProtocols
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value |
---|
USB |
SATA |
NVMe |
A reference to the Volumes associated with this storage system.
Volumes is a link ("@odata.id": URI
) to another resource.
@odata.type: "#StorageCollection.StorageCollection"
A Collection of Storage resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/storage |
GET |
Link Name | Destination type |
---|---|
Members[] |
Storage |
Member of StorageCollection.StorageCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of StorageCollection.StorageCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of StorageCollection.StorageCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#Task.v1_3_0.Task"
The Task resource describes a specific Task scheduled by or being executed by a Redfish service's Task Service.
Uri | HTTP Allow |
---|---|
/redfish/v1/taskservice/tasks/{item} |
GET |
Member of Task.v1_3_0.Task
Description | The date-time stamp that the task was last completed. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
Format | date-time |
Member of Task.v1_3_0.Task
Messages
is an array containing elements of:
Messages[{item}].Message Member of Task.v1_3_0.Task
Description | This is the human readable message, if provided. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
Messages[{item}].MessageArgs (array)
Member of Task.v1_3_0.Task
MessageArgs
is an array containing elements of:
Type | string |
Read Only | True |
Messages[{item}].MessageId Member of Task.v1_3_0.Task
Description | This is the key for this message which can be used to look up the message in a message registry. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
Messages[{item}].RelatedProperties (array)
Member of Task.v1_3_0.Task
RelatedProperties
is an array containing elements of:
Type | string |
Read Only | True |
Messages[{item}].Resolution Member of Task.v1_3_0.Task
Description | Used to provide suggestions on how to resolve the situation that caused the error. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
Messages[{item}].Severity Member of Task.v1_3_0.Task
Description | This is the severity of the event. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
OK |
Normal |
Warning |
A condition exists that requires attention |
Critical |
A critical condition exists that requires immediate attention |
Payload.HttpHeaders (array)
Member of Task.v1_3_0.Task
HttpHeaders
is an array containing elements of:
Type | string |
Read Only | True |
Payload.HttpOperation Member of Task.v1_3_0.Task
Description | The HTTP operation to perform to execute this Task. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
Payload.JsonBody Member of Task.v1_3_0.Task
Description | This property contains the JSON payload to use in the execution of this Task. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
Payload.TargetUri Member of Task.v1_3_0.Task
Description | The URI of the target for this task. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
Format | uri-reference |
Member of Task.v1_3_0.Task
Description | The date-time stamp that the task was last started. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
Format | date-time |
Member of Task.v1_3_0.Task
Description | The URI of the Task Monitor for this task. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
Format | uri-reference |
Member of Task.v1_3_0.Task
Description | The state of the task. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
New |
A new task. |
Starting |
Task is starting. |
Running |
Task is running normally. |
Suspended |
Task has been suspended. |
Interrupted |
Task has been interrupted. |
Pending |
Task is pending and has not started. |
Stopping |
Task is in the process of stopping. |
Completed |
Task has completed. |
Killed |
Task was terminated. |
Exception |
Task has stopped due to an exception condition. |
Service |
Task is running as a service. |
Member of Task.v1_3_0.Task
Description | This is the completion status of the task. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
OK |
Normal. |
Warning |
A condition exists that requires attention. |
Critical |
A critical condition exists that requires immediate attention. |
@odata.type: "#TaskCollection.TaskCollection"
A Collection of Task resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/taskservice/tasks |
GET |
Link Name | Destination type |
---|---|
Members[] |
Task |
Member of TaskCollection.TaskCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of TaskCollection.TaskCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of TaskCollection.TaskCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#TaskService.v1_1_1.TaskService"
The TaskService resource describes the Task service. It represents the properties for the service itself and has links to the actual list of tasks.
Uri | HTTP Allow |
---|---|
/redfish/v1/taskservice |
GET |
Link Name | Destination type |
---|---|
Tasks |
Collection of Task |
Member of TaskService.v1_1_1.TaskService
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Manual |
Completed tasks are not automatically overwritten. |
Oldest |
Oldest completed tasks are overwritten. |
Member of TaskService.v1_1_1.TaskService
Description | The current DateTime (with offset) setting that the task service is using. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
Format | date-time |
Member of TaskService.v1_1_1.TaskService
Description | Send an Event upon Task State Change. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.40 |
Member of TaskService.v1_1_1.TaskService
Description | This indicates whether this service is enabled. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.40 |
Member of TaskService.v1_1_1.TaskService See the Redfish standard schema and specification for information on common Status object.
This property references a resource of type Collection with a MemberType of TaskCollection.
Tasks is a link ("@odata.id": URI
) to another resource.
@odata.type: "#TelemetryService.v1_0_0.TelemetryService"
The TelemetryService resource describes the Metrics Service.
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice |
Link Name | Destination type |
---|---|
MetricReports |
Collection of MetricReport |
MetricReportDefinitions |
Collection of MetricDefinition |
Triggers |
Collection of Trigger |
Member of TelemetryService.v1_0_0.TelemetryService
Description | The maximum number of metric reports supported by this service. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.40 |
A link to the collection of Metric Definitions.
MetricDefinitions is a link ("@odata.id": URI
) to another resource.
A link to the collection of Metric Reports.
MetricReportDefinitions is a link ("@odata.id": URI
) to another resource.
A link to the collection of Metric Reports.
MetricReports is a link ("@odata.id": URI
) to another resource.
Member of TelemetryService.v1_0_0.TelemetryService
Description | The minimum time interval between collections supported by this service. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.40 |
Member of TelemetryService.v1_0_0.TelemetryService See the Redfish standard schema and specification for information on common Status object.
Member of TelemetryService.v1_0_0.TelemetryService
SupportedCollectionFunctions
is an array containing elements of:
Description | An operation to perform over the sample. |
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
Average |
An averaging function. |
Maximum |
A maximum function. |
Minimum |
A minimum function. |
Summation |
A summation function. |
A link to the collection of Triggers, which apply to metrics.
Triggers is a link ("@odata.id": URI
) to another resource.
@odata.type: "#Thermal.v1_1_0.Thermal"
The Thermal resource describes the system thermal metrics. It represents the properties for temperature and cooling.
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/thermal |
GET |
Member of Thermal.v1_1_0.Thermal
Fans
is an array containing elements of:
Fans[{item}].@odata.id Member of Thermal.v1_1_0.Thermal
Type | string |
Read Only | True |
Format | uri-reference |
Fans[{item}].CorrelatableID Member of Thermal.v1_1_0.Thermal
Description | The CorrelatableID for this fan. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Fans[{item}].LowerThresholdCritical Member of Thermal.v1_1_0.Thermal
Description | Below normal range but not yet fatal. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Fans[{item}].LowerThresholdFatal Member of Thermal.v1_1_0.Thermal
Description | Below normal range and is fatal. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Fans[{item}].LowerThresholdNonCritical Member of Thermal.v1_1_0.Thermal
Description | Below normal range. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Fans[{item}].MaximumValue Member of Thermal.v1_1_0.Thermal
Description | Maximum value for CurrentReading. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Fans[{item}].MemberId Member of Thermal.v1_1_0.Thermal
Description | This is the identifier for the member within the collection. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
Fans[{item}].MinimumValue Member of Thermal.v1_1_0.Thermal
Description | Minimum value for CurrentReading. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Fans[{item}].Oem.Hpe.HotPluggable Member of Thermal.v1_1_0.Thermal
Description | Indicates if the fan can be replaced while server is running. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Fans[{item}].Oem.Hpe.Location Member of Thermal.v1_1_0.Thermal
Description | Indicates the component (i.e. CPU, Memory, and Storage) that the fan is being used to cool. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
System |
System Board |
I/O Board |
CPU |
Memory |
Storage |
Removable Media |
Power Supply |
Ambient |
Chassis |
Bridge Board |
Exhaust |
Processor Bay |
IO Bay |
Blade Slot |
Virtual |
Fans[{item}].Oem.Hpe.Redundant Member of Thermal.v1_1_0.Thermal
Description | Indicates if the fan is in a redundant configuration. |
Type | boolean |
Read Only | True |
Added | iLO 5 1.10 |
Fans[{item}].PhysicalContext Member of Thermal.v1_1_0.Thermal
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Room |
The room |
Intake |
The intake point of the chassis |
Exhaust |
The exhaust point of the chassis |
Front |
The front of the chassis |
Back |
The back of the chassis |
Upper |
The upper portion of the chassis |
Lower |
The lower portion of the chassis |
CPU |
A Processor (CPU) |
GPU |
A Graphics Processor (GPU) |
Backplane |
A backplane within the chassis |
SystemBoard |
The system board (PCB) |
PowerSupply |
A power supply |
VoltageRegulator |
A voltage regulator device |
StorageDevice |
A storage device |
NetworkingDevice |
A networking device |
ComputeBay |
Within a compute bay |
StorageBay |
Within a storage bay |
NetworkBay |
Within a networking bay |
ExpansionBay |
Within an expansion bay |
PowerSupplyBay |
Within a power supply bay |
Fans[{item}].Reading Member of Thermal.v1_1_0.Thermal
Description | The current speed of the fan. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Fans[{item}].ReadingUnits Member of Thermal.v1_1_0.Thermal
Description | Units for the CurrentReading. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value |
---|
Null |
Percent |
Fans[{item}].Status Member of Thermal.v1_1_0.Thermal See the Redfish standard schema and specification for information on common Status object.
Fans[{item}].UpperThresholdCritical Member of Thermal.v1_1_0.Thermal
Description | Above normal range but not yet fatal. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Fans[{item}].UpperThresholdFatal Member of Thermal.v1_1_0.Thermal
Description | Above normal range and is fatal. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Fans[{item}].UpperThresholdNonCritical Member of Thermal.v1_1_0.Thermal
Description | Above normal range. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Thermal.v1_1_0.Thermal
Description | System-wide setting for fan +/- percentage adjustment. |
Type | integer |
Read Only | False |
Added | iLO 5 1.10 |
Member of Thermal.v1_1_0.Thermal See the Redfish standard schema and specification for information on common Status object.
Member of Thermal.v1_1_0.Thermal
Temperatures
is an array containing elements of:
Temperatures[{item}].@odata.id Member of Thermal.v1_1_0.Thermal
Type | string |
Read Only | True |
Format | uri-reference |
Temperatures[{item}].CorrelatableID Member of Thermal.v1_1_0.Thermal
Description | The CorrelatableID for this temperature sensor. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Temperatures[{item}].LowerThresholdCritical Member of Thermal.v1_1_0.Thermal
Description | Below normal range but not yet fatal. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
Temperatures[{item}].LowerThresholdFatal Member of Thermal.v1_1_0.Thermal
Description | Below normal range and is fatal. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
Temperatures[{item}].LowerThresholdNonCritical Member of Thermal.v1_1_0.Thermal
Description | Below normal range. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
Temperatures[{item}].MaximumValue Member of Thermal.v1_1_0.Thermal
Description | Maximum value for CurrentReading. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Temperatures[{item}].MemberId Member of Thermal.v1_1_0.Thermal
Description | This is the identifier for the member within the collection. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
Temperatures[{item}].MinimumValue Member of Thermal.v1_1_0.Thermal
Description | Minimum value for CurrentReading. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Temperatures[{item}].Oem.Hpe.LocationXmm Member of Thermal.v1_1_0.Thermal
Description | The location of the sensor, in millimeters, along the X axis from the logical reference point. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Temperatures[{item}].Oem.Hpe.LocationYmm Member of Thermal.v1_1_0.Thermal
Description | The location of the sensor, in millimeters, along the Y axis from the logical reference point. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Temperatures[{item}].Oem.Hpe.LocationZmm Member of Thermal.v1_1_0.Thermal
Description | The location of the sensor, in millimeters, along the Z axis from the logical reference point. |
Type | integer |
Read Only | True |
Added | iLO 5 1.10 |
Temperatures[{item}].PhysicalContext Member of Thermal.v1_1_0.Thermal
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Room |
The room |
Intake |
The intake point of the chassis |
Exhaust |
The exhaust point of the chassis |
Front |
The front of the chassis |
Back |
The back of the chassis |
Upper |
The upper portion of the chassis |
Lower |
The lower portion of the chassis |
CPU |
A Processor (CPU) |
GPU |
A Graphics Processor (GPU) |
Backplane |
A backplane within the chassis |
SystemBoard |
The system board (PCB) |
PowerSupply |
A power supply |
VoltageRegulator |
A voltage regulator device |
StorageDevice |
A storage device |
NetworkingDevice |
A networking device |
ComputeBay |
Within a compute bay |
StorageBay |
Within a storage bay |
NetworkBay |
Within a networking bay |
ExpansionBay |
Within an expansion bay |
PowerSupplyBay |
Within a power supply bay |
Temperatures[{item}].ReadingCelsius Member of Thermal.v1_1_0.Thermal
Description | The current reading of the temperature sensor. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Temperatures[{item}].SensorNumber Member of Thermal.v1_1_0.Thermal
Description | A numerical identifier to represent the temperature sensor. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Temperatures[{item}].Status Member of Thermal.v1_1_0.Thermal See the Redfish standard schema and specification for information on common Status object.
Temperatures[{item}].UpperThresholdCritical Member of Thermal.v1_1_0.Thermal
Description | Above normal range but not yet fatal. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
Temperatures[{item}].UpperThresholdFatal Member of Thermal.v1_1_0.Thermal
Description | Above normal range and is fatal. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
Temperatures[{item}].UpperThresholdNonCritical Member of Thermal.v1_1_0.Thermal
Description | The noncritical temperature threshold. |
Type | number or null |
Read Only | True |
Added | iLO 5 1.10 |
@odata.type: "#Triggers.v1_0_0.Triggers"
The Triggers resource describes the a metric trigger, which apply to metrics.
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/triggers/{item} |
Member of Triggers.v1_0_0.Triggers
MetricProperties
is an array containing elements of:
Type | string or null |
Read Only | True |
Member of Triggers.v1_0_0.Triggers
Description | Specifies the type of metric for which the trigger is configured. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Numeric |
The trigger is for numeric sensor. |
Discrete |
The trigger is for a discrete sensor. |
NumericThresholds.LowerCritical NumericThresholds.LowerCritical.Activation Member of Triggers.v1_0_0.Triggers
Description | The direction of crossing that activates this threshold. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Increasing |
Value increases above the threshold. |
Decreasing |
Value decreases below the threshold. |
Either |
Value crosses the threshold in either direction. |
NumericThresholds.LowerCritical.DwellTime Member of Triggers.v1_0_0.Triggers
Description | The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.40 |
NumericThresholds.LowerCritical.Reading Member of Triggers.v1_0_0.Triggers
Description | The threshold value. |
Type | number or null |
Read Only | False |
Added | iLO 5 1.40 |
NumericThresholds.LowerWarning NumericThresholds.LowerWarning.Activation Member of Triggers.v1_0_0.Triggers
Description | The direction of crossing that activates this threshold. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Increasing |
Value increases above the threshold. |
Decreasing |
Value decreases below the threshold. |
Either |
Value crosses the threshold in either direction. |
NumericThresholds.LowerWarning.DwellTime Member of Triggers.v1_0_0.Triggers
Description | The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.40 |
NumericThresholds.LowerWarning.Reading Member of Triggers.v1_0_0.Triggers
Description | The threshold value. |
Type | number or null |
Read Only | False |
Added | iLO 5 1.40 |
NumericThresholds.UpperCritical NumericThresholds.UpperCritical.Activation Member of Triggers.v1_0_0.Triggers
Description | The direction of crossing that activates this threshold. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Increasing |
Value increases above the threshold. |
Decreasing |
Value decreases below the threshold. |
Either |
Value crosses the threshold in either direction. |
NumericThresholds.UpperCritical.DwellTime Member of Triggers.v1_0_0.Triggers
Description | The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.40 |
NumericThresholds.UpperCritical.Reading Member of Triggers.v1_0_0.Triggers
Description | The threshold value. |
Type | number or null |
Read Only | False |
Added | iLO 5 1.40 |
NumericThresholds.UpperWarning NumericThresholds.UpperWarning.Activation Member of Triggers.v1_0_0.Triggers
Description | The direction of crossing that activates this threshold. |
Type | string |
Read Only | True |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
Increasing |
Value increases above the threshold. |
Decreasing |
Value decreases below the threshold. |
Either |
Value crosses the threshold in either direction. |
NumericThresholds.UpperWarning.DwellTime Member of Triggers.v1_0_0.Triggers
Description | The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.40 |
NumericThresholds.UpperWarning.Reading Member of Triggers.v1_0_0.Triggers
Description | The threshold value. |
Type | number or null |
Read Only | False |
Added | iLO 5 1.40 |
Member of Triggers.v1_0_0.Triggers See the Redfish standard schema and specification for information on common Status object.
Member of Triggers.v1_0_0.Triggers
TriggerActions
is an array containing elements of:
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
LogToLogService |
Upon a trigger, record in a log. |
RedfishEvent |
Upon a trigger, send a Redfish Event message of type MetricReport. |
@odata.type: "#TriggersCollection.TriggersCollection"
A Collection of Triggers resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/triggers |
Link Name | Destination type |
---|---|
Members[] |
Trigger |
Member of TriggersCollection.TriggersCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of TriggersCollection.TriggersCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of TriggersCollection.TriggersCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#UpdateService.v1_1_1.UpdateService"
The UpdateService resource describes the Update Service. It represents the properties for the service itself and has links to collections of firmware and software inventory.
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice |
GET POST PATCH |
Link Name | Destination type |
---|---|
Oem/Hpe/InstallSets |
Collection of HpeComponentInstallSet |
Oem/Hpe/ComponentRepository |
Collection of HpeComponent |
FirmwareInventory |
Collection of SoftwareInventory |
SoftwareInventory |
Collection of SoftwareInventory |
Oem/Hpe/UpdateTaskQueue |
Collection of HpeComponentUpdateTask |
Link to Firmware Inventory.
FirmwareInventory is a link ("@odata.id": URI
) to another resource.
Member of UpdateService.v1_1_1.UpdateService
Description | The URI to which a client may POST an update image. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | uri-reference |
Link to the Component Repository.
ComponentRepository is a link ("@odata.id": URI
) to another resource.
Member of UpdateService.v1_1_1.UpdateService
Description | ISO 8601 Redfish-style time string of the current iLO time (the reference for all scheduling) |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
Member of UpdateService.v1_1_1.UpdateService
Description | Can be used to restrict the firmware downgrade. |
Type | string |
Read Only | False |
Added | iLO 5 1.40 |
The following are the supported values:
Value | Description |
---|---|
AllowDowngrade |
Downgrading firmware is allowed. |
RecoveryDowngrade |
Downgrading firmware is allowed by a user with the Recovery Set privilege. |
NoDowngrade |
Downgrading firmware is not allowed. This is a permanent setting and cannot be undone. |
Oem.Hpe.FirmwareIntegrity.EnableBackgroundScan Member of UpdateService.v1_1_1.UpdateService
Description | Enables or disables background scan of critical firmware. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Oem.Hpe.FirmwareIntegrity.LastFailedImageUri Member of UpdateService.v1_1_1.UpdateService
Description | This is a link to the binary image of the firmware that failed an integrity check and is intended for diagnostic purposes. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Format | uri-reference |
Oem.Hpe.FirmwareIntegrity.LastScanResult Member of UpdateService.v1_1_1.UpdateService
Description | The firmware integrity scan engine status. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
OK |
The last firmware integrity scan completed without finding any issues. |
Repaired |
The last firmware integrity scan successfully repaired an issue. Refer to the event log for details. |
Failure |
The last firmware integrity scan failed to complete or repair an issue. Refer to the event log for details. |
Stopped |
The last firmware integrity scan was stopped prior to completion. Refer to the event log for details. |
Oem.Hpe.FirmwareIntegrity.LastScanTime Member of UpdateService.v1_1_1.UpdateService
Description | The time stamp of the last firmware integrity scan. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Format | date-time |
Oem.Hpe.FirmwareIntegrity.OnIntegrityFailure Member of UpdateService.v1_1_1.UpdateService
Description | Sets the policy for how the firmware integrity check handles integrity failures. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
LogOnly |
Log failures to the iLO event log but do not automatically attempt to repair. |
LogAndRepairAutomatically |
Log failures to the iLO event log and automatically attempt to repair. |
Oem.Hpe.FirmwareIntegrity.ScanEveryDays Member of UpdateService.v1_1_1.UpdateService
Description | Sets the interval between firmware integrity scans in 24 hour increments. |
Type | integer or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of UpdateService.v1_1_1.UpdateService
Description | This is the percent complete for an iLO flash operation. It is only valid when State is Updating. |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Link to the Install Sets collection.
InstallSets is a link ("@odata.id": URI
) to another resource.
Link to the Invalid Image Repository.
InvalidImageRepository is a link ("@odata.id": URI
) to another resource.
Link to the Maintenance Windows.
MaintenanceWindows is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.Result.MessageArgs (array)
Member of UpdateService.v1_1_1.UpdateService
MessageArgs
is an array containing elements of:
Type | string |
Read Only | True |
Oem.Hpe.Result.MessageId Member of UpdateService.v1_1_1.UpdateService
Description | The key for this message that can be used to look up the message in a message registry. |
Type | string |
Read Only | False |
Added | iLO 5 1.10 |
Member of UpdateService.v1_1_1.UpdateService
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Idle |
The update service is idle. |
Uploading |
The update service is receiving a new component. |
Verifying |
The update service is verifying the integrity of a new component. |
Writing |
The update service is writing a new component to the iLO Repository. |
Updating |
The update service is updating (flashing) firmware. |
Complete |
The update service has completed up upload or update operation. |
Error |
The upload service encountered an error. See Result for detail. |
Link to the Update Task Queue.
UpdateTaskQueue is a link ("@odata.id": URI
) to another resource.
Member of UpdateService.v1_1_1.UpdateService
Description | client-supplied etag (during component upload) indicating to what UploadStatus is reporting upon. |
Type | string |
Read Only | True |
Added | iLO 5 1.10 |
Member of UpdateService.v1_1_1.UpdateService
Description | Indicates if the Update Service is enabled. |
Type | boolean or null |
Read Only | True |
Added | iLO 5 1.10 |
Link to Software Inventory. This is only available when the Agentless Management Service is running.
SoftwareInventory is a link ("@odata.id": URI
) to another resource.
UpdateService.SimpleUpdate Member of UpdateService.v1_1_1.UpdateService
Parameters:
TransferProtocol (string)
Value | Description |
---|---|
HTTP | Hypertext Transfer Protocol |
HTTPS | HTTP Secure protocol |
ImageURI (string)
HpeiLOUpdateServiceExt.DeleteInstallSets Member of UpdateService.v1_1_1.UpdateService
Parameters:
IncludeRecoverySet (boolean)
HpeiLOUpdateServiceExt.DeleteUnlockedComponents Member of UpdateService.v1_1_1.UpdateService There are no parameters for this action.
HpeiLOUpdateServiceExt.DeleteMaintenanceWindows Member of UpdateService.v1_1_1.UpdateService There are no parameters for this action.
HpeiLOUpdateServiceExt.AddFromUri Member of UpdateService.v1_1_1.UpdateService
Parameters:
UpdateTarget (boolean)
If true the action will flash the target.
UpdateRecoverySet (boolean)
If true the action will update the system recovery set if it contains a matching target after the repository is updated.
UploadCurrentEtag (string)
client-supplied etag (during component upload) indicating to what UploadStatus is reporting upon.
@odata.type: "#VirtualMedia.v1_2_0.VirtualMedia"
The VirtualMedia resource describes the BMC virtual media feature.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/virtualmedia/{item} |
GET POST PATCH |
Member of VirtualMedia.v1_2_0.VirtualMedia
Description | Specifies how the virtual media is connected to the server. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
NotConnected |
No current connection. |
URI |
Connected to a URI location. |
Applet |
Connected to a client application. |
Member of VirtualMedia.v1_2_0.VirtualMedia
Description | The valid URI indicating the image that is mounted on this server. A null value indicates that no image exists. |
Type | string or null |
Read Only | False |
Added | iLO 5 1.10 |
Format | uri-reference |
Member of VirtualMedia.v1_2_0.VirtualMedia
Description | The name of the image that is mounted on this server. This is usually provided when a URL image is mounted through scripted virtual media. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of VirtualMedia.v1_2_0.VirtualMedia
Description | Indicates whether the virtual media is mounted on the server. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.10 |
Member of VirtualMedia.v1_2_0.VirtualMedia
MediaTypes
is an array containing elements of:
Description | The array of supported media types for this connection. |
Type | string |
Read Only | True |
The following are the supported values:
Value | Description |
---|---|
CD |
A CD-ROM format (ISO) image. |
Floppy |
A floppy disk image. |
USBStick |
An emulation of a USB storage device. |
DVD |
A DVD-ROM format image. |
Member of VirtualMedia.v1_2_0.VirtualMedia
Description | If set to true, the server will boot to this image on the next server reboot. The image will be ejected automatically on the second server reboot so that the server does not boot to this image twice. |
Type | boolean |
Read Only | False |
Added | iLO 5 1.10 |
Member of VirtualMedia.v1_2_0.VirtualMedia
Description | Indicates whether the virtual media is protected against write operations. |
Type | boolean or null |
Read Only | False |
Added | iLO 5 1.10 |
VirtualMedia.InsertMedia Member of VirtualMedia.v1_2_0.VirtualMedia
Parameters:
Image (string)
The URI of the remote media to attach to the virtual media.
WriteProtected (boolean)
Indicates whether the virtual media is protected against write operations. If this parameter is not provided by the client, the service shall default this value to be true.
Inserted (boolean)
Indicates if the image is to be treated as inserted upon completion of the action. If this parameter is not provided by the client, the service shall default this value to be true.
VirtualMedia.EjectMedia Member of VirtualMedia.v1_2_0.VirtualMedia There are no parameters for this action.
HpeiLOVirtualMedia.InsertVirtualMedia Member of VirtualMedia.v1_2_0.VirtualMedia
Parameters:
Certificate (string)
A PEM encoded X509 certificate used to validate the https server.
Image (string)
A URL for an ISO, BIN, or IMG file locating the virtual media image.
Intent (string)
A text description of the reason for this action invocation.
Signature (string)
A RSA2048 SHA-256 signature validating the provided Intent (Base64 encoded).
WriteProtected (boolean)
Indicates whether the virtual media is protected against write operations.
HpeiLOVirtualMedia.EjectVirtualMedia Member of VirtualMedia.v1_2_0.VirtualMedia
Parameters:
Intent (string)
A text description of the reason for this action invocation.
Signature (string)
A RSA2048 SHA-256 signature validating the provided Intent (Base64 encoded).
@odata.type: "#VirtualMediaCollection.VirtualMediaCollection"
A Collection of VirtualMedia resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/virtualmedia |
GET |
Link Name | Destination type |
---|---|
Members[] |
VirtualMedia |
Member of VirtualMediaCollection.VirtualMediaCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of VirtualMediaCollection.VirtualMediaCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of VirtualMediaCollection.VirtualMediaCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
@odata.type: "#Volume.v1_0_0.Volume"
The Volume resource describes a volume, virtual disk, LUN, or other logical storage entity for any system.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/storage/{interface}/{item}/volumes/{item} |
GET |
Link Name | Destination type |
---|---|
Links/Drives[] |
Drive |
Member of Volume.v1_0_0.Volume
Description | The size in bytes of this Volume |
Type | integer or null |
Read Only | True |
Added | iLO 5 1.10 |
Member of Volume.v1_0_0.Volume See the Redfish standard schema and specification for information on common Status object.
Member of Volume.v1_0_0.Volume
Description | The type of this volume. |
Type | string or null |
Read Only | True |
Added | iLO 5 1.10 |
The following are the supported values:
Value | Description |
---|---|
RawDevice |
The volume is a raw physical device without any RAID or other virtualization applied |
@odata.type: "#VolumeCollection.VolumeCollection"
A Collection of Volume resource instances.
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/storage/{interface}/{item}/volumes |
GET |
Link Name | Destination type |
---|---|
Members[] |
Volume |
Member of VolumeCollection.VolumeCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of VolumeCollection.VolumeCollection
Type | string |
Read Only | True |
Format | uri-reference |
Member of VolumeCollection.VolumeCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
While attempting to access, connect to, or transfer to/from another resource, the service was denied access.
Message Format | "While attempting to establish a connection to %1, the service was denied access." |
Severity | Critical |
Resolution | Verify that the URI is correct and that the service has the appropriate credentials. |
The account for the current session is removed, and the current session is also removed.
Message Format | "The account for the current session is removed, and the current session is also removed." |
Severity | OK |
Resolution | Attempt to connect using a valid account. |
The account was modified successfully.
Message Format | "The account was modified successfully." |
Severity | OK |
Resolution | None. |
The request was unable to modify the account.
Message Format | "The account modification request did not complete." |
Severity | Warning |
Resolution | If the operation did not complete, check the authorization or the request body for issues and resubmit the request. |
The account was removed successfully.
Message Format | "The account was removed successfully." |
Severity | OK |
Resolution | None. |
The action supplied in the POST operation is not supported by the resource.
Message Format | "The action %1 is not supported by the resource." |
Severity | Critical |
Resolution | The action was invalid or the wrong resource was the target. See the implementation documentation for assistance. |
The action was submitted with a duplicate parameter in the request body.
Message Format | "The action %1 was submitted with more than one value for the parameter %2." |
Severity | Warning |
Resolution | Resubmit the action with only one instance of the parameter in the request body. |
The requested action is missing a parameter that is required to process the action.
Message Format | "The action %1 requires that the parameter %2 be present in the request body." |
Severity | Critical |
Resolution | Resubmit the action with the required parameter in the request body. |
The action parameter is not supported on the target resource.
Message Format | "The parameter %1 for the action %2 is not supported on the target resource." |
Severity | Warning |
Resolution | If the operation did not complete, remove the parameter and resubmit the request. |
An action was submitted, but a supplied parameter did not match any of the known parameters.
Message Format | "The action %1 was submitted with the invalid parameter %2." |
Severity | Warning |
Resolution | If the operation did not complete, correct the invalid parameter and resubmit the request. |
The value type is correct, but the format is not supported or the size/length is exceeded.
Message Format | "The value %1 for the parameter %2 in the action %3 is in a format that is not supported by the parameter." |
Severity | Warning |
Resolution | If the operation did not complete, correct the parameter value in the request body and resubmit the request. |
The parameter contains an incorrect value type. For example, a number value for a string parameter type.
Message Format | "The value %1 for the parameter %2 in the action %3 is the incorrect parameter type." |
Severity | Warning |
Resolution | If the operation did not complete, correct the parameter value in the request body and resubmit the request. |
An attempt to access the resource, image, or file at the URI was unsuccessful because a session could not be established.
Message Format | "The service was unable to establish a connection with the URI %1." |
Severity | Critical |
Resolution | Verify that the URI contains a valid and reachable node name, protocol information, and other URI components. |
A create operation was attempted on a resource, but a required property was missing from the request.
Message Format | "The create operation did not complete because the required property %1 was missing from the request." |
Severity | Critical |
Resolution | If the operation did not complete, include the required property with a valid value in the request body and resubmit the request. |
Additional resources cannot be created.
Message Format | "Additional resources cannot be created." |
Severity | Critical |
Resolution | If the operation did not complete, delete resources and resubmit the request. |
The resource has been created successfully.
Message Format | "The resource has been created successfully." |
Severity | OK |
Resolution | None |
Indicates that the request body contained an empty JSON object when one or more properties are expected in the body.
Message Format | "The request body submitted contained an empty JSON object and the service is unable to process it." |
Severity | Warning |
Resolution | Add properties in the JSON object and resubmit the request. |
The event subscription establishment has been requested, but the operation did not complete. The number of simultaneous subscriptions exceeded the maximum number allowed by the implementation.
Message Format | "The event subscription did not complete because the number of simultaneous subscriptions exceeded the maximum number allowed by the implementation." |
Severity | Critical |
Resolution | Before attempting to establish the event subscription, reduce the number of subscriptions or increase the maximum number of simultaneous subscriptions allowed (if supported). |
Indicates that a general error has occurred. Use in ExtendedInfo is discouraged. When used in ExtendedInfo, implementations are expected to include a Resolution property with this error to indicate how to resolve the problem.
Message Format | "A general error has occurred. See Resolution for information on how to resolve the error." |
Severity | Critical |
Resolution | None. |
The account or credentials associated with the current session are not authorized to perform the requested operation.
Message Format | "The account or credentials associated with the current session are not authorized to perform the requested operation." |
Severity | Critical |
Resolution | Retry the operation with an authorized account or credentials. |
The request did not complete due to an unknown internal error, but the service is still operational.
Message Format | "The request failed due to an internal service error, but the service is still operational." |
Severity | Critical |
Resolution | Resubmit the request. If the problem persists, consider resetting the service. |
The Index is not valid.
Message Format | "The Index %1 is not a valid offset into the array." |
Severity | Warning |
Resolution | Verify the index value provided is within the bounds of the array. |
The object is not valid.
Message Format | "The object at %1 is not valid." |
Severity | Critical |
Resolution | If the operation did not complete, the object is malformed or the URI is incorrect. Make the appropriate corrections and resubmit the request. |
The request body contains malformed JSON.
Message Format | "The request body submitted is malformed JSON and cannot be parsed by the receiving service." |
Severity | Critical |
Resolution | Verify that the request body is valid JSON and resubmit the request. |
Indicates that the requested operation will not perform any changes on the service.
Message Format | "The request body submitted contain no data to act upon and no changes to the resource took place." |
Severity | Warning |
Resolution | Add properties in the JSON object and resubmit the request. |
The operation did not complete because a valid session is required in order to access resources.
Message Format | "There is no valid session established with the implementation." |
Severity | Critical |
Resolution | Establish a session before attempting any operations. |
A duplicate property is in the request body.
Message Format | "The property %1 is duplicated in the request." |
Severity | Warning |
Resolution | If the operation did not complete, remove the duplicate property from the request body and resubmit the request. |
The request does not include a required property.
Message Format | "The property %1 is a required property and must be included in the request." |
Severity | Warning |
Resolution | If the operation did not complete, verify the property is in the request body and has a valid value. |
The request included a value for a read-only property.
Message Format | "The property %1 is a read-only property and cannot be assigned a value." |
Severity | Warning |
Resolution | If the operation did not complete, remove the property from the request body and resubmit the request. |
An unknown property is in the request body.
Message Format | "The property %1 is not valid for this resource." |
Severity | Warning |
Resolution | If the operation did not complete, remove the unknown property from the request body and resubmit the request. |
The value type is correct, but the format is not supported or the size/length is exceeded.
Message Format | "The value %1 for the property %2 is in a format that is not supported by the property." |
Severity | Warning |
Resolution | If the operation did not complete, correct the property value in the request body and resubmit the request. |
Indicates that a property was given the correct value type but the value of that property was modified. Examples are truncated or rounded values.
Message Format | "The property %1 was assigned the value %2 due to modification by the service." |
Severity | Warning |
Resolution | No resolution is required. |
The value type is correct, but the value is not supported.
Message Format | "The value %1 for the property %2 is not valid." |
Severity | Warning |
Resolution | If the operation did not complete, choose a value from the enumeration list and resubmit your request. |
The property value contains an incorrect property type. For example, a number value for a string property type.
Message Format | "The value %1 for the property %2 is the incorrect property type." |
Severity | Warning |
Resolution | If the operation did not complete, correct the property value in the request body and resubmit the request. |
The query is not supported by the implementation.
Message Format | "Querying is not supported by the implementation." |
Severity | Warning |
Resolution | If the operation did not complete, remove the query parameter and resubmit the request. |
The query is not supported on the resource. For example, a start/count query is attempted on a resource that is not a collection.
Message Format | "Querying is not supported on the requested resource." |
Severity | Warning |
Resolution | If the operation did not complete, remove the query parameters and resubmit the request. |
The query parameter value is out of range for the resource. For example, a page is requested that is outside the valid page range.
Message Format | "The value %1 for the query parameter %2 is out of range %3." |
Severity | Warning |
Resolution | Specify a query parameter value that is within range. For example, a page that is within the valid range of pages. |
The value type is correct, but the format is not supported or the size/length was exceeded.
Message Format | "The value %1 for the parameter %2 is in a format that is not supported by the parameter." |
Severity | Warning |
Resolution | If the operation did not complete, correct the value for the query parameter in the request body and resubmit the request. |
The query parameter contains an incorrect value type. For example, a number supplied for a query parameter that requires a string.
Message Format | "The value %1 for the query parameter %2 is the incorrect type of value for the query parameter." |
Severity | Warning |
Resolution | If the operation did not complete, correct the value for the query parameter in the request body and resubmit the request. |
Indicates that a resource change or creation was attempted but that the operation cannot proceed because the resource already exists.
Message Format | "The requested resource of type %1 with the property %2 with the value %3 already exists." |
Severity | Critical |
Resolution | Do not repeat the create operation as the resource has already been created. |
The URI is valid, but the resource or image at that URI is in a format that is not supported by the service.
Message Format | "The resource at %1 is in a format that is not supported by the service." |
Severity | Critical |
Resolution | Place a resource, image, or file that is supported by the service at the URI. |
An attempt to access the resource, image, or file at the URI is unauthorized.
Message Format | "While accessing the resource at %1, the service received an authorization error %2." |
Severity | Critical |
Resolution | Verify that the appropriate access is provided for the service to access the URI. |
A delete operation was attempted on a resource that cannot be deleted.
Message Format | "The delete request did not complete because the resource cannot be deleted." |
Severity | Critical |
Resolution | Do not attempt to delete a resource that does not support the REST API DELETE operation. |
Indicates that a resource could not satisfy the request due to some unavailability of resources. An example is that available capacity has been allocated.
Message Format | "The resource %1 was unable to satisfy the request due to unavailability of resources." |
Severity | Critical |
Resolution | Ensure that the resources are available and resubmit the request. |
Indicates that the request could not be performed because the resource is in standby.
Message Format | "The request could not be performed because the resource is in standby." |
Severity | Critical |
Resolution | Ensure that the resource is in the correct power state and resubmit the request. |
The request to change the resource was rejected because the resource was in use or in transition.
Message Format | "The change to the resource did not complete because the resource is in use or in transition." |
Severity | Warning |
Resolution | If the operation did not complete, wait until the resource is free and resubmit the request. |
The operation expected an image or resource at the provided URI, but found none.
Message Format | "The resource at the URI %1 was not found." |
Severity | Critical |
Resolution | Place a valid resource at the URI or correct the URI and resubmit the request. |
Indicates that the operation expected a resource identifier that corresponds to an existing resource but one was not found.
Message Format | "The requested resource of type %1 named %2 was not found." |
Severity | Critical |
Resolution | Provide a valid resource identifier and resubmit the request. |
Indicates that the resource type of the operation does not match that for the operation destination. Examples of when this can happen include during a POST to a collection using the wrong resource type, an update where the @odata.types do not match or on a major version incompatability.
Message Format | "The @odata.type of the request body %1 is incompatible with the @odata.type of the resource which is %2." |
Severity | Critical |
Resolution | Resubmit the request with a payload compatible with the resource's schema. |
The operation did not complete because the service is in an unknown state and cannot take incoming requests.
Message Format | "The operation did not complete because the service is in an unknown state and cannot take incoming requests." |
Severity | Critical |
Resolution | If the operation did not complete, restart the service and resubmit the request. |
The operation did not complete because the service is shutting down.
Message Format | "The operation did not complete because the service is shutting down and cannot take incoming requests." |
Severity | Critical |
Resolution | If the operation did not complete, resubmit the request when the service is available. |
The service is temporarily unavailable.
Message Format | "The service is temporarily unavailable. Retry in %1 seconds." |
Severity | Critical |
Resolution | Wait for the indicated retry duration and retry the operation. |
Session establishment has been requested, but the operation did not complete because the number of simultaneous sessions exceeded the maximum number allowed by the implementation.
Message Format | "The session establishment did not complete because the number of simultaneous sessions exceeded the maximum number allowed by the implementation." |
Severity | Critical |
Resolution | Before attempting to establish the session, reduce the number of sessions or increase the maximum number of simultaneous sessions allowed (if supported). |
Indicates that the DELETE operation on the Session resource resulted in the successful termination of the session.
Message Format | "The session was successfully terminated." |
Severity | OK |
Resolution | No resolution is required. |
While attempting to access, connect to, or transfer from another location, the other end of the connection did not support the specified protocol.
Message Format | "The other end of the connection at %1 does not support the specified protocol %2." |
Severity | Critical |
Resolution | Change protocols or URIs. |
Indicates that a string value passed to the given resource exceeded its length limit. An example is when a shorter limit is imposed by an implementation than that allowed by the specification.
Message Format | "The string %1 exceeds the length limit %2." |
Severity | Warning |
Resolution | Resubmit the request with an appropriate string length. |
The operation completed successfully.
Message Format | "The operation completed successfully." |
Severity | OK |
Resolution | None |
The service detected a request body with malformed JSON.
Message Format | "The service detected a request body with malformed JSON." |
Severity | Warning |
Resolution | If the operation did not complete, correct the request body and resubmit the request. |
The items in the array exceed the maximum number supported.
Message Format | "An array %1 was supplied with %2 items that exceeds the maximum supported count of %3." |
Severity | Warning |
Resolution | Retry the operation using the correct number of items for the array. |
A property value was successfully changed but the change may be reverted upon system reset.
Message Format | "The property %1 was successfully changed to %2, but the change may be reverted upon system reset." |
Severity | Warning |
Resolution | Check the "SettingsResult" messages after the system has reset for errors referring to the corresponding property. |
The operation was not successful due to an internal service error (shown), but the service is still operational.
Message Format | "The operation was not successful due to an internal service error (%1), but the service is still operational." |
Severity | Critical |
Resolution | Retry the operation. If the problem persists, consider resetting the service. |
The specified configuration is not valid.
Message Format | "The specified configuration is not valid." |
Severity | Warning |
Resolution | Correct the configuration, and then retry the operation. |
The value for the property exceeds the maximum length.
Message Format | "The value %1 for the property %2 exceeds the maximum length of %3." |
Severity | Warning |
Resolution | Correct the value for the property in the request body, and then retry the operation. |
The value for the property is the correct type, but this value is incompatible with the current value of another property.
Message Format | "The value %1 for the property %2 is incompatible with the value for property %3." |
Severity | Warning |
Resolution | Correct the value for the property in the request body, and then retry the operation. |
The value for the property is out of range.
Message Format | "The value %1 for the property %2 is out of range %3." |
Severity | Warning |
Resolution | Correct the value for the property in the request body, and then retry the operation. |
A device or service reset is in progress.
Message Format | "A reset on %1 is in progress." |
Severity | Warning |
Resolution | Wait for device or service reset to complete, and then retry the operation. |
One or more properties were changed, but these changes will not take effect until the device or service is reset.
Message Format | "One or more properties were changed, but these changes will not take effect until %1 is reset." |
Severity | Warning |
Resolution | To enable the changed properties, reset the device or service. |
The resource is present but is not ready to perform operations due to an internal condition such as initialization or reset.
Message Format | "The resource is present but is not ready to perform operations. The resource will be ready in %1 seconds." |
Severity | Warning |
Resolution | Retry the operation when the resource is ready. |
The operation completed successfully
Message Format | "The operation completed successfully" |
Severity | OK |
Resolution | None |
A task was created in response to the operation.
Message Format | "A task was created in response to the operation and is accessible at %1." |
Severity | OK |
Resolution | Perform an HTTP GET request on the supplied URI for task status. |
A previously requested property value change was reverted because the current hardware configuration does not support it.
Message Format | "The value %1 for property %2 was reverted because the current hardware configuration does not support it." |
Severity | Warning |
Resolution | Ensure that the system's hardware configuration supports the property value. |
Modifying AHS properties is not possible with AHS disabled.
Message Format | "Modifying AHS properties is not possible with AHS disabled." |
Severity | Warning |
Resolution | Enable AHS, and then modify the AHS properties. |
Indicates that one or more properties were correctly changed, but may not be in effect yet.
Message Format | "Indicates that one or more properties were correctly changed, but may not be in effect yet." |
Severity | OK |
Resolution | None |
Indicates that the correct value type was supplied for the action parameter, but the value is not supported. (The value is not in the enumeration list.)
Message Format | "The value %1 for the property %2 is not in the list of valid values." |
Severity | Warning |
Resolution | Choose a value from the enumeration list and resubmit the request if the operation failed. |
AlertDestination cannot be configured with both SNMPv1 and SNMPv3.
Message Format | "AlertDestination cannot be configured with both SNMPv1 and SNMPv3." |
Severity | Warning |
Resolution | For SNMPv1 alert, configure SNMPAlertProtocol to SNMPv1. For SNMPv3 alert, configure SNMPAlertProtocol to SNMPv3. |
AlertMail feature is disabled.
Message Format | "AlertMail feature is disabled." |
Severity | Warning |
Resolution | Enable AlertMail feature to send test alert message. |
An operation is already in progress.
Message Format | "An operation is already in progress." |
Severity | Warning |
Resolution | Wait for the current operation to complete, and then retry the operation. |
The update did not occur because the component was already up to date.
Message Format | "The update did not occur because the component was already up to date." |
Severity | Warning |
Resolution | None. |
Operation is currently unavailable because the power regulator is set to APM Power Capping Mode.
Message Format | "Operation is currently unavailable because the power regulator is set to APM Power Capping Mode." |
Severity | Warning |
Resolution | Change the power regulator to other modes rather than APM Power Capping Mode through APM interface. |
Duplicate value.
Message Format | "The property value %1 is already exists in index %2" |
Severity | Warning |
Resolution | If the operation did not complete, correct the property value in the request body and resubmit the request. |
The number of items in the array exceeds the maximum number supported.
Message Format | "An array %1 was supplied with %2 items that does not meet the minimum supported count of %3 or exceeds the maximum supported count of %4." |
Severity | Warning |
Resolution | Retry the operation using the correct number of items for the array. |
The property value is not valid.
Message Format | "The property value %1 in index %2 is not valid." |
Severity | Warning |
Resolution | Retry the operation using a corrected value. |
Battery Backup Unit settings are currently disabled.
Message Format | "Battery Backup Unit settings are disabled when the system is configured for Scalable Persistent Memory." |
Severity | Warning |
Resolution | To re-enable Battery Backup Unit settings, disable Scalable Persistent Memory functionality in the system ROM RBSU. |
The BIOS action supplied in the POST operation is not yet implemented.
Message Format | "The BIOS action %1 is not implemented yet." |
Severity | Critical |
Resolution | The action was invalid or the wrong resource was the target. See the implementation documentation for assistance. |
The stored BIOS password information is invalid. A system reboot is neccessary to retore password defaults.
Message Format | "The stored BIOS password information is invalid. Reboot system." |
Severity | Critical |
Resolution | The system will need to be rebooted to restore BIOS password information to defaults. |
The provided OldPassword does not match the stored BIOS password.
Message Format | "The provided OldPassword does not match the stored BIOS password." |
Severity | Critical |
Resolution | Retry the action with the matching password. |
Power calibrate is in progress.
Message Format | "Power calibrate is in progress." |
Severity | Warning |
Resolution | Wait for previous power calibrate complete or stop previous power calibrate, and then retry the operation. |
Cannot remove default language pack.
Message Format | "Cannot remove default language pack." |
Severity | Warning |
Resolution | None. |
Cannot remove language pack.
Message Format | "Cannot remove %1 language pack." |
Severity | Warning |
Resolution | None. |
Cannot remove the base license.
Message Format | "The base license cannot be removed." |
Severity | Warning |
Resolution | None. |
Chassis power regulation data is currently unavailable.
Message Format | "Chassis power regulation data is currently unavailable." |
Severity | Warning |
Resolution | Reset the management processor or chassis manager, and then retry the operation. |
The chassis properties were correctly changed, but will not take effect until the chassis is reset or all nodes in chassis remain powered off for at least 5 seconds.
Message Format | "One or more properties were changed and will not take effect until chassis is reset or all nodes in chassis remain powered off for at least 5 seconds." |
Severity | Warning |
Resolution | Reset chassis or remain power off for all nodes in chassis for at least 5 seconds for the settings to take effect. |
A component upload operation is already in progress.
Message Format | "A component upload operation is already in progress." |
Severity | Warning |
Resolution | Wait for the current component upload to complete, and then retry the operation. |
A component upload operation failed.
Message Format | "A component upload operation failed." |
Severity | Warning |
Resolution | Wait for the current component upload to complete, and then retry the operation. |
An update operation failed due to exceeding a daily limit.
Message Format | "An update operation failed due to exceeding a daily limit." |
Severity | Warning |
Resolution | Retry the operation at a later date. |
A license was previously activated and now a demo key may not be used.
Message Format | "A license was previously activated." |
Severity | Warning |
Resolution | The system is no longer eligible for demo licenses. |
Device was not available for communication.
Message Format | "Device communication response was busy." |
Severity | Warning |
Resolution | Retry the attempted operation after a delay. |
Indicates that one or more properties were correctly changed, but will not take effect until device is reset.
Message Format | "One or more properties were changed and will not take effect until the device is reset." |
Severity | Warning |
Resolution | Reset the device for the settings to take effect. |
A diagnostics self test is already running.
Message Format | "A diagnostics self test is already running." |
Severity | Warning |
Resolution | Stop the running test and try again. |
The task did not execute because a downgrade is not allowed by policy.
Message Format | "The task did not execute because a downgrade is not allowed by policy." |
Severity | Warning |
Resolution | Obtain the latest available component and retry, and clear the task from the queue so processing can continue. |
The downgrade policy has been set and cannot be changed.
Message Format | "The downgrade policy has been set and cannot be changed." |
Severity | Warning |
Resolution | None. |
Enterprise Secure Key Manager Servers are not configured.
Message Format | "Enterprise Secure Key Manager Servers are not configured." |
Severity | OK |
Resolution | None. |
The supplied ETag is too long. The maximum supported ETag length is 63 bytes.
Message Format | "The supplied ETag is too long. The maximum supported ETag length is 63 bytes." |
Severity | Warning |
Resolution | Retry the operation using an ETag with a length of 63 bytes or less. |
DNS name is empty.
Message Format | "Empty DNS name." |
Severity | Warning |
Resolution | Retry the request with a valid DNS name. |
Failed to initialize ESKM.
Message Format | "Failed to initialize ESKM." |
Severity | Warning |
Resolution | Check if Account Group, Local CA Certificate Name, Login Name and Password are correct and try again. |
Event log cleared successfully.
Message Format | "Event log cleared successfully." |
Severity | OK |
Resolution | None. |
The event subscription was modified successfully.
Message Format | "The event subscription was modified successfully." |
Severity | OK |
Resolution | None. |
The event subscription was removed successfully.
Message Format | "The event subscription was removed successfully." |
Severity | OK |
Resolution | None. |
Indicates that extended information is available.
Message Format | "See @Message.ExtendedInfo for more information." |
Severity | OK |
Resolution | See @Message.ExtendedInfo for more information. |
A Trusted Module is detected in this system. If you have not performed the proper OS encryption procedures, you will lose access to your data if recovery key is not available. Recommended procedure is to suspend encryption software prior to System ROM or Option ROM firmware flash. TPMOverrideFlag is enabled and firmware flash initiated.
Message Format | "CAUTION: A Trusted Module is detected in this system. Updating the System ROM or Option Card Firmware may have impact to measurements stored in the TM and may have impact to security functionality on the platform which depends on these measurements." |
Severity | OK |
Resolution | None. |
A Trusted Module (type unspecified) is installed in the system and TPMOverrideFlag is enabled. Firmware flash initiated.
Message Format | "CAUTION: A Trusted Module (type unspecified) has been detected in this system. If you have not performed the proper OS encryption procedures, you will lose access to your data if recovery key is not available. Recommended procedure for Microsoft Windows(R) BitLocker(TM) is to "suspend" BitLocker prior to System ROM or Option ROM firmware flash." |
Severity | OK |
Resolution | None. |
A Trusted Module is detected in this system. Failure to perform proper OS encryption procedures will result in loss of access to your data if recovery key is not available. Recommended procedure is to suspend encryption software prior to System ROM or Option ROM firmware flash. If you do not have your recovery key or have not suspended encryption software, cancel this firmware upload. Failure to follow these instructions will result in loss of access to your data. To continue with firmware flash TPMOverrideFlag is required.
Message Format | "CAUTION: A Trusted Module is detected in this system. Updating the System ROM or Option Card Firmware may have impact to measurements stored in the TM and may have impact to security functionality on the platform which depends on these measurements." |
Severity | Warning |
Resolution | Please set the TPMOverrideFlag to true and try again. |
A Trusted Module (type unspecified) is installed in the system, TPMOverrideFlag is required for firmware flash to proceed.
Message Format | "CAUTION: A Trusted Module (type unspecified) has been detected in this system. Failure to perform proper OS encryption procedures will result in loss of access to your data if recovery key is not available. Recommended procedure for Microsoft Windows(R) BitLocker(TM) is to "suspend" BitLocker prior to System ROM or Option ROM firmware flash. If you do not have your recovery key or have not suspended BitLocker, exit this flash: Failure to follow these instructions will result in loss of access to your data." |
Severity | Warning |
Resolution | Please set the TPMOverrideFlag to true and try again. |
A firmware upgrade operation is already in progress.
Message Format | "A firmware flash operation is already in progress." |
Severity | Warning |
Resolution | Wait for the current firmware flash to complete, and then retry the operation. |
Generating the X509 Certificate.
Message Format | "X509 Certificate is being generated and the process might take up to 10 minutes." |
Severity | OK |
Resolution | None. |
Backup hard drive zoning configuration to BMC has encountered an error.
Message Format | "Backup hard drive zoning configuration to BMC has encountered an error." |
Severity | Warning |
Resolution | Retry the operation. If the problem persists, consider resetting the BMC or the entire chassis. |
Hard Drive Zoning was in error state.
Message Format | "Hard Drive Zoning was in error state due to %1." |
Severity | Critical |
Resolution | Retry the operation. If the problem persists, consider resetting the entire chassis. |
ICRU returned invalid address for translation.
Message Format | "ICRU returned invalid address for translation." |
Severity | Warning |
Resolution | Input valid address for translation. |
ICRU feature or function is not supported on the system.
Message Format | "ICRU feature or function is not supported on the system." |
Severity | Warning |
Resolution | None. |
The specified IPv6 configuration caused an error.
Message Format | "The specified IPv6 configuration was in error due to %1." |
Severity | Warning |
Resolution | Resolve the indicated error in the configuration data. |
Import Certificate was successful.
Message Format | "Import Certificate was successful." |
Severity | OK |
Resolution | None. |
Import Certificate was successful and the management processor is being reset.
Message Format | "Import Certificate was successful. Management Processor reset is in progress to enable the new certificate." |
Severity | Warning |
Resolution | None. |
Failed importing Certificate.
Message Format | "Failed importing the X509 Certificate." |
Severity | Warning |
Resolution | Retry the operation with proper Certificate information. |
Not a valid parameter.
Message Format | "Invalid Parameter." |
Severity | Warning |
Resolution | Retry the request with valid parameters. |
Not a valid Uri to import SSO certificate.
Message Format | "Invalid Uri." |
Severity | Warning |
Resolution | Retry the request with valid URI. |
The request to change the state of the Indicator LED cannot be granted because the current state is either Blinking or is Unknown.
Message Format | "The Indicator LED cannot be changed when its state is Blinking or Unknown." |
Severity | Warning |
Resolution | Please wait until the server has completed its reserved state. |
The InstallSet write failed.
Message Format | "The InstallSet write of %1 failed." |
Severity | Warning |
Resolution | Ensure a valid name for the item and that space exists to hold the item. |
Disabling one or more interfaces/features will cause certain functionalities to be not available. Please refer to User Guide for details on the implications. Changes will not take effect until the management processor is reset
Message Format | "CAUTION: Disabling one or more interfaces/features will cause certain functionalities to be not available. Please refer to User Guide for details on the implications. Changes will not take effect until the management processor is reset" |
Severity | OK |
Resolution | None. |
The operation was not successful due to an internal service error (shown), but the service is still operational.
Message Format | "The operation was not successful due to an internal service error (%1), but the service is still operational." |
Severity | Critical |
Resolution | Retry the operation. If the problem persists, consider resetting the service. |
The specified configuration is not valid.
Message Format | "The specified configuration is not valid." |
Severity | Warning |
Resolution | Correct the configuration, and then retry the operation. |
iLO Federation Management cannot be supported in the current configuration.
Message Format | "iLO Federation Management cannot be supported in the current configuration." |
Severity | Warning |
Resolution | Review the management processor network settings or Onboard Administrator settings and refer to the User Guide. |
The dwell time specified is not valid.
Message Format | "The dwell time %1 is not valid." |
Severity | Warning |
Resolution | Adhere to the dwell time supported. |
EngineID should be a hexadecimal number starting with 0x (for example, 0x0102030405abcdef). The string length should be an even number, greater than or equal to 6 characters (excluding the "0x"), and less than or equal to 32 characters.
Message Format | "EngineID should be a hexadecimal number starting with 0x (for example, 0x0102030405abcdef). The string length should be an even number, greater than or equal to 6 characters (excluding the "0x"), and less than or equal to 32 characters." |
Severity | Warning |
Resolution | Retry the operation using an EngineID within the specified parameters. |
The license key is not valid.
Message Format | "The license key is not valid." |
Severity | Warning |
Resolution | Retry the operation using a valid license key. |
The operation was not successful because the current auto power on mode specifies power is to remain off.
Message Format | "The auto power on delay cannot be set because power is configured to remain off." |
Severity | Warning |
Resolution | Verify that the system auto power on mode is set to turn power on or follow the previous power setting. |
The operation was not successful due to the current power state (for example, attempting to turn the power off when it is already off).
Message Format | "The operation was not successful due to the current power state." |
Severity | Warning |
Resolution | Verify that the system is in the correct power state, and then retry the operation. |
The passphrase length is not valid.
Message Format | "%1 must contain from %2 to %3 characters." |
Severity | Warning |
Resolution | Correct the passphrase, and then retry the operation. |
The password failed the complexity enforcement.
Message Format | "A valid password must contain three of the following: uppercase, lowercase, numerals, and other." |
Severity | Critical |
Resolution | Retry the operation using a corrected password. |
The password length is not valid.
Message Format | "A valid password must contain between %1 to %2 characters." |
Severity | Critical |
Resolution | Retry the operation using a corrected password. |
The serial number length is not valid.
Message Format | "A valid serial number must be %1 characters of length." |
Severity | Critical |
Resolution | Adjust the length of the serial number and retry the operation. |
The license key activation was refused. Includes details.
Message Format | "The license activation key cannot be installed. %1" |
Severity | Warning |
Resolution | Address the condition or use a valid license activation key. |
The license key supplied is unsupported on this system. The key may activate a different product or unsupported tier.
Message Format | "The supplied license key is not supported on this system." |
Severity | Warning |
Resolution | None. |
A license key is required to use this operation or feature.
Message Format | "A license key is required to use this operation or feature." |
Severity | Warning |
Resolution | Install a license key to use this feature. |
The login was not successful, so the service enforces a delay before another login is allowed.
Message Format | "The login was not successful, so the service enforces a delay before another login is allowed." |
Severity | Warning |
Resolution | Wait for the delay time to expire, and then retry the login. |
The login was not successful, so the service enforces a delay before another login is allowed.
Message Format | "The login was not successful, so the service enforces a %1 second delay before another login is allowed." |
Severity | Warning |
Resolution | None. |
Telemetry service and Workload Performance advisor will be not available with MCTP discovery disabled.
Message Format | "Telemetry service and Workload Performance advisor will be not available with MCTP discovery disabled." |
Severity | Warning |
Resolution | Enable MCTP discovery for Telemetry service and Workload Performance advisor. |
The maximum number of providers are already registered.
Message Format | "The maximum number of providers are already registered." |
Severity | Warning |
Resolution | None. |
No more Virtual Media connections are available, because the maximum number of connections are already established.
Message Format | "No more Virtual Media connections are available, because the maximum number of connections are already established." |
Severity | Warning |
Resolution | Close an established Virtual Media connection, and then retry creating or opening another connection. |
Membist variables are not supported on the system.
Message Format | "Membist variables are not supported on the system." |
Severity | Warning |
Resolution | None. |
The memory set specified in InterleaveSets is not supported.
Message Format | "The memory set specified in InterleaveSets is not supported." |
Severity | Warning |
Resolution | Ensure the memory set specified in InterleaveSets matches the first set in the memory domain's InterleavableMemrorySets. |
Update does not meet minimum version requirements.
Message Format | "Update does not meet minimum version requirements." |
Severity | Warning |
Resolution | Use newer version. |
The requested resource exists but has no content.
Message Format | "The resource exists but has no content." |
Severity | OK |
Resolution | None |
There are no event subscriptions registered.
Message Format | "The operation cannot be completed because there are no event subscribers." |
Severity | Warning |
Resolution |
No support for power metering available on platform.
Message Format | "No support for power metering available on platform." |
Severity | OK |
Resolution | Enable Power Metering on platform if supported. |
No SNMP alert destinations configured or none of the configured destinations are associated with SNMPv1 protocol or SNMPv3 protocol and user.
Message Format | "No SNMP alert destinations configured or none of the configured destinations are associated with SNMPv1 protocol or SNMPv3 protocol and user." |
Severity | Warning |
Resolution | Configure at least one SNMP alert destination and associate it with SNMPv1 protocol or SNMPv3 protocol and user. |
No power history samples are available.
Message Format | "No power history samples are available." |
Severity | OK |
Resolution | To accumulate power history samples, power on the server, and then wait at least 5 minutes. |
No scripted virtual media connections exist to perform the operation.
Message Format | "No scripted virtual media connections exist to perform the operation." |
Severity | Warning |
Resolution | Create or open a scripted virtual media connection, and then retry the operation. |
No space to store DNS name.
Message Format | "No space to store DNS name." |
Severity | Warning |
Resolution | Make sure SSO database has enough space to store DNS name. |
No Virtual Media connections exist to perform the operation.
Message Format | "No Virtual Media connections exist to perform the operation." |
Severity | Warning |
Resolution | Create or open a Virtual Media connection, and then retry the operation. |
Each zone can only manage the node in the same region, cannot manage overlap region.
Message Format | "Each zone can only manage the node for range %1 or range %2, cannot manage overlap region." |
Severity | Warning |
Resolution | Correct the out of range value, and then retry the operation. |
Operation is currently unavailable because there is no node installed in the zone.
Message Format | "Operation is currently unavailable because there is no node installed in the zone." |
Severity | Warning |
Resolution | Install at least one node in the zone and retry the operation. |
This property is not supported by the indicated network port.
Message Format | "%1 is not supported on the %2 Network Port." |
Severity | Warning |
Resolution | Do not specify this property on the indicated network port. |
The value for the property is not a valid IPv4/v6 address or DNS name.
Message Format | "The value for property %1 is not a valid IPv4/v6 address or DNS name." |
Severity | Warning |
Resolution | Correct the IPv4/v6 address or DNS name, and then retry the operation. |
The value for the property is not a valid IP address.
Message Format | "The value %1 is not a valid IP address for %2" |
Severity | Warning |
Resolution | Use a valid IP address. |
The value for the property is not a valid subnet mask.
Message Format | "The value %1 is not a valid subnet mask for %2" |
Severity | Warning |
Resolution | Use a valid subnet mask. |
The value for the property can not be set until System BIOS POST completes.
Message Format | "Property %1 will be settable after the System BIOS completes POST." |
Severity | Warning |
Resolution | Wait to see the change in value until after the System BIOS completes POST. |
The value for the property will be applied after System BIOS POST completes.
Message Format | "The value for property %1 will be changed after the System BIOS completes POST." |
Severity | OK |
Resolution | Wait to see the change in value until after the System BIOS completes POST. |
The enclosure Onboard Administrator is currently managing the power cap.
Message Format | "The enclosure Onboard Administrator is currently managing the power cap." |
Severity | Warning |
Resolution | Use Onboard Administrator to Manage the PowerCap |
The System ROM is currently managing the power cap.
Message Format | "The System ROM is currently managing the power cap." |
Severity | Warning |
Resolution | Enable RESTful API management of the power cap in System ROM |
One of power limit setpoint may become unreachable due to power limit range is unknown. It's not recommended configure power limit setpoint when power limit range is unknown.
Message Format | "One of power limit setpoint may become unreachable due to power limit range is unknown. It's not recommended configure power limit setpoint when power limit range is unknown." |
Severity | Warning |
Resolution | Please execute calibrate action to get power limit range then reconfigure power limit setpoint. |
Operation is currently unavailable because chassis power regulation is enabled.
Message Format | "Operation is currently unavailable because chassis power regulation is enabled." |
Severity | Warning |
Resolution | Disable chassis power regulation, and then retry the operation. |
Indicates that one or more power limit setting were correctly changed, but will not take effect until power regulation enable and power regulator mode switch to user configurable mode.
Message Format | "Indicates that one or more power limit setting were correctly changed, but will not take effect until power regulation enable and power regulator mode switch to user configurable mode." |
Severity | Warning |
Resolution | Enable power regulation and switch power regulator mode to user configurable mode for the settings to take effect. |
The power cap value is not valid.
Message Format | "The power cap value is not valid." |
Severity | Warning |
Resolution | Retry the operation using a corrected value. |
The request to set the power cap failed. Invalid power cap calibration data. The Power Cap feature is currently unavailable.
Message Format | "The request to set the power cap failed. Invalid power cap calibration data. The Power Cap feature is currently unavailable" |
Severity | Warning |
Resolution | Restart the server to retrieve calibration data from initial POST. |
Power caps set below the specified percentage threshold might become unreachable due to changes in the server. It is recommended to not set a cap for less than this threshold.
Message Format | "Power caps set below the specified percentage threshold might become unreachable due to changes in the server. It is recommended to not set a cap for less than %1." |
Severity | Warning |
Resolution | Please provide an optimal value in integer considering the power cap range. |
Advanced power capping is not currently available due to the system configuration or state.
Message Format | "Advanced power capping is not currently available due to the system configuration or state." |
Severity | Warning |
Resolution | Change the system configuration or wait for the system to become fully initialized, and then retry the operation. |
Advanced power capping is not supported on this system.
Message Format | "Advanced power capping is not supported on this system." |
Severity | Warning |
Resolution | None. |
Only the primary ESKM server is accessible.
Message Format | "No redundancy. Only the primary ESKM server is accessible." |
Severity | OK |
Resolution | None. |
Primary and secondary ESKM server addresses resolve to the same server.
Message Format | "No redundancy. Primary and secondary ESKM server addresses resolve to the same server." |
Severity | OK |
Resolution | None. |
Both primary and secondary ESKM servers are accessible.
Message Format | "Redundant solution: Both primary and secondary ESKM servers are accessible." |
Severity | OK |
Resolution | None. |
The property is not supported.
Message Format | "The property %1 is not supported." |
Severity | Warning |
Resolution | Do not attempt to modify this property. |
The request included a value for a read-only or unknown property.
Message Format | "The property %1 is a read-only property and cannot be assigned a value, or not valid for this resource." |
Severity | Warning |
Resolution | If the operation did not complete, remove the property from the request body and resubmit the request. |
The property value is not valid.
Message Format | "The property value is not valid." |
Severity | Warning |
Resolution | Retry the operation using a corrected value. |
The value for the property exceeds the maximum length.
Message Format | "The value %1 for the property %2 exceeds the maximum length of %3." |
Severity | Warning |
Resolution | Correct the value for the property in the request body, and then retry the operation. |
The value for the property is the correct type, but this value is incompatible with the current value of another property.
Message Format | "The value %1 for the property %2 is incompatible with the value for property %3." |
Severity | Warning |
Resolution | Correct the value for the property in the request body, and then retry the operation. |
The value for the property is out of range.
Message Format | "The value %1 for the property %2 is out of range %3." |
Severity | Warning |
Resolution | Correct the value for the property in the request body, and then retry the operation. |
Indicates that a property was required but not specified.
Message Format | "%1 requires Property %2 to be specified." |
Severity | Warning |
Resolution | Include the required property in the request body and then retry the operation. |
A recovery install set is required for this action.
Message Format | "No recovery install set present." |
Severity | Critical |
Resolution | Create a recovery install set (install set with IsRecovery property set true). |
IML event with this severity is not supported to be repaired. IML events with Critical or Warning severities can marked as repaired.
Message Format | "IML event with %1 severity is not supported to be repaired. IML events with Critical or Warning severities can marked as repaired." |
Severity | Warning |
Resolution | Please do not try to repair IML events with severity other than Critical or Warning. |
Indicates that a required property is not specified.
Message Format | "Required Property %1 needs to be specifed." |
Severity | Warning |
Resolution | Include the required property in the request body and then retry the operation. |
A management processor reset is in progress.
Message Format | "A management processor reset is in progress." |
Severity | Warning |
Resolution | Wait for management processor reset to complete, and then retry the operation. |
One or more properties were changed, but these changes will not take effect until the management processor is reset.
Message Format | "One or more properties were changed, but these changes will not take effect until the management processor is reset." |
Severity | Warning |
Resolution | To enable the changed properties, reset the management processor. |
The change to the requested resource failed because the resource is being flashed.
Message Format | "The change to the requested resource failed because the resource is being flashed." |
Severity | Warning |
Resolution | Retry the operation when the firmware upgrade has completed. |
The change could not be made because the resource was in use or in a transitioning state.
Message Format | "The change to the resource failed because the resource is in use or in transition." |
Severity | Warning |
Resolution | Retry the request. |
The resource is present but is not ready to perform operations due to an internal condition such as initialization or reset.
Message Format | "The resource is present but is not ready to perform operations. The resource will be ready in %1 seconds." |
Severity | Warning |
Resolution | Retry the operation when the resource is ready. |
The resource is temporarily unavailable because the firmware is being flashed.
Message Format | "The resource is temporarily unavailable because the firmware is being flashed." |
Severity | Warning |
Resolution | Retry the operation when the firmware upgrade has completed. |
The SMBIOS record type is not found or is not supported on the system.
Message Format | "The SMBIOS record type %1 is not found or is not supported on the system." |
Severity | Warning |
Resolution | Reset the system to update the SMBIOS records. If the problem persists then the SMBIOS record type is not supported. |
The operation could not be completed because SNMP alerts are disabled.
Message Format | "The operation could not be completed because SNMP alerts are disabled." |
Severity | Warning |
Resolution | Enable SNMP alerts and retry the operation. |
Modifying SNMP properties is not possible with SNMP disabled.
Message Format | "Modifying SNMP properties is not possible with SNMP disabled." |
Severity | Warning |
Resolution | Enable SNMP, and then modify the SNMP properties. |
The SNMP Test Alert did not send successfully.
Message Format | "The SNMP Test Alert did not send successfully." |
Severity | Warning |
Resolution | Verify the test alert content and retry. |
SNTP configuration is currently managed by DHCP and is therefore read-only.
Message Format | "%1 cannot be changed while DHCP is configured to provide SNTP settings." |
Severity | Warning |
Resolution | Disable SNTP configuration options in both DHCPv4 and DHCPv6 (see /Managers/n/NICs), and then reconfigure SNTP as desired with static settings. |
SSO Certificate is Empty.
Message Format | "Empty SSO Certificate." |
Severity | Warning |
Resolution | None. |
SSO Certificate Read Error.
Message Format | "Error reading SSO certificate." |
Severity | Warning |
Resolution | Retry the request with valid SSO certificate. |
No space to store SSO certificate.
Message Format | "No space to store SSO certificate." |
Severity | Warning |
Resolution | Make sure SSO database has enough space to store SSO certificate. |
SSO Record Not Found.
Message Format | "SSO Record Not Found." |
Severity | Warning |
Resolution | None. |
Samples are not captured for %1 duration.
Message Format | "Samples for metrics are not captured for %1 duration." |
Severity | OK |
Resolution | Wait for the current duration to complete, and then retry. |
Only the secondary ESKM server is accessible.
Message Format | "No redundancy. Only the secondary ESKM server is accessible." |
Severity | OK |
Resolution | None. |
The current status of Server Configuration Lock is unknown.
Message Format | "The current status of Server Configuration Lock is unknown." |
Severity | Warning |
Resolution | Ensure if the BIOS firmware supports Server Configuration Lock. If supported, reboot the server and retry the operation |
Server Configuration Lock is enabled.
Message Format | "Server Configuration Lock is enabled." |
Severity | Warning |
Resolution | Disable Server Configuration Lock to initiate secure erase of the system |
The operation completed successfully.
Message Format | "The operation completed successfully." |
Severity | OK |
Resolution | None |
Remote Syslog feature is disabled.
Message Format | "Remote syslog feature is disabled." |
Severity | Warning |
Resolution | Enable remote syslog feature to send test syslog message. |
To perform this operation, power off the system. AutoPowerOn must be set to achieve a power restore.
Message Format | "To perform this operation, power off the system." |
Severity | OK |
Resolution | To perform this operation, power off the system. |
System power state change failed (for example, attempting to turn the system power On/Off failed)
Message Format | "System power state change failed" |
Severity | Warning |
Resolution | Retry the request. |
The system properties were correctly changed, but will not take effect until the system is reset.
Message Format | "One or more properties were changed and will not take effect until system is reset." |
Severity | Warning |
Resolution | Reset system for the settings to take effect. |
Proper 'X-HPRESTFULAPI-AuthToken' authorization token not provided.
Message Format | "Proper 'X-HPRESTFULAPI-AuthToken' authorization token not provided." |
Severity | Critical |
Resolution | Create proper 'X-HPRESTFULAPI-AuthToken' authorization token. Send token in using the proper HTTP header. |
Unable to modify user rights.
Message Format | "Unable to modify user rights." |
Severity | Warning |
Resolution | None. |
The value for the property cannot be changed after virual media image is inserted.
Message Format | "The value for property %1 cannot be changed after virual media image is inserted." |
Severity | Warning |
Resolution | Retry the operation during virtual media image inseration. |
The value for the property cannot be changed because a related hardware component is not installed.
Message Format | "The value for property %1 cannot be changed because a related hardware component is not installed." |
Severity | Warning |
Resolution | Install the hardware component and retry the operation. |
The value for the property cannot be changed while the computer system BIOS is in POST.
Message Format | "The value for property %1 cannot be changed while the computer system BIOS is in POST." |
Severity | Warning |
Resolution | After the computer system is either fully booted or powered off, retry the operation. |
The login was not successful, because the supplied credentials could not be authorized.
Message Format | "The login was not successful, because the supplied credentials could not be authorized." |
Severity | Warning |
Resolution | Log in with authorized user name and password credentials. |
Incompatible Cipher Algorithm in FIPS or CNSA Mode.
Message Format | "Incompatible Cipher Algorithm %1 in %2 Mode." |
Severity | Warning |
Resolution | Select compatible Cipher Algorithm. |
This operation is not supported by RIS for the current system.
Message Format | "This operation is not supported by RIS for the current system." |
Severity | Warning |
Resolution | None. |
This operation is not supported by the current version of the XL Chassis firmware.
Message Format | "This operation is not supported by the current version of the XL Chassis firmware." |
Severity | Warning |
Resolution | Please update the XL Chassis firmware to latest version. |
This operation is not supported when the system Boot Mode is set to Legacy BIOS.
Message Format | " This operation is not supported when the system Boot Mode is set to Legacy BIOS." |
Severity | Warning |
Resolution | Change the Boot Mode to UEFI and retry the operation. |
This operation is not supported by the current version of the system BIOS.
Message Format | "This operation is not supported by the current version of the system BIOS." |
Severity | Warning |
Resolution | None. |
The operation was not successful due to the current security state of the management processor.
Message Format | "The operation was not successful due to the current security state of the management processor." |
Severity | Warning |
Resolution | Retry the operation with the correct security state. |
The update failed because a bad parameter was supplied.
Message Format | "The update failed because a bad parameter was supplied." |
Severity | Critical |
Resolution | Supply correct parameters to the component and retry the update. |
The update was canceled by the update process.
Message Format | "The update was canceled by the update process." |
Severity | Critical |
Resolution | Retry the update. |
The update did not complete because the component failed a dependency check.
Message Format | "The update did not complete because the component failed a dependency check." |
Severity | Critical |
Resolution | Install any dependent components first and then retry this update. |
The update failed with a component specific error (%1).
Message Format | "The update failed with a component specific error (%1)." |
Severity | Critical |
Resolution | Retry the update after remedying the component error. |
System must not be booted past POST in order to perform this update
Message Format | "System must not be booted past POST in order to perform this update" |
Severity | Critical |
Resolution | Boot to UEFI and retry the update. |
The update was interrupted.
Message Format | "The update was interrupted." |
Severity | Critical |
Resolution | Retry the update. |
The update operation failed because the file is not valid.
Message Format | "The update operation failed because the file is not valid." |
Severity | Critical |
Resolution | Remove and re-add the component to the repository and try the operation again. |
The update did not occur because the running OS is not valid.
Message Format | "The update did not occur because the running OS is not valid." |
Severity | Critical |
Resolution | Retry the update while running the correct OS. |
The task was not completed because the component was not applicable to this system.
Message Format | "The task was not completed because the component was not applicable to this system." |
Severity | Critical |
Resolution | None. |
The update operation failed because the component repository is unavailable.
Message Format | "The update operation failed because the component repository is unavailable." |
Severity | Critical |
Resolution | None. |
The Invoke action was not successful because the update task queue is full.
Message Format | "The Invoke action was not successful because the update task queue is full." |
Severity | Critical |
Resolution | Remove completed tasks from the update task queue to retry the operation. |
The UpdateTaskQueue write failed.
Message Format | "The UpdateTaskQueue write of %1 failed." |
Severity | Warning |
Resolution | Ensure a valid name for the item and that space exists to hold the item. |
The system is temporarily unable to perform this update
Message Format | "The system is temporarily unable to perform this update" |
Severity | Critical |
Resolution | Retry the update, ensuring that power state is stable. |
System power must be off to perform this update
Message Format | "System power must be off to perform this update" |
Severity | Critical |
Resolution | Power system on and retry the update. |
System power must be on to perform this update
Message Format | "System power must be on to perform this update" |
Severity | Critical |
Resolution | Power system on and retry the update. |
The user or login user name already exists.
Message Format | "The user or login user name already exists." |
Severity | Warning |
Resolution | Try a different user or login user name. |
Duplicate SNMPv3 User.
Message Format | "The username %1 already exists in the list" |
Severity | Warning |
Resolution | Enter a different name and try again. |
Virtual Media has been disabled.
Message Format | "Virtual Media has been disabled." |
Severity | Warning |
Resolution | Enable Virtual Media to perform this operation. |
The sum of zone power limit cannot be more than chassis power limit.
Message Format | "The value %1 for the sum of %2 cannot be more than chassis power limit %3." |
Severity | Warning |
Resolution | Correct the value avoid the sum of power limit exceeds chassis power limit, and then retry the operation. |
Indicates that one or more properties were correctly changed, but will not take effect until device is reset and system is rebooted.
Message Format | "One or more properties were changed and will not take effect until the device is reset and system is rebooted" |
Severity | Warning |
Resolution | Reset the management processor and reboot the server. |
The subnet being configured has conflicts.
Message Format | "The subnet being configured for %1 conflicts with %2." |
Severity | Warning |
Resolution | Configure this interface with a different IP Address or Subnet Mask. |
The Virtual NIC is disabled.
Message Format | "The Virtual NIC is disabled." |
Severity | Warning |
Resolution | Enable iLO Virtual NIC to perform this operation. |
The task with id %1 has been aborted.
Message Format | "The task with id %1 has been aborted." |
Severity | Critical |
Resolution | None. |
The task with id %1 has been cancelled.
Message Format | "The task with id %1 has been cancelled." |
Severity | Warning |
Resolution | None. |
The task with id %1 has completed.
Message Format | "The task with id %1 has completed." |
Severity | OK |
Resolution | None. |
The task with id %1 has completed with warnings.
Message Format | "The task with id %1 has completed with warnings." |
Severity | Warning |
Resolution | None. |
The task with id %1 has been paused.
Message Format | "The task with id %1 has been paused." |
Severity | Warning |
Resolution | None. |
The task with id %1 has changed to progress %2 percent complete.
Message Format | "The task with id %1 has changed to progress %2 percent complete." |
Severity | OK |
Resolution | None. |
The task with id %1 has been removed.
Message Format | "The task with id %1 has been removed." |
Severity | Warning |
Resolution | None. |
The task with id %1 has been resumed.
Message Format | "The task with id %1 has been resumed." |
Severity | OK |
Resolution | None. |
The task with id %1 has started.
Message Format | "The task with id %1 has started." |
Severity | OK |
Resolution | None. |